You are on page 1of 18

CHEMICAL

RESISTANCE
CHARTS FOR
HOSE

ALWAYS BE ON GUARD
CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane

316 Stainless
Teflon (PTFE)
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Aluminum G G G G G G G G X G G G G G G G G X G X X F
Chloride
Aluminum G G G G G F G G X G G G — G X G G X G X X X
Fluoride
Aluminum G G G G G G G G G G G G — G G G G G G X F G
Hydroxide
Aluminum G G G G G G G G F G G G — X — G G G G X X G
Nitrate
Aluminum G G G G G G G G F G G G G G G G G G G X X G
Sulfate
Alums G G G G G G G G G G G G X G G G G F G X X F
Ammonia, — — — — — — — — — — — — — — — — — — — X F G
Anhydrous
Ammonia G G G G G F G G X G G F X X X — G G — X G G
Solution
(10%)
Ammonium G G G G G G G G X G G G G F G G G X G X G F
Chloride
Ammonium G G X F F F G G X G G F X X G G G G F X F G
Hydroxide
Ammonium G G G G G G G G G G G G G X G G G G G — — G
Nitrate
Ammonium G G F G G G G G G G G G G F G G G G G X X G
Phosphate
Ammonium G G G G G G G G G G G G G G G G G G G X X F
Sulfate
Amyl Acetate G G X X X X G G G F X X F X X X X G X G F G
Amyl Alcohol G G X G G F G G G G G G G X G G G G X G F F
Aniline G G X X X X G G X X X X X X X X X X X X G G
Aniline Dyes G G X F F F G G X G F F X X X X X X X X X F
Animal Oils G G G G G X G G — F F X G X F X X G X G G G
and Fats
Anti—Freeze G G G G G G G G — G G G G X G G F G G G G G
(Glycol Base)
Aqua Regia X X X X X X G F X X X X X X X X X X F — X X
Aromatic G* G* X X X X G G G X X X X X X — G* G — G G G
Hydrocarbons
Asphalt X X X G X X G G — X X X G X F X — G F G G G
Emulsion
Barium G G G G G G G G — G G G G G G G G G G X F G
Chloride
Barium G G G G G G G G G G G G G X G G G G G X G G
Hydroxide
Barium G G G G G G G G G G G G X G X G G G G G G G
Sulfate
Barium G G G G G G G G — G G G X G G G G X G X X G
Sulfide
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications

2 Chemical Resistance Chart Content Provided courtesy of EATON


CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Beet Sugar G G G G G G G G G X G G — X G G G G — X G G
Liquors
Benzaldehyde G G X X X X G G G F X X X X X X X G X F F G
Benzene, G* G* X X X X G G G X X X X X F X X G F G G G
Benzol
Benzoic Acid G G X X X G G G X X X X X X G G G X G F X F
Black Sulfate G F X F F G G G X G F X G X X G G X G X G G
Liquor
Bleach F F F X X X G G X G F X F F G G* G X G X X G
Solution
Borax G G G F F G G G — G G G G G G G G G G G G G
Solution
Boric Acid G G G G G G G G G G G G G G X G G G G X X G
Brake Fluid G G X X X F G G — G X X — X G — X G X G G G
(Glycol Ether
Base)
Brine G G G G G G G G — G G G G X G G G G G — X F
Bromine X X X X X X G X X X X X X X X X X X X X X X
Butyl Acetate G G X X X X G G — F X X F X F — X G X G G G
Butyl Alcohol, G G X G G G G G G G G G G X G G G G F G G G
Butanol
Calcium G G G G G G G G X G G G X G X G G G G X X X
Bisulfite
Calcium G G G G G G G G X G G G G G G G G G G X F F
Chloride
Calcium G G G F F G G G G G F G G X G G G G G F G G
Hydroxide
Calcium G G G F F F G G X G F X F X G G G X G F X F
Hypochlorite
Cane Sugar G G G G G G G G — G G G G X G G G G — F G G
Liquors
Carbon G G G G G G G G G G G F G G G G G G G G G G
Dioxide (Dry)
Carbon G G G G G G G G G G G F — G — G G G G F G G
Dioxide (Wet)
Carbon Disul- F X X X X X G G X X X X X G X — X X — G G G
fide (Bisulfide)
Carbon — — X F F F G G X F G X G F G G X X G X F G
Monoxide (Hot)
Carbon G* G* X X X X G G G X X X F X X — X G X G G G
Tetrachloride
Carbonic Acid G G G G G G G G — G G G X G X G G G G X X F
Castor Oil G G G G G F G G — F G X F F G X X G G G G G
Cellosolve G G X X X X G G — F F X X X X X — G G X X G
Acetate
Chlorinated G* G* X X X X G G G X X X X X X — X F X G G F
Solvents
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications
Chemical Resistance Chart Content Provided courtesy of EATON 3
CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass

Steel
XLPE

PVC

EVA
CPE
Chloroacetic G G X X X X G G X F X X X X X X X X F X X F
Acid
Chloro- G* G* X X X X G G X X X X X X — X X X X F F G
benzene
Chlorine X X X X X X G X X X X X X X X X X X G F F G
Gas (Dry)
Chlorine X X X X X X G X X X X X X X X X X X F X X X
Gas (Wet)
Chloroform G* G* X X X X G G G X X X X X X X X F U G G G
Chlorosul- F* F* X X X X G G X X X X X X X X X X X X F X
fonic Acid
Chromic Acid G X F X X X G G X G G X X X X G F X G X X G
(under 25%
Chromic Acid G X X X X X G G X G G X X X X F X X F X X F
(25-40%)
Citric Acid G G G F F G G G F G G G G X X G G X G X X G
Coke Oven X X X X X X G G — X X X — X X — G — G F G G
Gas
Copper G G G G G F G G X G G G G G X G G X G X X G
Chloride
Copper G G G G G F G G G G G G — G — G G G G X X G
Cyanide
Copper G G G G G G G G G G G G G G G G G G G X X G
Sulfate
Corn Syrup G G G G G F G G — G F F G G — G G G G — G G
(Non-food)
Cottonseed G G F G G X G G — F F X G G G G G G G G G G
Oil
Creosote G G X F F X G G X X F X X F F X X X X F — G
Cresol G G X X X X G G X X X X X X G X X X — — G G
Cyclohexanol G G X F F F G G G G G F — — G G F G X G F G
Dextrose G X X X X X G G X X X X X X X G G X — — — G
(Food Grade)
Dichloro- G* G* X X X X G G — X X X X X X X X G X — — G
benzene
Diesel Fuel G G X G G X G G — X F X F F G — X G — G G G
Diethanol- G G X F X X G G — G X F X X — — — G — X G G
amine
Diethylene- G G X F X X G G X G X F — X — — G X — — — —
triamine
Dowtherm A — — X X X X G G X X X X X — X X X X X X F G
Enamel G G X F F X G G — X X X G — G — G G — G — G
(Solvent Base)
Ethanolamine G G X F F X G G — G X G — X — — G G — X G G
Ethers G G X X X X G G — X X X X X G X X G X G G G
(Ethyl Ether)
Ethyl Alcohol G G F G G G G G G G G G G G G F G G G F G G
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications
4 Chemical Resistance Chart Content Provided courtesy of EATON
CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends

316 Stainless
Polyurethane
Teflon (PTFE)
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Ethyl Acetate G G X X X X G G G G X X F X F F G G X G G G
Ethyl Acrylate G G X X X X G G — F X X — X F — — X X — G G
Ethyl G G X X X X G G — F X X — X F — — X — — G G
Methacrylate
Ethylamine G G X X X X G G X F X X — X — — G X — G — G
Ethyl G G X F F F G G — F F G — F G — G F — F G F
Cellulose
Ethyl Chloride G* G* X X X X G G — X X X X F X X X G X F F G
Ethylene- G G X F X G G G X G F G — X — — G X — G G G
diamine
Ethylene G G X X X X G G — X X X — X — — — F — — — —
Dibromide
Ethylene G* G* X X X X G G — X X X X X X X X F X G X X
Dichloride
Ethylene G G G G G G G G G G G G G F G G G G G F G G
Glycol
Ethylene G G X X X X G G — X X X G X X X X G X X F F
Oxide
Fatty Acids G G G F F X G G G F X X G — F F G G G F F G
Ferric G G G G G G G G G G G G — F G G G G G X X X
Chloride 5%
Ferric Sulfate G G G G G G G G G G G G G — G G G G G X X F
Fertilizer G G G F F F G G — G G G — — — — F G — — — G
Salts Solution
Formaldehyde G G X F F F G G G G X F F X G G G X G F X G
Formic Acid G G X F F F G G X G X X X X G G G X — F X G
Freon 12** — — — — — — G — — — — — — — — — — — — G G G
Freon 134a** — — — — — — G — — — — — — — — — — — — — G G
Fuel Oil G G F G G F G G — X X X — F G X X G G F G G
Furfural G G X X X X G G X F F X — — F X X X X F G G
Gasoline G G X F F X G G G X X X G F G — X G X G G G
(Refined)
Gasoline G G X G G X G G G X F X X X G — X G F G G G
(Unleaded)
Gasoline G G X G G X G G G X X X X X — — X G F G G G
(10% Ethanol)
Gasoline G G X F F X G G G X X X X X — — X G F G G G
(10% Methanol)
Glucose G G G G G G G G G G G G G G G G G G G G G G
(Non-food)
Glycerine, G G G G G G G G G G G G G X G G G G G G G G
Glycerol (Non-food)
Greases G G G G G F G G G X F X G G G — G G G G G G
Green G G G F F F G G X G G G X G X G G X F X X G
Sulfate Liquor
Heptane G G X G G F G G G X F X G F G X X G G G G G
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications
Chemical Resistance Chart Content Provided courtesy of EATON 5
CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends

316 Stainless
Polyurethane
Teflon (PTFE)
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Hexane G G X G G F G G G X F X G F G X X G X G G G
Houghto Safe G G F G G G G G — G — F — X G — G G — G G G
273 to 640
Houghto Safe G G G G G G G G — X X X G X G — G G — G G G
5046, 5047F
Houghto Safe G G X X X X G G — G X X — X — — X G — G G G
1000 Series
Hydraulic Oils:
Straight G G G G G F G G G X F X G G G F G G G G G G
Petroleum Base
Water Petro- G G — G G F G G — X F X G X G — F G — G G G
leum Emulsion
Water Glycol G G X G G G G G G G X F X X G — — G — G G G
Hydraulic Oils:
Straight G G X X X X G G G G X X — X G — X G — G G G
Phosphate Ester
Phos. Ester/ G G X X X X G G G X X X — X G — X G — G G G
Petroleum Blend
Polyol Ester G G — G G X G G — X — X — G G — — G — G G G
Hydrobromic G G G X X X G G X G G X X X G G G X G X X X
Acid (under 48%)
Hydrochloric G G G X X X G G X G G X X X G G G X G X X X
Acid
Hydrocyanic G G G F F X G G X F G X X — X G G X F X F G
Acid
Hydrofluoric G G F X X X G G X F G X X X X G F X G X X G
Acid (under 50%)
Hydrofluoric G G X X X X G G X X G X X X X G X X G X X G
Acid (over 50%)
Hydrofluo- G G G F F X G G X G G X — — G — G X — X X X
silicic Acid
Hydrogen — — — — — — — — — — — — — — — F — — F — — G
Hydrogen F F — X X X G G X F X X — — G X G X F X X G
Peroxide
Hydrogen G G G X X X G G X X F X G — X G G X G F F F
Sulfide
Hydrolube G G G G G F G G — G — — F X — — G G — G G G
Iodine F F X F X X G G X G G X — X G X X X X X X X
Isocyanates G X X X X X G — X X X X X X X — X X — — — —
Isopropyl G G G G G G G G G G G G G X G — G G G G G G
Alcohol, Isopropanol
Isopropyl- G G X X X F G G — F X F — — — — — X — G — G
amine
Iso-Octane G G X G G F G G G X F X G X G — X G X G G G
Jet Fuel G G X G G F G G G X X X G F G — X G X G F G
(Transfer Only)

G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications
6 Chemical Resistance Chart Content Provided courtesy of EATON
CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Kerosene G G X G G F G G G X F X F G G X X G X G G G
Lacquer G G X X X X G G G X X X X X F X F G X G X G
Lacquer G G X X X X G G G X X X F X F X F G X G X G
Solvents
Lactic Acid G G G X X G G G G F G X X X X G G G G F F G
Lime Sulfur G G G X X G G G F G F F — — — G G G G X — G
Lindol G G — X X X G G G G X X — X — — — G X F G G
Linseed Oil G G G G G X G G G X F X F F G X G G G F G G
Lubricating G G G G G F G G G X F X G F G X G G G G G G
Oils
Lye G G G F F G G G F G G G — X F — G G — F X G
Magnesium G G G G G G G G G G G G — G G G G G G F F G
Chloride
Magnesium G G G F F G G G G G F G — X G G G G G G G G
Hydroxide
Magnesium G G G G G G G G G G G G — — G G G G G F G G
Sulfate
Mercuric G G F F F G G G X G G F — — X G G X G X X X
Chloride
Mercury G G F G G G G G G G G F G G G G G G G X G G
Methyl Alc., G G X G G G G G G G G G G F G G G G X F G G
Methanol
Methyl G G X X X X G G X F X X — X X — — X — G G G
Acrylate
Methyl X X X X X X G G F X X X X X X X X G X G G G
Bromide
Methyl G* G* X X X X G G G X X X X X F X X G X G G G
Chloride
Methylene G* G* X X X X G G F X X X X X X X X F X G G G
Chloride
Methyl-t-Butyl G G X F F X G G G X X X — — G — — G — — G G
Ether (MTBE)
Methyl Ethyl G G X X X X G G G F X X G X X X G G X G G G
Ketone
Methyl Iso- G G X X X X G G G F X X — X X X G G X G G G
butyl Ketone
Methyl Iso- G G X X X X G G G F X X — X X — G G X G G G
propyl Ketone
Methyl G G X X X X G G — X X X — X X — — G — — G G
Methacrylate
Mineral Oil G G F G G F G G G X F X G G G X X G G G G G
Mineral G G X G G F G G G X X X G F G — G G — G G G
Spirits
Naphtha G G X F F F G G G X X X G F G X G G X F G G
Napthalene G G X X X X G G G X X X F F G X X G X F G G

G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications

Chemical Resistance Chart Content Provided courtesy of EATON 7


CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
XLPE

Steel
PVC

EVA
CPE
Nickel G G G X X G G G G G G G — X — G G G G G G G
Acetate
Nickel G G G G G F G G G G G G X X G G G G G X X F
Chloride
Nickel Sulfate G G G G G F G G G G G G — F G G G G G X X G
Nitric Acid G F* G X X X G G X F F X X X X G F* X G X X G
(under 35%)
Nitric Acid F X F X X X G G X X X X X X X X X X G X X G
(35% to 60%)
Nitric Acid X X X X X X G G X X X X X X X X X X G X X G
(over 60%)
Nitrobenzene G G X X X X G G — X X X X X X X X X X F G G
Nitrogen G G G G G G G G G G G G — G G — G G — G G G
Gas
Nitrous Oxide G G X X X X G G F X X G X X X — X F G G G G
Oleic Acid G G F F F X G G G F F X G F G X G G G F F G
Oleum X X X X X X G G X X X X X X X X X X X X F G
(Fuming
Sulfuric Acid)
Oxalic Acid G G G X X X G G X G X X X — G G G X G F X G
Oxygen G G G F F G G G G G G F G G G G G G G G G G
(non-breathing,
non-welding)
Ozone F F X X X X G G X G G X X G G X X X X — F G
(300 pphm)
Paint G G X F F X G G G X X X — X — — F G — G G G
(Solvent Base)
Palmitic Acid G G F F F F G G G F X X G X G F G G F X F F
Paper Mill G G X F F F G G X G F F X X — — X X — — — —
Liquors
Pentane G G X G G F G G — X F X G X G — X G X G G G
Perchloro- G* G* X X X X G G G X X X X X X — F X F F G G
ethylene
Petroleum G G X G F X G G G X X X — G G X X G F G G G
Ether
Petroleum G G G G G F G G G X F X G G G — G G — G G G
Oils
Phenol G G X X X X G G X X X X X — G X X X X F X F
Phosphoric G G G X X F G G X G G F X X X G G X G X X F
Acid (to 85%)
Picric Acid X X X X X X G G X X F X X X X G X X X X X F
(Molten)
Picric Acid G G X F F X G G X F G X X F X G X X X X X F
(Solution)
Potassium G G G G G G G G G G G G — G G G G G G F X G
Chloride
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
Use Pinpricked hose for gas applications

8 Chemical Resistance Chart Content Provided courtesy of EATON


CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
XLPE

Steel
PVC

EVA
CPE
Potassium G G G G G G G G G G G G G G G F G G F X G G
Cyanide
Potassium G G G X X X G G — G X X — G G G G F G X G G
Dichromate
Potassium G G G F F F G G F G G G F X G G G G G F X G
Hydroxide
Potassium G G G X X X G G X G G G X X — X G X G — — —
Permanganate
Potassium G G G G G G G G G G G G — G G G G G G F F G
Sulfate
Propane — — — G — — — G — — — — — — — X — — — G G G
Liquid***
Propylene G G F G F G G G — G G G G — G G G G — F G G
Glycol
Pyridine G G X X X X G G X F X X X X X — G X — F G G
Sea Water G G G G G G G G G G G G G X G G G G G G F G
Silver Nitrate G G G G G G G G G G G G — G — G G G G X X F
Skydrol G G X X X X G G G G X X — X G — X G — G G G
Soap Solution G G G G G F G G G G G X G G G G X G G G G G
Sodium G G G G G G G G G G G G G G G G G G G F F G
Bicarbonate
Sodium G G G G G G G G G G G G X G G G G G G F F F
Bisulfate
Sodium G G G G G G G G G G G G G G G G G G G F X G
Bisulfite
Sodium G G G G G G G G G G G G G G — — G G — G G G
Borate
Sodium G G G G G G G G G G G G G G G G G G G X G G
Carbonate
Sodium G G G G G G G G G G G G G G G G G G G X F G
Chloride
Sodium G G G G G G G G G G G G G G G G G G G X F G
Cyanide
Sodium G G G F F G G G F G G G — X F G G G F F X G
Hydroxide
Sodium G G G X X X G G X G G X G X F G G X G X X F
Hypochlorite
Sodium G G G G G F G G G G G G G F G G G G G F G G
Nitrate
Sodium G G G G G X G G F G X G G X X — G G — F F G
Perborate
Sodium G G X F F F G G X G F X G X X — X G — X F G
Peroxide
Sodium G G G G G F G G G G G G G G X G G G G F F F
Phosphates
Sodium G G G G G G G G G G G G G G G G G G G F F G
Silicate
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications

Chemical Resistance Chart Content Provided courtesy of EATON 9


CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends
Polyurethane
Teflon (PTFE)

316 Stainless
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Sodium G G G G G G G G G G G G G G G G G G G F F G
Sulfate
Sodium G G G G G G G G G G G G G G G G G G G X X G
Sulfide
Sodium G G G G G G G G G G G G — G G G G G G X X G
Thiosulfate
Soybean G G F G G F G G — F G X G G G — G G — G G G
Oil
Stannic G G G G G X G G X G G G G G G G G F G X X X
Chloride
Steam 450°F X X X X X X G G X G X X X X X — X X — F F G
Stearic Acid G G F F F F G G G F F X G G G G G G F X X G
Stoddard G G X G G F G G G X X X G G G X X G G G G G
Solvent
Styrene G* G* X X X X G G G X X X X X X — X G X G G G
Sulfur 70°F G G F X X G G G G G G X G F G G G G G X X G
Sulfur 200°F X X X X X X G G X X G X X X X — X X — X X G
Sulfur G G X X X X G G X X F X X X G — G X — X X X
Chloride
Sulfur Dioxide X X X X X X G G X G X X X X X X X X F X — G
Sulfuric Acid G G G X X X G G X G G X X X X G G X G X X X
(under 50%)
Sulfuric Acid G G G X X X G G X F G X X X X X X X F X X X
(51% to 70%)
Sulfuric Acid G F X X X X G G X F F X X X X X X X G X X X
(71% to 95%)
Sulfuric Acid G X X X X X G G X X X X X X X X X X X X X X
(96% to 98%)
Tannic Acid G G G F F F G G X G G G G G G G G X G F X G
Tar X X X F F F G G G X X X G F F — X X — F F G
Tartaric Acid G G G G G F G G G G G G — G G G G G G F X F
Tetrachloro- G* G* X X X X G G — X X X X X X — F F X — — G
ethane
Tetrahydro- G G X X X X G G — X X X — X — X X G X — — G
furan (THF)
Toluene G* G* X X X X G G G X X X X X X X G* G X G G G
Transmission G G G G G F G G G X F X G G G X G G — G G G
Oil (Petrol. Base)
Trichloro- G* G* X X X X G G G X X X X X X — G* F — G G G
ethane
Trichloro- G* G* X X X X G G G X X X X X X X G* F — G G G
ethylene
Tung Oil G G — G G F G G — X F X G F X — — G — F G G
Turpentine G G X F F X G G G X X X F X F X G G G F G G
Urea (Water G G G X X G G G G G G G G G G G G G G — G G
Solution)
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications

10 Chemical Resistance Chart Content Provided courtesy of EATON


CHEMICAL RESISTANCE
Charts
CHEMICAL RESISTANCE
for Hose

Fluid Hose and Tubing Material Metals

Natural Rubber/SBR

PVC / PU Blends

316 Stainless
Polyurethane
Teflon (PTFE)
Vinyl Nitrile

Teflon (FEP)

Nylon 6/66
Neoprene

Nylon 11
Hypalon
UHMW

Nitrile

LLDPE
EPDM

Hytrel

Brass
Steel
XLPE

PVC

EVA
CPE
Uric Acid G G G — — — G G G — — — X X — G G G G — — F
Varnish G G X X X X G G G X X X — X F X G G X G G G
Vegetable G G F G G X G G G X G X — G — X G G G G G G
Oil (Non-food)
Vinegar G G G F F G G G X G G F — X F G G G — X F G
Vinyl Acetate G G X X X X G G — F X X — X — X — G X F G G
Water G G G G G G G G G G G G G G G G G G G F F G
(non-potable)
Water— G G X G G G G G G G X F X X G G — G G G G G
Glycol Mixture
Water— G G — G G F G G G X F X G X G G F G G G G G
Petroleum Mixture
Xylene G* G* X X X X G G G X X X F X X X G* G X G G G
Zinc Chloride G G G G G G G G X G G G X G X G G X G X X X
Zinc Sulfate G G G G G G G G G G G G — G X G G G G X X G
G - Good F - Fair X - Not Recommended — - Insufficient Information *For Intermittent Transfer Only **Use Approved Freon Hose
***Use Propane Approved Hose Only Use Pinpricked Hose for Gas Applications

Chemical Resistance Chart Content Provided courtesy of EATON 11


EATON INDUSTRIAL HOSE REMINDER
Proper Hose Storage
INDUSTRIAL HOSE REMINDER
Proper Hose Storage

Proper Storage of Hose Product

Proper storage conditions can enhance and extend


substantially the ultimate life of hose product. Rubber hose
products in storage can be affected adversely by
temperature, humidity, ozone, sunlight, oils, solvents,
corrosive liquids and fumes, insects, rodents and radioactive
materials. The appropriate method of storing hose depends
to a great extent on its size (diameter and length), and the
way in which it is packaged. Hose should not be piled or
stacked to such an extent that the weight of the stack
creates distortions on the bottom. Since hose products vary
considerably in size, weight and length, it is not practical to
establish definite recommendations on this point. Hose
having a very light wall will not support as much load as
would a hose having a wire reinforcement. Hose which is
shipped in coils or bales should be stored so that the coils
are in a horizontal plane.

Notes

12 Chemical Resistance Chart Content Provided courtesy of EATON


GENERAL HOSE INFORMATION
Hose Maintenance
GENERAL HOSE INFORMATION
Hose Maintenance

Look for any indication 2. Couplings SAFETY WARNING: 1. Hose shall lie in a straight
of kinking or broken
All metals are subject to Failure to properly and horizontal position
reinforcement as evidenced
attack by various chemicals. follow the manufacturer’s supported on rollers to
by any permanent distortion,
Check with the manufacturer recommended procedures permit easy movement
longitudinal ridges, or bulges.
to make sure that suitable for the care, maintenance when under the test
According to RMA lP-11-7 end fittings, appropriate and storage of a particular pressure.
Chemical Hose Bulletin, to both the hose and the hose might result in its
2. Water should be used
crushed or kinked spots chemical being handled, are failure to perform in the
as the test liquid. Never
where the hose O.D. is being used. manner intended and
pressure test with
reduced by 20 percent or might result in possible
Exposed surfaces of solvents, corrosive liquids,
more of the normal O.D. damage to property and
couplings, flanges and or with compressed
indicate the hose probably serious bodily injury.
nipples shall be examined gases.
has internal damage. The
for cracks or excessive Hydrostatic Pressure Test 3. Fill the hose with water
hose assembly must be
corrosion. Either condition with the outlet end raised
removed from service to For large-bore hose being
shall cause the hose and the outlet valve open
ensure the safety of people used in dock service, an
assembly to be retired from to ensure the complete
in the work area. inspection card which
service. Any evidence of removal of air. When all
WARNING: Kinks can coupling or nipple slippage describes the hose, the air has been expelled,
cause hose to burst, on the hose is cause for manufacturer, date received, close the outlet valve and
leading to bodily harm. removing the hose assembly purchase order number, and lower the raised end.
from service. date of installation should be
Hose containing kinked or maintained for each hose. 4. For new hose, raise the
crushed spots where the The Rubber Manufacturers The inspection card should pressure to 2 times the
hose O.D. is reduced by Association (RMA) has be used to record the test rated working pressure of
20 percent may be used published a series of results and condition of the the hose and hold for 5
if the hose passes the technical bulletins which hose. minutes. During this hold
hydrostatic tests. Use a detail maintenance, period, the hose shall be
caliper to measure the hose testing, and inspection Eaton recommends that examined for leaks at the
outer diameter at several recommendations. new hose assemblies be couplings, fitting slippage,
places around the diameter hydrostatically tested before or for any indication of
Because the life expectancy being placed in service.
to determine any O.D. weakness in the hose
of the hose is limited, Hydrostatic testing should
reduction. An inspection structure.
the user must be alert to be done at periodic intervals
mirror and a flashlight can
signs of impending failure, to determine if a hose 5. For used hose, test
be used to inspect the inner
particularly when the is suitable for continued with a pressure of 1-1/2
tube for abuse, wear, and/or
conditions of service include service. The hydrostatic test times the rated working
chemical attack.
high working pressures and examination shall be pressure of the hose for
and/or the conveyance or conducted in the one minute and examine
containment of hazardous following manner. as above.
materials. The periodic
Hose to be pressure tested 6. Completely relieve test
inspection and testing
must be restrained by pressure from the system
procedures described
placing steel rods or straps prior to releasing hose
here provide a schedule of
close to each end and from test equipment.
specific measures which
constitute a minimum level at approximate 10 foot 7. Thoroughly drain the
of user action to detect signs (3m) intervals along its water from the hose
indicating hose deterioration length to keep the hose after completion of the
or loss of performance from “whipping” if failure hydrostatic test.
before conditions leading occurs; the steel rods or
to malfunction or failure are straps are to be anchored Electrical Continuity
reached. firmly to the test structure
When required by the user,
but in such a manner that
electrical continuity between
they do not contact the
the fittings shall be tested
hose which must be free
using an ohm meter. The
to move.
hose must be clean and dry
for this test.

Chemical Resistance Chart Content Provided courtesy of EATON 13


GENERAL HOSE INFORMATION
Hose Maintenance
GENERAL HOSE INFORMATION
Hose Maintenance

GENERAL CARE AND MAINTENANCE OF HOSE


Hose should not be the hose far enough beyond for storing hose depends • Store items on a first-in,
subjected to any form of the shank to eliminate the to a great extent on its first-out basis. Remember
abuse in service. It should possibility of cutting into the size (diameter and length), that even under the
be handled with reasonable shank. When cutting out the quantity to be stored, best of conditions, an
care. Hose should not be a kink, cut behind the kink and the way in which it is unusually long shelf life will
dragged over sharp or far enough so that the ID/ packaged. Hose should not deteriorate certain rubber
abrasive surfaces unless OD of the remaining hose is be piled or stacked to such products. Inspect and
specifically designed for round. Use calipers to confirm an extent that the weight of test the hose assembly
such service. Care should be roundness. Make sure to cut the stack creates distortions before placing it in service.
taken to protect hose from the hose squarely. Next wipe on the lengths stored at the Usually, any wear or
severe end loads for which the inner tube of the cut end bottom. Since hose products damage will be apparent
the hose or hose assembly with a clean rag. vary considerably in size, during inspection or
was not designed. Hose Before recoupling the hose, weight, and length, it is not testing.
should be used at or below practical to establish definite
make sure to carefully inspect • The ideal temperature
its rated working pressure; the tube. This is important recommendations on this
for the storage of rubber
any changes in pressure because it is easy to see the point. Hose having a very
products ranges from 50°
should be made gradually so condition of the tube and light wall will not support as
to 70°F (10-21°C) with a
as to not subject the hose to reinforcement of the hose much load as would a hose
maximum limit of 100°F
excessive surge pressures. when the coupling is cut having a heavier wall or hose
(38°C). If stored below
Hose should not be kinked off. Look for any evidence having a wire reinforcement.
32°F (0°C), some rubber
or be run over by equipment. of deterioration of the hose Hose which is shipped in
products become stiff and
In handling large size hose, tube. If there are signs of coils or bales should be
will require warming before
dollies should be used deterioration, remove the stored so that the coils are in
being placed in service.
whenever possible; slings hose assembly from service. a horizontal plane.
or handling rigs, properly • Storage areas should be
If after close inspection none
placed, should be used to Storage Do’s: relatively cool and dark,
of these signs is present, the
support heavy hose used and free of dampness and
hose may be recoupled. • Whenever feasible, rubber mildew. Items should be
in oil suction and discharge
Any hose that has been hose products should be stored on a first-in, first-out
service.
used to convey an abrasive stored in their original basis, since even under
material, such as plastic shipping containers which the best of conditions, an
Hose Repair provide some protection
pellets and powders, should unusually long shelf life
There are some not be recoupled due to the against the deteriorating could deteriorate certain
circumstances in which inherent thickness reduction effects of oils, solvents, rubber products.
chemical hoses can be that results from the transfer and corrosive liquids;
repaired. For example, if a of abrasive materials. shipping containers also
Storage Don’ts:
hose has been kinked near afford some protection
the coupling and a close Finally, pressure test and tag against ozone and sunlight. • Don’t pile or stack hose
inspection of the assembly any recoupled assembly as to such an extent that
recommended. • Certain rodents and insects
the weight of the stack
reveals that this is the only will damage rubber hose
damage, the assembly can distorts the lengths stored
Storage products, and adequate
be repaired. on the bottom. Remember
protection from them
Proper storage conditions that hose having a very
should be provided. Be
WARNING Wear can enhance and extend light wall will not support
sure ends are capped to
safety glasses, substantially the ultimate life as much load as a hose
keep out insects, rodents,
gloves, and protective of hose products. Rubber having a heavier wall or
and other contaminants
clothing when cutting hose products in storage wire reinforcement.
that can damage the hose.
hose. They will help can be affected adversely
protect your eyes and skin by temperature, humidity, • Hose shipped in coils or
from flying debris. When ozone, sunlight, oils, bales should be stored so
recoupling a used hose solvents, corrosive liquids the coils are in a horizontal
assembly, begin by cutting and fumes, insects, rodents plane.
and radioactive materials.
The appropriate method

14 Chemical Resistance Chart Content Provided courtesy of EATON


GENERAL HOSE INFORMATION
Hose Maintenance
GENERAL HOSE INFORMATION
Hose Maintenance

• Don’t store rubber ARPM Proper Hose Handling • Never allow chemicals to
products near heat drip on the exterior of a
1400 K Street, N.W. Proper hose handling can
sources such as radiators hose or allow hose to lay
Washington, D.C. 20005 help preserve hose assembly
and base heaters, or in a pool of chemicals.
RMA Publications order life and work environment
near electrical equipment The hose cover may
desk: (800) 325-5095 safety. Therefore, consider
that might generate not have the chemical
the following points when
ozone. Also do not store resistance of the tube. If a
handling hose assemblies.
hose for long periods Proper Used Hose Storage corrosive material comes
in geographical areas Before placing used hose in
• Avoid crushing or kinking into contact with the
of known high ozone the hose. This can cause hose reinforcement, the
storage, completely drain it
concentration. Ozone ages severe damage to the result could be early hose
and flush out any potentially
rubber. reinforcement that isn’t failure.
explosive vapors or corrosive
always obvious when
• Don’t expose hose to residues.
looking at the cover. • Avoid extreme flexing
direct or reflected sunlight Also make sure you dispose of the hose near the
during storage. This ages of waste in a manner that
• Do not drag the hose or coupling. If necessary,
rubber. lift a large bore hose from use elbows in the piping
complies with federal, state,
the middle of its length system to assure a
• Don’t store uncovered and local environmental
with the ends hanging
hose under fluorescent regulations. straight line connection
down. Doing so can cause with the hose.
or mercury lamps. They
kinking, cover cuts, hose
generate light waves
reinforcement damage, • Protect hose from heat,
WARNING: Take
harmful to rubber. flame, cutting, and
extreme care when and coupling damage.
• Don’t hang hose twisting. Use shields or
flushing out a chemical • Limit the curvature of the clamps to do this.
assemblies on hooks, hose with water. Some hose to the minimum
nails, or other devices chemicals, such as bend radius recommended • Support hose to avoid
which could cut or concentrated acids, may mechanical strain on
by the manufacturer.
damage hose. react with water and cause couplings.
Also avoid sharp bends
The Rubber Manufacturers spattering. These materials at the end fittings and at • Be aware that dropping
Association has published can cause serious personal manifold connections. or dragging the assembly,
separately a series of Hose injury or death if they get chemical incompatibility,
into eyes or onto skin.
• Do not exceed pressure
Technical Information exposure to temperature
and temperature limits
bulletins describing hoses Wear safety glasses, extremes, or extensive
because this could
designed for different gloves and other protective internal coupling abrasion
damage the hose and
applications which clothing to help guard can cause leaks and
ultimately result in serious
detail Maintenance, against this. reduce coupling retention.
bodily injury or property
Testing and Inspection Continue by laying the damage. Monitor pressure
recommendations. Refer hose assembly on a solid and temperature during WARNING: Do not
to the ARPM Catalog of support, allowing air to hose use. use damaged hose.
Publications, issued annually, circulate through it. This
to determine the availability helps extend the hose life.
• Never allow chemicals, Doing so could result in
of the latest edition. solvents, or any other serious personal injury
Further, store the hose in
Bulletins published include hazardous materials or death.
a cool, dark, dry place at a
the following: to drip onto ground.
temperature ideally between
Always comply with
Publication No. 50°F and 70°F.
environmental laws.
lP 11—1— Steam Hose
lP 11—2— Anhydrous
Ammonia Hose
lP 11—4— Oil Suction and
Discharge Hose
lP 11—5— Welding Hose
lP 11—6— Fire Hose
lP 11—7— Chemical Hose
IP 11—8— Fuel Dispensing
Hose
Chemical Resistance Chart Content Provided courtesy of EATON 15
GENERAL HOSE INFORMATION
Hose Maintenance
GENERAL HOSE INFORMATION
Hose Maintenance

CLEANING HOSE ASSEMBLIES


Cleaning of hose assemblies If you choose the soak Class Oil Resistance The effects of oil on rubber
should be done at a facility tank method, the cleaning Rubber hose is used depend on a number of
with the means of disposing solution usually caustic soda to convey petroleum factors that include the
of wastes and hazardous and water- should be no products both in the crude type of rubber compound,
materials properly. All water more than 150°F. Gently the composition of the
and refined stages. The
and/or cleaning solutions lay the hose in the cleaning oil, the temperature and
aromatic content of refined
used should be retained and solution to prevent it from time of exposure. Rubber
gasoline is often adjusted
disposed of in a way that splashing. compounds can be classified
to control the octane rating.
complies with applicable Soak the hose no more The presence of aromatic as to their degree of oil
laws. than 15 minutes to prevent hydrocarbons in this fuel resistance based on their
the hose from becoming generally has a greater effect physical properties after
Eaton Industrial does not
brittle with a shortened on rubber components than exposure to a standard
recommend that distributors
service life. Flush the hose do aliphatic hydrocarbons. test fluid. As a guide to the
handle hose assemblies
thoroughly with clean Aromatic materials in user of the hose in contact
that have not been cleaned
water. After making sure contact with rubber tend with oil, the oil resistance
properly.
that all the water is drained to soften it and reduce its classes and a corresponding
When you clean a tank or description are listed.
from the hose, store the physical properties. For long
change the materials to be
hose in a cool, dry place. lasting service, the buyer of
transferred, clean the hose
Once the hose has cooled gasoline hose should inform
assemblies. Three methods
(approximately 45 minutes), the hose manufacturer of
can be used: the soak tank,
cap the ends to keep the aromatic content of the
the closed loop system, or
contaminants out. fuel to be handled so that
the rotating brush. The most
the proper tube compound
appropriate method will The second method of
can be recommended for the
depend on the hose use and cleaning is the closed-loop
specific application.
location. system. With this method,
the caustic solution used
to clean the tank is also
WARNING: Use of pumped through the hose Physical Properties After Exposure to Oil
pressure wands to and back to the tank.
clean hose is not Typically, fluid is 180°F Volume Tensile
and is pumped through the Change Strength
recommended. The high Maximum Retained
concentration of heat and system until the tank is
clean. Class A +25% 80%
pressure in a confined area (High oil resistance)
can damage the hose inner When the cleaning process Class B +65% 50%
tube and lead to hose is complete, flush the hose (Medium-High oil resistance)
bursting, leakage, thoroughly with water. Class C +100% 40%
spraying, or end blow-offs. Store the hose in a cool, dry (Medium oil resistance)
This could cause serious place. Cap the ends to keep
personal injury or death. contamination out.

WARNING: Always WARNING: Strong


wear safety glasses, acids should be
gloves, and protective thoroughly drained prior to
clothing when cleaning and after cleaning to avoid
hose, no matter which an exothermic reaction.
hose cleaning method you
use. Otherwise, burns,
blisters, eye damage or
other injuries could occur.

16 Chemical Resistance Chart Content Provided courtesy of EATON


GENERAL HOSE
GENERAL HOSE INFORMATION
INFORMATION
Troubleshooting
Hose Maintenance

WARNING: Selection 2. Problem: Cracks in the 6. Problem: Hose is kinked


of the proper hose for hose cover can be caused due to exceeding the
the application is essential by prolonged exposure minimum bend radius of
to the proper operation to sunlight, ozone or high the hose. The result is
and safe use of the hose temperatures. damaged reinforcement.
1. and related equipment.
Solution: Store hose in cool Solution: To avoid this
Inadequate attention to
dark areas when possible. problem, check the
selection of hose for the
Do not store or use the hose minimum bend radius of the
application can result in
where the recommended hose and route the hose so
serious bodily injury or
temperature rating is exceeded. the minimum bend radius is
property damage. In order
not exceeded.
2. to avoid serious bodily 3. Problem: Cuts, gouges,
injury or property damage or tears in hose tube can 7. Problem: Improperly
resulting from selection be caused by improper banded shank may create
of the wrong hose, you cleaning with high-pressure a possible leak path.
should carefully review the water wand. Solution: Make sure
information in this catalog.
3. Solution: Do not use high the coupling is secured
Hose failures can be pressure water wand to clean tightly and according
caused by conditions such hoses. Instead, three cleaning to manufacturer’s
as excessive pressures, methods are commonly used: specifications. Bands
fluid incompatibility, the soak tank, the closed loop should be placed inside of
extreme temperatures and system or the rotating brush. the barbs on the coupling
4. many more. Eaton has The most appropriate method shank, toward the coupling
illustrated below some will depend on the hose use side. The band farthest from
of the more common and location. the hose end should be
failures. If the conditions tightened first. If two bands
4. Problem: Bubbling and
you are experiencing are are present, Eaton suggests
flaking of the tube material
not listed, please contact rotating the clamp buckles
caused by the tube not
5. Eaton Technical Support 180° from each other.
being compatible with the
for North America at
chemical being conveyed. 8. Problem: Overtightened
1-888-258-0222 for global
Solution: Check the chemical band could cause leaks,
technical support contact
resistance guidelines to spraying and end blow-
your local Eaton technical
make sure the hose you are offs. Band was applied
representative.
using is compatible with the with excessive pressure
6. 1. Problem: The hose has chemical(s) being transferred. and cut the cover
exposed reinforcement Also, make sure the hose of the hose causing
and a loose cover. This can handle the application reinforcement to be
could be caused by an temperatures. exposed.
abrasive environment or Solution: Do not attach
the life of the hose has 5. Problem: Deterioration of
bands at pressures that are
7. been exceeded. the hose tube has caused
too high. Apply the bands
the reinforcement to be
Solution: Route hose to the manufacturer’s
exposed. This may be
properly to avoid excessive recommended settings.
caused by abrasive material
abrasion. Some hoses are
being conveyed through 9. Problem: The steam hose
made with materials that
a hose not made for this has developed cracks in
handle abrasion better.
8. abrasive material or hose the cover due to heat in
life has been exceeded. the application.
Solution: Make sure that the Solution: Steam hose has
hose can handle the material a limited service life. It
being conveyed. Possibly use should be inspected before
a hose with a thicker tube. every use. Any crack that
9. exposes the reinforcement is
a reason for the hose to be
removed from service.

Chemical Resistance Chart Content Provided courtesy of EATON 17