Protocol on Current Turbine Performance and Upgrade / Derate Requisition

(Condensing Turbines) CCC/13-14/041A R0


Customer Name: MANCHUKONDA AGROTECH PVT LTD Contract Number : 9663957567
Turbine Frame & Sl. No.: TST-2030-075 Driven Equipment : Steam Turbine
Inlet Pipeline Size : ID=146.3mm, OD: 168.3mm (6Inc) Exhaust Pipeline Size : 1200 x 380 (Inside) Pipeline (4Inc)
Bleed Pipeline Size : NA Extraction Pipeline Size : 14Inc ( ID 339.75mm)

Desired
Initially designed Initially designed Present / Running Present Running (Off- Desired Parameters
Factors ¯ (Season) (Off-Season) (Season) Season) (Season)
Parameters (Off-
Inlet Pressure (Kg/cm²g) : 64Ata 64Ata 64 to 66 64Ata 64Ata Season)
64Ata
Inlet Temperature ( °C) 490 °C 490 °C 470 to 490 490 °C 490 °C 490 °C
Inlet Flow (TPH) : 29 16.85 26 to 27 14 to 16 27 13
Bleed 1 Pressure (Kg/cm²g) : NA NA NA NA NA NA
Bleed Flow 1 (TPH) NA NA NA NA NA NA
Bleed 2 Pressure (Kg/cm²g) : NA NA NA NA NA NA
Bleed Flow 2 (TPH) NA NA NA NA NA NA
Extraction Pressure (Kg/cm²g) : 3.0Ata 3.0Ata 2.1 to 2.5 2.2 to 2.4 3.5Ata
Extraction Flow (TPH) : 23.85 1.75 12 to 14 1 to 3 16.73 0
Exhaust Pressure (ata) : 0.08 0.112 0.09 to 0.11 0.09 to 0.11 0.1Ata 0.1Ata
Exhaust Flow (TPH) : 5.064 15 10 to 13 12 to 15 10.3
Driven Equipment Steam Turbine Steam Turbine Steam Turbine Steam Turbine Steam Turbine Steam Turbine
Power (KW / BHP): 4750KW 3700KW 5000KW 3300KW 5000KW 2400KW
Speed Ratio (Input / Output) : 8278/1500 8278/1500 8278/1500 8278/1500 8278/1500 8278/1500

Gearbox details * : Alternator Details : Condenser Details :


Gearbox serial no. : 0500x0000124HSGH Alternator Make : BHEL Condenser Make : MAZDA LIMITED
Pinion ID mark : Alternator Sl. No. : 44011A261.11.01 Condenser Capacity : 15TPH
Gearwheel ID mark : Alternator Frame : G64862 Condenser Type : Surface, Shell and Tube
Alternator capacity : 6250KVA
Remarks :
1. In case of upgradation of 3 MW or below turbines, the face width of gear and pinion is a must.
2. For Clarity, please attach the data sheet and Performance curve from the turbine manual.