You are on page 1of 2

Data Sheet

Copper State Rubber Project

6"
Design pressure 226.5 barg 3285.5 psig
Design temperature 121.0 °C 249.8 °F
Operating pressure 143.8 barg 2085.5 psig
Inner Diameter
Operating temperature 65.0 °C 149.0 °F

152.4 mm Design water depth 43 m 140 ft


Design life 10.0 years
Water Injection Jumper
MBR storage/service 1.72 m / 2.58 m
U-value wet annulus 12.6 W/(m²K)
Application DYNAMIC

Service SOUR Empty Liquid Testwater

Outer Diameter 221.2 mm / 8.7" Fluid density (kg/m³) 1000.0 1000.0


Weight in air (kg/m) 63.2 82.7 82.7
Status DRAFT
Weight in sea (kg/m) 23.8 43.2 43.2
NOV ref. 9341-PID-404 rev. 0
Dia. to apparent weight (m²/Te) 9.3 5.1 5.1

Code Structural Layer Material


CC Carcass Duplex 2101
IL Inner Liner PVDF
PA Pressure Armour Sour service steel armour
TA Tensile Armour Sour service steel armour
OS Outer Sheath PA11
Pipeflex 5.3.31 | Des.ref.: nTv8U NIwPs CcpSZ rUNe6 | Prepared: DAH [23-Sep-2015] | Checked: | Approved:

This document contains confidential information. All rights (including copyright, confidential information, trade secrets, and design rights) are
owned by National Oilwell Varco Denmark I/S.
No use or disclosure is to be made without the prior written permission of National Oilwell Varco Denmark I/S. All rights reserved.

1/2
Data Sheet

Copper State Rubber Project

Installation Limitations
Bending stiffness @ 20 °C (polymer layers only) 38 kNm²

Bending stiffness at operating temperature (in sea) 23 kNm²

Bending stiffness at design temperature (in sea) 14 kNm²

Axial tensile stiffness @ 20 °C (tensile armour and polymer layers) 318 MN

Torsional stiffness (tensile armour only) 12 kNm²/deg


Max load per track Max load per length catenary Required length at estimated
Track type Angle
(q) (F) installation tension (L)
2P 64 kN/m 12.9 kN/m 4.28 m

3P 125 kN/m 37.6 kN/m 1.46 m

4P 173 kN/m 69.3 kN/m 0.79 m

2V 140° 71 kN/m 15.2 kN/m 3.63 m

3V 140° 342 kN/m 109.2 kN/m 0.50 m

4V 140° 647 kN/m 275.3 kN/m 0.20 m

Chute (single curvature)

Crushing controlled chute radius at estimated installation tension 0.86 m

MBR controlled chute radius (MBR structural x 1.25 - ½ D) 2.04 m

Resulting minimum chute radius 2.04 m

Allowed Tension at Chute Radius Track type 2P - max load per track (q), max load per length catenary (F) and
required length at estimated installation tension (L)

Internal friction factor 0.15

Safety factor 1.50

Estimated installation tension 55 kN

Density of testwater (in bore) 1000.0 kg/m³