You are on page 1of 1
EYAS, MARLOU LOCATION. RATINGS 201812074 a. DRY : TYPICALLY APPLIES TO CONDUCTORS THAT ARE ENCLOSED IN A BUILDING AND 1. WITH RESPECT TO CONDUCTOR, REMAIN ORY EXCEPT DURING INITIAL INSULATION , INTERPRET THE FF. CONSTRUCTION INSULATION DESIGNATIONS * b. DAMP: INCLUDED WIRING IN ABOVE “GROUND, a. T: THERMOPLASTIC INSULATION PROTECTED OUTDOOR LOCATIONS SUCH b.N: NYLON JACKETED A IN COVERED OPEN DECKS ADD cH: HEAT RESISTANT ; TEMPERATURE © CANOPIES RATED AT 1G3°F (95°C) cc. WET © CONDUCTOR 1d EXPOSED TO od. HH: EXTRA HEAT RESISTANT ; WEATHER OR EXPOSED TO SEVERE TEMPERATURE RATED AT 194°F MOISTURE CONDITIONS e.W: MOISTURE RESISTANT 4. FROM TABLES PROVIDED IN CHAPTER 18 , IDENTIFY 2. WITH RESPECT TO CONDUCTORS , —THE AMPACITY OF THE FOLLOWING CONDUCTORS INTERPRET THE FF. DESIGNATIONS: a. NO. 12 AWG COPPER CONDUCTOR WITH THWN a. THHN : THERMOPLASTIC . 194°F TEMPE- INSULATION AND A TEMPERATURE RATING OF RATURE RATING. EXTRA HEAT RESISTANT. GO'C/1H0°F = 120 AMPERES NOT MOISTURE RESISTANT . NYLON JACKET b. NO.8 AWG COPPER CONDUCTOR WITH THHN OVER INSULATION . NOT SUNLIGHT RESSTANT. INOULATION AND A TEMPERATURE RATING OF bTHWN : THERMOPLASTIC..169°7 TEMPERATURE 78°C /167°F =[50 AMPERES | RATING. MOISTURE AND HEAT RESISTANT. §. A SET OF COPPER CONDUCTORS ON A BRANCH NYLON JACKET OVER INGULATION NOT CIRCUIT SERVE A TANK PUMP MOTOR RATED AT SUNUGHT RESISTANT . 20 A. THE PUMP Ip SO FT FROM A 230 V PowsR, C-AHHW + THERMOSET . 14°F TEMPERATURE SOURCE COMPARE THE LINE LOSbES OF NO: 4 GR 2521/1009 1) ANG GOFFER CONDUCTORS NO. 12 (R= RATING . EXTRA HEAT RESISTANT. WET “Yep. /1000 1) Awe COPPER CONDUCTORS , NO. 10 (R= AND DRY RATING- 4.02 2/1000 fF) AWG COPPER CONQUCTOR® . AL : TW, UF AT 14O°F TEMPERATURE RATIG, > TOTAL CONDUCTOR LENGTH = 50 ft +2 * Too ft RH, RHW , THHW, THW , THWN , XHHW, USE *POWER CONSUMED © THE PumP < EI « 230V-20A NT iG#°F TEMPERATURE RATING ; TA,TBS, »POWER CONSUMED OY THE PUMP = 4c00 W 2A, OD, RAH, RHW-2, THEN , THW-2, TAWA, »PERCENTAGE OF POWER LOSS [5 + eee By a AT" NO.14 = (20A)*-(2.15.0/rc01)* toot « GM xtoo mF TEMPERATURE RATING tone f . CU: TW, UF AT 1HO"F TEMPERATURE RATING; Vo. 49 « eae: a on Sie FEPW, RH, RHW , THHW , THW , XHHW., USE: A E ae 5100 4] 2W AT 1G4°7 TEMPERATURE RATING '; "©: ANO.12 AWG COPPER CONDUCTOR WITH A TWO" TA, TBD, SA OID, FEP, FEPE, MI, RAH WAY LENGTH OF 200 IT IS CARRYING A LOAD OF RHW-2 THIN THAW. MI, RAH, 20. A ON A 230 V, TWO-WIRE CIRCUIT. APPRO- 2 ,THHN THAW, THW-2 ,THWN-2, — ximMATE THE VOLTAGE DROP IN THE CONDUCTOR, USE-2, XHH XHHW ,XHHW-2 ,2W-2 THE PERCENTAGE Of VOLTAGE DROP, AND THE LINE VOLTAGE. AT 194° TEMPERATURE RATING. G: "ap (IR * 20+ (Heese) “200 ft + [E48 V_] DWI RESPECT TO CONDUCTOR —"FERCENHGE OF Earp * “Gaey— 100 *[2.679 %_] INSULATION , DESCRIBE THE FF. +LINE VOLTAGE + 220 V- 6.48 V *

You might also like