Application Example Simoton It Democase v1 1 en
Application Example Simoton It Democase v1 1 en
Demo
SIMOTION IT
If you have any questions concerning this document please e-mail us to the
following address:
online-support.automation@siemens.com
Siemens AG Copyright 2011 All rights reserved
Copyright
SIMOTON IT DIAG
Demo case
Siemens AG Copyright 2011 All rights reserved
Copyright
foreseeable damage, typical for the type of contract, except in the event of
intent or gross negligence or injury to life, body or health. The above
provisions do not imply a change of the burden of proof to your detriment.
Table of Contents
Warranty and Liability ................................................................................................ 4
1 Automation Task....................................................................................... 6
1.1 Overview......................................................................................................... 6
2 Automation Solution ................................................................................ 7
2.1 Overview......................................................................................................... 7
2.2 Required Hardware and Software Components .............................................. 8
3 Start-up of the application ....................................................................... 9
3.1 Preparation ..................................................................................................... 9
3.2 Startup ............................................................................................................ 9
4 Operation of the Application.................................................................. 11
4.1 Overview....................................................................................................... 11
4.2 Controller D435 “Plotter“ ............................................................................... 12
4.2.1 User-defined page......................................................................................... 12
4.2.2 Standard pages............................................................................................. 14
Siemens AG Copyright 2011 All rights reserved
1 Automation Task
1.1 Overview
Introduction
SIMOTION IT DIAG offers the capability to commission a SIMOTION
project without the need of the engineering system SCOUT. Integrated into
the SIMOTION Controller is a web server that can be accessed with a
standard web browser (e.g. Microsoft Internet Explorer V6.0 and later).
browser
(e.g. Internet
Explorer)
HTTP Response
Copyright
2 Automation Solution
2.1 Overview
Display
The following figure displays the most important components of the
solution:
Figure 2-1
Siemens AG Copyright 2011 All rights reserved
PC
Delimitation
This application does not include a description of
HTML
SIMOTION IT OPC XML-DA
SIMOTION IT DIAG
Basic knowledge of these topics is assumed.
Required knowledge
Basic knowledge of SIMOTION IT Ethernet-based HMI- and diagnostic
functions is assumed.
Hardware components
Table 2-1
Component No. MLFB / order number Note
SIMOTION training unit 1 6ZB2470-0AE00 SIMOTION D435 +
DMM
SIMOTION D410 PN 1 6AU1410-0AB00-0AA0 2x PN ports
example.
Table 2-3
Component Note
SIMOTION_IT_Democase_V1_1.zip
Applikationsbeispiel_SIMOTION_IT_Demokoffer_V1_1_de.p
df
Application_Example_SIMOTION_IT_Democase_V1_1_en.
pdf
of 2 Hz. After this, cycle power. between the D435 (X100) and
the double motor module
(X200) must be plugged in.
3.2 Startup
Table 3-2: Commissioning of the plotter sample application for the SIMOTION training unit
Copyright
Table 3-3: Commissioning of the AchsFB sample application for the SIMOTION D410 PN
No. Instruction Remarks
1 Set the IP address of the D410 PN PROFINET The default IP address of the
interface (X200 / X201) to 192.168.214.2 using HW- PROFINET interface (X200 /
Config or the Primary Setup Tool (see note). The X201) is 0.0.0.0.
subnet mask must be 255.255.255.0.
2 Open a web browser.
3 Type in the address http://192.168.214.2 to connect
to the SIMOTION D410 PN (X200 / X201).
4 In the standard web page “Settings” you must switch
the controller to STOP mode.
5 In the standard web page “Manage Config” you then This update does not change
send the file “IT- the IP address of the
Democase_V1_1\Device_Update_Tool_Data\OPL_S SIMOTION controller.
WIVEL.ZIP” to the SIMOTION controller.
6 After the transfer is complete, switch the controller
back to RUN mode.
Siemens AG Copyright 2011 All rights reserved
Note The Primary Setup Tool can be downloaded from following link.
http://support.automation.siemens.com/WW/view/de/14929629
Copyright
When the commissioning of chapter 3 is complete, the web server for each
SIMOTION controller is accessible via web browser using the following
addresses.
The description of the standard web pages can be found in the system
documentation “SIMOTION_IT_DIAG.pdf“.
The user defined pages in the “User’s Area” are described below.
Siemens AG Copyright 2011 All rights reserved
4.1 Overview
PLANT
Figure 4-1: User-specific site PLANT
Copyright
These user defined pages reside on both controllers and can be accessed
from their IP addresses. They show an overview of the controllers.
Available “plotter” data is: the CPU state, the count of active alarms, the
program state and the motor temperature.
The links “Home”, “Alarms” and “Diagnostics buffer” open the related
standard web pages of the SIMOTION D435.
CONTROL
Figure 4-2: User-defined page “CONTROL”
Siemens AG Copyright 2011 All rights reserved
Copyright
The user defined page “CONTROL” offers the capability to change the
length and speed of the movement. The picture “Profil_01.PNG” defines
each value.
With the START and STOP buttons, the movement of both axes is
controlled. The user defined page “STATE” shows the current process
values.
The button “Simulate drive error” is doing just that. A drive error is triggered
which stops both axes. Additionaly the standard web page
“Messages&Logs” will show the drive’s error details. Here you can
acknowledge any error message with the “quit” button.
STATE
Figure 4-3: User-defined page “STATE”
Siemens AG Copyright 2011 All rights reserved
Copyright
The user defined page “STATE“ is showing the current state of the plotter
axes using, OPC XML-DA Subscription, to update the values. Detailed
information can be found here:
Source code
“SIMOTION_IT_DIAG.pdf” chapter 3.5.6
Diagnostics – Watch
Figure 4-4: Standard page: Diagnostics - Watch
Siemens AG Copyright 2011 All rights reserved
Copyright
Diagnostics – Trace
In the page “Diagnostics – Watch“, the trace configuration
“IT-Democase_V1_1\Watch_Trace_Config\Plotter_wtrace.xml“ can be sent
to the “Plotter” SIMOTION controller. With the imported configuration,
values for the position and speed of the X and Z axes are displayed.
AxisFB
Figure 4-5: User-defined page: “AxisFB”