Professional Documents
Culture Documents
ACO Catalog
ACO Catalog
900 Mio.
The ACO Group is a world market leader in drainage
technology. Climate change sets us a challenge to react
effectively with innovative solutions to new environmental
conditions. With its integrated approach, ACO stands for
professional drainage, efficient cleaning, and the control- Euro Sales in 2019
led discharge or reuse of water. Products include drainage
channels and drains, oil and grease separators, backflow
stop systems, pumps and pressure-water-tight cellar win-
35
dows and light shafts.
ACO Academy
ACO Building Drainage for practical training
5
We are your expert in all technical and planning matters
for drainage solutions in buildings. With experience and
passion, we will find the most rational and economical
solution for you which meets all professional and standard
requirements.
6 7
They are primarily used in commercial kitchens where hygi-
ene is of great importance. Optionally, it can be manufac-
tured from the corrosion-resistant materials stainless steel
1.4301 or 1.4571.
The professional planning of kitchen drainage 1. Definition and positioning of the 3. Project planning for the piping
sanitary drainage objects systems which are to be connected
From a planning point of view, catering establishments are to be desig-
ned in such a way that the entire collection of kitchen waste water, its
Efficient work processes must be economical as well as For needs-based drainage of kitchen waste water collec-
discharge and the associated treatment in grease separators is exactly hygienic and reliable in commercial kitchens. Therefore, ted via drain and channel systems, the pipe systems to be
tailored to the respective kitchen. the drainage objects required for the work processes must connected must be selected according to the following
be planned with the following criteria in mind: criteria:
As market leader for all product solutions associated with this process,
ACO Building Drainage can provide advice on all issues during planning, nn Capacity/discharge capacity nn As far as the diameters are concerned, the pipes must be
When selecting the drain or channel type, the properties connected to the drain systems without any problems.
design and installation. All the important milestones for appropriate plan- of the drainage objects which are to be connected must nn Due to the intended applications, care must be taken to
ning are explained below. be taken into account. For this purpose, the connection ensure that the pipe systems have a high temperature
values of the kitchen objects (e.g. taps or the volumes of resistance.
the heating tanks) are to be used. nn When passing through ceilings, the respective fire pro-
tection regulations must be observed.
nn Sealing ring
The floor structure must be protected from damage by
the kitchen waste water. It must be determined where and
how the floor structure is to be secured (e.g. by alternative 4. Evaluation and selection of suita-
or foil sealing).
ble systems for the retention of fatty
nn Slip resistance components in kitchen waste water
If drainage channels are located directly in employee work
areas, covers/grates must be selected in such a way that For needs-based drainage of kitchen wastewater collected
sufficient slip resistance is ensured. via drain and channel systems, the pipe systems to be
connected must be selected according to the following
criteria:
2. Planning and selection of drainage nn The size determination (NS) of the grease separator must
Food industry
Food preparation
Due to the production processes used in various food This could be the case, for example, in edible oil refineries,
Whilst cleaning pans, dishes and other kitchen equipment This primarily applies to hotels, university refectories, can- industries, waste water containing animal and vegetable peanut roasters and factories producing crisps and chips.
units in commercial kitchens, a great deal of waste water teens, service stations and hospitals, as well as cafeterias in fats that can be retained may arise during food manufac-
containing grease or fat is produced, which cannot be fed shopping centres and large kitchens which grill, roast and ture.
into the sewage system just like that. fry.
10 11
Factories producing meat Materials and shapes for every building situation
When slaughtering and dismembering animals, as well as depending on the particular production processes used ACO grease separators are made from polyethylene or (e.g. round, oval or split), grease separators can be easily
processing them into meat and sausage products, large in the factory and the grease has to be removed from this stainless steel. Polyethylene is characterised, for instance, retrofitted into buildings during renovation work, for
amounts of waste water still with a very high grease con- waste water accordingly. Besides meat and sausage facto- by its lightweight construction and long lifetime, whilst example. Unusual conditions can be dealt with by means
tent are created. This could add up to several tons per day, ries, this primarily applies to slaughterhouses and butchers. stainless steel also offers high temperature resistance. of special constructions and site welds.
By choosing the shape that best fits the building project
3
Technical information
Grease separator plants
13
Technical information Technical information
Grease separators for full disposal Grease separators for partial disposal (fresh grease separators)
A grease separator for full disposal operates
purely physically on the basis of gravity Grease separators working on the partial disposal princi- rator into the collecting drums is done by opening the
(density differences), i.e. heavy waste water ple also operate purely physically on the basis of gravity relevant drainage valve on the separator (specifics depend
constituents sink to the floor of the separa- (density differences), i.e. heavy waste water con-stituents on the type of operation).
tor, light substances such as animal fats and sink to the floor of the separator, whilst light substances This can be undertaken independently of normal opera-
oils, rise to the top of the grease separator. such as animal oils and fats rise to the top of the separator. tions. For example, it can be done without interrupting the
The treated waste water is discharged into The separated substances (grease and sludge) are collec- work being carried out in a kitchen.
the sewers via a drainage outlet pipe. ted in separate containers. The treated waste water is then Because the collecting drums only take up grease and
The sludge trap and the separator must discharged into the sewers via the drainage outlet pipe. sludge, the grease separator does not have to be filled
be completely emptied and cleaned at Draining the separated substances from the grease sepa- after disposal with expensive fresh water.
least once a month pursuant to EN 1825.
Emptying the sludge trap and the separator
is carried out by a disposal company and
it is recommended that this operation be
carried out every two weeks. The separator
then has to be refilled with water (e.g. drin-
king water or process water) in compliance
with the local water regulations.
Lipator-S-RM: Lipator-S-RA:
Grease separator for partial dis- Grease separator for partial
posal, for manual grease/sludge disposal, for automated grease/
extraction sludge extraction
Technical information Technical information
Product benefits: ACO extension stage system Pipework, ventilation (EN 1825-2)
A grease separator must be emptied at regular intervals by out the disposal and cleaning of the grease separator. n When installing the inlet line through unheated or freely
a disposal vehicle. The extension stage system means that The available extension stages and the respective ease accessible spaces where there is a danger of frost, this
odour nuisance can be reduced during disposal and clea- of disposal and cleaning they provide can be seen in the section of the route must be designed with auxiliary
ning. The higher the extension stage, the easier to carry table below. pipe heating (e.g. self-regulating strip heaters and insu-
lation).
Extension
stage LipuSmart-P LipuJet-P LipuJet-S
for free-standing installation
Basic
version
-OM -RM
2
with —
disposal
18 pump 19
n The inlet and outlet lines on grease separator systems
-OMP -RMP must be adequately ventilated. To this end, route the
vent stack to above the roof (EN 1825-2).
n Other horizontal connecting lines longer than 5 m must
be ventilated in addition. If the horizontal inlet line is
longer than 10 m and there are no other additionally
3
ventilated connecting lines, the inlet line must be fitted
with an extra vent stack right by the separator inlet
(EN 1825-2).
-OA -OA -RA
3
with
disposal
pump
Pipework with ACO PIPE High-pressure inner cleaning of ACO grease separators
Materials that are resistant to corrosion and fatty acids must
be used for the inlet and ventilation lines of grease separa-
tor plants in particular. Stainless steel, material grade 316 is
recommended here.
With ACO PIPE, ACO Building Drainage provides a pipe
system that is ideally suited for this purpose.
Separate pendulum gas pipe above the roof Pendulum gas line connected to ventilation Pendulum gas line connected to grease
line of grease separator separator
Technical information Technical information
Upstream tank plants with eccentric screw pumps ACO LipuTherm heat exchanger
The wastewater produced, e.g. in commercial kitchens and kind of buffer storage. At this first wastewater "collection
in the catering industry, is often still very hot when it is fed point" the temperature fluctuations are not so high and a
into the separator system. The temperature of wastewater continuous recovery process can be started. The savings
is increasingly becoming the focus for the inspection aut- can be considerable, depending on the size of the kitchen
horities. The basis for this are the local regulations, which and the temperature of the waste water.
can penalise the discharge of commercial waste water into Through the combination of the ACO LipuTherm heat
the public sewerage system at temperatures above 35°C exchanger with a power-controlled heat pump, the energy
with additional heavy pollution surcharges. recovered from the wastewater is made available to the
However, wastewater can be used as an innovative heat operator for a wide variety of possible applications.
source and contribute to the economic recovery of energy.
This is made possible by the LipuTherm system techno-
logy, which not only reduces the temperature in the nn Underfloor heating
separator, but also results in considerable cost savings for nn Solar systems
the operator. Grease separators not only retain grease or nn Support for hot-water treatment
oils from the generated wastewater, but also serve as a nn Connection to heat recovery systems already installed
24 25
The sensor head of the measuring equipment for grease It is particularly well suited to grease separator plants and
layer thickness uses electrodes arranged in various ways to their stringent drainage requirements and is available as a
detect the difference in the conductivity of water, grease constituent part or as a component for retrofitting. Grease
Application: grease separator below backflow level with downstream lifting plant and air. This enables the boundary layers between the separators with a traditional design are equipped with
water phase and the grease layer that is floating up, and inspection windows so the grease layer thickness can be
Waste water lifting plants convey waste water above the between the grease layer and the surrounding air to be measured visually, whereas on modern devices, this mea-
backflow level into the higher sewage system. EN 12056 determined. Maximum fill levels are then indicated on the surement is taken automatically by measuring equipment
stipulates that waste water lifting plants must be used fill level monitoring lamp display. for grease layer thickness.
where drainage points are below the backflow level, The operator has a high degree of flexibility in terms of The GSM module enables the operating parameters to be
i.e. for almost all free-standing grease separator plants. device maintenance thanks to a GSM module that makes retrieved via mobile phone and takes care of data transfer
Depending on the application scope, ACO offers a choice the process of checking and servicing grease separators, and the notification of disposal cycles and malfunctions –
of different waste water lifting plants that can be installed waste water lifting plants, backflow stops and process engi- all fully automatically.
directly behind the grease separators. neering plants much easier, more adaptable and faster.
ACO LipuFloc dosing station ACO odour neutraliser
The ACO odour neutraliser significantly reduces the formation of noxious smells in all vent stacks and plant components.
Chemical-physical wastewater treatment
The ACO LipuFloc ECO dosing system mainly consists of The control system is the central component, this is The composition of the waste water means that unplea- ventilation line, which overrides the unpleasant smells in
three components: the stainless steel control cabinet for where all information on filling levels and operating states sant smells are created in the grease separator both when the plant components.
the dosing equipment, the splitting agent drum and the converge. The central control unit can be conveniently the kitchen is operational and during idle periods. If vent Irrespective of any problems with line components, this
circulation unit. The dosing pump, a colour touch screen operated via touch panel. stacks have been installed incorrectly, this can lead to a makes really good sense primarily for low extension stages
and a status display with possible connection to the BMS The second component is powered and controlled from perceptible odour nuisance at critical line components which require a lot of cleaning, as it can significantly
are located directly on the control cabinet. The dosing the system section. This is a waste water pump that returns and drainage points. But help is at hand in the form of the reduce the spread of odours through the premises during
pump that is used conveys the chemical in the direction the pre-treated kitchen waste water from the grease sepa- ACO odour neutraliser: a flexible interval timer controls the monthly disposal of the separator contents.
of the grease separator in a time and quantity-dependent rator outlet to the grease separator inlet after the addition dosing of an odour neutralising agent, preferably into the
manner. To achieve this, it is conveyed directly from the of the chemicals.
exchangeable plastic drum by means of a suction lance
with fill level control. The level and quantity of the contai-
ner is recorded continuously.
26 27
Technical information Technical information
4 3 5 6
28 29
ACO LipuSmart: Integration of all components in one product Grease separator ACO LipuSmart:
and lifting system one ventilation
require separate duct for both
ventilation lines integrated appli-
cations
Grease separator
Sampling and collection
container for lifting plant
with pump technology
Product overview
5 ACO grease separators
Full disposal
Free-standing installation Page XX
The entire waste water contents of grease separators for
full disposal must be disposed of at regular intervals in
accordance with legal standards. Then the containers must
be cleaned, depending on requirements. The higher the
extension stage of the grease separator, the easier it is to
dispose of the waste water contents, clean the container
and re-fill the separator, and the less odour will be produ-
ced.
32 33
NS 15 to NS 30
welded containers
made of PE
-OAP
-P
-OB -OD -RB -RD -SB
-S-RM -S-RA
NS 4 to NS 25 -S
min 500
DN 100
ØD
nn Optional Bluetooth or Modbus LipuSmart-P-OB
connection NS Basic version
nn Structural stability of the container
H4
Article no.
with 25-year stability verification
H1
2
H2
3552.36.00
nn Compact erection dimensions
nn Only one vent stack necessary 3 3553.36.00
L1
L3 L2 4 3554.36.00
5.5 3555.36.00
7 3557.36.00
8.5 3558.36.00
B1
10 3560.36.00
Product informationen
min 500
ventilationDN100
DN 100 inspection door
Wartungsöffnung
Entlüftung
Anschluss
heating rod connection
Heizstab
sleeve (option)
(Option)
ØD
Table of dimensions LipuSmart-P-OD
NS Extension stage 1
H4
NS DN Separator content Lifting plan Dimensions Article no.
H1
H2
Sludge Grease Usable P2- 2 3552.66.00
store store Total volume Power H1 H2 H3 H4 L1 L2 L3 L4 L5 B1 B2 B3 D L1
3 3553.66.00
L3 L2
[l] [l] [l] [kw] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 4 3554.66.00
2 100 210 100 440 155 1.5 1055 753 1680 1500 1100 800 1625 300 680 742 880 930 110 5.5
disposal connection R 2mit
1/2, DIN 14308
36
Entsorgungsanschluss Storz-B-Kupplung R2 1/2, DIN14308
3555.66.00 37
3 100 300 150 630 155 1.5 1055 753 1680 1500 1450 800 1975 300 680 742 880 930 110 7 3557.66.00
4 100 400 200 830 155 1.5 1055 753 1680 1500 1760 800 2285 300 680 742 880 930 110 8.5 3558.66.00
B1
5.5 150 725 360 1430 235 4.0 1250 753 1880 1700 1760 835 2287 300 680 960 1130 1180 160 10 3560.66.00
7 150 800 400 1600 235 4.0 1250 753 1880 1700 1960 835 2487 300 680 960 1130 1180 160
8.5 150 940 475 1900 235 4.0 1250 753 1880 1700 2250 835 2777 300 680 960 1130 1180 160
10 150 1000 520 2000 235 4.0 1250 753 1880 1700 2450 835 2977 300 680 960 1130 1180 160
www.aco-haustechnik.de/catalogue/Article no.
All digital contents (data sheets (PDF)), dimensional drawings (DXF, IGS) and article descriptions (Datanorm, GAEB, TXT) relating to the grease
separators and additional components represented here can be retrieved from the website stated above using the respective article number.
Product overview Product overview
No annoying
LipuSmart 0A filling unit with ball and pressure-reducing valve
odours Convenience
inspection door high pressure cleaning head Fülleinheit mitKugelhahn u. Druckminderer
Kugelhahn u. Druckminderer
LipuSmart-P-OB
min 500
Entlüftung DN100
(Basic version)
heating rod connection sleeve
(option)
LipuSmart-P-OA nn Disposal and cleaning by opening the covers
—
Anschluss Heizstab (Option)
NS
ØD
control unit
Extension stage 3
high pressure
Steuerung (associated with the formation of noxious smells)
H3
pump
HD-Pumpe
Operating side left Operating side right
H4
Article no.
H1
H2
2 3552.76.32 3552.76.42
3 3553.76.32 3553.76.42 LipuSmart-P-OD
nn Manual, odour-free disposal via direct suction
(Extension stage 1)
L1
B2
nn Bluetooth interface
ventilation DN 100
inspection glass with a wiper
min 500
Entlüftung DN100
heating rodSchauglas
connectionmit Wischer
(Option)
sleeve (option)
LipuSmart-P-OAP
control unit
LipuSmart-P-OAP (Extension stage 3 with disposal pump)
Anschluss Heizstab
high pressure pump
NS
ØD
Steuerung
disposal pump
Article no.
H1
Absperrschieber
H2
Entsorgungs-
pumpe 2 3552.86.32 3552.86.42
L1
L2
3 3553.86.32 3553.86.42
disposal connection R 2 1/2, DIN 14308 L3
L5
4 3554.86.32 3554.86.42
Entsorgungsanschluss mit Storz-B-Kupplung R2 1/2, DIN14308
10 3560.86.32 3560.86.42
min 500
min 500
inspection door ventilation
ventilation depicted:
depicted:
stability verification DN 100
inspection glass NS4, operation side „right“,
DN 100 NS 4, operation side „right“,
for operation side „left“ the comp
inspection glass
nn Disposal and maintenance cost mini-
with a wiper for operation side „left“ the components (filling connection, filling unit, inspectio
(option) * with a wiper
unit, inspection glass) are placed placed mirrow-inverted with refe
ØD
inlet middle axis of the separator.
misation thanks to staggered nominal
ØD
mirrow-inverted with reference to the middle axis
inlet DN ... outlet
DN ... outlet of the separator. DN ... * not included in scope of delive
sizes (e.g. NS 5.5 and 8.5) DN ...
* not included in scope of delivery
H5
H4
high pressure pump
functional filling unit for high pressure
H3
H3
H4
internal cleaning and container filling
H1
H2
H1
H2
heating rod
connection
heating rod
sleeve
connection
(option) *
sleeve
(option) *
L4 L1
L3
L1
disposal connection
L2 R 2 1/2, DIN 14308 L2
Product informationen
B1
B2
B1
B2
nn Grease separator plant according to EN 1825
nn With integrated sludge trap
nn For free-standing installation in frost-proof premises
nn Inlets and outlets for connections to plastic pipes
Table of dimensions
high pressure
filling unit with ball and pressure-reducing valve filling unit with ball and pressure-reducing valve
inspection door cleaning head
(option) * inspection door
min 500
min 500
NS DN Separator content Dimensions Extension dimensions ventilation
disposal connection
R 2 1/2, DIN 14308 ventilation depicted:
depicted: DN 100
DN 100 NS 4, operation side „righ
NS 4, operation side „right“,
for operation side „left“ the
Grease inspection glass
with a wiper
for operation side „left“ the components inspection
glass with a components (disposal con
ØD
(option) * (filling unit, inspection glass) are placed wiper unit, inspection glass, stop
Sludge storage mirrow-inverted with reference inletto the middle
ØD
inlet DN ... outlet unit) are placed mirrow-in
axis of the separator.
DN ... outlet DN ... reference to the middle ax
trap volume Total H1 H2 H3 H4 L1 L2 B1 B2 D H5 L3 B3 L4 B4 DN ... * not included in scope of delivery
separator.
H5
control unit
40 41
H3
H3
H4
1 100 106 100 320 830 760 1480 1300 1100 1300 700 770 110 1500 1400 800 1800 930 high pressure pump stop valve
H5
H4
H1
H2
2 100 210 100 440 1055 985 1680 1500 1100 1300 700 770 110 1700 1400 800 1800 930
H1
H2
disposal pump heating rod
3 100 300 150 630 1055 985 1680 1500 1450 1650 700 770 110 1700 1750 800 2150 930 heating rod
connection
connection
sleeve
(option) *
sleeve
4 100 400 200 830 1055 985 1680 1500 1760 2000 700 770 110 1700 2060 800 2460 930 (option) *
L1
5.5 150 725 360 1430 1250 1180 1880 1700 1760 2000 950 950 160 1900 2060 1050 2460 1180 L1
L4
7 150 800 400 1600 1250 1180 1880 1700 1960 2200 950 950 160 1900 2260 1050 2660 1180 L2
disposal connection
R 2 1/2, DIN 14308 L2
8.5 150 940 475 1900 1250 1180 1880 1700 2250 2485 950 950 160 1900 2550 1050 2950 1180
10 150 1000 520 2000 1250 1180 1880 1700 2450 2690 950 950 160 1900 2750 1050 3150 1180
B1
B4
B2
B1
B2
www.aco-haustechnik.de/catalogue/Article no.
All digital contents (data sheets (PDF)), dimensional drawings (DXF, IGS) and article descriptions (Datanorm, GAEB, TXT) relating to the grease
separators and additional components represented here can be retrieved from the website stated above using the respective article number.
Product overview Product overview
high pressure
cleaning head
filling unit with ball and
pressure-reducing valve
LipuJet-P-OB LipuJet-P-OB No annoying
inspection door NS Basic model Basic model odours Convenience
min 500
ventilation depicted:
DN 100 NS 4, operation side „right“,
for operation side „left“ the components
Article no. LipuJet-P-OB
inspection glass
with a wiper 1
(disposal connection, filling unit, inspection
glass, control unit) are placed mirrow-in-
3551.34.00 3551.64.00 (basic model)
ØD
inlet
DN ... outlet 2
verted with reference to the middle axis of
the separator. 3552.34.00 3552.64.00
DN ...
nn Disposal and cleaning by opening the covers
3
* not included in scope of delivery 3553.34.00 3553.64.00 — —
(associated with the formation of noxious smells)
4 3554.34.00 3554.64.00
H5
H3
control unit
H4
high pressure
pump 5.5 3555.34.00 3555.64.00
H1
7 3557.34.00 3557.64.00
H2
heating rod
connection 8.5 3558.34.00 3558.64.00
sleeve* LipuJet-P-OD
10 3560.34.00 3560.64.00
(extension stage 1) nn Odour-free disposal via a connector to direct suction
L4 L1
L3
nn After-cleaning by opening the covers (associated with the
disposal connection
R 2 1/2, DIN 14308 L2
— slight formation of noxious smells)
nn Disposal connectionDN 65, counter flange with fire hose quick
coupling 75B and 2½" blank cap
B1
B2
B3
ventilation depicted:
DN100 5.5
NS4, operation 3575.74.41
side „right“, 3575.74.31 3575.84.41 3575.84.31 with free flow impeller (required for a total delivery head of
inspection glass for operation side „left“ the components manual
with a wiper
7 3577.74.41
(disposal connection, filling unit, inspection
3577.74.31 3577.84.41 3577.84.31 over 6 metres)
ØD
stop
H4
42
high pressure pump valve
LipuJet-P-OA 43
nn Programmed, odour-free disposal/cleaning via direct suction
H1
(extension stage 3)
H2
B2
min 500
pressure-reducing valve
min 500
inspection
nn NS 2 – 20 transport-friendly and easy inspection door ventilation depicted: door
depicted:
DN 100 NS 7, operation side „right“,
NS 7,operation side „right“,
installation because can be dismant- for operation side „left“ the components
for operation side „left“ the components
inlet inlet (disposal connection, control unit,
(inspection glass) are placed mirrow-inverted
led into separate components DN ... outlet with reference to the middle axis ofDN
the... ventilation outlet inspection glass, high pressure pump) are
DN ... DN 100 DN ... placed mirrow-inverted with reference to
inspection separator.
nn Optimal and easy cleaning thanks to glass with inspection
the middle axis of the separator.
a wiper * * not included in scope of delivery
round shape
ØD
glass with
ØD
* not included in scope of delivery
a wiper
nn Project-specific special solutions reali-
H5
H3
heating rod
H5
H3
heating rod
H4
connection
sable with parallel modular extensions connection
H1
sleeve *
H1
sleeve *
H2
H2
Project-specific special solutions reali-
sable with parallel modular extensions
Z
Z
ØD1 L3
ØD1 L3
L1
L1
Product informationen
L2
nn For free-standing installation in frost-proof premises L
L2
5
high pressure pump
nn Inlets and outlets for connections to plastic pipes
Table of dimensions LipuJet-P-RD (Extension stage 1) LipuJet-P-RMP (Extension stage 2 with disposal pump)
disposal connection
NS DN Separator content Dimensions Extension dimensions R 2 1/2, DIN 14308
high pressure
filling unit with ball and filling unit with ball disposal connection
cleaning head
min 500
pressure-reducing valve* and pressure-reducing R 2 1/2, DIN 14308
min 500
inspection
Grease door ventilation depicted:
inspection valve depicted:
DN 100 door
NS 7, operation side „right“, NS 7, operation side „right“,
Sludge storage for operation side „left“ the components for operation side „left“ the compone
inlet (disposal connection, inspection glass)
inletare (disposal connection, control unit, ins
trap volume Total H1 H2 H3 H4 L1 L2 L3 Z/n* D H5 L4 L5 D1 DN... outlet placed mirrow-inverted with referenceDN to...
the ventilation outlet glass, high pressure pump) are place
inspection DN... middle axis of the separator. mirrow-inverted with reference to the
DN 100 DN ...
[l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] glass with axis of the separator.
44 inspection 45
ØD
a wiper * * not included in scope of delivery
2 100 290 120 680 975 905 1320 1370 1255 60 150 795/2 110 1520 260 260 1020 control unit
ØD
glass with * not included in scope of delivery
a wiper
H5
heating rod
H3
4 100 500 160 890 1240 1170 1580 1630 1255 60 150 820/2 110 1780 260 260 1020
H5
H3
connection heating rod
H4
H1
sleeve * connection
H4
H1
H2
7 150 830 400 2120 1430 1330 1880 1930 1820 60 150 785/3 160 2080 260 260 1660 sleeve*
H2
stop valve
10 150 1150 400 2450 1600 1500 2050 2100 1820 60 150 785/3 160 2250 260 260 1660
Z
disposal pump
Z
15 200 1950 800 3610 1765 1665 2200 2250 2130 60 150 880/3 200 2400 260 260 1915
ØD1 L3
20 200 2440 800 4070 1955 1855 2400 2400 2130 60 150 880/3 200 2600 260 260 1915 ØD1 L3 L4
*n = number of segments L1
L1
4
L
L2
L2
L
5
www.aco-haustechnik.de/catalogue/Article no. high pressure pump
All digital contents (data sheets (PDF)), dimensional drawings (DXF, IGS) and article descriptions (Datanorm, GAEB, TXT) relating to the grease
separators and additional components represented here can be retrieved from the website stated above using the respective article number.
Product overview Product overview
inspection
door
depicted: LipuJet-P-RB
NS 7, operation side „right“, NS Basic model Extension stage 1
or operation side „left“ the components (basic model)
inlet
outlet
(disposal connection, control unit, inspection
glass, high pressure pump) are placed
Article no.
DN ... ventilation
DN 100 DN ... mirrow-inverted with reference to the middle
2 3502.32.30 3502.62.30
inspection
axis of the separator. nn Disposal and cleaning by opening the covers
4 3504.32.30 3504.62.30 — —
ØD
glass with
control unit
a wiper
* not included in scope of delivery (associated with the formation of noxious smells)
H5 7 3507.32.30 3507.62.30
H3
heating rod
connection
10 3510.32.30 3510.62.30
H4
H1
sleeve *
H2
15 3515.32.30 3515.62.30
20 3520.32.30 3520.62.30
Z
LipuJet-P-RD
ØD1 L3 (extension stage 1)
nn Odour-free disposal via a connector to direct suction
nn After-cleaning by opening the covers (associated with the
L1
— slight formation of noxious smells)
nn Disposal connection DN 65, counter flange with fire hose quick
coupling 75B and 2½" blank cap
LipuJet-P-RM
LipuJet-P-RMP nn Odour-free disposal via direct suction and automated inner
(extension stage 2)
4
L
L
NS Extension stage 2 with disposal pump nn Disposal connection DN 65, counter flange with fire hose quick
5
high pressure pump
Operating Operating Operating Operating manual coupling 75B and 2½" blank cap
side left side right side left side right
nn Filling device with ball valve for re-filling with fresh water
Article no.
nn Hydro-mechanic inner cleaning via high-pressure pump and
2 3502.73.41 3502.73.31 3502.73.81 3502.73.71 spray head
LipuJet-P-RAP (Extension stage 3 with disposal pump) 4 3504.73.41 3504.73.31 3504.73.81 3504.73.71
7 3507.73.41 3507.73.31 3507.73.81 3507.73.71 LipuJet-P-RMP
10 3510.73.41 3510.73.31 3510.73.81 3510.73.71 (extension stage 2 with disposal pump)
high pressure filling unit with ball and
disposal connection
15 3515.73.41 3515.73.31 3515.73.81 3515.73.71 nn Identical to LipuJet-P-RM, but with additional disposal pump
cleaning head pressure-reducing
min 500
valve
R 2 1/2, DIN 14308
depicted:
20 3520.73.41 3520.73.31 3520.73.81 3520.73.71 with free flow impeller (required for a total delivery head of
inspection door NS 7, operation side „right“, manual
for operation side „left“ the components over 6 metres)
inlet (disposal connection, control unit,
DN ... ventilation outlet inspection glass, high pressure pump) are nn Automated disposal and inner cleaning
DN 100 DN ... placed mirrow-inverted with reference to
the middle axis of the separator.
46 inspection
47
ØD
heating rod
connection LipuJet-P-RA
H4
H1
L
15 3515.73.42 3515.73.32 3515.73.82 3515.73.72
5
high pressure pump
20 3520.73.42 3520.73.32 3520.73.82 3520.73.72
ACO LipuJet-S – oval grease separators made of stainless steel Dimensional drawings
for free-standing installation
LipuJet-S-OB (Basic model) LipuJet-S-OM (Extension stage 2)
Product advanteges
filling unit with ball and
pressure-reducing valve *
high pressure filling unit with ball and
nn Rugged construction with 25-year disposal connection
cleaning head pressure-reducing valve
min 500
min 500
depicted: R 2 1/2,DIN 14308
ØD
a wiper *
ØD
glass with
H5
H5
functional filling unit for high pressure a wiper
H4
H3
internal cleaning and container filling
H3
heating rod
H1
heating rod
connection sleeve *
H1
connection sleeve*
H2
H2
high
pressure
pump
L4 L1
L3 L1
L3
L2
L2
Product informationen
B2
B1
B1
nn Grease separator plant according to EN 1825
B2
nn For free-standing installation in frost-proof premises
nn With integrated sludge trap
nn Inlets and outlets for connections to plastic pipes
min 500
R2 1/2, DIN 14308 cleaning head pressure-reducing valve
min 500
depicted: R 2 1/2, DIN 14308
Grease ventilation
NS 4, operation side „right“,
for operation side „left“ the components
depicted:
NS 4 opera
Sludge storage inspection door DN100 (disposal connection, inspection glass) are
placed mirrow-inverted with reference to the inspection door
ventilation
DN 100
for operatio
(disposal co
middle axis of the separator. glass) are p
trap volume Total H1 H2 H3 H4 L1 L2 B1 B2 D H5 L3 B3 L4 B4 inlet
DN...
inlet to the midd
outlet * not included in scope of delivery
DN ... outlet
[l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] DN... DN... * not includ
48 inspection
1 100 100 100 320 830 760 1200 1380 905 1100 635 760 110 1550 1320 370 1850 800 glass with inspection
ØD
ØD
H5
a wiper * glass
H5
control unit
with a wiper
2 100 200 100 440 1055 985 1320 1500 905 1100 635 760 110 1700 1320 370 1850 800
H4
H3
H4
stop valve
H3
3
H1
100 300 150 630 1055 985 1320 1500 1255 1450 635 760 110 1700 1670 370 2200 800 heating rod heating rod
H1
connection sleeve* connection
H2
H2
sleeve *
4 100 400 200 830 1055 985 1320 1500 1605 1800 635 760 110 1700 2020 370 2550 800 disposal pump
high
pressure
5.5 150 550 360 1430 1255 1185 1570 1750 1655 1920 885 1010 160 1950 2070 550 2600 1000 pump
7 150 700 400 1600 1255 1185 1570 1750 1855 2120 885 1010 160 1950 2270 550 2800 1000 L1
8.5 150 850 475 1900 1255 1185 1570 1750 2155 2420 885 1010 160 1950 2570 550 3100 1000 L3 L1 L4
10 150 1000 520 2000 1255 1185 1570 1750 2345 2610 885 1010 160 1950 2760 550 3300 1000 L2
L2
B1
B2
B1
B2
B4
www.aco-haustechnik.de/catalogue/Article no.
All digital contents (data sheets (PDF)), dimensional drawings (DXF, IGS) and article descriptions (Datanorm, GAEB, TXT) relating to the grease
separators and additional components represented here can be retrieved from the website stated above using the respective article number.
Product overview Product overview
No annoying
LipuJet-S-OB LipuJet-S-OD odours Convenience
high pressure filling unit with ball and NS Basic model Extension stage 1
disposal connection cleaning head pressure-reducing valve LipuJet-S-OB
min 500
R 2 1/2, DIN 14308
Article no.
depicted:
NS 4, operation side „right“,
(basic model)
ventilation 1
for operation side „left“ the components 7551.34.00 7551.64.00
DN 100 (disposal connection, control unit, inspection
inspection door
2
glass) are placed mirrow-inverted with reference 7552.34.00 7552.64.00 nn Disposal and cleaning by opening the covers
inlet to the middle axis of the separator. — —
DN... outlet 3 7553.34.00 7553.64.00 (associated with the formation of noxious smells)
DN ... * not included in scope of delivery
inspection
4 7554.34.00 7554.64.00
glass with a 5.5 7555.34.00 7555.64.00
Ø110
H5
control unit wiper
7 7557.34.00 7557.64.00
H4
H3
heating rod
8.5 7558.34.00 7558.64.00 LipuJet-S-OD
H1
connection sleeve *
H2
L2
LipuJet-S-OM
LipuJet-S-OMP nn Odour-free disposal via direct suction and automated inner
(extension stage 2)
LipuJet-S-OM Extension stage 2 cleaning due to high pressure spray head
NS Extension stage 2 with disposal pump nn Disposal connection DN 65, counter flange with fire hose
B1
B2
B4
Operating Operating Operating Operating manual quick coupling 75B and 2½" blank cap
B3
side left side right side left side right nn Filling device with ball valve for re-filling with fresh water
Article no. nn Hydro-mechanic inner cleaning via high-pressure pump
1 7571.74.41 7571.74.31 7571.84.41 7571.84.31 and spray head
2 7572.74.41 7572.74.31 7572.84.41 7572.84.31
3 7573.74.41 7573.74.31 7573.84.41 7573.84.31 LipuJet-S-OMP
LipuJet-S-OAP (Extension stage 3 with disposal pump)
4 7574.74.41 7574.74.31 7574.84.41 7574.84.31 (extension stage 2 with disposal pump)
5.5 7575.74.41 7575.74.31 7575.84.41 7575.84.31 nn Identical to LipuJet-S-OM, but with additional disposal
7 7577.74.41 7577.74.31 7577.84.41 7577.84.31 pump with free flow impeller (required for a total delivery
8.5 7578.74.41 7578.74.31 7578.84.41 7578.84.31 manual
disposal connection
high pressure
cleaning head
filling unit with ball and
pressure-reducing valve head of over 6 metres)
min 500
inspection glass
H5
H3
stop valve
heating rod connection
quick coupling 75B and 2½" blank cap
H1
sleeve *
automatic
H2
disposal pump high nn Filling device with solenoid valve for re-filling with fresh
pressure
pump water
LipuJet-S-OAP
LipuJet-S-OA nn Hydro-mechanic inner cleaning via high-pressure pump
Extension stage 3
L1
NS Extension stage 3 with disposal pump and spray head
L4
Operating Operating Operating Operating
LipuJet-S-OAP
side left side right side left side right
(extension stage 3 with disposal pump)
L2
Article no.
1 7571.74.42 7571.74.32 7571.84.42 7571.84.32 nn Identical to LipuJet-S-OA, but with additional disposal
2 7572.74.42 7572.74.32 7572.84.42 7572.84.32 automatic pump with free flow impeller (required for a total delivery
3 7573.74.42 7573.74.32 7573.84.42 7573.84.32 head of over 6 metres)
B1
B2
B4
ACO LipuJet-S – round grease separators made of stainless steel Dimensional drawings
for free-standing installation
LipuJet-S-RB (Basic model) LipuJet-S-RM (Extension stage 2)
Product advanteges
disposal connection
R 2 1/2, DIN 14308
filling unit with ball and high pressure filling unit with ball and
cleaning head pressure-reducing valve
nn NS 2 – 20 transport-friendly and easy pressure-reducing valve *
min 500
min 500
inspection depicted:
depicted:
installation because can be dismant- inspection door ventilation NS 7, operation side „right“, door NS 7, operation side „right“,
DN 100 for operation side „left“ the components
for operation side „left“ the components
led into separate components inlet
inlet
(inspection glass) are placed mirrow-inverted
(disposal connection, inspection glass, high
pressure pump) are placed mirrow-inverted
ventilation outlet
with reference to the middle axis of the DN ...
nn Optimal and easy cleaning thanks to DN ... outlet
DN ... separator. DN 100 DN ... with reference to the middle axis of the
separator.
inspection
round shape
ØD
inspection * not included in scope of delivery glass with * not included in scope of delivery
ØD
glass with a wiper
nn Project-specific special solutions reali-
H5
a wiper *
heating rod
H3
H5
sable with parallel modular extensions heating rod connection
H4
H1
H3
connection sleeve*
H1
H2
sleeve*
H2
Z
Z
ØD1 L3
ØD1 L3
L1
L1
Product informationen
L2
high pressure pump
L2
Table of dimensions
LipuJet-S-RD (Extension stage 1) LipuJet-S-RA (Extension stage 3)
NS DN Separator content Dimensions Extension dimensions
disposal connection disposal connection
Grease R 2½, DIN 14308 R 2 1/2, DIN 14308
filling unit with ball and high pressure filling unit with ball and
Sludge storage pressure-reducing valve* cleaning head pressure-reducing valve
min 500
min 500
inspection depicted: depicted:
trap volume Total H1 H2 H3 H4 L1 L2 L3 Z/n* D H5 L4 L5 D1 door ventilation NS 7, operation side „right“,
inspection door
NS 7, operation side „right“,
DN 100 for operation side „left“ the components for operation side „left“ the components
[l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] (disposal connection, inspection glass) are (disposal connection, control unit, inspection
52 inlet
DN ...
outlet inlet
placed mirrow-inverted with reference to the
DN ... ventilation outlet
glass, high pressure pump) are placed 53
2 100 210 120 715 975 905 1200 1400 1180 120 785/2 110 1520 250 110 1000 1020 inspection
DN ... middle axis of the separator. control unit DN 100 DN ...
mirrow-inverted with reference to the middle
axis of the separator.
glass with * not included in scope of delivery inspection
4 100 420 165 915 1240 1170 1450 1650 1180 120 785/2 110 1770 250 110 1000 1020
ØD
ØD
a wiper * glass with * not included in scope of delivery
a wiper
7 150 705 400 1950 1430 1330 1780 1930 1800 120 790/3 160 2100 250 110 1500 1660
H5
H5
heating rod heating rod
H3
H3
connection connection
H4
H4
H1
10 150 1000 400 2250 1600 1500 1950 2100 1800 120 790/3 160 2270 250 110 1500 1660
H1
sleeve* sleeve*
H2
H2
15 200 1630 800 3350 1755 1685 2120 2250 2050 120 820/3 210 2440 250 110 1750 1915
Z
20 200 2110 800 3820 1935 1885 2320 2450 2050 120 820/3 210 2640 250 110 1750 1915
ØD1 L3 ØD1 L3
*n = number of segments
L1 L1
4
L
www.aco-haustechnik.de/catalogue/Article no. L
5
L2
L2
high pressure pump
All digital contents (data sheets (PDF)), dimensional drawings (DXF, IGS) and article descriptions (Datanorm, GAEB, TXT) relating to the grease
separators and additional components represented here can be retrieved from the website stated above using the respective article number.
Product overview Product overview
inspection door
depicted:
NS 7, operation side „right“,
odours Convenience
for operation side „left“ the components
inlet
(disposal connection, control unit, inspection glass, LipuJet-S-RB
ventilation outlet high pressure pump) are placed mirrow-inverted with
DN ...
control unit DN 100 DN ... reference to the middle axis of the separator. (Basic model)
LipuJet-S-RB LipuJet-S-RD
inspection * not included in scope of delivery
NS Basic model Extension stage 1
ØD
glass with
nn Disposal and cleaning by opening the covers
a wiper
Article no. — —
(associated with the formation of noxious smells)
H5
heating rod
H3
connection
2 7502.32.00 7502.62.00
H4
H1
H2
4 7504.32.00 7504.62.00
disposal pump 7 7507.32.00 7507.62.00
Z
LipuJet-S-RM
nn Odour-free disposal via direct suction and automated inner
4
(Extension stage 2)
L
disposal connection
Article no. LipuJet-S-RMP
high pressure filling unit with ball
cleaning head and pressure-reducing
R 2 1/2, DIN 14308
2 7502.73.41 7502.73.31 7502.73.61 7502.73.51 (Extension stage 2 with disposal pump)
valve
min 500
depicted:
NS 7, operation side „right“,
4 7504.73.41 7504.73.31 7504.73.61 7504.73.51
inspection door
nn As before, but with additional disposal pump with free flow
(disposal connection, control unit,7 7507.73.41 7507.73.31 7507.73.61 7507.73.51
for operation side „left“ the components
inlet manual impeller (required for a total delivery head of over 6 metres)
DN ... ventilation outlet 10 to 7510.73.41
inspection glass, high pressure pump) are
placed mirrow-inverted with reference 7510.73.31 7510.73.61 7510.73.51
control unit DN 100 DN ...
the middle axis of the separator. nn Automated disposal and inner cleaning
inspection
15 7515.73.41 7515.73.31 7515.73.61 7515.73.51
ØD
heating rod
H3
54 connection
55
H4
H1
sleeve *
stop valve
H2
LipuJet-S-RA
nn Programmed, odour-free disposal/cleaning via direct suction
disposal pump (Extension stage 3)
and hydro-mechanic high-pressure inner cleaning
Z
ACO LipuJet-P-SB – split-design grease separators ACO LipuJet-P-SD – split-design grease separators
for free-standing installation for free-standing installation with direct suction extraction
min 500
min 500
Inlet Inlet
Outlet DN 100 Outlet
DN 100
DN 100 DN 100
Ø 110
Ø 110
1360
1360
1005
935
1005
935
56 57
a b
a b
L1
L1
L2
L2
700
700
NS Separator content Dimensions Weight Article no. NS Separator content Dimensions Weight Article no.
Sludge trap Grease storage volume Total L1 L2 a b empty full Sludge trap Grease storage volume Total L1 L2 a b empty full
[l] [l] [l] [mm] [mm] [mm] [mm] [kg] [kg] [l] [l] [l] [mm] [mm] [mm] [mm] [kg] [kg]
2 210 80 480 1180 1360 510 660 75 555 3802.00.00 2 210 80 480 1180 1360 510 660 75 555 3802.50.00
4 420 165 880 2070 2250 945 1115 115 995 3804.00.00 4 420 160 880 2070 2250 945 1115 115 995 3804.50.00
Product overview Product overview
ACO LipuJet-P-OB oval grease separator made of polyethylene ACO LipuJet-P-OD oval grease separator made of polyethylene
for free standing installation
n With two inspection windows for n With two inspection windows for
sludge and grease control sludge and grease control
n Optionally with filling device n Optionally with filling device
n Optionally with grease level sensor n Optionally with grease level sensor
n Grease separator plant according to EN 1825 n Two odour proof maintenance openings OD 450 mm n Grease separator plant according to EN 1825 n Inlet and outlet for plastic pipe connection
for free-standing installation in frost proof rooms n Inlet and outlet for plastic pipe connection for free-standing installation in frost proof rooms n Two inspection windows with wiper for grease and
n Manufactured of welded polyethylene in oval shape n Two inspection windows with wiper for grease and n Manufactured of welded polyethylene in oval shape sludge control
sludge control n Two odour proof maintenance openings OD 450 mm n Disposal connection OD 75 mm and coupling Storz
B R 2½"
58 59
L B H1 H2 H3 H4 L B H1 H2 H3 H4
[mm] [l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm]
15 200 1580 630 2850 3210 1340 1750 1640 1300 1230 3815.35.42 3815.35.32 15 200 1580 630 2850 3210 1340 1850 1640 1300 1230 3815.45.42 3815.45.32
20 200 2070 850 3760 3910 1340 1750 1640 1300 1230 3820.35.42 3820.35.32 20 200 2070 850 3760 3910 1340 1850 1640 1300 1230 3820.45.42 3820.45.32
25 200 2550 1070 4660 4610 1340 1850 1740 1300 1230 3825.35.42 3825.35.32 25 200 2550 1070 4660 4610 1340 1950 1740 1300 1230 3825.45.42 3825.45.32
30 250 3020 1290 5550 5310 1340 1850 1740 1300 1230 3830.35.42 3830.35.32 30 250 3020 1290 5550 5310 1340 1950 1740 1300 1230 3830.45.42 3830.45.32
ACO LipuJet-P-OA oval grease separator made of polyethylene ACO LipuJet-P-OAP oval grease separator made of polyethylene
for free standing installation for free standing installation
n With two inspection windows for n With two inspection windows for
sludge and grease control sludge and grease control
n With two high pressure spray heads n With two high pressure spray heads
for perfect inner body cleaning for perfect inner body cleaning
n Control unit with presets and flexible n Disposal pump for maximum lift
adjustments (cleaning and filling heights up to 18 meters with 10 m3/h
times) disposal performance
n Control unit with presets and flexible
adjustments (cleaning and filling
times)
Product informationen
n Grease separator plant according to EN 1825 n Disposal connection OD 75 mm and coupling Storz B R 2½"
for free-standing installation in frost proof rooms n Two automatically operated high pressure pumps 3,9 kW
n Manufactured of welded polyethylene in oval shape and high pressure spray heads with 150 bar for crushing and Product informationen
n Two odour proof maintenance openings OD 450 mm mixing of separator contents and cleaning of separator body
n Inlet and outlet for plastic pipe connection n Automatically operated filling device R ¾" (solenoid valve) n Grease separator plant according to EN 1825 n Automatically operated disposal pump 3,7 kW with shut-off
n Two inspection windows with wiper for grease and sludge n Electric connection 400 V / 50 Hz / 16 A / 7,8 kW for free-standing installation in frost proof rooms valve, disposal connection OD 75 mm and coupling Storz B
control n Manufactured of welded polyethylene in oval shape R 2 ½"
n Two odour proof maintenance openings OD 450 mm n Two automatically operated high pressure pumps 3,9 kW
n Inlet and outlet for plastic pipe connection and high pressure spray heads with 150 bar for crushing and
n Two inspection windows with wiper for grease and mixing of separator contents and cleaning of separator body
Dimensional drawing sludge control n Automatically operated filling device R ¾" (solenoid valve)
H1
H3
H2
n Electric connection 400 V / 50 Hz / 16 A / 11,5 kW
H4
Dimensional drawing
60 61
B2
B1
H1
H3
H2
H4
L
B2
B1
NS OD trap storage capacity Dimensions Article no. Article no. NS OD trap storage capacity Dimensions Article no. Article no.
ACO LipuJet-P-OAP oval grease separator made of polyethylene ACO LipuMobil-P type 0.8 (tested according to EN 1825) from polyethylene
for free standing installation
nn Each separator with two inspection nn Low inlet height for food truck con-
windows for sludge and grease nection
control nn Odoour-proof cover
nn Each separator with two high pressure nn Flexible connecting options
spray heads for perfect inner body nn Type tested according to EN 1825
cleaning nn Optionally with transportation wheels,
nn Each separator with disposal pump for grease storage tank or discharge valve
maximum lift heights up to 18 meters
with 10 m3/h disposal performance
nn Each separator with control unit with
presets and flexible adjustments (clea-
ning and filling times) Product informationen
nn For free-standing installation in frost-proof areas, odour- nn Grease storage volume: 15 liters
proof sealed, with removable cover and fastening ring nn Sludge storage volume: 16 liters
Product informationen nn Inlet and outlet DN 50 (OD 50 mm) for connection with nn Optionally with grease storage tank from PE, mounted
fitting pipe systems at the separator, with discharge pump, volume 10 liters
nn Grease separator plant according to EN 1825 nn Automatically operated disposal pump 3,7 kW with shut-off 1 2 nn Total volume: 48 liters
3 4 5 6 7 8 9 nn Type test report for flow rate (NS): 60143586-001
10 11 12
for free-standing installation in frost proof rooms valve, disposal connection OD 75 mm and coupling Storz B nn Suitable for flow rates up to 0.8 l/s
A A
nn In parallel installation, with distribution unit inlet OD 250 R 2½" for each separator
mm, piping and two manual valves between distribution nn Two automatically operated high pressure pumps 3,9 kW
unit and separators and high pressure spray heads with 150 bar for crushing and B B
nn Manufactured of welded polyethylene in oval shape mixing of separator contents and cleaning of separator body Dimensional drawing
nn Two odour proof (each separator) maintenance openings for each separator
OD 450 mm nn Automatically operated filling device R ¾" (solenoid valve)
H1
C C
H3
nn Inlet and outlet for plastic pipe connection for each separator
H2
H4
nn Two inspection windows (each separator) with wiper for nn Electric connection 400 V / 50 Hz / 16 A / 11,5 kW for each
grease and sludge control separator D D
504
300
270
L1
L2
Dimensional drawing E E
181 560
62 410 63
B2
F F
B1
598
H1
G G
H3
H2
B3
H4
modification:
L1
L2 With grease storage tank (operating side left) 3700.04.20
Table of dimensions
B2
B1
Operating
L B1 B2 B3 H1 H2 H3 H4 side right
[mm] [l] [l] [l] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
B2
B1
40 200 4140 1700 7520 3910 1530 1340 3500 2090 1640 1300 1230 3840.85.42
50 200 5100 2140 9320 4610 1530 1340 3500 2190 1740 1300 1230 3850.85.42
60 250 6040 2580 11100 5310 1530 1340 3500 2190 1740 1300 1230 3860.85.42
Product overview Product overview
nn Grease separator according to EN 1825 for partial nn Manufactured of polyethylen nn Grease separator according to EN 1825 for partial nn Manufactured of polyethylene
disposal of grease and sludge nn Inlet and outlet connections as per EN 877 with disposal of grease and sludge nn Inlet and outlet connections as per EN 877 with
nn For installation in frost-free premises OD 110 mm nn For installation in frost-free premises OD 110 mm
nn With integrated sludge trap nn With manual valves DN 50 for grease and sludge nn With integrated sludge trap nn With manual valves DN 50 for grease and sludge
extraction extraction
open pin B
387
Dimensional drawing inlet
Dimensional drawing 1099
DN100
outlet
DN100
inlet outlet
DN 100 DN 100
40
65 B
(70)
65
70
ca.1825
1979
ca.1607
1512
1764
1457
1442
1387
1581
1526
ca.1207
1511
1456
1364
1042
942
1022
50
100
80
ca.826 695
64 882
65
642
n110
n110
ca. 767
1399
1743
ACO Lipator-P-RM grease separator for partial disposal made of polyethylene ACO Lipator-S-RM grease separator for partial disposal made of stainless steel
for free standing installation for free standing installation
min. 300
min. 300
Product informationen Product informationen
nn Grease separator plant according to EN 1825 nn With extraction valves DN 50 for grease and sludge nn Grease separator plant according to EN 1825 nn With extraction valves DN 50 for grease and sludge
OD
OD
OD
DN Outlet Outlet
DN
OD
DN
nn Manufactured of welded polyethylene nn With heating rod and timer clock for homogenizing nn Manufactured of stainless steel, material grade 316 nn With heating rod andDNtimer clock for homogenizing
nn Inlet and outlet for plastic pipe connection of grease nn Inlet and outlet for plastic pipe connection of grease
nn Electric connection: 230 V, 50/60 Hz nn Electric connection: 230 V, 50/60 Hz
H
Dimensional drawing Dimensional drawing
H1
H1
H2
H2
min. 300
min. 300
OD
Inlet Inlet
OD
OD
DN Outlet C x E/ Ø D Outlet
DN
OD
DN DN
D
Ø
H
B
B
H1
H1
H2
H2
66 C° 67
L L
C x E/ Ø D
Table of dimensions
D
Table of dimensions
Ø
Inlet/outlet Largest single
B
B
ACO Lipator-P-RA grease separator for partial disposal made of polyethylene ACO Lipator-S-RA grease separator for partial disposal made of stainless steel
for free standing installation for free standing installation
min. 300
Product informationen Product informationen DN 100 DN 100
min. 300
nn Grease separator plant according to EN 1825 nn With hoses and four tanks 60 liters for grease and sludge nn Grease separator plant according to EN 1825 nn With hoses and four tanks 60 liters for grease and sludge
for free-standing installation in frost proof rooms collection for free-standing installation in frost proof rooms collection
OD
Inlet
nn Manufactured of welded polyethylene nn With agitating device and scraper nn Manufactured of stainless steel, material grade 316 nn With agitating device and scraper
OD
OD
DN
Outlet
OD
nn Inlet and outlet for plastic pipe connection nn With heating rod and timer clock for homogenizing
DN nn Inlet and outlet for plastic pipe connection nn With heating rod and timer clock for homogenizing
nn With automated grease and sludge extraction of grease nn With automated grease and sludge extraction of grease
nn Electric connection: 230 V, 50/60 Hz nn Electric connection: 230 V, 50/60 Hz
H
H
H1
H2
H1
H2
min. 300
min. 300
730
730
DN 100 DN 100
(OD = 110 mm) (OD = 110 mm)
Inlet
Ø400 Ø400
OD
DN
OD
Outlet
OD
OD
DN
L
D
D
Ø
Ø
68 69
H
H
B
H1
H2
B
H1
C°
H2
730
730
Ø400 L
Ø400
L
Table of dimensions Table of dimensions
D
Ø
D
Ø
NS OD Dimensions component Article no. NS OD Dimensions component Article no.
B
L B ØD H H1 H2 ØDxH L B C ØD H H1 H2 ØDxH
B
C°
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [°] [mm] [mm] [mm] [mm] [mm]
4 110 1950 1350 1060 1850 1400 1330 Ø 1270 x 860 3574.70.10 2 110 1170 970 115 640 1700 1300 1230 Ø 750 x 880 7672.70.10
10 160 250 1850 1530 2320 1800 1730 Ø 1660 x 660 3580.70.10 4 110 1240 1300 45 980 1850 1400 1330 Ø 980 x 450 7674.70.10
20 200 2750 2050 1780 2560 1900 1830 Ø 1920 x 700 3590.70.10 10 160 1710 1670 45 1500 2200 1800 1730 Ø 1500 x 650 7680.70.10
L
25 200 2750 2050 1780 2660 2000 1930 Ø 1920 x 700 3595.70.10 20 200 1950 1880 45 1750 2320 1900 1830 Ø 1750 x 780 7690.70.10
25 200 1950 1880 45 1750 2420 2000 1930 Ø 1750 x 780 7695.70.10
Supplementary components Supplementary components
Product Designation To fit Description Article no. Product Designation To fit Description Article no.
nn For electronic measurement of grease layer nn LipuSmart-P-OB, nn Free outlet according to DIN 1988 Part 4
nn Suitable for liquid and/or congealing grease -OD nn For connection to drinking water supply
3300.11.22
nn LipuSmart-P
nn Measuring device with cable, length: 3 m nn LipuJet-P-OB, -OD, nn With ball valve R ¾"
oo Oval NS 1 – 10
nn With two isolated change-over contacts to display -RB, -RD nn With pressure relief valve
nn LipuJet-P
Grease level full warning (80%) and advance warning of fill
oo Oval NS 1 – 10 nn Free outlet according to DIN 1988 Part 4
sensor level (50%) 3300.11.50
oo Round NS 2 – 20 nn LipuJet-S-OB, -OD, nn For connection to drinking water supply
Classic nn With visual display of fill level Filling device 7602.00.25
nn LipuJet-S -RB, -RD nn With ball valve R ¾"
nn With heated probe rod to increase operating
oo Oval NS 1 – 10 nn With pressure relief valve
reliability
oo Round NS 2 – 20
nn Operating voltage: 230 VAC/5 VA nn Free outlet according to DIN 1988 Part 4
nn Max. consumption: 12 W nn For connection to drinking water supply
nn LipuJet-P-SB, -SD 0153.06.76
nn To determine the disposal intervals of grease nn With ball valve R ¾"
separators nn With pressure relief valve
nn Suitable for liquid and/or harden fats
nn LipuSmart-P-OA, nn For inside assembly or mounting in connection
nn Delineation with colour-touchpanel
-OAP boxes
nn LipuSmart-P nn Continuous measure in percent
nn With integrated SD-card (4GB) for recording of nn LipuJet-P-OA, -OAP, nn Control line without local protective conductor
oo Oval NS 1 – 10 Remote 0150.59.89
the measuring process -RA, -RAP oo Up to 50 m: 7 x 1.0 mm²
nn LipuJet-P control
Grease level nn With heated sounding stick (temperature is LipuJet-S-OA, -OAP, - oo 50 – 200 m: 7 x 1.5 mm²
oo Oval NS 1 – 10
sensor adjustable) to increase the operation safety 3300.12.50 RA, -RAP nn IP 54 protection type
oo Round NS 2 – 20
Comfort nn Three free of potential contacts for outoput of LipuMax-P-DA nn Weight: 1 kg
nn LipuJet-S pre-alarm (adjustable), full-alarm (adjustable)
oo Oval NS 1 – 10 and error
oo Round NS 2 – 20 nn Measuring stick with adjusting scale nn For internal fitting or fitting in connection boxes
nn Delineation with plug-in cable connection, 3 m nn Control line without protective conductor on-site
Remote nn LipuJet-P-OA, -OAP 0150.37.58
nn Service voltage: 100 240VAC 50/60 Hz, 2 A oo Up to 50 m: 7 x 1.0 mm²
control oo Oval NS 15 – 30
nn Power: ca. 43 W oo 50 – 200 m: 7 x 1.5 mm²
nn Mains-independent
nn For disposal connection and remote control
nn Visible and audible alarm signals
nn Made of stainless steel, material grade 304
nn 6 digital & 2 analogue freely configurable inputs Connection 7601.80.20
nn Grease separators nn Fixing: "on-wall"
nn 1 alarm output 12 V box
nn Dimensions (width x height x depth):
nn Includes GSM antenna (2.5 m cable)
Signalling nn Grease separators 500 x 500 x 160 mm
nn Relaying alarms to mobile phones by SMS 0150.46.94
unit with GSM extension stage 3
nn For mounting outside the ex area nn Made of stainless steel, material grade 304
module nn Grease level sensor nn Connection box
nn Housing: 155 x 180 x 103 mm In-wall frame nn Dimensions (width x height x depth): 7601.80.21
oo 7601.80.22
nn Slot for standard SIM card 421 x 381 x 25 mm
70 71
nn Protection type: IP 54 (with mounted antenna
nn LipuSmart-P-OB,
plug IP 44) nn Nominal width: DN 200
Inspection -OD 3300.11.10
nn Operating voltage: 230 V/AC 50/60 Hz nn With wiper
window nn LipuJet-P-OB, -OD,
nn Weight: 5 kg
-R, -RD
nn To liquefy grease layer
nn Nominal width: DN 200
nn Incl. control 7300.01.00 Inspection nn LipuJet-S-OB, -OD, 7602.00.26
Heating rod nn Grease separators nn With wiper
nn Electrical connection window -R, -RD
nn Weight: 5 kg
oo 400 V/50 Hz/16 A/6.0 kW
Supplementary components Supplementary components
Product Designation To fit Description Article no. Product Designation To fit Description Article no.
nn For installation in horizontal pipelines DN 100 nn Made of stainless steel, material grade 316
downstream of separator plants nn Round shape
nn Material: PE nn Gradient: 70 mm
nn LipuJet-P/Lipa- nn LipuJet-S/ Lipa-
Sampling pot nn Round shape with 3300.09.11 Sampling pot nn For installation in horizontal pipelines DN 100
tor-P-RM, -RA tor-S-RM, -RA 7300.09.10
DN 100 oo Coupling socket seal (material SBR) on inlet DN 100 downstream of separator plants
oo NS 1 – 4 oo NS 1 – 4
and spigot on outlet nn With pipe connector and claw
oo Odour-proof maintenance opening DN 450
nn Connections according to EN 877
nn Weight: 7 kg
nn Weight: 13 kg
nn For installation in horizontal pipelines DN 150
nn Made of stainless steel, material grade 316
downstream of separator plants
nn Round shape
nn LipuJet-P nn Material: PE
oo NS 5.5 – 10
nn Gradient: 70 mm
Sampling pot nn Round shape with 3300.09.21 nn LipuJet-S/ Lipa-
DN 150 nn Lipator-P-RM, -RA
Sampling pot nn For installation in horizontal pipelines DN 150 7300.09.20
oo Coupling socket seal (material SBR) on inlet tor-S-RM, -RA
oo NS 7 – 10 and spigot on outlet DN 150 downstream of separator plants
oo NS 5.5 – 10
oo Odour-proof maintenance opening DN 450 nn With pipe connector and claw
nn Weight: 7 kg nn Connections according to EN 877
nn Weight: 14 kg
nn For installation in horizontal pipelines DN 200
downstream of separator plants nn Round shape
nn Material: PE nn Gradient: 70 mm
nn LipuJet-P/Lipa-
Sampling pot nn Round shape with 3300.09.31 nn LipuJet-S/ Lipa- nn For installation in horizontal pipelines DN 200
tor-P-RM, -RA Sampling pot
DN 200 oo Coupling socket seal (material SBR) on inlet tor-S-RM, -RA downstream of separator plants 7300.09.30
oo NS 15 – 25 DN 200
and spigot on outlet oo NS 15 – 25 nn With pipe connector and claw
oo Odour-proof maintenance opening DN 450
nn Connections according to EN 877
nn Weight: 7 kg nn Weight: 15 kg
nn For installation in vertical pipelines DN 100 nn Made of stainless steel, material grade 316
downstream of separator plants
nn Round shape
nn Material: PE
nn LipuJet-P/Lipa- nn LipuJet-S/ Lipa- nn For installation in vertical pipelines DN 100
Sampling pot nn Round shape with 3300.10.11 Sampling pot 7300.10.20
tor-P-RM, -RA tor-S-RM, -RA downstream of separator plants
DN 100 oo Coupling socket seal (material SBR) on inlet DN 100
oo NS 1 – 4 oo NS 1 – 4 nn With pipe connector and claw
and spigot on outlet
oo Odour-proof maintenance opening DN 450
nn Connections according to EN 877
nn Weight: 7 kg nn Weight: 13 kg
nn For installation in vertical pipelines DN 150 nn Made of stainless steel, material grade 316
downstream of separator plants nn Round shape
nn LipuJet-P nn Material: PE nn LipuJet-S/ Lipa- nn For installation in vertical pipelines DN 150
Sampling pot 7300.15.20
Sampling pot oo NS 5.5 – 10 nn Round shape with tor-S-RM, -RA downstream of separator plants
72 3300.10.21 DN 150 73
DN 150 nn Lipator-P-RM, -RA oo Coupling socket seal (material SBR) on inlet oo NS 5.5 – 10 nn With pipe connector and claw
oo NS 7 – 10 and spigot on outlet nn Connections according to EN 877
oo Odour-proof maintenance opening DN 450 nn Weight: 14 kg
nn Weight: 7 kg
nn Made of stainless steel, material grade 316
nn For installation in vertical pipelines DN 200 nn Round shape
downstream of separator plants nn LipuJet-S/ Lipa- nn For installation in vertical pipelines DN 200
nn Material: PE Sampling pot 7300.16.20
nn LipuJet-P/ tor-S-RM, -RA downstream of separator plants
Sampling pot nn Round shape with
DN 200
3300.10.31 oo NS 15 – 25 nn With pipe connector and claw
nn Lipator-P-RM, -RA
DN 200 oo Coupling socket seal (material SBR) on inlet nn Connections according to EN 877
oo NS 15 – 25
and spigot on outlet
nn Weight: 15 kg
oo Odour-proof maintenance opening DN 450
nn Weight: 7 kg
Supplementary components Supplementary components
Product Designation To fit Description Article no. Product Designation To fit Description Article no.
n Made of PVC
n Polyethylene n 50 mm push socket on both sides with lip seal
Inlet valve Shut-off valve n LipuMobil-P 0.8 n Shut-off valve DN 50 for inlet pipe 0175.18.33
separators n Overall dimensions: 290 x 740 mm 0170.20.83
DN 200 o NS 15 – 25 n Weight: 9.5 kg
n 2 drums
o Complete with hoses
o Capacity 60 liters
o With Plexiglas cover
o With clamping ring and hose connection 0170.30.35
Drums
DN 25 and DN 40
o 2 hoses DN 25 (length 2,500 mm) and 2 hoses
DN 40 (length 1,500 mm)
n 2 replacement drums 60 liters with cover and
clamping ring only
4 Process optimisation
Process optimisation
Grease separator plants
740
603
nn Touch panel oo Maximum lifting performance 300 l/min.
oo 7" colour touch panel oo Maximum lifting height 10 metres
oo Process display oo Power consumption 0.35 kW
oo Inspection and setting of parameters oo Protection class IP 55
nn Controls
oo In-situ power supply 230 V/50 – 60 Hz/16 A
oo IP 54 protection type
oo Potential free contact for operation and fault report
Dimensional drawing nn Dosing liquid 125 kg
Designation To fit Weight Article no.
Circulation pump LipuFloc Circulation shaft lower part (construction phase #1)
78 [kg] 79
70
930
770
200
120
Ø480
1.450
500 x 300
Circulation unit below ground
R 3/4
50
230
ca. 1070
380 140
ca. 1300
200
Ø160 (DN 150)
Ø210 (DN 200)
Ø110 (DN 100)
Operating reliability
Lif ting Plants
80 81
Lifting plants Lifting plants
ACO lifting plants for grease separators ACO lifting plants for grease separators
NS 15 and 20 NS 25 and 30
Muli Pro-PE K-15 parallel lifting plant for pressure tubing made of plastic or SML with external
for installation downstream of grease separators diameter from 108 to 114.3 mm
n Two pumps 400 V, 50 Hz, IP 68 protection type (for
n Two polyethylene tanks with a drain plug or connec- performance data, see diagram on next page), with air Muli Pro-PE K XL lifting plant n Two pumps 400 V, 50 Hz, IP 68 protection type, both
tion for a manual membrane pump R 1½", fixing kit for bubble injection for maximum operational safety for installation downstream of grease separators pumps with piping and with two stop valves each
buoyancy safety n Switching device with warning device IP 54 protection n Pneumatic switching system with air bubble injection for
n Total volume: 1040 litres type with digital display, for alternate operation of the n Polyethylene tank with fixing kit for in-situ anchorage to maximum operational safety
n Operating volume depending on the inlet height selec- two pumps, with 1.5 metre cable and CEE plug 16 A prevent upwelling n Multi Control switching device IP 54 protection type
ted, various inlets Ø 160 mm at various positions (from 4 kW, 32 A), with isolated contact for group alarm n Inlet connection Ø 200 mm (selectable position), ven- with digital display for alternate operation of the two
n Two inspection openings, clear width 320 mm, ventila- to central technical supervision, with 7 metres of cabling tilation connection Ø 110 mm for connecting pressure pumps, with 1.5 metre cable and CEE plug 16 A, wired
tion line Ø 110 mm, discharge pressure line connection between lifting plant and switching device tubing from 114.3 mm and ready to plug in, with isolated contact for group
n Flexible container dimensions according to the table alarm and operating signal, with 10 metres of cabling
below, corresponding operating volume between switching device and lifting plant
Dimensional drawing
Stop valve
DN 80 (x DN 100) inlet socket
82 DN 150
83
95
-accessories-
K-30 3.0 420 3590.70.10 *
*190
180
*ca. 1530
ca. 1410
H1
k-75 7.5 510
940
H4
100 95
800
750
H3
600
H2
258
65
120
emergency power
780
780
supplies "ALARM 1"
motor cable connection
(4m long) mini compressor
mini compressor
for air bubble injection
Flaps for
buoyancy control
connection R 1 ½ maintenance opening *
for manual membrane LW 320 L2
pump
L1
L1 L2 H1 H2 H3 H4
[mm] [mm] [mm] [mm] [mm] [mm]
Article no./price
Muli Pro-PE K XL 2260 – 3110 1150 – 2000 Approx. 1475 375 – 1325 560 – 1510 722 – 1672
on demand
Lifting plants Lifting plants
Lifting plants for installation downstream of grease separators for free-standing installation
Product Designation To fit Description Article no. Product Designation To fit Description Article no.
Note:
To increase operating reliability, if this product is used we
recommend equipping the plant with air bubble injection
downstream of grease separators.
Supplementary components
n Polyethylene tank
n Usable volume 65 – 185 litres Product Designation To fit Description Article no.
n Two pumping sets IP 68
n Operating voltage 400 volts
n For retro-fitting on Muli-Mini and Muli-Star DDP
n Pneumatic level switching
wastewater lifting plants
n Pressure connection for pressure tubing n Muli-Mini duo
Air bubble n With min compressor and connectors
Ø 108 – 114.3 mm n Muli-Star DDP 3700.04.30
injection n To increase operational safety
n Inlet socket: DN 100/150/200
n To deal with generation of floating layers
n Ventilation socket DN 70/100
(wastewater containing grease)
n For separators n Container dimensions (L x W x H):
Muli-Star DDP up to NS 15 920 mm x 770 mm x 690 mm
n Empty weight: 104 – 128 kg
84 85
DDP 1.1 (P2 = 1.5 kW) 1202.00.01
DDP 1.2 (P2 = 3.0 kW) 1202.00.02
1202.00.04
DDP 2.1 (P2 = 1.5 kW) 1202.00.05
DDP 2.2 (P2 = 3.0 kW)
Note:
To increase operating reliability, if this product is used we
recommend equipping the plant with air bubble injection
downstream of grease separators.
ACO grease separators and BIM ACO grease separators and BIM
Ac
ce
ss
or
ie
s
Detailed image 1 Detailed image 2
Ex
te
Overviews of the complete Revit packet for ACO grease The example shows the Revit model of the ACO grease
ns
io
n
st
ag
e
separators are grouped according to extension stage. The separator LipuJet-S-OAP (extension stage 3 with disposal
3
product overview, including characteristics such as GTIN, pump) made from stainless steel with all connection faci-
article number etc. is located on the right-hand part of the lities. On the left-hand part of the screen you can see the
Ex
te
ns
io
LipuJet-P-OB NS1 basic oval such as sludge trap, etc. The switch box is specifically mar-
ked as an electronic component.
Ex
te
ns
io
n
st
ag
e
1
Ba
si
c
Li
pu
Je
t-
P-
R�
Li xt
pu en
(E
Sm sio
ar n s
t- t a
P- g
O e
Li
AP 3)
pu
Je
t-
Li xt
P-
pu en
SB
(E
Sm sio
ar n s
t- t a
P- g
O e
A 3)
Li
pu
Li xt
pu en
Je
(E
t-
Sm sio
S-
ar n s
O
t- t a
P- g
O e
D 1)
Li as
t-
Revit model of a sampling pot including connection The properties of the product are displayed in this box -
pu ic
S-
(B
R�
Sm )
ar
t
-P
-O
facilities. this is where you can also find the link to the ACO Online
86 87
Catalogue and the accompanying data sheet.