0 Scope
The manual describes the automatically operating filter F 450 and the handling of
the equipment.
0-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
0 Scope 0-1
0.1 Structure and Use of the Operation Manual 0-1
0.2 Table of Contents 0-2
0.3 List of Illustrations 0-4
0.4 List of Tables 4
0.5 List of Abbreviations 0-5
0.6 Intended and Improper Use 0-6
0.7 Necessary Diligence of the Operator 0-7
0.8 Qualification and Education of the Staff 0-8
0.9 Liability 0-9
1 Safety 1-1
1.1 Symbols 1-1
1.2 Basic safety instructions 1-2
1.3 Accident Prevention Rules 1-5
1.3.1 General 1-5
1.3.2 Assembly/Disassembly 1-5
1.3.3 Transport/Location 1-5
1.3.4 Electrical System 1-6
1.3.5 Compressed Air Unit 1-6
1.3.6 Safety at Setting out of Operation 1-7
1.3.7 Maintenance and Repair 1-7
1.4 Operation 1-8
2 Description 2-1
2.1 General 2-1
2.2 Technical Description 2-1
2.2.1 Description of the Operational Functions 2-2
2.2.2 Controlling of the Automatically Operating Filter F 450 2-4
5 Operation 5-1
5.1 Controls 5-1
5.2 Program Operation 5-2
5.3 Sequence of Control Activities 5-4
0-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
6 Maintenance 6-1
6.1 Cleaning 6-1
6.2 Flushing Disc 6-1
6.3 Pneumatic Cylinder 6-1
6.4 Seals 6-2
8 Appendix 8-1
8.1 Terminal Assignment at Control Panel 8-1
8.2 Printed Circuit Board Assignment 8-3
8.3 Communication 8-4
9 Optional 9-1
9.1 Terminal Assignment Clamping Box 9-1
0-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
0-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
AC Alternating Current
DC Direct Current
DPS Differential pressure switch
etc. et cetera
GND Ground
LS 1 Proximity Switch 1
LS 2 Proximity Switch 2
T1 Interval Time
T2 Pre-Flushing Time
T3 Stroke Time
SV 1 Solenoid Valve 1
SV 2 Solenoid Valve 2
0-5
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The Automatically Operating Filter F450 exclusively serves for the filtration of the
operating medium indicated in the Certificate of Acceptance. The admissible op-
erational data registered on the name plate are to be kept. The filter satisfies the
requirements of the EC Pressure Equipment Directive 97/23/EC and the Directive
94/9/EC.
• Reading this operation manual as well as keeping all references contained in,
appertain to the intended use. That applies in particular to the notes of cau-
tion.
• Furthermore the requirement to strictly follow the operating instructions, the
inspections and maintenance regulations.
• Any malfunctions possibly impairing the safety must be cleared immediately!
• The filter is designed for continuous operating parameters. After longer oper-
ating conditions the filter insert must be cleaned before a renewed start-up, if
necessary.
Any other use or any use going beyond the rules (e.g. at higher operating tem-
peratures or operating pressures) will be regarded as an improper use. The
manufacturer will not be liable for any damage resulting there from. The user of
the Automatically Operating Filter F450 is responsible for all property and per-
sonal damage which develop from not intended use.
The Automatically Operating Filter F450 is designed according to the state of the
art and the recognized safety-relevant rules. Nevertheless, its use might cause
danger to the user’s or third person’s lives and limbs or impair the filter or other
intrinsic values.
In order to avoid damage or lethal injuries with the use of the Automatically Op-
erating Filter F 450, the following points are to be considered:
• The filter should only be used in a technically faultless condition and accord-
ing to intended purpose.
• Inform yourself about the correct operating before switching on of the device.
• Read the chapter "safety".
0-6
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Please keep these operation manual carefully field and handy at the locations
where the filter will be used.
Please follow generally effective legal and other binding regulations with regard
to the prevention of accidents and the protection of the environment as a sup-
plement to these operation manual. Such binding regulations may e.g. equally
concern the use of hazardous materials or the availability/wearing of personal
protective equipment.
Prior to starting their work, the personnel in charge of the operation of the ma-
chine should have read the operating instructions and in particular the chapter
„Safety Rules“ in detail. This will particularly apply to any personnel working only
occasionally at the filter, e.g. while setting it up or maintaining it. At least some
time or other, the staff should be controlled if they were in fact working in a safety
relevant manner, being fully aware of possible dangers and following the operat-
ing instructions.
Please follow all the instructions at the filter with regard to safety and dangers.
In case of any safety-relevant modifications regarding the filter or operational per-
formance, the filter should immediately be shut down and this malfunctions re-
ported to the competent department.
Any spare parts should comply with the technical requirements stipulated by the
manufacturer, which will always be guaranteed for genuine spare parts.
At any rate, the time intervals for recurrent tests/inspections laid down or indi-
cated in the operating instructions should be kept.
An adequately equipped workshop outfit for the maintenance work will be abso-
lutely indispensable.
0-7
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Only reliable personnel should be allowed to perform any work at the filter. The
legal minimum age should be taken into account.
Any personnel to be trained at, semi-skilled at, or familiarized with this work or
working within the scope of a general training should only be permitted to be ac-
tive with regard to the filter under permanent supervision of an experienced per-
son.
Any work in connection with the electrical equipment of the filter must either be
carried out by a skilled electrician or by instructed persons according to the elec-
trotechnical rules under the guidance and supervision of a skilled electrician only.
0-8
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
0.9 Liability
Guarantee and liability claims with damages to property and person are ex-
cluded, if they are to due several of the following causes:
The complete guarantee only and exclusive is taken over for spare parts from
Georg Schünemann GmbH for the Automatically Operating Filter F450!
0-9
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
1 Safety
Important Instructions!
All persons, who are involved with start-up, operation and maintenance of the fil-
ter, must be accordingly qualified and trained.
Existing rules for accident prevention and laws must be kept in each case.
1.1 Symbols
Use for hazardous situations with high probability of death or severe injury. Do
not use for property damage unless personal injury risk present.
Use for hazardous situations which have some probability of death or severe
injury. Do not use for property damage unless personal injury risk is present.
Use for hazardous situations, which may result in minor or moderate injury. Do
not use when there is a possibility of death or severe injury.
Use for indicating a statement of company policy as the message relates directly
or indirectly to the safety of personnel or protection of property. Do not use for
hazardous situations where death or severe injury may occur.
1-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Hazardous Pressure
Before maintenance and repair work you should make sure at any rate that the
vessel is unpressurized prior to starting any maintenance work at the Automati-
cally Operating Filter F450.
Hazardous Voltage
Prior to any maintenance and repair work, the filter should be deenergized and
safeguarded against unintentional reenergizing. The zero potential is to be de-
termined. Neighbouring energized parts are to be covered or provided with
gates.
Explanation:
If incorrect or not expressly described parts at • Only parts may be inserted, attached or
the filter are installed and/or changed, the func- changed, which are listed in the manual and
tion of the filter can be set out of strength or the pertinent documents.
disturbed substantially.
Possibility to injuries of the serving and mainte- In case of doubt, information is to be obtained
nance staff during the operation and mainte- • by the manufacturer.
nance.
Use only prescribed and perfect tools for the
• repair.
Explanation:
If the diameter of the inlet and/or expiration line • Guarantee that the drain lines have the di-
does not correspond to the defaults of the ameter demanded by the manufacturer.
manufacturer of the filter, the function of the
filter can be set out of strength or disturbed
substantially.
1-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Explanation:
If the diameter of the inlet and/or expiration line • Examine the filter regularly according to
does not correspond to the defaults of the manu- chapter 6 „Maintenance“.
facturer of the filter, the function of the filter can
be set out of strength or disturbed substantially.
Explanation:
Each filter is built for a certain pressure range, a • Install the filter exclusively into systems for
certain temperature range and a certain me- those the filter is designed and certified.
dium. If the filter is built into another system, as
being planned than, the function of the filter can
be set out of strength or disturbed substantially.
Burn hazard!
Burn of fingers and/or hands
Explanation:
If the filter in a system is operated, as the me- • Isolate all parts of the system, at those a burn
dium reaches a temperature of more than 122 °F danger exists or attach warnings
(50 °C), burn danger exists alone by contact of
the filter surface.
Burn hazard!
Explanation:
If the filter is subjected unintentionally during • Before starting maintenance and repair work
maintenance with pressure, depending upon make sure at any rate that the vessel is un-
kind of the medium injuries such as burn, scald, pressurized during any maintenance work.
caustic or radioactive contamination are possi-
ble.
1-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Crush hazard
Crush injuries of the fingers, hands and/or feet
Explanation:
The filter has a minimum weight of 37.5 lbs • During transport, assembly and maintenance
(17 kg), depending upon model. During trans- work wear safety clothing.
port, the assembly, disassembly and mainte-
nance work crush injuries of the fingers, hands • Secure the filter during transport, assembly,
and/or the feet are possible. disassembly and maintenance work against
slipping and falling down.
Hazardous voltage
Explanation:
Hazardous voltages of more than 48 V are pre- • Prior to any maintenance and repair work, the
sent in the control unit. Danger exists by con- filter should be deenergized and safeguarded
tact of voltage carrying parts. against unintentional reenergizing.
1-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
1.3.1 General
After assembly and before initial operation of the filter a safety check must be
carried out (new installation or assembly after transport). All machine parts are to
be examined for their perfect condition.
Check the filter for operational safety before setting into operation (see chapter
4.4, page 4-5)!
Pay attention to the instructions in this manual and the generally valid, local
safety regulations and rules for accident prevention!
Attached warning and signs give important notes for safety operation. Pay atten-
tion to the warnings.
The staff carries the responsibility for their own security and the security of third
in the work area. These responsibility cannot be delegated!
1.3.2 Assembly/Disassembly
During assembly/disassembly only the staff, necessary for it, may stay in the
work area of the filter.
Pay attention to sufficient free space of motion and stability of the ground.
Check that after the assembly all components were duly added (control for tight-
ness).
Check that all cables and connecting cables are attached to the points planned
for it!
Before initial operation of the filter the operating personnel have to convince itself
of the faultless state by prescribed controls.
1.3.3 Transport/Location
Before the transport of the filter the components are to be packed in an appropri-
ate and careful way.
1-5
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Any work in connection with the electrical equipment of the filter must be carried
out by a skilled electrician!
Circuit diagrams are to be used as a basis for this jobs.
Before opening the control unit, power supply for the filter is to be switched off or
disconnected!
Danger of Hazardous Voltage.
Mark the main switch by a warning “Do not Operate Electricians at Work“ and
safeguard the filter against unintentional reenergizing!
Check the electrical equipment of the filter regularly. Repair slack connections as
well as damaged cables immediately!
Keep the control unit permanently closed. Thus the protection from humidity and
contamination is guaranteed.
Check regularly the air supply lines and the connections of the air supply unit for
correct attachment and leakages.
Replace damaged or strongly worn components of the compressed air unit im-
mediately.
All work on the compressed air unit of the filter is to be carried out in the operat-
ing stop only. The electrical system is to be set out of operation.
Die compressed air unit is to be set out of operation and into pressure-free condi-
tion. The compressed air unit is safeguarded against unintentional repressuring
and marked by a sign “work on compressed air unit“.
1-6
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Take care that the Automatically Operating Filter F 450 is safeguarded against
unauthorized reenergizing after setting out of operation.
Mark the power switch in the control unit by a warning “Out of order“ and secure
the power switch against unauthorized restarting with a suitable locking device.
Also the compressed air unit is safeguarded against unauthorized setting into
operation and marked by a warning ”Out of order“
Accomplish the prescribed maintenance work, as they are described in the chap-
ter 6 "Maintenance"!
Prior to any maintenance and repair work, the filter should be deenergized and
safeguarded against unintentional reenergizing!
It is to be paid attention absolutely, that the filter is unpressurized prior to start-
ing any maintenance!
1-7
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
1.4 Operation
If malfunctions are determined during the operation of the filter, then the filter
should be shut down immediately.
Proceed as described in
Chapter 1.3.4 “Electrical System“,
Chapter 1.3.5 “Compressed Air Unit“,
Chapter 1.3.6 “Safety at Setting out of Operation“,
Chapter 6 “Maintenance“,
Chapter 7 “Trouble shooting“
The determined malfunction may be repaired only with switched off Automati-
cally Operating Filter F 450!
The Automatically Operating Filter F 450 may be set into operation again only af-
ter cut out the malfunction.
1-8
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
2 Description
2.1 General
(See Fig. 8-6, page 8-7 and Fig. 8-7, page 8-8)
The contaminated medium flows by the flange marked as entrance into the filter.
It moves through the filter insert from the inside to outward and steps cleaned out
from the flange marked as exit. The flushing phase of the filter is activated either
by reaching at the differential pressure switch the differential pressure or after a
pre-set interval of time. The flushing valve opens and a greater amounts of soil-
ing flushes out. Afterwards the flushing disc makes two strokes in the filter insert,
thus producing an increase in speed between the flushing disc and the filter wall.
The local loss of pressure produced a ”suction effect” in the filter element. By
means of this pressure drop the coarser and easily cleanable particles are
flushed out of the insert liner through the opened flushing valve out of the filter.
2-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The operation of the Automatically Operating Filter F 450 is divided into the nor-
mal operation and the flushing phases:
Normal operation
2-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
2-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The automatic filter will be controlled via an electronic control box. The parame-
ters will be entered via the keyboard or via the integrated serial interface respec-
tively. Thus the filter can be monitored and remote controlled by a control station.
The programmable control unit supervises at defined measuring points the pres-
sure within the entry region of the filter. It triggers the flushing process caused by
monitored differential pressure or time-based control algorithm. The flushing pro-
cedure can be released additionally at any time manually.
2-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
3 General Data
The Automatically Operating Filter F 450 is equipped with signs and a name
plate! Always consider the hints, instructions and operating values appropriate
on the signs and name plate!
3-1
Stand: 03/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Dimensions: W 9.45 “ (240 mm) x H 8.27 “ (210 mm) x D 3.74 “ (95 mm)
Defective fuses must be replaced only by such, which corresponds to the origi-
nal fuses in value and design!
Repairing or bridging fuses as well as using repaired fuse cartridges are not
permitted.
3-2
Stand: 03/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Please read before installation and setting to work accurately the operation man-
ual.
• The medium supply pipe and drain pipe must be layed in streamline.
• The cross sections of the supply pipe and drain pipe corresponds to those of
the filter inlet and outlet at least.
• And the supply and drain pipe must be layed without any mechanically stress
to the filter. This applies also under thermal load conditions of the pipes.
• The different operating parameters such as filter nominal size, flow rate,
pressure and/or the pertinent pump characteristic must be considered in the
configuration and correctly implemented.
• Particularly the drilling diameter of the aperture and the diameter of the flush-
ing disc affect the cleaning.
• These components must be adapted on change of the operating parameters
(e.g. diameter/flow rate) by SAB.
4-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
4.2 Unpack
Before beginning
See
Crush hazard!
The filter has a mass of at least 37.5 Ibs (17 kg). During transport and the as-
sembly, crush injuries of the fingers, hands and/or the feet could happen.
Control:
4-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
4.3 Installation
4-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
.
5. If the cover is delivered separate of the filter, connect the air lines for the
pneumatic cylinder in accordance with the attached connection diagram
(see Fig. 8-8, page 8-9). Connect the compressed air feed to the com-
pressed air station with an air hose of at least 10/1 mm. The air pressure
has to be about 87 psi (6 bars) and a maximum of 116 psi (8 bars) /
Special 50.7 psi (3.5 bars).
6. If the pneumatic controlling is not mounted at the filter, connect the water
hose for the differential pressure switch to the connections A and B in ac-
cordance with the connection diagram. In this process, it is important to
know that the filter’s automatic mechanism does not function if the con-
nections are changed.
8. If the filter has mounted a termonal box, the connection to voltage supply
as well as the external components such as flushing valve etc. is made by
screw-type terminals in the separately accessible terminal box. The fuses
are also placed here.
4-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
1. Before setting into operation check the proper condition of the electric ca-
bles and connections of the control.
2. Check the compressed air adapter. The distribution of compressed air must
be supplied with 87 psi (6 bars) / Special 50.7 – 116 psi (3.5 – 8 bars),
check with pressure gauge. Check before setting into operation whether the
distribution of compressed air, the magnetic valve and the pneumatic cylin-
der (drive of the flushing disc) are properly supplied with compressed air.
• In order to avoid damage to the filter and the plant, never operate the filter
without the control. The operation without liquid is not damaging the filter.
At emptying from pipes therefore it is not necessary to set the filter out of
operation for its own protection.
4-5
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Start up the electronic control by switching on the mains switch (Fig. 8-7 / 12,
page 8-8) at the control unit. After switching on the control unit a filtration cycle is
introduced automatically (The filtration can be started also at any time by press-
ing the key "FLUSH").
Check whether the flushing valve opens and the piston carries out thereafter two
strokes (pre and decreasing/going back movement). The test of the piston func-
tion should be accomplished under operating conditions, because a high system
pressure and flow impair the time which is used for a full piston stroke.
It is to be considered, that the pressure difference of 145 psi (10 bars) does not
arise. Otherwise the membrane of the differential pressure switch can be dam-
aged.
4-6
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Implement the following steps, in order to check the proper function of the filter.
4.6.1 Switch on Control with the Power Switch, first Flushing Phase/Pre-Flushing
Check.
By pressing the power switch the first flushing phase starts automatically. The dirt
drain valve opens against "atmosphere-pressure" and/or around at least 8.7 psi
(0.6 bars) for lower system pressure (consider pressure losses of the piping).
During the first flushing phase the flushing disc is located in the initial position in
the upper region of the filter housing.
1. Adjust the pre-flushing time T2 at the electronic control according to the fil-
ter size if necessary (see Tab. 4-1, page 4-9).
2. Adjust opening velocity of the dirt drain valve by means of throttles. Turn
throttles in clockwise direction slows down the opening.
Attention! Opening to fast causes impacts in the pipes!
The running time must be adjusted absolutely at initial start-up locally, under re-
alistic operating conditions. This cannot be done in the factory!
In the second flushing phase the pneumatic drive starts to move down and the
flushing disc drives through the filter. At the reed contacts are light emitting di-
odes, which indicate a reaching of the end point.
1. Adjust the time for piston stroke of the pneumatic drive by means of com-
pressed air throttles present on the drive to the running time in accordance
with table 4-1, page 4-9.
Too fast accomplishing of the strokes of the pneumatic cylinder affects the filtra-
tion negatively, because the sieve is moved through from the flushing disc to
fast.
4-7
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The control time specifies only the max. time (seconds) between start and end
of a piston stroke. If this time is exceeded a warning is given! The piston stroke
itself is set at the compressed air throttles (see item 1).
The valve of the flushing line closes some seconds after the flushing disc is
moved back into the initial position. The LCD display at the control indicates
“F 450“.
Change the adjustment only if it should be optimized. Wait for operational ex-
perience!
In the case of cleaning of the sieve with a high pressure cleaner is to be paid
attention to an appropriate distance!
Otherwise the sieve can be damaged by a too high pressure!
4-8
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
4-9
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
5 Operation
5.1 Controls
The control will be switched on and off via the power switch (at the right side of
the housing). Afterwards the control can be activated by pressing the < ON/OFF
> - key (Fig. 8-7 / 15). The operation is done menu guided on the liquid crystal
display (LCD) (Fig. 8-7 / 20) and with the keys at the front panel. Alternatively
operation is also possible via the interface. The following keys and displays are
installed at the control unit.
5-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
After switching on, the control system starts a flushing procedure immediately. By
pressing the < ON/OF > key the control system can be deactivated. A renewed
pressing of this key will activate the control system.
Switch on parameter mode: For setting the parameter, the control system must
be set into "OFF"-condition. In order to switch on the parameter mode, both arrow
keys must be pressed simultaneously, and the <ON/OFF> key must be actuated
too. The arrow keys must be kept in the pressed-down position for 2 s, and the
program will start in the parameter mode.
ALTERNATIVELY and/or at new control systems the < Enter > key is pressed for
approx. 2 seconds, and the program will start in the parameter mode.
During this mode of operation, the flushing function is switched off. It will neither
be possible to interchange the data via the serial interface.
Data input: Using the arrow keys, the individual menu items could then be se-
lected and activated by means of the <ENTER> key. The entries should be made
by means of the arrow keys and terminated by means of the <ENTER> key. In
case of multi-place entries, this has to be done for each place. Upon termination
of the menu by using the <ENTER> key, the parameters altered in such a man-
ner will be stared and safeguarded against a voltage breakdown.
Operating hours Here the hour meter of the control system is indicated. A
maximum period of 999.999 hours can be added up.
This value cannot be modified.
Lifting time T3 (control This period can be set within a range of 1sec up to
time for piston stroke) 23h59min59sec. It represents the running time that the
pneumatic piston may need for reaching a terminal posi-
tion (LS1, LS2).
5-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Contrast At this menu item the contrast of the LCD can be modi-
fied in order to ensure a better readability depending on
the viewing angle.
DPS – Log The flushing times as well as the time intervals between
these various flushing procedures will be recorded and
stored as a minute value. This is how a maximum num-
ber of 76 values (38 flushing cycles and cycles without
flushing) can be stored and called up again. If the mem-
ory is full, the older values will automatically be overwrit-
ten. The memory position indicated at first will get the
oldest value.
5-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
There are three types of flushing when the control mechanism is switched on and
ready for operation:
• manual flushing:
The flushing process is started by pressing the <FLUSH> button. The
pneumatic piston runs through two strokes after the set flushing time ex-
pires.
• If the pneumatic piston does not reach its end position (LS1, LS2) within the
prescribed time T3, there is an error signal “stroke error” and the stroke is
triggered. The further sequence is identical to constant flushing.
5-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
6 Maintenance
It is absolutely necessary to ensure that the filter is not under pressure before
starting maintenance, because the Automatically Operating Filter F 450 is a
pressure vessel.
The individual components described in the following are also illustrated in Fig.
8-6, page 8-7 in the appendix.
6.1 Cleaning
• Remove the compressed air hoses and resp. disconnect the piping at the
therefore intended fittings and removal the proximity switch (LS1 and LS2)
from the pneumatic cylinder.
• Loosen the cover screws and carefully raise the cover including the pneu-
matic cylinder and flushing disc with a lifting device.
• The filter insert can be taken out and cleaned by loosening of the sieve
nuts/mothers.
• After removing the cover the flushing disc, mounted at the lower end of the
piston rod of the pneumatic cylinder, may be inspected of damages and
could be replaced if necessary.
• After removing the flushing disc the pneumatic cylinder may be completely
removed by loosening the four flange screws on the cover and inspected
for damage.
6-1
Stand: 03/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
6.4 Seals
• The cover seal is accessible when the filter is open and may be inspected
of damages and replaced if necessary.
• The seals for the piston rod lead-through are accessible when the pneu-
matic cylinder has been removed and may be inspected damages and re-
placed if necessary.
6-2
Stand: 03/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
7 Trouble shooting
This chapter describes possible potential malfunctions, their causes and how to
repair.
Prior to any maintenance and repair work, the filter should be deenergized and
safeguarded against unintentional reenergizing!
The zero potential is to be determined. Neighboring energized parts are to be
covered or provided with gates.
Stroke failure Throttle valves at cylin- Open throttle valves (Fig. 8-6 / 3a,
der closed 3b, page 8-7) until the running time
is in accordance with the manual
(see Tab. 4-1, page 4-9)
Stroke failure Stroke time isn't correctly Open throttle valves (Fig. 8-6 / 3a,
set in the control system 3b, page 8-7) until the running time
(running time too long) is in accordance with the manual
(see Tab. 4-1, page 4-9)
7-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Stroke failure The aperture is damaged Check aperture (Fig. 8-6 / 5, page 8-
too much and/or the ef- 7) for design and operating-
fective operating para- parameters. The aperture diameter
meters are not the same is computed by SAB on the basis of
as those which have throughput in m³/h and the pump
been designed by de- characteristic.
mensioning
Proximity switch defec- Check proximity switches for func-
tive/wrongly wires tion. Light emitting diodes (Fig. 8-6 /
3c, 3d, page 8-7) must indicate the
beginning and final position of the
piston when reaching. Check wiring
in accordance with clamp allocation
(page 8-1).
Continuous Shut-off valve does not Check throttle valves and open if
flushing open necessary.
Check compressed air hoses for
correct connection in accordance
with diagram of "air and water con-
nections" (Fig. 8-8, on page 8-9).
7-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Back flushing line mislaid The back flushing line should be laid
pressure-free. Each pressure loss is
to be considered during the design
of the aperture (Fig. 8-6 / 5, page 8-
7), because the backpressure has
effects on the back flushing quantity.
Possibly the aperture diameter must
be increased.
Bad cleaning ac- Running time of the cyl- Check run time length in accor-
tion inder-piston not set cor- dance with chapter 4.6 and set cor-
rectly (running time too rectly if necessary (see Tab. 4-1,
short) page 4-9)
7-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Back flushing line mislaid The back flushing line should be laid
pressure-free. Each pressure loss is
to be considered during the design
of the aperture
(Fig. 8-6 / 5, page 8-7), because the
diameter has effects on the back
flushing quantity and therefore on
the backflushing character.
Possibly the aperture diameter must
be increased.
Bad cleaning ac- Failure of control Possibly the current supply failed,
tion system* whereby the cleaning did not take
place in the regular interval.
Remove filter insert and clean it with
high pressure cleaner.
*In case of wrong polarity the light emitting diodes of the proximity switches of the
pneumatic cylinder do not respond.
7-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
8 Appendix
Terminal Assignment
8-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
8-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Fig. 8-4 Printed Circuit Board Assignment till Serial Number 2568
Fig. 8-5 Printed Circuit Board Assignment from Serial Number 2569
8-3
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
8.3 Communication
After transmitting the instructions, any control system data can only be received
upon a changeover time of approx. 20 ms.
The data record structure for the autonomous signal for error conditions differs
from the structure of the control and the inquiry during normal operation. The fol-
lowing error conditions will be signaled via the interface:
8-4
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The data records for manipulation and data inquiry of the control system are
structured as follows:
Instruction Set:
8-5
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
The user has to be guaranteed that the filter is not subjected with pressure,
as long as the filter is off and/or the contact "operating condition" is opened,
in order to avoid a damaging of the filter insert.
8-6
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F 450
8-7
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F 450
8-8
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F 450
8-9
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
9 Optional
Terminal Assignment
X1/ PE free
X1 / 1 Input LS1, brown, potential free contact required (+5 V DC) *
X1 / 2 Input LS1, blue, (0 V)
X1 / 3 Input LS2, brown, potential free contact required (+5 V DC) *
X1 / 4 Input LS2, blue, ” (0 V)
X1 / PE free
X1 / 5 Output solenoid valve piston SV2, (+ at 24 V DC)
X1 / 6 Output solenoid valve piston SV2, (- at 24 V DC)
X1 / PE free
X1 / 7 Output flushing valve SV1, (+ at 24 V DC)
X1 / 8 Output flushing valve SV1, (- at 24 V DC)
X1 / PE free
X1 / 9 Input DPS potential free contact required
X1 / 10 Input DPS potential free contact required
X1 / 11 free
X1 / PE free
X1 / 12 reserve
X1 / 13 reserve
X1 / 14 reserve
X1 / 15 reserve
X1 / 16 reserve
X1 / 17 reserve
X1 / 18 reserve
X1 / 19 reserve
X1 / 20 reserve
X1 / PE free
* At wrong polarity, the LEDs of the proximity switches will not act
9-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
9-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
Declaration of conformity
TÜV 05 ATEX 2804 X
Equipment category II 2 G c T4
• The filter is approved for a explosive risked region with gases, vapours,
fog,which need equipments of the category 2.
• Outside of the filter Zone 1 is approved. Inside with none zone. The operator
has to pay attention that the inside remains without zone.
• The filter is not signed with the ambient temperature of the region. This has
to be taken out of the declaration of conformity.
The manpower planning and the operation of the filter in explosive risked region
have to be effected by the generally rules of technic. The employment has to be
resolved by attention of the equipment nameplate, the operation manual and the
declaration of conformity.
The filter has to be grounded before setting-up operation and should not be iso-
lated electrical.
The employments are only permitted to be done by an electrical qualified person
with accordant qualification. The electrical connection takes place in the EX-
certificated terminal box outside of the explosive risked region, if it is included in
delivery. The operation is only permitted with completely closed and undamaged
boxes. The operation with a damaged box is forbidden.
ATTENTION : Before functioning at the electric circuit and before opening the
terminal box inside of the explosive risked region, the electric circuits have to be
switched into the dead-voltage / currentless status.
Only therefor permitted tools and measuring equipments are allowed to be em-
ployed in the explosive risked region. In case of a disturbance the circuit connec-
tions and the electricity supply outside of the explosive risked operation region
have to be checked on there correct function.
Modifications and repairings at the electric components are not allowed.
If only the proximity switch and the differential pressure switch are delivered, they
have to be connected at intrinsically safe electric circuit, for example:
10-1
Stand: 09/2007 Georg Schünemann GmbH, Bremen
Automatically Operating Filter F450
If the filter is delivered without any electrical equipments, all provided electrical
components, supplied by the customer, have to be up to the mark of the guide-
line 94/9/EG (ATEX 100a).
The pneumatic cylinder and all continuing electrical attachments of the filter have
to perform the guideline 94/9/EG accordant its appliance. By installation and op-
eration of this devices their operation manuals and the EN 60079-14 have to be
respected.
The device is only permitted for the operation with compressed air, which is pro-
duced and prepared outside of the EX-region. Requirements should be taken
from the provided operation manual for the pneumatic valves of the Company
Festo.
If the filter will be set in operation outside of atmospheric conditions but in explo-
sive atmosphere, the approval only provides a basis as guideline.
Additional inspections for the special provided operating conditions are sug-
gested. This inspections are laying in the area of authority at the operator.
10.4 Maintenance
The electrical attached parts have to be maintained and cleaned regular accord-
ing to the delivered documents. The intervals are forced by the operator.
The exchange of components only has to take place with original spare parts,
which are approved for the employment in the EX-region.
10-2
Stand: 09/2007 Georg Schünemann GmbH, Bremen