GM300 - Specifications
Process Overview The air filtration system is designed to treat wastewater
odour emissions entering the unit by the two McBerns
Proprietary Combined Media Cartridges, which is emitted to
atmosphere.

Filtration Properties H 2S Treatment Capacity 1.72 kg


Total Media Volume 0.015m3

Media Mass

McBerns Combined Media (Cartridges) 1 x F300MC


Total Media Mass 11 kg

Flow Properties Design Flow Rate 15 L/s


Fan Flow Properties

Storm 10 (4 Pole) N/A


Differential Pressure (refer to figure at back) 42Pa
Unit Properties Dimensions

Unit Housing 415 x 406 mm

Inlet Duct DN100 UPVC


Material Properties

Fabrication Material UPVC


Specific Gravity 1.42g/cm3
Max Continuous Operating Temperature 50°C
Max Short Term Operating Temperature 60°C
Tensile Strength 51MPa
Brinell Hardness 15kg/mm2
Mass

Unit Housing 13kg


Overall (Including Media) 24kg

Responsibility: Cathi Southern Identification Number: 793


Version: 1 Version Date: 12/02/2020
11 Tectonic Crescent Kunda Park Qld Australia 4556
Ph: 61 7 5445 1646 I Fax: 61 7 5445 1743
2
mail@mcberns.com I www.mcberns.com

GM300 Diff. Pressure vs Flow Rate


250

200

y = 47462x2 + 2259.5x - 2.6694


Differential Pressure (Pa)

150

100

x = 0.015
y = 42
50

0
0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05
Flow Rate (m3/s)

Responsibility: Cathi Southern Identification Number: 793