1-8-005:2002
An American National Standard
--``,``-`-`,,`,,`,`,,`---
Steel (M-8, P-8, or S-8),
18 through 10 Gauge,
in the As-Welded
Condition, with or
without Backing
Site License
company use only. Copies may not be made available to any individual not employed by
Licensee or for any purpose unrelated to the business being conducted by Licensee.
3. Any reproduction must include the following copyright notice: “Copyright by the American
Welding Society. Reproduced with the express written permission of the American Welding
Society.”
4. Licensee may not enter into any sublicense agreement.
5. Reproduction of this Standard Welding Procedure signifies that you agree with the terms of the
License. If you do not agree with the terms of this License please return this document, and a
new document without the copyright notice will be issued.
6. The AWS B2 Standard Welding Procedures are not the subject of any warranty. AWS disclaims
any liability arising from the use of any Standard Welding Procedure. AWS is not liable for any
actual or consequential damages that may arise from the use of any Standard Welding
Procedure.
7. Licensee will notify AWS in writing if it becomes aware that any employee or other party has
made copies or otherwise made use of any Standard Welding Procedure contrary to the terms of
the License.
8. This License contains the entire understanding as between Licensee and AWS, and any changes
must be contained in a writing signed by both parties.
9. The terms of this License are governed under the laws of the State of Florida, and both parties
agree to submit to the jurisdiction of the cognizant court of law within Dade County, Florida to
resolve any disputes.
Prepared by
AWS B2 Committee on Welding Qualification
Approved by
AWS Board of Directors
Abstract
This standard contains the essential welding variables for welding austenitic stainless steel in the thickness range of 18
through 10 gauge, using semiautomatic gas metal arc welding (short circuiting transfer mode). It cites the base metals
and operating conditions necessary to make the weldment, the filler metal specifications, and the allowable joint designs
for fillet welds and groove welds.
--``,``-`-`,,`,,`,`,,`---
--``,``-`-`,,`,,`,`,,`---
Publication of this standard does not authorize infringement of any patent. AWS disclaims liability for the infringement
of any patent resulting from the use or reliance on this standard.
Finally, AWS does not monitor, police, or enforce compliance with this standard, nor does it have the power to do so.
On occasion, text, tables, or figures are printed incorrectly (errata). Such errata, when discovered, are shown on the
American Welding Society web page (www.aws.org) under “Technical” in the Departments column.
Official interpretations of any of the technical requirements of this standard may be obtained by sending a request, in writing,
to the Managing Director, Technical Services Division, American Welding Society, 550 N.W. LeJeune Road, Miami, FL
33126 (see Annex A). With regard to technical inquiries made concerning AWS standards, oral opinions on AWS standards
may be rendered. However, such opinions represent only the personal opinions of the particular individuals giving them.
These individuals do not speak on behalf of AWS, nor do these oral opinions constitute official or unofficial opinions or inter-
pretations of AWS. In addition, oral opinions are informal and should not be used as a substitute for an official interpretation.
This standard is subject to revision at any time by the AWS B2 Committee on Welding Qualification. It must be reviewed
every five years, and if not revised, it must be either reapproved or withdrawn. Comments (recommendations, additions,
or deletions) and any pertinent data that may be of use in improving this standard are required and should be addressed to
AWS Headquarters. Such comments will receive careful consideration by the AWS B2 Committee on Welding Qualifi-
cation and the author of the comments will be informed of the Committee’s response to the comments. Guests are invited
to attend all meetings of the AWS B2 Committee on Welding Qualification to express their comments verbally. Proce-
dures for appeal of an adverse decision concerning all such comments are provided in the Rules of Operation of the
Technical Activities Committee. A copy of these Rules can be obtained from the American Welding Society, 550 N.W.
LeJeune Road, Miami, FL 33126.
--``,``-`-`,,`,,`,`,,`---
J. J. Sekely, Chair Eichleay Corporation
G. M. Wisbrock, 1st Vice Chair Lockheed Martin Missiles and Fire Control
J. J. Fluckiger, 2nd Vice Chair Bechtel Babcock & Wilcox Idaho
P. B. Dickerson, 3rd Vice Chair Consultant
L. P. Connor, Secretary American Welding Society
T. J. Anderson Consultant
*W. L. Ballis Consultant
*H. B. Cary Consultant
J. L. Cooley J. C. and Associates, Incorporated
W. D. Doty Doty and Associates
E. A. Gallagher Non Destructive Testing Group
E. H. Gray, P.E. U.S. Nuclear Regulatory Commission
M. Herrle ABS Group, Incorporated
*J. E. Hinkel The Lincoln Electric Company
*M. J. Houle Welding Engineering Services
R. W. Jackson Consultant
A. W. Johnson A. W. Johnson and Associates
*N. K. Kanaya BEAR Testing Laboratory
R. A. LaFave, P.E. Elliott Company
*B. B. MacDonald United Association
K. M. McTague Factory Mutual
A. S. Olivares Hartford Steam Boiler Inspection and Insurance Company
*G. W. Oyler Retired
S. Panezic Canadian Welding Bureau
J. F. Pike NASA Langley Research Center
*B. J. Rampolla, P.E. J. J. McMullen and Associates
W. M. Ruof Bechtel Plant Machinery, Incorporated
*J. B. Shore Brooks Automation
A. W. Sindel Sindel and Associates
C. E. Speader, Jr. Aristech Chemical Corporation
*W. J. Sperko, P.E. Sperko Engineering Services
*R. F. Waite, P.E. Consultant
R. K. Wiswesser Welder Training and Testing Institute
iii
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
Foreword
(This Foreword is not a part of AWS B2.1-8-005:2002, Standard Welding Procedure Specification (SWPS) for
Gas Metal Arc Welding (Short Circuiting Transfer Mode) of Austenitic Stainless Steel (M-8, P-8, or S-8), 18 through
10 Gauge, in the As-Welded Condition, with or without Backing, but is included for informational purposes only.)
The American Welding Society and the Welding Research Council have joined in a cooperative effort to generate
standard welding procedures for industry. The need for pretested welding procedures that are supported by adequate test
data and that satisfy the technical requirements for the commonly used construction codes and specifications has been
expressed by many individuals and organizations. The purpose of a welding procedure qualification is to provide test
data for assessing the properties of a weld joint.
This Standard Welding Procedure Specification is an outgrowth of the coordinated work of the Welding Procedures
Committee of WRC and the Committee on Welding Qualification of the AWS. The Welding Procedures Committee has
provided the test data documented on the Summary of Procedure Qualification Records, which are available from the
Welding Research Council.
The welding terms used in this specification shall be interpreted in accordance with the definitions given in the latest
edition of AWS A3.0, Standard Welding Terms and Definitions. Welding symbols shall be those shown in the latest edition
of AWS A2.4, Standard Symbols for Welding, Brazing, and Nondestructive Examination.
The AWS B2 Committee on Welding Qualification was formed in 1979 to provide welding standards concerning the
subject of qualification. The primary document developed by this committee is AWS B2.1, Standard for Welding Procedure
and Performance Qualification. This document established the foundation and framework for Standard Welding Procedure
Specifications.
The first two Standard Welding Procedure Specifications were published in 1990. Since then SWPSs are continuing
to be developed and published by the American Welding Society. This is the first revision of B2.1.005.
Comments and suggestions for the improvement of this standard are welcomed. They should be sent to the Secretary,
AWS B2 Committee on Welding Qualification, American Welding Society, 550 N.W. LeJeune Road, Miami, FL 33126.
--``,``-`-`,,`,,`,`,,`---
iv
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 1 of 12
Floor, New York, NY 10016-5902. ity of any regulatory limitations prior to use.
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 2 of 12
LIMITATIONS
WELDING PROCESSES
BASE METALS
Base Metal:2 Austenitic Stainless Steel, M-8, P-8, or S-8 to M-8, P-8, or S-8
Thickness Range:3 Groove Weld: 18 gauge (0.0500 in.) through 10 gauge (0.1406 in.)
Fillet Weld: 18 gauge (0.0500 in.) through 10 gauge (0.1406 in.)
Coating: Uncoated
FILLER METALS
JOINT DESIGNS
POSITIONS
2. M, P, and S numbers for base metal and F and A numbers for filler metal and weld metal, respectively, are as detailed in
AWS B2.1 and ASME Boiler and Pressure Vessel Code, Section IX.
3. See the applicable ASTM Specification for base metal thickness tolerances.
--``,``-`-`,,`,,`,`,,`---
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 3 of 12
GAS
Torch Shielding Gas: Helium plus Argon and Carbon Dioxide or AWS A5.32, Class SG-
HeAC-7.5/2.5
Composition: 90% Helium, 7-1/2% Argon, 2-1/2% Carbon Dioxide
Flow Rate: 25 to 40 ft3/hr
Gas Nozzle Size: 1/2 in. diameter minimum (I.D.)
Backing/Root Shielding Gas: Welding Grade Argon or AWS A5.32, SG-A. Gas shall remain in
place until the joint is completed. When introducing shielding gas to
initiate a purge; it is necessary to have at least a 6 volume change
of atmosphere within the purge zone prior to welding. It is not nec-
essary to shield the root of fillet welds or groove welds with backing
or back gouging.
Flow Rate: A typical flow range of 5 to 15 ft3/h may be varied depending on
component configuration.
Trailing Gas: None
Penetration Enhancing Flux Not permitted
ELECTRICAL CHARACTERISTICS
*Any 300 series filler metal conforming to A No. 8 may be selected to meet the strength requirements; however, corrosion
requirements may dictate the specific selection.
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 4 of 12
TECHNIQUE
In the name of the Company stated above, I accept full responsibility for the application of this SWPS for use
with:
Permission to reproduce for intra-company use only is granted by the American Welding Society
--``,``-`-`,,`,,`,`,,`---
JOINT 1
JOINT 4
--``,``-`-`,,`,,`,`,,`---
JOINT 2
JOINT 5
JOINT 3 JOINT 6
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 6 of 12
JOINT 7 JOINT 11
JOINT 8
JOINT 12
JOINT 9
Metric Conversions
--``,``-`-`,,`,,`,`,,`---
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 7 of 12
Nonmandatory Annex
Annex A
Guidelines for Preparation of Technical Inquiries
for AWS Technical Committees
(This Annex is not a part of AWS B2.1-8-005:2002, Standard Welding Procedure Specification (SWPS) for
Gas Metal Arc Welding (Short Circuiting Transfer Mode) of Austenitic Stainless Steel (M-8, P-8, or S-8), 18 through
10 Gauge, in the As-Welded Condition, with or without Backing, but is included for informational purposes only.)
Permission to reproduce for intra-company use only is granted by the American Welding Society
--``,``-`-`,,`,,`,`,,`---
Following the subcommittee’s development of the re- an official interpretation of any AWS standard with the
sponse, the inquiry and the response are presented to the information that such an interpretation can be obtained
entire committee for review and approval. Upon approval only through a written request. The Headquarters staff
by the committee, the interpretation will be an official in- cannot provide consulting services. The staff can, how-
terpretation of the Society, and the secretary will transmit ever, refer a caller to any of those consultants whose
the response to the inquirer and to the Welding Journal names are on file at AWS Headquarters.
for publication.
Permission to reproduce for intra-company use only is granted by the American Welding Society
--``,``-`-`,,`,,`,`,,`---
--``,``-`-`,,`,,`,`,,`---
Stainless Steel (M-8, P-8, or S-8), 18 through 10 Gauge, in the As-Welded Condition, with or
without Backing
B2.1-1/8-010:2002 Standard Welding Procedure Specification (SWPS) for Gas Tungsten Arc Welding of Carbon
Steel to Austenitic Stainless Steel (M-1, P-1, or S-1 to M-8, P-8, or S-8), 18 through 10 Gauge,
in the As-Welded Condition, with or without Backing
B2.1-1-011:2002 Standard Welding Procedure Specification (SWPS) for Shielded Metal Arc Welding of Galva-
nized Steel (M-1), 10 through 18 Gauge, in the As-Welded Condition, with or without Backing
B2.1-1-012:2002 Standard Welding Procedure Specification (SWPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1, P-1, or S-1 to M-1, P-1, or S-1), 10 through 18 Gauge, in the As-Welded Condition,
with or without Backing
B2.1-8-013:2002 Standard Welding Procedure Specification (SWPS) for Shielded Metal Arc Welding of
Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 10 through 18 Gauge, in the As-Welded
Condition, with or without Backing
B2.1-1/8-014:2002 Standard Welding Procedure Specification (SWPS) for Shielded Metal Arc Welding of Carbon
Steel to Austenitic Stainless Steel (M-1 to M-8/P-8/S-8, Group 1), 10 through 18 Gauge, in
the As-Welded Condition, with or without Backing
B2.1-22-015:2002 Standard Welding Procedure Specification (SWPS) for Gas Tungsten Arc Welding of Aluminum
(M/P/S-22 to M/P/S-22), 18 through 10 Gauge, in the As-Welded Condition, with or without
Backing
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 10 of 12
Designation Title
B2.1-1-016-94 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E7018, As-Welded or PWHT
Condition
B2.1-1-017-94 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E6010, As-Welded or PWHT
Condition
B2.1-1-018-94 Standard Welding Procedure Specification (WPS) for Self-Shielded Flux Cored Arc Welding
of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E71T-8, As-Welded
Condition
B2.1-1-019-94 Standard Welding Procedure Specification (WPS) for CO2 Shielded Flux Cored Arc Welding
of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E70T-1 and
E71T-1, As-Welded Condition
B2.1-1-020-94 Standard Welding Procedure Specification (WPS) for 75% Ar/25% CO2 Shielded Flux Cored
Arc Welding of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick,
E70T-1 and E71T-1, As-Welded or PWHT Condition
B2.1-1-021-94 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding Followed
by Shielded Metal Arc Welding of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through
1-1/2 inch Thick, ER70S-2 and E7018, As-Welded or PWHT Condition
B2.1-1-022-94 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E6010 (Vertical Uphill)
Followed by E7018, As-Welded or PWHT Condition
B2.1-8-023-94 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of
Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 1/8 through 1-1/2 inch Thick, As-Welded
Condition
B2.1-8-024:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding of Austenitic
Stainless Steel (M-8/P-8/S-8, Group 1), 1/16 through 1-1/2 inch Thick, ER3XX, As-Welded
--``,``-`-`,,`,,`,`,,`---
Condition, Primarily Plate and Structural Applications
B2.1-8-025:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding followed
by Shielded Metal Arc Welding of Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 1/8
through 1-1/2 inch Thick, ER3XX and E3XX-XX, As-Welded Condition, Primarily Plate and
Structural Applications
B2.1-1-026-94 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2). 1/8 through 1-1/2 inch Thick, E6010 (Vertical Downhill)
Followed by E7018, As-Welded or PWHT Condition
B2.1-1-027:1998 Standard Welding Procedure Specification (WPS) for Self-Shielded Flux Cored Arc Welding
of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1/2 inch Thick, E71T-11, As-Welded
Condition
B2.1-1-201-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 3/4 inch Thick, E6010 (Vertical Uphill)
Followed by E7018 (Vertical Uphill), As-Welded Condition, Primarily Pipe Applications
B2.1-1-202-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 3/4 inch Thick, E6010 (Vertical Downhill)
Followed by E7018 (Vertical Uphill), As-Welded Condition, Primarily Pipe Applications
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale
AWS B2.1-8-005:2002
Page 11 of 12
Designation Title
B2.1-1-203-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 3/4 inch Thick, E6010 (Vertical Uphill), As-
Welded Condition, Primarily Pipe Applications
B2.1-1-204-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 3/4 inch Thick, E6010 (Vertical Downhill Root
with the Balance Vertical Uphill), As-Welded Condition, Primarily Pipe Applications
B2.1-1-205-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E6010 (Vertical Uphill)
Followed by E7018 (Vertical Uphill), As-Welded or PWHT Condition, Primarily Pipe
Applications
B2.1-1-206-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E6010 (Vertical Downhill) Fol-
lowed by E7018 (Vertical Uphill), As-Welded or PWHT Condition, Primarily Pipe Applications
B2.1-1-207-96 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, ER70S-2, As-Welded or
PWHT Condition, Primarily Pipe Applications
B2.1-1-208-96 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Carbon
Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, E7018, As-Welded or PWHT
Condition, Primarily Pipe Applications
B2.1-1-209-96 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding Followed
by Shielded Metal Arc Welding of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through
1-1/2 inch Thick, ER70S-2 and E7018, As-Welded or PWHT Condition, Primarily Pipe
Applications
B2.1-1-210:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding with Con-
sumable Insert Root of Carbon Steel (M-1/P-1/S-1, Group 1 or 2), 1/8 through 1-1/2 inch
Thick, INMs-1 and ER70S-2, As-Welded or PWHT Condition, Primarily Pipe Applications
B2.1-1-211:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding with
Consumable Insert Root followed by Shielded Metal Arc Welding of Carbon Steel (M-1/P-1/
S-1, Group 1 or 2), 1/8 through 1-1/2 inch Thick, INMs-1, ER70S-2, and E7018, As-Welded
Condition, Primarily Pipe Applications
B2.1-8-212:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding of Austenitic
Stainless Steel (M-8/P-8/S-8, Group 1), 1/16 through 1-1/2 inch Thick, ER3XX, As-Welded
Condition, Primarily Pipe Applications
B2.1-8-213-97 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of Austenitic
Stainless Steel (M-8/P-8/S-8, Group 1), 1/8 through 1-1/2 inch Thick, E3XX-XX, As-Welded
Condition, Primarily Pipe Applications
B2.1-8-214:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding followed by
Shielded Metal Arc Welding of Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 1/8 through
1-1/2 inch Thick, ER3XX and E3XX-XX, As-Welded Condition, Primarily Pipe Applications
B2.1-8-215:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding with
Consumable Insert Root of Austenitic Stainless Steel (M-8/P-8/S-8, Group 1), 1/8 through
1-1/2 inch Thick, IN3XX and ER3XX, As-Welded Condition, Primarily Pipe Applications
B2.1-8-216:2001 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding with
Consumable Insert Root followed by Shielded Metal Arc Welding of Austenitic Stainless Steel
(M-8/P-8/S-8, Group 1), 1/8 through 1-1/2 inch Thick, IN3XX, ER3XX, and E3XX-XX, As-
Welded Condition, Primarily Pipe Applications
Permission to reproduce for intra-company use only is granted by the American Welding Society
--``,``-`-`,,`,,`,`,,`---
Designation Title
--``,``-`-`,,`,,`,`,,`---
B2.1-4-217:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding of
Chromium-Molybdenum Steel (M-4/P-4, Group 1 or 2), ER80S-B2, 1/8 through 1/2 in.
Thick, As-Welded Condition, 1/8 through 3/4 in. Thick, PWHT Condition, Primarily Pipe
Applications
B2.1-4-218:1999 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of
Chromium-Molybdenum Steel (M-4/P-4, Group 1 or 2), E8018-B2, 1/8 through 1/2 in.
Thick, As-Welded Condition, 1/8 through 1-1/2 in. Thick, PWHT Condition, Primarily Pipe
Applications
B2.1-4-219:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding followed by
Shielded Metal Arc Welding of Chromium-Molybdenum Steel (M-4/P-4, Group 1 or 2), 1/8
through 1/2 in. Thick, As-Welded Condition, 1/8 through 1-1/2 in. Thick, PWHT Condition,
ER80S-B2 and E8018-B2, Primarily Pipe Applications
B2.1-4-220:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding (Consum-
able Insert Root) of Chromium-Molybdenum Steel (M-4/P-4, Group 1 or 2), E8018-B2, 1/8
through 1/2 in. Thick, As-Welded Condition, 1/8 through 3/4 in. Thick, PWHT Condition,
IN515 and ER80S-B2, Primarily Pipe Applications
B2.1-4-221:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding (Consum-
able Insert Root) followed by Shielded Metal Arc Welding of Chromium-Molybdenum Steel
(M-4/P-4, Group 1 or 2), 1/8 through 1/2 in. Thick, As-Welded Condition, 1/8 through 1-1/2 in.
Thick, PWHT Condition, IN515, ER80S-B2, and E8018-B2, Primarily Pipe Applications
B2.1-5A-222:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding of
Chromium-Molybdenum Steel (M-5A/P-5A), ER90S-B3, 1/8 through 1/2 in. Thick, As-Welded
Condition, 1/8 through 3/4 in. Thick, PWHT Condition, Primarily Pipe Applications
B2.1-5A-223:1999 Standard Welding Procedure Specification (WPS) for Shielded Metal Arc Welding of
Chromium-Molybdenum Steel (M-5A/P-5A), E9018-B3, 1/8 through 1/2 in. Thick, As-Welded
Condition, 1/8 through 1-1/2 in. Thick, PWHT Condition, Primarily Pipe Applications
B2.1-5A-224:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding followed by
Shielded Metal Arc Welding of Chromium-Molybdenum Steel (M-5A/P-5A), 1/8 through 1/2 in.
Thick, As-Welded Condition, 1/8 through 1-1/2 in. Thick, PWHT Condition, ER90S-B3 and
E9018-B3, Primarily Pipe Applications
B2.1-5A-225:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding (Consum-
able Insert Root) of Chromium-Molybdenum Steel (M-5A/P-5A), 1/8 through 1/2 in. Thick,
As-Welded Condition, 1/8 through 3/4 in. Thick, PWHT Condition, IN521 and ER90S-B3,
Primarily Pipe Applications
B2.1-5A-226:1999 Standard Welding Procedure Specification (WPS) for Gas Tungsten Arc Welding (Consum-
able Insert Root) followed by Shielded Metal Arc Welding of Chromium-Molybdenum Steel
(M-5A/P-5A), 1/8 through 1/2 in. Thick, As-Welded Condition, 1/8 through 1-1/2 in. Thick,
PWHT Condition, IN521, ER90S-B3, and E9018-B3, Primarily Pipe Applications
For ordering information, contact Global Engineering Documents, an Information Handling Services (IHS) Group company,
15 Inverness Way East, Englewood, Colorado 80112-5776; telephones: (800) 854-7179, (303) 397-7956; fax (303) 397-
2740; Internet: www. global.ihs.com.
Permission to reproduce for intra-company use only is granted by the American Welding Society
Copyright American Welding Society
Provided by IHS under license with AWS
No reproduction or networking permitted without license from IHS Not for Resale