Count Description
1 NK 125-400/392 AA1F2BESBAQEUW3

Product photo could vary from the actual product


Product No.: 98318214

Non-self-priming, single-stage centrifugal pump designed according to ISO 5199 with dimensions and rated
performance according to EN 733. Flanges are PN 16 with dimensions according to EN 1092-2. The pump has an
axial suction port, a radial discharge port and horizontal shaft. It is of the back pull-out design enabling removal of
the motor, coupling, bearing bracket and impeller without disturbing the pump housing or pipework.

The pump is fitted with a foot-mounted, fan-cooled asynchronous motor. Pump and motor are mounted on a
common base frame.

Further product details


Pump and motor are mounted on a common steel base frame in accordance with ISO 3661. The back pull-out
design makes it possible to make service on the pump when the pump housing is still connected to the inlet and
discharge pipes.
1) Remove the bolts in the bearing bracket support foot and motor foot.
2) Remove the bearing bracket and the motor from the pump housing.

Cast-iron parts have an epoxy-based coating made in a cathodic electro-deposition (CED) process.
CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint
particles as a thin, well-controlled layer on the surface.
An integral part of the process is a pretreatment.
The entire process consists of these elements:
1) Alkaline-based cleaning.
2) Zinc phosphating.
3) Cathodic electro-deposition.
4) Curing to a dry film thickness 18-22 my m.
The colour code for the finished product is NCS 9000/RAL 9005.

Pump
The pump housing has both a priming and a drain hole closed by plugs.
The impeller is a closed impeller with double-curved blades with smooth surfaces. The impeller is statically
balanced according to ISO 1940-1 class G6.3 and hydraulically balanced to compensate for axial thrust.
Wear rings used in pump housing and for impeller are made of bronze/brass.
The pump is fitted with an unbalanced rubber bellows seal with torque transmission across the spring and around
the bellows. Due to the bellows, the seal does not wear the shaft, and the axial movement is not prevented by
deposits on the shaft.
Primary seal:
• Rotating seal ring material: carbon graphite, metal-impregnated
• Stationary seat material: silicon carbide (SiC)
This material pairing has a very good corrosion resistance and is especially suitable for water up to 120 °C.

Printed from Grundfos Product Center [2022.10.006] 1/8


Company name:
Created by:
Phone:

Date: 3/2/2022
Count Description
However, seal life will be reduced at temperatures above 90 °C.
The material pairing is not recommended for liquids containing particles as this will result in heavy wear on the SiC
face.
Secondary seal material: EPDM (ethylene-propylene rubber)
EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils.
The shaft is made of stainless steel and has a diameter of 1.65 in where the coupling is mounted.
The pump uses a standard coupling between the pump and motor shaft.

Motor
The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards and mounting
designation B3 (IM 1001). Electrical tolerances comply with IEC 60034.

The motor efficiency is classified as IE3 in accordance with IEC 60034-30-1.


The motor has thermistors (PTC sensors) in the windings in accordance with DIN 44081/DIN 44082. The protection
reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions.
Thermal switches must be connected to an external control circuit in a way which ensures that the automatic reset
cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to local
regulations.

A variable speed drive makes adjustment of pump performance to any duty point possible. If the motor is to be
connected to a variable speed drive, the pump must be ordered with an electrically insulated motor bearing.

Technical data

Controls:
Frequency converter: NONE
Pressure sensor: N

Liquid:
Pumped liquid: Water
Liquid temperature range: 32 .. 248 °F
Selected liquid temperature: 68 °F
Density: 62.29 lb/ft³

Technical:
Rated pump speed: 1480 rpm
Rated flow: 1170 US gpm
Pump with motor (Yes/No): Y
Rated head: 164.4 ft
Actual impeller diameter: 15.4 in
Nominal impeller diameter: 400
Code for shaft seal: BAQE
Mechanical seal type: Single
Curve tolerance: ISO9906:2012 3B
Bearing design: Standard

Materials:
Pump housing: Cast iron
EN-GJL-250

Printed from Grundfos Product Center [2022.10.006] 2/8


Company name:
Created by:
Phone:

Date: 3/2/2022
Count Description
ASTM class 35
Wear ring: Brass
Impeller: Bronze
CuSn10-C
Internal pump house coating: CED
Shaft: Stainless steel
EN 1.4301
AISI 304

Installation:
t max amb: 131 °F
Maximum operating pressure: 232.06 psi
Pipe connection standard: EN 1092-2
Type of inlet connection: DIN
Type of outlet connection: DIN
Size of inlet connection: DN 150
Size of outlet connection: DN 125
Pressure rating for connection: PN 16
Coupling type: Flexible w/o spacer
Base frame design: EN/ISO
Code for base frame: 9B ST
Grouting (Yes/No): N

Electrical data:
Motor type: SIEMENS
IE Efficiency class: IE3
Rated power - P2: 75 HP
Main frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
Rated current: 96/56 A
Starting current: 680-680 %
Cos phi - power factor: 0.87
Rated speed: 1482 rpm
IE efficiency: IE3 94,6%
Motor efficiency at full load: 94.6-94.6 %
Motor efficiency at 3/4 load: 95.1-95.1 %
Motor efficiency at 1/2 load: 95-95 %
Number of poles: 4
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F
Motor Number: 98957823
Bearing insulation type N-end: STEEL BEARING

Others:
Minimum efficiency index, MEI ≥: 0.50
Net weight: 2020 lb
Gross weight: 2220 lb
Shipping volume: 70.3 ft³

Printed from Grundfos Product Center [2022.10.006] 3/8


Company name:
Created by:
Phone:

Date: 3/2/2022

98318214 NK 125-400/392 AA1F2BESBAQEUW3 50 Hz


H NK 125-400/392, 3*400 V, 50Hz eta
[ft] [%]
Pumped liquid = Water
Liquid temperature during operation = 68 °F
Density = 62.29 lb/ft³

200

15.4 in
180

160

140

120

100 100

80 80

60 60

40 40

20 20

0 0
0 200 400 600 800 1,000 1,200 1,400 Q [US gpm]
P NPSH
[HP] [ft]
80 P1 40

70 P2 35

60 30

50 25

40 20

30 15

20 10

10 5

0 0

Printed from Grundfos Product Center [2022.10.006] 4/8


Company name:
Created by:
Phone:

Date: 3/2/2022
H NK 125-400/392, 3*400 V, 50Hz eta
Description Value [ft] [%]
Pumped liquid = Water
General information: Liquid temperature during operation = 68 °F
Product name: NK 125-400/392 200
Density = 62.29 lb/ft³
AA1F2BESBAQEUW3
15.4 in
Product No.: 98318214 180
EAN: 5711492945964
160
Price:
Technical: 140
Rated pump speed: 1480 rpm
120
Rated flow: 1170 US gpm
Pump with motor (Yes/No): Y 100 100
Rated head: 164.4 ft
Actual impeller diameter: 15.4 in 80 80

Nominal impeller diameter: 400


60 60
Shaft diameter: 1.65 in
Code for shaft seal: BAQE 40 40
Mechanical seal type: Single
20 20
Curve tolerance: ISO9906:2012 3B
Pump version: A1 0 0
0 500 1,000 Q [US gpm]
Bearing design: Standard
P NPSH
Materials: [HP]
P1
[ft]
Pump housing: Cast iron 70 35
P2
Pump housing: EN-GJL-250
60 30
Pump housing: ASTM class 35
50 25
Wear ring: Brass
40 20
Impeller: Bronze
30 15
Impeller: CuSn10-C
20 10
Internal pump house coating: CED
Material code: B 10 5

Code for rubber: E 63.90


0 0
26.40
28.70

23.60

11.80 40.30
=
16.30

32.50
15.70 3.94

4.33
6
x
1.10
5.91

0.75
0.91
x
8

4.92
5.51 61.10

Shaft: Stainless steel


Shaft: EN 1.4301
61.10

Shaft: AISI 304 5.51 5.51 4.92


8 x 0.75

Installation:
8 0.91
t max amb: 131 °F
15.70

x
5.91

Maximum operating pressure: 232.06 psi


32.50

Pipe connection standard: EN 1092-2


16.30
3.94

Type of inlet connection: DIN 4.33


1.10
Type of outlet connection: DIN 6 x

Size of inlet connection: DN 150


23.60

26.40

28.70

Size of outlet connection: DN 125


Pressure rating for connection: PN 16
= =

Coupling type: Flexible w/o spacer 11.80 40.30 11.80

63.90
Base frame design: EN/ISO
Code for base frame: 9B ST
Grouting (Yes/No): N
Connect code: F
Liquid:
Pumped liquid: Water +T +T +T

Liquid temperature range: 32 .. 248 °F


Selected liquid temperature: 68 °F
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Density: 62.29 lb/ft³ TO AMPLIFIER


RELAY

Electrical data: L1 L2 L3

Motor type: SIEMENS


THERMISTORS PTC ACCORDING TO DIN 44082

IE Efficiency class: IE3


+T +T +T

Rated power - P2: 75 HP


Main frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
TO AMPLIFIER

Rated current: 96/56 A RELAY


L1 L2 L3

Printed from Grundfos Product Center [2022.10.006] 5/8


Company name:
Created by:
Phone:

Date: 3/2/2022
Description Value
Starting current: 680-680 %
Cos phi - power factor: 0.87
Rated speed: 1482 rpm
IE efficiency: IE3 94,6%
Motor efficiency at full load: 94.6-94.6 %
Motor efficiency at 3/4 load: 95.1-95.1 %
Motor efficiency at 1/2 load: 95-95 %
Number of poles: 4
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F
Built-in motor protection: PTC
Motor Number: 98957823
Bearing insulation type N-end: STEEL BEARING
Controls:
Frequency converter: NONE
Pressure sensor: N
Others:
Minimum efficiency index, MEI ≥: 0.50

Net weight: 2020 lb


Gross weight: 2220 lb
Shipping volume: 70.3 ft³

Printed from Grundfos Product Center [2022.10.006] 6/8


Company name:
Created by:
Phone:

Date: 3/2/2022

98318214 NK 125-400/392 AA1F2BESBAQEUW3 50 Hz

15.70 16.30

3.94
0.75
8 x
4.92

0.91
8x

28.70

32.50 26.40
5.51

11.80
1.10

=
6x

40.30

63.90
61.10

=
4.33

11.80
5.51

23.60
5.91

Note! All units are in [in] unless otherwise stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Center [2022.10.006] 7/8


Company name:
Created by:
Phone:

Date: 3/2/2022

98318214 NK 125-400/392 AA1F2BESBAQEUW3 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

All units are [in] unless otherwise presented.

Printed from Grundfos Product Center [2022.10.006] 8/8