DESIGN OF CONCRETE COLUMN SEISMIC DETAILING Structural Excell Program

Material Properties Reinforcement Details


Concrete f'c = 20.7 MPa Along x = 3 pcs Corner Rebar = Ø16 mm
Reinforcing fy = 414 MPa Along y = 3 pcs Side Rebar = Ø16 mm
Es = 200000 MPa Cover = 40 mm
εcu = 0.003 r = As/(b*h) = 2.57 %

Section Properties
Width = 250 mm Stirrup fy = 276 MPa Spacing Tie = 100 mm
Height = 250 mm Stirrup bar = 10 mm Confinement = 75 mm
Length = 2.97 m

NSCP2015 Sec 418.7.2 - Dimensional limits


NSCP2015 Sec 418.7.2.1 Columns shall satisfy (a) and (b)
(a) The shortest cross-sectional dimension, measured on a straight line passing through the
geometric centroid, shall be at least 250 mm
Minimum Dimension = 250 mm Code Complaint
(b) The ratio of the shortest cross - sectional dimension to the perpendicular dimension
shall be at least 0.4
Dimension Ratio: 1% Code Complaint

NSCP2015 Sec 418.7.4 - Longitudinal Reinforcement


NSCP2015 Sec 418.7.4.1
Area of longitudinal reinforcement, Ast, shall be at least 0.01Ag and shall not exceed 0.06Ag.
Reinforcement Ratio: 2.57% Code Complaint

NSCP2015 Sec 418.7.5 - Transverse Reinforcement


NSCP2015 Sec 418.7.5.1 Length ℓo shall be at least the greatest of(a) through(c)
(a) The depth of the column at the joint face orsection where flexural yielding is likely to occur
(b) One-sixth of the clear span of the column
(c) 450 mm

NSCP2015 Sec 418.7.5.2 Transverse reinforcement shall be in accordance with(a) through(f)


(a) Transverse reinforcement shall comprise either single or overlapping spirals, circular hoops, or single or over lapping rectilinear hoops
with or without crossties.
(b) Bends of rectilinear hoops and crossties shall engage peripheral longitudinal reinforcing bars.
(c) Crossties of the same or smaller bar size as the hoops shall be permitted, subject to the limitation of 25.7.2.2. Consecutive crossties shall
be alternated end for end along the longitudinal reinforcement and around the perimeter of the cross section.
(d) Where rectilinear hoops or crossties are used, they shall provide lateral support to longitudinal reinforcementin accordance with 25.7.2.2 and 25.7.2.3.
(e) Reinforcement shall be arranged such that the spacing hx of longitudinal bars laterally supported by the corner ofa crosstie or hoop leg shall
not exceed 350 mm around the perimeter of the column.
(f) Where Pu > 0.3Ag fc′ or fc′ > 70 MPa in columns with rectilinear hoops, every longitudinal bar or bundle of bars around the perimeter of the
column core shall have lateral support provided by the corner of a hoop or by a seismic hook, and the value of hx shall not exceed 200 mm.
Pu shall be the largest value in compression consistent with factored load combinations including E.
Limit Leg Spacing : 350mm
Leg Spacing Along X: 67mm Code Complaint
Leg Spacing Along Y: 67mm Code Complaint

NSCP2015 Sec 418.7.5.3 Spacing of transverse reinforcement shall not exceed the least of(a) through(d):
(a) One-fourth of the minimum column dimension
(b) For Grade 420, 6db of the smallest longitudinal bar
(c) For Grade 550, 5db of the smallest longitudinal bar
(d) so, as calculated by s_o = 100 + (350-hx)/3
Maximum Spacing Limit Inside Lo : 62.5mm
Actual Spacing inside Lo: 75mm Non-Code Complaint

NSCP2015 Sec 418.7.5.4 Amount of transverse reinforcement shall be in accordance with Table 418.7.5.4
The concrete strength factor kf and confinement effectiveness factor kn are calculated according to Eq. (418.7.5.4a) and (418.7.5.4b).

(a) kf = ( fc / 175 ) + 0.6 ≥ 1.0 = 1


(b) kn = n1 / ( n1 - 2 ) = 1.33333333333333

where n1 is the number of longitudinal bars or bar bundles around the perimeter of a column core with rectillinear hoops that are laterally supported
by the corner of hoops or by seismic hooks.
Required # Leg Along X : 4pcs Actual # Leg Along X : 3pcs Non-Code Complaint
Required # Leg Along Y : 4pcs Actual # Leg Along Y : 3pcs Non-Code Complaint

NSCP2015 Sec 418.7.5.5 Hoops / Ties Beyond Lo


Beyond the length Lo given in Section418.7.5.1, the column shall containspiral or hoop reinforcement satisfying Sections 425.7.2 through 425.7.4
with spacing, s, not exceeding the smaller of six times the diameter of the smallest longitudinal column bars and 150mm, unless a larger
amount of transverse reinforcement is required by Section 418.7.4.3 or 418.7.6.
Required Spacing beyond Lo : 96mm Actual Spacing beyond Lo : 100mm Non-Code Complaint