You are on page 1of 86

ANSA v19.1.

x Release Notes Introduction

Release Notes

v19.1.x

BETA CAE Systems 1


ANSA v19.1.x Release Notes Introduction

BETA CAE Systems International AG


D4 Business Village Luzern, Platz 4
CH-6039 Root D4, Switzerland
T +41 41 545 3650, F +41 41 545 3651
ansa@beta-cae.com
www.beta-cae.com

BETA CAE Systems 2


ANSA v19.1.0 Release Notes Introduction

Release Notes

v19.1.0

BETA CAE Systems 2


ANSA v19.1.0 Release Notes Introduction

1. Introduction
This document contains all the information about problems fixed during development of ANSA from
version 19.0.2 to version 19.1.0.

NOTES:
 ANSA databases saved by ANSA v19.1.0 can be opened with v19.x.x but not with v18.x.x or
previous versions.

Copyright notes:

All other company and product names mentioned in the software and its documentation are property, trademarks or
registered trademarks of their respective owners.

BETA CAE Systems 4


ANSA v19.1.0 Release Notes What’s New

2. What’s new in v19.1.0


General
General When opening an ANSA database with errors and auto-fixes have been performed, a
pop up message now appears, prompting to open ANSA_CheckDB.log file. Log file
can also be accessed via Utilities> Check Database Analytics.

ANSA-77986

Input/ Output STL

Gzipped files are now supported.

BCS-1351

Subsystems and Includes Colours are now exported during output from ANSA to
solvers file format.

ANSA-78888

Settings All the Product Tree Editor settings are moved to separate tab.

ANSA-75562

Utilities Cut Plane

Show Complete Solids option is now supported for light volume representation.

ANSA-68097

Deck Info

Mass information about KIN_BODY entities is now available in the Deck Info report

59583, ANSA-38208

Snapshot

The ability to include application floating windows is now available by activating


"Include application floating windows" flag in Settings.

48150, ANSA-30227

Snapshot tool now allows to take snapshots of pulldown menus hierarchy by using
the "Active popup" picture mode and the setting "Include active popups parent
popup".

ANSA-59591

Snapshot now shows the preview of Faces> Plane Cut.

BCS-2173

BETA CAE Systems 5


ANSA v19.1.0 Release Notes What’s New

Utilities Transform [Copy]

The Part field of Transformation options is now enhanced with the "Current Part" and
"Existing Part" options and the PID field with the "Current Property" option.

ANSA-70150

Lists The selected entities of a list are now marked on the vertical scroll-bar. This new
feature provides an overview of the selected entities location in very big lists.

ANSA-77930

Database ASKETCH
Browser
Sketch entities are now able to be visualized as independent entities and handled
through the DB. They are also accessible through scripting.

ANSA-80416

LOCK VIEW

Stored Lock Views are now able to send their content to the Current Function (Send
to: Current Function).

60948, ANSA-39188

Feature Loop
Selection Feature Line

Functions now support the selection of FE perimeters.

ANSA-58581

Focus Lock [Store Lock]

A drop down menu in the "Name" field of the "New Lock" window now provides the
names of any existing locked views.
Text auto-completion is also provided, when typing coincides with the existing
names.

BCS-397

BETA CAE Systems 6


ANSA v19.1.0 Release Notes What’s New

Isolate Short Path [Leak]

In case errors exist in the mesh, the "Checks Manager" window now pops-up
indicating them.

BCS-1448

View The MODEL draw mode option in META Viewer is now also supported through
KOMVOS.

BCS-2615

CAD Import/ Export


General SpaceClaim

Version 19.1 is now supported.

ANSA-69033, ANSA-72098

Import Progress bar

The progress bar during translation is now more accurate.

BCS-2139

Translators CATIA

The following attributes are now read, when importing a 3DXML file:

TSLA_PART_NUMBER
TSLA_CA
TSLA_GenerateDO

BCS-647

Export JT

Connection point name is now exported as PMI.

BCS-211

Product Tree CAD to ANSA [Settings> Conflicts]


Editor/ Model
Browser Properties, Materials and other conflicts that appear when merging the translated
parts are now controlled by the new "Conflicts" tab.

64337, ANSA-41642

BETA CAE Systems 7


ANSA v19.1.0 Release Notes What’s New

Product Tree CAD to ANSA


Editor
JT assembly files can be read in Product Tree Editor through the File>Input model
definition. In a next step, the CAD to ANSA function can be used in order to translate
the JT referenced files.

ANSA-71585

CAD to ANSA [Settings]

"Open group files" has been added; by default the checkbook is not activated,
meaning not to translate entities referenced by groups.

ANSA-54325

CAD to ANSA Translators


Input Input of solver files are now fully supported during CAD to ANSA alongside CAD and
ANSA files.

ANSA-78957

GUI
General Feature Selection

"Pick" button has been added in the Feature Selection toolbar to activate the Pick of
an open list.
In case more than one lists are open, the button affects the last opened/used one.
A default and modifiable keyboard shortcut Alt+P is also available.

ANSA-76640

Unchecked [RMB [Show]]

Small CONS are not highlighted anymore; info about small CONS is printed in the
ANSA Info window.

64541, ANSA-41784

The Views Manager now allows customization and recording of additional Default
views (typically: F keys). These may be recorded in "views" files, re-used between
databases and shared with META. Capability had already been partially available.

19607, ANSA-11355

BETA CAE Systems 8


ANSA v19.1.0 Release Notes What’s New

Settings Mouse/Keyboard> Mouse Wheel [Invert zoom direction]

New setting has been added to enable controlling the zoom direction with mouse
wheel.

BCS-578

Utilities Annotations

The same annotation is now able to be attached to multiple model entities.

ANSA-72041

Quality Criteria [Presentation Parameters> Draw interior of solid mesh]

When the option is enabled, while Drawing Styles> Wire is disabled, the latter now
prevails, i.e. the Wire is not drawn.

ANSA-70846

Snapshot

"Custom" size settings are now kept, when saving GUI settings.

ANSA-73881

Model Browser
General It is now possible to modify fields of model browser entities that belong to higher level
containers, through the Quick Modify function in the column header and the Modify
option of the context menu. For example, the 'Modify' option is now available in
context menu of Subsystems that are placed under a Simulation Model.

ANSA-62364

New option "Map front" added in Mass Trimming creation, to map only the front
elements when connectivities overlap.

57441, ANSA-36736

When the Model Browser is in Icon view mode it will not display the thumbnail icon of
very large volumes, in order to avoid delay in opening.

ANSA-81636

The attribute "Is Empty" is now available for all Model Browser Containers, in order to
facilitate the identification of empty entities through scripting, as well as the compress
functionality.

ANSA-67394

BETA CAE Systems 9


ANSA v19.1.0 Release Notes What’s New

General The "DM Update Status" column, which displays the status of the loaded Model
Browser containers in DM, now shows a new status for those items that have
changed since they were downloaded from DM and therefore, they need to be saved
again. So, from now on, the DM column can display the following status values:

white: For items that do not exist in DM


green: For items that exist in DM and are up-to-date
orange: For items that exist in DM and have updated versions or newer timestamp
grey: For items that have some alternative in DM (e.g. a different representation, a
different variant, etc.)
magenta (new): For items that have been modified since they were downloaded from
DM and therefore, they need to be saved again in order to prevent data loss

ANSA-74232

Subsystems Contents [Check Missing & Misplaced]

Several improvements were made in the detection of missing and misplaced


properties of Subsystems.

ANSA-79624

DM [Upload Interface Representation]

It is now possible to add to DM the interface metadata of a subsystem that already


exists in DM, without having to save/output the subsystem file again. This is
particularly useful in _migration_ workflows, where the subsystem file already exists
and it is just copied in DM, and the interface metadata, which is necessary for "Smart
Assembly" functions, need to be "appended" at a later time.

The function is also available through scripting.

ANSA-73209

Simulation Output
Runs
Applying Output from context menu option on Simulation Run, a check for the
compatibility of the combination of the Simulation Model and the corresponding
Loadcase is now performed. In case of fail an appropriate message informs about the
compatibility error and the process is aborted in order to avoid the output of an invalid
file. For example it is not valid to combine a META FRF ASSEMBLY Loadcase,
created with Loadcase Setup Assistant, with a simulation model which has
subsystems of regular type.

ANSA-76804

BETA CAE Systems 10


ANSA v19.1.0 Release Notes What’s New

DM Save in DM

During "Save in DM", if a conflict is detected with data that already exist in the data
pool, it is now possible to write a comment logging the modifications that were made
before creating a new version of the item.

ANSA-77479

Actions Copy to Model [Custom merge Options]

When copying a Part from one model to an other, a new option provides the ability to
open the Custom merge Option window. In this window, any possible ID conflict
between the selected part and the target model can be checked; solving these ID
conflicts per model entity group is now controllable.

ANSA-51881

CAD to ANSA New option is now provided that provides priority to open the attached ANSA files
instead of checking for existing Part representations in DM ("Use attached ANSA files
instead of checking in DM").

ANSA-78955

It is now able to stop the CAD to ANSA process through the Pause/Break button.
Once pressed, the button waits for all currently running parallel jobs to conclude and
then terminates the process.

ANSA-77919

Replace The following improvements have been made regarding the update of Connections\
Connectors\ GEBs connectivity during Replace Part:

The connectivity of affected Connections\Connectors\GEBs is now updated even in


cases where properties are referred.
If there are more than one incoming\ outgoing parts\ properties, a matching is
perfomed based on geometrical similarity.
In such case, the references of outgoing parts\properties are updated only if these
are matched with an incoming part\property.
This behavior is controlled through the 'Update connectivity with tolerance' option in
Replace Parts Advanced Options or through the
'Update_Connections_Connectivity' and
'Update_Connections_Connectivity_Tolerance' options in ANSA defaults.

ANSA-71036, 49730, ANSA-31295

Scripting GetPartLinks()
GetPartInstances()
ConnectPartInstances()
BreakPartInstances()

New functions are supported to manipulate or inspect Part Instances and Part Links.

ANSA-72862, BCS-1017

BETA CAE Systems 11


ANSA v19.1.0 Release Notes What’s New

Scripting base.GetEntityDMUpdateStatus(entity)

The "DM Update Status" of an entity is now able to be identified through scripting. A
constant value is returned according to the value of "DM Update Status".

ANSA-80026

Compare
General It is now possible to customize how the Models are displayed while navigating the
differences.

ANSA-78995

Data Management
General Save in DM

A new script function is now able to run automatically, when saving a part/subsystem
in the DM; this may be achieved by defining the new options via the ANSA.default
settings:
PrePostSaveRepresentationScriptFunctionName
PrePostSaveRepresentationScriptFilePath
The function runs 3 times when applying Save In DM: Before, During and After the
save representation operations.
The arguments of the function are:
-entities: The parts/subsystems that are being saved
-deck
-info_dict: A dictionary. It contains one member whose value is the state where the
script function is called:
{"PrePostSaveRepresentationFunctionCallState", state}
where:
-state=0 -> before save representation
-state=1 -> during save representation
-state=2 -> after save representation

ANSA-77285

Input Input model definition

Solver files are now supported in PLMXML model definition input.

BCS-1705

Tools Settings> ANSA defaults> Replace Part Parameters [Realize Connections]

A new option has been added so as to control if reapplication of connections will take
place when applying Parts>Replace or DM>Download operations on Parts.

ANSA-77800

BETA CAE Systems 12


ANSA v19.1.0 Release Notes What’s New

DM Browser Export

The selected items in DM Browser list are now able to be exported to a specified
directory, while the Representation File of a keyword File Type item can be opened in
text viewer.

ANSA-46569

Refresh

The DM database Refresh functionality now recovers the attributes of DM objects


with higher accuracy.

ANSA-76066

Utilities [Rebuild from Disk]

The "Refresh" function has been renamed to "Rebuild from Disk", in order to reflect
the operation carried out. The function, available only for file based DMs, rebuilds the
DM database by scanning the DM directory contents. A warning window now
appears to inform the user for the operation that will be carried out and confirmation
is requested in order to proceed.

ANSA-78266

Scripting base.GetIncludeReferenceFileText()

It is now able to get the "Text Edit" of an Include via scripting.

ANSA-48192

dm.GetObjectHierarchyIds()

New function has been added to get hierarchy related information for all directly
contained DM objects.

ANSA-81674

ANSA can now act as a remote execution worker, also when running in GUI mode.

ANSA-75791

BETA CAE Systems 13


ANSA v19.1.0 Release Notes What’s New

Connections & Assembly


General Connectivity [Replace]
Connectivity [Remove]
Connectivity [Add]

When clicking Add/Remove all the shells from the connectivity P1, P2, ..., Pn will be
highlighted for all selected connections.
If all connections share the same connectivity, then all the affected shells will be
highlighted as blue.
If at least one connection has different connectivity, then all the affected shells will be
highlighted as cyan.
Moreover, a warning window message has been added, if part already exists,
whether to "Allow connection to connect the same (part/prop/entity) more than
once?".
Closing, a "Don't ask me again" checkbox has also been implemented, which can be
reset via Tools > Settings > Connections setting.

ANSA-69869

When a connection is realized with FE-Representation Ref.Library items, Properties


IDs now respect Settings > Decks > Create new IDs, when set to [above the current
range]. As a result, the second-created entities will properly follow the above settings.

ANSA-77251

A new mechanism for the evaluation of the status of connections has been
implemented.
According to the previous behavior, a realized connection would lose the 'Ok' status
for almost every change that occurred in the connected parts. Such changes
included, among others, the editing of any field in the entity card of a connected
property, and the mesh reconstruction in a remote to the connection area.
As a result, the loss of a connection's 'Ok' status could not be used to indicate a
problematic condition.
Now the connection status is evaluated in a more precise way. Changes in the
connected parts that do no affect the integrity of a realized connection, do not lead to
loss of the 'Ok' status.

43885, 46628, ANSA-27516, ANSA-29234

Settings Connection Manager Parameters> Connection Manager General Parameters [force


new ents in parent include]

New option has been added to force the realized entities of a Connection to be set in
the Connection Include, instead of the Current one.

BCS-1689

Connections [Connector/GEB/IO points]

The contents of the Name, Comment, and user_notes fields of a


CONNECTOR_ENTITY card can now be passed to the corresponding fields of the
elements created by the connector.

ANSA-75199

BETA CAE Systems 14


ANSA v19.1.0 Release Notes What’s New

Bolts Speed enhancement when realizing solid bolts on second order tubes.

ANSA-48715

Connectors When creating a new Connector Entity between 2 Assembly Points the direction of
the Connector Entity is now automatically calculated and filled in the card.

ANSA-64962

The name of the Connector/ GEB can now be passed to the created entities. This
option is controlled via the Tools> Settings> Connections [Connector/Geb/IO], by
activating the respective flags.

ANSA-57531

A POINTs/ LC It is now possible to control the id, name and comment of the node marked by an
POINTs Assembly or Loadcase Point. This is achieved by activating the new A/LC-POINT
option "Copy attributes to Interface Node", which will force the Id, Name and
Comment of the A/LC-POINT to the interface node.

For the control of the node id in particular, the moment the A/LC-POINT is applied,
the node is automatically marked as FROZEN_ID = YES. If this set-up is in place but
ANSA fails to allocate the desired node id for the interface node on Apply, the A/LC-
POINT will not be applied successfully. Additionally, if while the A/LC-POINT is
successfully applied, the marked node loses its id, the A/LC-POINT will lose its ok
status and will report the id incompatibility with status "interface node incompliance".

ANSA-75601

Connection Connectivity [Add]


Manager
A new option is now supported to automatically sort the complete connectivity order
after the addition of a new flange. This option is saved in ANSA.defaults.

BCS-2018

Edit Location

New option has been added in the context menu of a connection entity in the
connections list. Using this functionality, the location of a Connection can easily be
changed by a screen selection.

BCS-2030, ANSA-71069

Connection properties such as Spotweld/ Bolt Diameter (D), Seamweld width (W)
and orientation, Adhesive Width (W) and Height (H) etc. are now represented and
synchronized by respective xMCF 3.0 parameters.

ANSA-78372

Convert Cnctn to Cnctn

The option to create 3D points at the position of converted Spotweld Points has been
added.

ANSA-76251

BETA CAE Systems 15


ANSA v19.1.0 Release Notes What’s New

Convert FE to Cnctn Pts

Elements that consititite SPIDER2s are now converted to spotwelds with FE-
Representation SPIDER2.

ANSA-67431

When a Heat Affected Zone is identified, the FE Rep Type of 'SOLID Nugget' is
assigned.

ANSA-77088

FE to Seamline

Function now supports IQUADS (PERMAS WLSCON MPC).

ANSA-80231

Remove The algorithm, when the 'Distance between projection centers' option is activated,
Double has been modified. Now, only the distance of the projection centers is considered to
detect duplicate connections.The distance between projections of the same
connection is not taken into account anymore. If the specified value is larger than the
distance between the projection centers the connections are identified as duplicates.

BCS-2048

Communication between the list of double connections and the graphics area has
been improved; highlighting of the picked connections and Pick from screen has
been implemented.

ANSA-70914

Scripting The respective "tangential_direction" argument is now available for "misc" dictionary
on each call of the PostRealize function for Spotlines.

ANSA-81963

FE Representations
BOLT/ BOLT An Assembly Point that is created during the realization of a Bolt connection will be
NULL SHELL/ now deleted, if the Bolt is realized again having the 'Create Assembly Point' option
BOLT ON deactivated.
SOLID/ BOLT
RIGID
PATCHES ANSA-77179

BETA CAE Systems 16


ANSA v19.1.0 Release Notes What’s New

BOLT ON A new option 'All Tubes Expand Interface To' for Tubes Search in order to expand
SOLID interface either to top/bottom or all rings is now supported.

ANSA-49206

Y-JOINT- It is now possible to specify the width of the FE Representation as a function of the
SHELL/ seamline 'W' value.
OVERLAP-
SHELL/
CRIMP-
WELD-SHELL ANSA-79748

CWELD In NASTRAN, the option Force CWELD Flange criteria has been renamed to Force
SWLDPRM Criteria to follow the NASTRAN terminology.

ANSA-55579

Cohesives A new FE representation type, Pasted Cohesives, has been added to Hemmings. In
this representation, compatible mesh between the inner and the outer flange and
Cohesives are created.

ANSA-73623

DYNA SPOT The capability to assign 'PBEAM ID' 'By Flange Pair' is now supported.
WELD
BCS-680

EDGE-WELD- All the types of FEMFAT BUTT-WELD with respective MAT IDs have been supported
FEMFAT under EDGE-WELD-FEMFAT representation.

ANSA-58843

EDGEWELD A new SeamLine FE-representation is now available, with cross section PENTA-
SOLID HEXA-PENTA definition and Contact interface entity. Options in order to control the
PID assignment and the connection size are also available.

ANSA-79524

BETA CAE Systems 17


ANSA v19.1.0 Release Notes What’s New

FEMFAT When realizing FEMFAT SPOTWELD, the Young Modulus of connectivity parts is
SPOT taken now into account. Specifically, if sheet material is steel, MAT151 and MAT152
are generated for inner and outer zones respectively. If sheet material is aluminum,
MAT154 and MAT155 are generated for inner and outer zones respectively. The
seperation value of Young Modulus for steel and aluminum is defined on defaults.

ANSA-77672

FEMSITE- The FEMSITE Module v44, which features a new Abaqus representation for
SPOTWELD spotwelds, containing Couplings is now supported.
Choosing between the 2 Abaqus-specific representations can be done through
'Abaqus Spec' option.

ANSA-77676

OVERLAP A new 'HEXA-PENTA-HEXA' Cross section definition has been added.


SOLID
ANSA-79523, ANSA-77652

RBE3-SHEL- 'Loose Ends' option to project the ends of the seam line on the detected feature line
RBE3 in order to define the effective length of the connection or not is now supported.

ANSA-80346

Thickness factors for width and height are now supported.

ANSA-82224

The representation can now be applied to solids.


The thickness of shell property of HAZ solid skin it taken by W of connection.
If W=0, T=1 is assigned by default.

ANSA-80232

Double fillet of weld is now supported through Seam Shape = Double-Sided Fillet
setting.

ANSA-80175

SOLID-WELD Solid welds are now always created with curved endings. The following assumptions
are taken into consideration:
-Extension at start/end: unchecked
SolidWeld body is created with curved endings. The total length
of solidWeld body is equal to connection line's length.
-Extension at start/end: checked
SolidWeld body is created with curved endings.
Length: undefined
The length of solidWeld body, without its curved endings, is
equal to connection line's length. The length of curved ending is
equal to MAX( width_left, width_right, height, depth )
Length: defined
As Length: undefined. An extra solidWeld part between solidWeld
body and ending. This extra part has length equal to the defined.

ANSA-75887

BETA CAE Systems 18


ANSA v19.1.0 Release Notes What’s New

SOLID The new scheme 'CONTACT' now offers the ability to use cohesive elements.
NUGGET
BCS-2031

New hexa mesh pattern for PASTED_NODES Sheme and Num of Nodes = 16.

ANSA-55551

A new solid mesh pattern is created in case of 12-Node Solid Nuggets that have the
'Force Pentas in Nugget' option deactivated. The new pattern consists of 8 Hexa
elements.

ANSA-67406

Y-JOINT- The root shells = triple row is now supported by applying offset row in both sides of
SHELL sheet.

22225, ANSA-13098

A new SeamLine FE-representation is now available, with cross section PENTA-


HEXA-PENTA definition and Contact interface entity. Options in order to control the
PID assignment and the connection size are also available.

ANSA-79525

Y-JOINT- The option to generate only HEXA elements is now available. There is also the ability
SOLID not to Reconstruct the corresponding weld area.

ANSA-63814

BETA CAE Systems 19


ANSA v19.1.0 Release Notes What’s New

Topo
CONS Project

Function has been enhanced, so that projection onto to a Work Plane, or Cross
Section plane, is an acceptable option.

60558, ANSA-38901

The newly created CONS can now be added to a SET, when enabling the respective
option of the Options List.

52537, ANSA-33224

Faces Cut

Right mouse click on a CONS (i.e. Join) is now able to be applied also in case its
midpoint is snapped.

BCS-1238

Tangential cut option is now available; selecting a source to cut and hovering on a
CONS or a Feature Line, the triangle feature with the dotted line denotes tangential
cuts from source to hovered target.

ANSA-82736

Mid.Surface [Align Manager]

"Imprint" option has been added to project a CONS to the middle surface, eliminating
problems of mesh flow, e.g. at fillet boundaries.

BCS-606

BETA CAE Systems 20


ANSA v19.1.0 Release Notes What’s New

Faces Mid.Surface [Skin]

Skin user interface has been revised to a much more intuitive and user-friendly
version.
Key-points/highlights:

a) When selecting or deselecting an edge, the resulting re-colorization of the 3 areas


would be directly visible to the user – thus no need to go back and forth until the
desired result is achieved.

b) The user can directly modify the _faces_ color – further increasing convienience in
defining the 3 areas.

c) Edges are highlighted on mouse-hovering to increase clarity during user


interaction.

27969, ANSA-16756

"Run on: Visible/ Selected" parts is now available.

ANSA-76958

A wizard has been added to enable manual edit of the initial Skin result.
It is now possible to edit edges or faces and color the inner/outer/middle of the 3D
description with red/green/blue colours, respectively. In addition, annotations at
problematic areas are now illustrated, describing the type of the error.

46088, ANSA-14622

Curves Create

Normals on hotpoints and grids are now displayed, when hovering in their supposed
direction. In addition, when dragging a normal or a tangent snap is allowed on nodal
and intersected surface entities.

ANSA-82746

Auxiliaries Cross Sections [Multicut]

The option "Apply to" has been added under the Options List. Cross sections are now
able to be created from selected Elements or elements loaded in Morphing Boxes.
The Path shrinkage factor option has also been added, when Apply to [Morph Box] is
selected. It is used to reduce the automatically detected path of the Multicut function.

ANSA-81434

BETA CAE Systems 21


ANSA v19.1.0 Release Notes What’s New

Shell Mesh
General Mesh Parameters [Distortion angle]

Minimum limit of the parameter is now set to 5 degrees, under:

-Basic tab

-Features tab> Fillets treatment> Rows [auto]

BCS-1751

Perimeters Spacing Manual

When Spacing is applied on a perimeter, any previously assigned Number of


perimeter nodes is now initialized.

ANSA-76846

Shell Mesh Fill [Holes]

Solid holes with fillets on geometry are now able to be detected and filled.

ANSA-72690

BETA CAE Systems 22


ANSA v19.1.0 Release Notes What’s New

Shell Mesh Regarding Solid holes option, it is now possible to identify holes with fillets.

ANSA-71912

Improve

It is now possible to save which of the Reshape or Reconstruct to be used for the
mesh improvement.
This is saved in the ANSA.defaults file, via Tools>Settings.

BCS-1446

Elements Release

Automatic creation of FE-Perimeters and Features is now optional and is controlled


by the new setting of the Options List "Copy Perimeters and Features to FE" (default:
On).
When disabled, FE-Perimeters are only created if the Part of the released area
already contains recognized Features.

BCS-2390

To Surface

When function is applied on a part without Fe perimeter the FE perimeter Editor now
automatically opens, in order for the recognition to be directly performed.

ANSA-76887

Octree Wrap [Variable Length]

Improved PID imprinting around sharp features.

ANSA-80780

Scripting base.CalculateOffElements()

Function now accepts array of shells and/or solids as input.

ANSA-73899

Volume Mesh
Checks Mesh [Negative Volume]

A new parameter has been implemented that defines the calculation method
(Partial/Total) of the check. Therefore, from now on, the calculation method of the
check is independent of the calculation method defined in F11>Solids.

61860, ANSA-39848

BETA CAE Systems 23


ANSA v19.1.0 Release Notes What’s New

Structured Layers
Mesh
Improvements in robustness and quality of layer connections on triple and single
boundaries.
(Accessible also through MESH> Volumes> Layers [Create]).

ANSA-80179, BCS-2011, ANSA-64756, 46558, ANSA-29176, ANSA-47321

Improve Fix Quality

New option "Unconstrained 2nd order nodes" has been added to allow unconstrained
movement of the middle nodes, ignoring the bound constraints.

ANSA-64634

Fix Quality is now restricted on non-wall BC type properties. Nodes are only sliding
on BC types: symmetry, velocity_inlet, patch
Nodes are frozen on periodic BCs.

64677, ANSA-41877

In Quad-Tria Interfaces and periodic boundary conditions, nodes are now considered
as frozen and they are not moved.
In symmetry type boundary conditions, nodes are allowed to move only on the
surface.

44200, ANSA-27729

Function's performance has been improved giving a better surface quality.

ANSA-77707

Octree All Octree entities can now be saved and read for re-using in other models. Filters
within Octree should exist prior output. After reading, with "Autoload" the contents of
the octree will be filled accordingly.

BCS-1395

Batch Meshing
Sessions Report

The Error Class message in case of unmeshed volumes has been changed to
"Unmeshed Volumes" instead of "Unmeshed Macros".

ANSA-78790

Scripting batchmesh.GetNewBox()

New function has been added to enable a Box entity creation under a batch mesh
session.

ANSA-73781

BETA CAE Systems 24


ANSA v19.1.0 Release Notes What’s New

Feature Manager
General Newly created features like 2D and 3D Holes, Tubes, Fillets etc. are now directly
listed and managed within the Feature Manager.

ANSA-76889

Design Copy
Actions
When a feature is copied its treatment is now automatically applied.

BCS-2169

Features which are connected to solid elements are now excluded from Design
Actions Move/Copy.

ANSA-71037

DECKs
Properties Mat Sync

The NASTRAN MAT1 is now synchronized with the Abaqus MATERIAL.

BCS-2448

Materials New by Homogenization

Elasto - plasticity and Thermo - elasto - plasticity analysis type is supported for the
homogenization of composite materials with plastic phases.
Automatic RVE mesh generation and FE Homogenization method is available.

ANSA-76402

Utilities Transform [Copy]

In 'Transformation Options' window, using the 'Copy/Expand' options for Set, a new
flag 'Convert Ranges to Entities' has been added which affects the copies of Sets
that involve Ranges of entity ids.

47486, BCS-1118

AUXILIARIES CONTACT [Assistant]

When a template is used in the Contact Assistant the Contact type field is now
disabled and set according to the selected template contact type.

ANSA-52090

BETA CAE Systems 25


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES SET

When the Sets>Copy function is executed, a new option is available in the Options
List window, which enables suspend of set expansion for nested sets. This option is
also added in the ANSA defaults settings (Settings>Decks>Copy: Sets option
Expand/None).

58100, BCS-1121

Fringe EL TEMP MENU

Line Elements are now colored according to the temperature that is assigned to their
nodes.

BCS-1874

Scripting base.OptimizeSetContents()

New function has been added to optimize set contents by replacing them with higher
level entities. If possible, Nodes are converted to Elements, which in turn are
converted to Properties. The function can also (optionally) replace Solid Properties
with solid skin (SOLIDFACETs).

ANSA-77933

Laminates
AUXILIARIES LAMINATE [LIST]

As soon as a laminate property is selected in the Laminate Tool, the base mesh now
becomes transparent.
If a single layer is selected, this layer becomes shaded; if more than one layer is
selected, the layers remain transparent.

33745, ANSA-20770

LIST Generate Report

In the .png images that are generated for each layer the base mesh will be
transparent, providing better visualization of the layer.

BCS-2636

Tools
Batch Mesh Wrap Scenario

The option for Seed points in the Wrap process is now available through the Batch
Mesh tool.

BCS-1759

BETA CAE Systems 26


ANSA v19.1.0 Release Notes What’s New

Features Parameters

Minimum width calculation is now supported as recognition parameter for Flanges


2D.

60052, ANSA-38541

Task Manager Tasks [Optimization Task]

The Definition and Execution modes of the Optimization Task from now on alter
automatically.
Symbols appear next to undefined task items providing information about their status.
The 'X' symbol appears next to an undefined task item, while the '!' symbols lead
towards it.
The Optimization Task can be executed once all task items are properly defined.

ANSA-79161

Undo function would cause the Task Manager list collapse, needing manual
expansion after each application of Undo button.

ANSA-68963

Checks Connections

In the results' list, "Show Options" context menu option has been added to control the
"Fe rep" and "Connectivity" visibility.

58546, ANSA-37485

Duplicate Elements

Apart from the speed execution that has been significantly increased, the function
had been enhanced as follows:
- It extracts a new, more enlightening report.
- It offers the new check parameter 'Report semi-duplicate solids', for searching semi-
duplicate elements. Such elements could be a combination of Hexas and Tetras, for
example, that share common nodes.
Nevertheless, the old functionality is still available, via the option
'Enable_deprecated_Duplicate_Elements_check', under Tools > Settings > ANSA
defaults > Checks Manager Options.

ANSA-66571

BETA CAE Systems 27


ANSA v19.1.0 Release Notes What’s New

Checks Penetration [Intersections]

Check execution now displays the Part/PID Name(s) of the affected Part/PID
respectively, as separate attributes in separate columns.

BCS-705

Settings ANSA defaults>Contact Flanges Option [Create Type]

Accepted values for the above option have been changed to "Contact", "Isurface"
and "Pretension".

ANSA-79114

ANSA defaults>Contact Flanges Option [Enable Merge of neighbouring Contacts,


Exclude Shells/Solid Facets connected to Connections, Include Connection
Elements, Pick Entities, Use Finer Mesh as Master]

Accepted values for the options have been changed from 0/1 to true/false.

ANSA-79114

ANSA defaults>Contact Flanges Option [Search for template on:]

The name of the above option has been changed from "Search for template on
reference Database" to "Search for template on:".

ANSA-79114

ANSA defaults>Contact Flanges Option [Update Clearance/CINTERF]

The option "Update Clearance / CINTERF" of Contact Flanges Data card can now be
saved in ANSA.defaults file.

ANSA-79114

Safety
General The name of the target point is written in each new master file, if keyword *TITLE is
found in master file. This applies to all safety tools that support the multi positioning
functionality.

ANSA-80413

Dummy Articulation

GNS Files [Input .ses file] button has been added to allow the selection of a GNS
session file and its execution.

BCS-1031

For PAM-CRASH dummy models, 'Rotations' keyword of pos file is now supported.

BCS-1350

BETA CAE Systems 28


ANSA v19.1.0 Release Notes What’s New

Dummy The Tree View order of the *.pos file is now maintained.

BCS-1931

For PAM-CRASH dummy models, the precision definition is now supported for writing
Generator session files.
The definition is via the parameters 'Generator session file rotation precision' and
'Generator session file translation precision' as found in the ANSA Settings >
OUTPUT PARAMETERS > Pam-Crash output options.

BCS-1934

Output information for all the joints into the GNS session file is now supported.

BCS-1936

Input/ Output

For PAM-CRASH dummy models, input and output of Generator session files has
been updated and re-organized.
Input is available through:
-Articulation tool> Rotate tab> GNS files
-the KIN_POSITION context menu list of 'New' 'From GNS file'
Output is available through:
-Articulation tool> Rotate tab> GNS files
-the KIN_POSITION context menu entity of 'Convert to' 'GNS file'

BCS-1933

Output

DEFPOSITION keyword in PAM-CRASH positioning files is now supported.

ANSA-80913

For PAM-CRASH dummy models, if a positioning file is retrieved, the KIN_JOINT


entities that get created get the ID of the corresponding FE joint.
Also, they reference this FE joint ID in the FE_JOINT field.

BCS-1932

Seat Generator session files for the positioning of PAM-CRASH seat models are now
supported. Input is available through the KIN_POSITION context menu list of New
[From GNS file].

ANSA-76784

Pedestrian It is now possible to position an impactor in "Test Point" mode that is made only of
solid elements.

ANSA-70379

A button is added that controls visibility of debug entities within the Pedestrian tool.

ANSA-80200

BETA CAE Systems 29


ANSA v19.1.0 Release Notes What’s New

Pedestrian For the Positioning tab and the Multi-Point Mode, in the Options the flag 'Copy files in
each directory' is now supported.
It works in cooperation with the 'Use relative name for includes'. In case both flags
are enabled, the function will work as it used to work till now when 'Use Relative
Names' was enabled. In case 'Copy files in each directory' is not enabled while the
other is, the tool will try to calculate a relative path for each target point's master file
according to the initial master file and the output directory.

ANSA-76883

EUPhase2 EC Proposal for legform has been updated to the latest UN-R127
guidelines with the below
• 42mm offset is applied by measuring along Y-axis
• 1003mm is set as the upper limit.

BCS-952

From now on in the NCAP protocols, the projection of the Target Points is horizontal
if the center point of the respective WAD line (instead of each Target position) is
forward the BLE.

ANSA-77943

Interior Interactive 201U

A step-by-step interactive marking tool for FMVSS201U has been added. The
specific tool offers the ability to:

Calculate each Target Point separately


Recalculate a Target Point and its dependencies after a change on the auxiliary
entities (planes, curves , points)
Mark both sides of the vehicle
Provide a Flow diagram of all the Target Points

ANSA-77831

Target Point On Coordinates

Target points can now be created by directly giving the required coordinates.

37196, ANSA-23021

When Target Points are created massively, a unique index is now assigned at the
and of the name of each entity.

ANSA-64218

BETA CAE Systems 30


ANSA v19.1.0 Release Notes What’s New

Scripting base.ASeatbelt()

In Aseatbelt's create_component() and create_all_components() methods, a boolean


argument is added for enabling the interactive edit of the seatbelt component.

BCS-1601

Seatbelt Tension tool has been supported in python script using the object
'tension_component' of 'ASeatbelt' method.

ANSA-76057

NASTRAN
General SPLINE2
SPLINE1
PAERO1
MKAERO1
FMETHOD
FLUTTER
FLFACT
CAERO2
CAERO1
AERO
AEFACT

New keywords for aeroelastic analysis (SOL 145) are now supported.

ANSA-73220

Output The output of free format is now supported.

BCS-2136

Materials MAT1F in MAT1 card, MAT2F in MAT2 card, MAT8F in MAT8 card, MAT9F in MAT9
card and MAT10F in MAT10 card are now supported.

BCS-623

Model Ability to assign the regular FE representation of a Subsystem as a Display Model of


Browser a Reduced representation of the same Subsystem has been provided from within
Model Browser.

ANSA-75583

ELEMENTs GENEL

General Element (GENEL) support and visualisation has been introduced.

5346, ANSA-3154

BETA CAE Systems 31


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES FIELD POINTS

New option with which the orientation of a Field Point of ISO3744 type can be defined
with reference to a coordinate system has been added.

ANSA-60644

SOL200 [DVPRELi]

The DVPREL1 keyword now supports Thickness, for segment(s) of the cross section
with specified properties (cseg_prop field) and PBxSECT beam properties.

ANSA-78556

BCs ISTRESS
IPSTRAIN

IPSTRAIN and ISTRESS keywords for strain and stress initial conditions respectively
are now supported, accessible also by the newly created menu buttons.

32761, ANSA-20158

Scripting Ability to handle the creation and editing of TSTEP keyword through
base.CreateEntity() and base.SetEntityCardValues(). An Example is shown below:

ANSA-74033

NVH Console
General New indication, if a component has modified modes in Diagram view and Loadcase
manager.

ANSA-75461

DOE The capability to run DOE studies for Bush connectors from within NVHC is added.
The Bush connectors that should be used for the study are selected from a list that
pops up and then experiments for different values of the bush properties are created
by the tool based on the sampling algorithm that is selected. Finally, the job is
submitted and in the end a _.metadb_ file with the DOE results is being created.

ANSA-80070

The option "BSR" (Bush Series Reduction) is added when running DOE for selected
bush connectors from within NVH Console. If this option is used, the whole assembly
is reduced to a matrix of Transfer Functions (FRF representation) which are necessary
to perform the DOE study. That provides a very significant performance increase for
the DOE study of the whole assembly.

ANSA-79780

BETA CAE Systems 32


ANSA v19.1.0 Release Notes What’s New

LS-DYNA
General INITIAL STRESS SECTION

IZSHEAR is now supported; it gets output when the Output Format is set to R971R10
(or later).

BCS-2071

LOAD [HEAT GENERATION]

All function-related keywords are now supported.

ANSA-53511

Input/ Output Connection type COUPLER of PRIMER's mechanisms is now supported.

ANSA-76403

Output In case entity's name does not exist, '_TITLE' extension is not output for
*DEFINE_COORDINATE and *HOURGLASS keywords.

BCS-1009

Materials *MAT ADD EROSION

It is now supported as a separate entity.

ANSA-81451

For *MAT_240, the fields LCG1C and LCG2C have been supported for R9 and on.

BCS-2309

*MAT_VACUUM is now supported.

BCS-2330

MAT_162 *MAT_COMPOSITE_DMG_MSC is now supported.

BCS-1054

MAT24 MAT_PIECEWISE_LINEAR_PLASTICITY_MIDFAIL and MAT24


MAT_PIECEWISE_LINEAR_PLASTICITY_STOCHASTIC are now supported.

BCS-1252

BETA CAE Systems 33


ANSA v19.1.0 Release Notes What’s New

Materials The keyword of the below materials has been changed, so as to be in full accordance
with the solver:
MAT200 MAT_SPRING_ELASTIC -> MAT_S01 MAT_SPRING_ELASTIC
MAT201 MAT_DAMPER_VISCOUS -> MAT_S02 MAT_DAMPER_VISCOUS
MAT202 MAT_SPRING_ELASTOPLASTIC -> MAT_S03
MAT_SPRING_ELASTOPLASTIC
MAT203 MAT_SPRING_NONLINEAR_ELASTIC -> MAT_S04
MAT_SPRING_NONLINEAR_ELASTIC
MAT204 MAT_DAMPER_NONLINEAR_VISCOUS -> MAT_S05
MAT_DAMPER_NONLINEAR_VISCOUS
MAT205 MAT_SPRING_GENERAL_NONLINEAR -> MAT_S06
MAT_SPRING_GENERAL_NONLINEAR
MAT206 MAT_SPRING_MAXWELL -> MAT_S07 MAT_SPRING_MAXWELL
MAT207 MAT_SPRING_INELASTIC -> MAT_S08 MAT_SPRING_INELASTIC

ANSA-75066

Negative values of IDAM field are now supported in the *MAT_ADD_EROSION card
in order to utilize multiple DIEMs.

ANSA-64614, ANSA-75580

Negative values of IDAM field are now supported in the *MAT_ADD_EROSION card
in order to utilize multiple DIEMs.

BCS-641

Checks Curves [Axes]

'Material curves quality criteria' option has been added for curves used in material
definitions, in order to control max limits for yield stress, plastic strain, scale factor
and strain rate.

ANSA-48921

Contacts

Rigid structures attached to tied segments are now identified in case of offset-type
tied contacts.

46459, ANSA-29109

CON- PLANE
STRAINED
The keyword *CONSTRAINED_LOCAL is now supported.

47692, ANSA-29944, BCS-2254

BOUNDARY DFLUX

The keywords *BOUNDARY_FLUX_SEGMENT and *BOUNDARY_FLUX_SET are


now supported.

ANSA-43768

BETA CAE Systems 34


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES BOX

The local coordinate system can now be defined by axis or by cord through the
"defined by" pull down menu of the *DEFINE_BOX card. Minimum and maximum
values are defined in local system whether axis or cord option is selected.

Several changes in box have been made:

 When creating a box in LS-DYNA and then turning to RADIOSS or other


decks, the definition follows LS-DYNA and has the same card and fields as
LS-DYNA. So in scripts, the field values can be extracted by calling LS-DYNA
fields.
 The same is when creating a box in RADIOSS and turning to other decks.
Previously the card had mixed LS-DYNA and RADIOSS fields. Now the fields
are renamed to follow RADIOSS.
 In decks that there is no definition of Box, the Box is defined by default with
RADIOSS definition and only if it has been created in LS-DYNA, follows LS-
DYNA.

BCS-556

CONTACT

For the *CONTACT_AUTOMATIC_SURFACE_TO_SURFACE_TIEBREAK_


{OPTION} and
CONTACT_AUTOMATIC_ONE_WAY_SURFACE_TO_SURFACE_TIEBREAK_{OPT
ION}
that have OPTION of 9 or 11, the fields SFLS and NFLS now support negative
values.

ANSA-54687

CONTROL

Option JOBID for *KEYWORD is now supported.

ANSA-52273

CONTROL [CONTROLs]

*CONTROL_MAT keyword is now supported.

BCS-2403

GEB [GEB MT]

MassOnAllNodes KEYWORD has been introduced, in order to control the final result
of the ELEMENT_MASS card.

ANSA-75353

BETA CAE Systems 35


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES RIGIDWALL

The fields NSEGS, VL and HEIGHT are now supported for the
*RIGIDWALL_GEOMETRIC.

ANSA-78163

TRANSFRM

The A_PARAMETER assignment via F3 is now supported for the fields of the
*DEFINE_TRANSFORMATION keyword.

ANSA-66509

The option POS6N is now supported.

ANSA-62753

Mirror transformation option is added.

ANSA-55023

GEB [GEB OR]

The FLAG field of the local coordinate system created by GEB_ORs with
SectionForces representation is now able to be controlled directly by the GEB_OR
entity, via the new "coord_flag" field of the GEB_OR card.

ANSA-71250

ICFD ICFD MODEL


ICFD MAT
ICFD DATABASE

Additional ICFD keywords are now supported:


*ICFD_DATABASE_DRAG
*ICFD_DATABASE_FLUX
*ICFD_DATABASE_AVERAGE
*ICFD_DATABASE_HTC
*ICFD_MAT
*ICFD_MODEL_POROUS
*ICFD_MODEL_NONNEWT

ICFD menu may be activated after enabling the new Settings> Decks [Enable
LS_DYNA ICFD] setting.

42316, ANSA-26479

A new ICFD group is now introduced. It may be activated after enabling the new
Settings> Decks [Enable LS_DYNA ICFD] setting.

ANSA-77249

BETA CAE Systems 36


ANSA v19.1.0 Release Notes What’s New

PAM-CRASH
Input PAM-CRASH solver python module affecting PYVAR epyDisplayErrorMessage,
epyValueDim, epySolverVersion, is now supported.

BCS-2545

Checks xLINKs [PLINKs]

The check now reports an error, when the Projection Node IDNOD is shared by an
other mesh element or a kinematic constraint or a boundary condition.

ANSA-75645

Settings Settings> Decks [PAM-CRASH: Output PENTAs as SOLIDs]

New option enables the writing of the PENTA6 elements as SOLID during output.

ANSA-64959

ELEMENT SAFE [BAGIN / ]


ENT
"Local" and "Gas" tabs are now available in "FPM Activation" tab that correspond to
LOCAL_H and FPM_GASDYN subkeywords correspondingly.
Furthermore, FPM_NOSLIP option is now supported and can be found in "Gas" tab.

BCS-1913

AUXILIARIES RES.MAP

The preview functionality can be used from IMPORT entity card.


M01 files with multiple parts are now supported.

ANSA-74843

The '3 Points Transformation' is now supported in Align Mesh tab, allowing keyword
output for solver mapping.

BCS-1966

Abaqus
General RADIATION CAVITY

PARALLEL DECOMPOSITION parameter of *CAVITY DEFINITION keyword is


now supported.

ANSA-76710

Input When reading a *COUPLING with REF NODE = [NSET], new COUPLINGs will be
created with masters the nodes contained in NSET.

BCS-811

BETA CAE Systems 37


ANSA v19.1.0 Release Notes What’s New

Input When ELSET and NSET with the same name are input, a warning is written in the
ANSA_Input.log.

63031, BCS-1130

Output Unused sets of solidfacets/edges are now written as *SURFACE during output.

58119, BCS-1122

Settings ANSA defaults> INPUT PARAMETERS> ABAQUS input options [Read


Unreferenced Distributions]

A new flag has been added at ANSA defaults, in order to control the application of
unreferenced Abaqus Distributions.

ANSA-80198

Materials ANISOTROPIC HYPERELASTIC material type is now supported.

ANSA-68966

ELEMENTs SHELL [By Thick Shell]

When converting continuum shells to shells and having the option: "Delete
C.Shells elements" active, the IDs of new generated continuum shells are copied
from the initial shells.

BCS-2023

CONSTRAINTs COUPLING [Set]

The optional parameter COUPLING=STRUCTURAL for *DISTRIBUTING coupling


is now supported.

BCS-812

AUXILIARIES CONTACT FORMULATION

Support of the *CONTACT FORMULATION with all available types.

ANSA-61486

CONTACT [CONTACT]

The MIDFACE NODES option is now available in *CONTACT PAIR when


TYPE_tie_coefficients is set to SURFACE TO SURFACE.

BCS-2146

STEP

RESIDUAL MODES parameter is now supported for ABAQUS deck, related to


*FREQUENCY keyword, under Parameters button.

BCS-1258

BETA CAE Systems 38


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES The option MASS for NORMALIZATION parameter of *FREQUENCY analysis


type is now supported.

BCS-1581

STEP [New [Loadcase]]

*LOAD CASE keyword under perturbation step is now supported through the 'New
*LOAD CASE' option of the context menu of a STEP.

61554, ANSA-39626

LC/A Point connectivity options are no longer available for CONTACT, ELEMENT
and ENERGY Output Requests.

ANSA-80657

*CONTACT FORMULATION keyword is now supported.

BCS-1749, 57150, ANSA-36519, BCS-1657

Fringe EL.STRESS MENU

Line elements are now colored according to the Stress initial condition that is
assigned to them.

ANSA-81678

Scripting New python methods for *LOAD CASE in Loadcase.abaqus class are now
supported:
Loadcase.abaqus.new_loadcase()
Loadcase.abaqus.delete_loadcase()
Loadcase.abaqus.get_loadcases()

ANSA-76049

RADIOSS
Input Character limit for #include keyword has been increased to 500.

BCS-999

Materials /MAT/LAW72 (HILL_MMC) is now supported.

BCS-1907

TIME A /TH/RWALL is now automatically created when a related entity is created.


HISTORY
ANSA-77165

A /TH/INTER is now automatically created when a related entity is created.

ANSA-77164

BETA CAE Systems 39


ANSA v19.1.0 Release Notes What’s New

TIME A /TH/RBODY is now automatically created when a related entity is created.


HISTORY ANSA-77163

AUXILIARIES CONTROL

Multiple entities are now supported.

ANSA-73746

FAIL

CHANG method has been added, describing the Chang failure model.

BCS-2099

INTERFC

IDEL=1000 for /INTER/TYPE7 keyword is now supported.

BCS-976

For RADIOSS 2017 and /INTER/TYPE19, the value 3 in Igap field is now
supported.

BCS-1615

For the below, additional field values are now supported.


/INTER/TYPE7
Idel: 1000
Igap: 1000
Ibag: 2
Inacti:1000
Iform: 0

/INTER/TYPE11
Idel: 3, 1000
iform: 0
inacti: 1000

/INTER/TYPE19
Igap: 1000
Ibag: 2
Idel: 3, 1000
Inacti: 1000
Iform: 0

ANSA-80043

BETA CAE Systems 40


ANSA v19.1.0 Release Notes What’s New

AUXILIARIES LAMINATE

The initialization of orthotropy direction on each element (/INISHE/ORTH_LOC) for


/PROP/TYPE11, /PROP/TYPE16, /PROP/TYPE17 and /PROP/TYPE51 is now
supported.

Note that Input of /PROP/TYPE11 and /PROP/TYPE16 with such information will
be listed under the PROPERTY LAMINATE list in the Database browser.

Also, Output for all properties is for angle unit in degrees (Iunit=1).

ANSA-54195

MONVOL

For RADIOSS 2017, the Finite volume meshing parameter fields of kmesh and
Tswitch are now supported.

BCS-2480

SAFETY Seatbelt

Fields for 'Load time' and connecting SPRINGs of type 4 have been added within
'Properties...' pop-up window.

ANSA-76727

A "Properties..." button that pops up a window for easier assignment of all


respective 1D element properties has been added.

ANSA-62807

ANSYS
General COMBI250

New element type is now supported for spring/ damper elements.

ANSA-77977

Input/ output of Hypermesh comments are now supported.

ANSA-59232

Output Shell elements that use a (non layered) property, the material id that this property
refer will not be written during output in shell section definition (SECDATA), if this
material is undefined.

BCS-1884

The Option "Orient Beam Using 3rd Node" has been added also in the default
settings. Thus, the user-defined default option is now able to be saved in the
ANSA.defaults file.

BCS-2633

BETA CAE Systems 41


ANSA v19.1.0 Release Notes What’s New

Properties The SURF153 element type is now supported.

BCS-469

AUXILIARIES CONTACT [Assistant]

It is now possible for Contact Type = PILOT NODE to select geometry POINT entity
for the definition of the Pilot Node and automatically the respective NODE entity will
be created

BCS-1745

PERMAS
AUXILIARIES RES.MAP

Mapping of DISLOADN TEMP is now supported.

ANSA-76478

Drawing EL TEMP MENU


Styles
Initial temperature distribution (INIVAL TEMP) can now be visualized as fringe plot.
A respective pull down is provided in order to select initial (INIT TEMP) or applied
temperature (LOAD TEMP).

ANSA-77785

OpenFOAM
Input/ Output "Binary I/O with 64 bit integers" flag has been added.

ANSA-81240

TAITherm
General ANSA now interfaces with MSC Material Center for Taitherm solver materials.

ANSA-80181

Properties MULTI-LAYER PART

Multilayer parts with 2 layers are now supported.

ANSA-61711

BETA CAE Systems 42


ANSA v19.1.0 Release Notes What’s New

ELEMENTs INFO

Increase of the upper limit of ids numbering for grids, shells and polygons has been
implemented.

BCS-2535

OPTISTRUCT
General PBUSH

In the Ki (Nominal stiffness values) fields, "RIGID" can now be set as acceptable
value.

ANSA-77136

Properties PBUSH

In the Ki (Nominal stiffness values) fields, "RIGID" can now be set as acceptable
value.

ANSA-55752

DM Optistruct file type is now supported for saving of parts/subsystems in the DM.

ANSA-76756

CROSS SECTION
Output The Cross Section Tool can now output PBxSECT properties from cross sections
that contain pasted cross section curves.

ANSA-81200

Connections Collapse Paste

New function Collapse, converts Pasted cross section curves to a single curve,
combining their properties to a new one.

ANSA-81200

Scripting base.CrossSectionAutoSpotAll

The AutoSpot [All] function can run through script. A specific value is returned,
indicating the successful creation of cross spots.

ANSA-80718

BETA CAE Systems 43


ANSA v19.1.0 Release Notes What’s New

Scripting base.GetCrossSpotConnectedCurves()

New function has been added that takes as input a cross spot and returns a list of the
connected cross curves.

ANSA-80945

KINETICS
Input/ Output MotionSolve solver files (.xml) are now supported.

38169, ANSA-23646

Bodies Flex

New column has been added in the Modal ICs tab of the Flex Properties window that
indicates which particular modes have the biggest contribution on the dynamic
behaviour of a flex body.

ANSA-70113

ADAMS Input has been enhanced and the definition of flex bodies through matrices
(.mtx files) is now supported.

ANSA-67777

Tire

Improved interface for tire bodies now allows definition of multiple tires
simultaneously.

ANSA-77601

Auxiliaries Flex [Builder]

FE entities that are incompatible to Epilysis/Nastran solution are now identified and
deactivated by default.

ANSA-79789

Flex Builder's output will now allow writing out NASTRAN files with ANSA comments
by default.

ANSA-79327

Mech

The combination of connectors Cartesian-Axial-Cartesian of ABAQUS are now


succesfully converted to a combination of spherical-slider-spherical joints of Kinetics.

ANSA-76697

BETA CAE Systems 44


ANSA v19.1.0 Release Notes What’s New

Auxiliaries Model Info

The new graphical representation of models can now show the connectivity of bodies
including their connectors as a schematic diagram.

ANSA-80629

Simulation Configurator

The Step and Total values can now be assigned with an A_PARAMETER or
KIN_DESIGN_VARIABLE entity through "Articulate> By Actuator Joint" of Kinetic
Configurations' context menu or through "Move Joint" of Kinetic Joints' context menu.

ANSA-73286

Results

Joint Constraints Velocity Errors results are now supported.

ANSA-76897

New Quick Plot button added within Results Viewer; once activated, it will clear
existing plots and add a new one as long as a result characteristic is selected from
the respective list. When this option is enabled, the Add and Remove buttons
become disabled.

ANSA-78653

Simulator

New option has been added under General tab of Simulator settings window,
allowing to choose the Cosin HTire solver to be used when running simulations with
tires of Pacejka formulation.

ANSA-77570

Scripting kinetics.GetArticulationHistoryFromConfig()

New function has been added to obtain the configurations' articulation history.

ANSA-76019

MORPH
Controls Deform Map

Line Connections are now able to be selected as entities to be deformed.

ANSA-79444

New option in DEF MAP function, called 'Save as DVGrids', is now available to allow
the use of current deformations in consequent applications.

ANSA-79423

BETA CAE Systems 45


ANSA v19.1.0 Release Notes What’s New

HEXA BLOCK
Boxes Convert

Option "Preserve loaded elements" has been introduced, so that conversion of


Hexablocks to Morph Boxes maintains the "loaded" status of the Elements with the
relevant boxes. Box faces may need to be adjusted, to address any, so called,
"frozen" faces.

ANSA-77560

Checks Box Quality

Function that checks quality of Boxes has been added.

ANSA-49111

OPTIMIZATION
Optimization DataBase Save action, performed whilst the Optimisation tool is open, will now
Tool consider and preserve the current condition of the DOE matrix.

ANSA-81347

DOE setup

The experiment folder prefix can now be user defined.

ANSA-61316

Task Manager
General Shell script input, apart from plain executables, in now also supported in the
"Executable" field of the optimization task's run options.

ANSA-79998

Scripting
base.AddToAnnotation()

Multiple entities can now be added to an Annotation.

BCS-923

base.CalculateHardeningParameters()

It is now able to calculate hardening parameters (K and n) from stress/strain data through scripting.

BCS-2283

BETA CAE Systems 46


ANSA v19.1.0 Release Notes What’s New

base.CollectEntities()

Function has been enhanced to enable node collection from a CONS.

ANSA-81422

base.SetEntityCardValues()

A debug option in the form of an argument has been added in this function that returns a tuple with an
integer that values 0 on success or non zero on error, as well as a dictionary that holds any
errors/warnings found.

BCS-2819

base.TranslatePart()
base.TransformPart()
base.SymmetryPart()
base.ScalePart()
base.RotatePart()
base.MirrorPartPoint()
base.MirrorPartPlane()
base.MirrorPartAxis()
base.GeoTranslate()
base.GeoTransform()
base.GeoSymmetry()
base.GeoScale()
base.GeoRotate()
base.GeoMirrorPoint()
base.GeoMirrorPlane()
base.GeoMirrorAxis()

The "group_offset" argument is now enhanced with the "Current Part" and "Existing Part" options and
the "pid_offset" with the "Current Property" option.

ANSA-78720

base.MeanFieldHomogenizationMakeMaterial()
base.MeanFieldHomogenization()

New script functions have been added to perform homogenization of multiphase materials and create
appropriate material entity for each deck.

ANSA-82276

base.MergeAnsaModels()

A new function is now available to support the merging of two ANSA Models already loaded in the
ANSA session.

BCS-333

BETA CAE Systems 47


ANSA v19.1.0 Release Notes What’s New

guitk.BCLineEditSetEditingFinishedFunction

A new function is now available, which enables a callback function definition, which will be triggered
when editing of a BCLineEdit is finished.
Editing of a BCLineEdit is considered as finished when pressing the Return or Enter key, or when the
BCLineEdit loses focus.

ANSA-79464

Scripts Collection
FemsiteMaxElemsPerNode.py

A new check has been added for NASTRAN deck to check the maximum number of elements that
connect to a single node, for a FEMSITE analysis. The check flags any node that violates the user-
defined max number of elements criterion.

BCS-2046

BETA CAE Systems 48


ANSA v19.1.0 Release Notes Known problems resolved

3. Known problems resolved in v19.1.0


General
General Developer License

In case of an unexpected termination of ANSA, the current Database could not be


saved.

BCS-2041

Nodes would not be able to be picked through transparent unmeshed geometry for
ANSA v17, v18 and v19.0.x.

ANSA-71228, ANSA-62861

Entity Card fields with values more than 9 digits would not be shown properly.

BCS-2059

Databases that contained "Task Item>Common Model>Checks/Fixes>Geometry"


in the Task Manager and saved with version prior to v1810 would not be able to be
read from ANSA v181x, v1900, v1901. In addition, databases saved as v17 from
v181x series could not be read from v17 series.

BCS-2392

Pick mode would not be available for Parts in Database Browser through their
assigned connection entities.
The same also applied to base.PickEntities() script function, unable to identify
ANSAPARTs, where the connection entities were assigned to.

BCS-628

Input MEDINA

Boundary sets containing Solid faces would not be labeled as Surface Sets for
ABAQUS and PERMAS.

ANSA-78610

Incorrect expansion of range sets when deactivating the flag 'Keep MEDINA Range
Sets'.

ANSA-77273

Tools Settings [Settings> Decks]

Entities created from Seatbelt Tool (Contacts, Pretensions, Retractors, Sliprings


and Mat-Seatbelt) would not respect 'Create New IDs' flag.

BCS-1531

BETA CAE Systems 49


ANSA v19.1.0 Release Notes Known problems resolved

Utilities Quality Criteria> Presentation Parameters [Nodes visibility]

When "Show only used with Name" and "Show only used with Field 10" flags were
active, application of "Show"/"Show Only" context menu option on Includes
(through Lists> Includes) would result in erroneous display of all grids, ignoring the
activated flags.

58577, ANSA-37506

Transform [Copy]

Unexpected termination would occur when solids used by


*INITIAL_STRESS_SOLID (LS-DYNA) where copied.

BCS-1036

Lists Sets [Modify Contents]

When modifying the content of a SET, the initial entity type selection would not be
determined by the SET content.

ANSA-76414

Models

Double click on a Model's Visible column would not Show Only the selected model.

BCS-1961

Commu- Idle User Timeout


nication with
License "Retry" button in the warning window would not work.
Manager
BCS-1505

Scripting base.TransformPart()

PID auto offset option would not work, when applying the function.

ANSA-52698

CAD Import/ Export


General Translators STEP

Translation of specific STEP file would create faces in wrong position.

BCS-866

Import Translators NX

When opening specific NX files with the use of the NXOpen library no geometry
would be transferred in ANSA.

ANSA-79445

BETA CAE Systems 50


ANSA v19.1.0 Release Notes Known problems resolved

General Translators CATIA

Several CATIA attributes would not be transferred, when opening a 3dxml file in
ANSA.

ANSA-64228

The location path of points and curves under geometric sets would not be
transferred to the Comment field of their cards in ANSA, when opening a 3dxml file
with the "Read features" option enabled.

ANSA-54794

CAD to ANSA Translators


General Parallel worker processes could remain alive, in case the main ANSA was terminated
before finish.

BCS-2345

Input Translators Pro/ENGINEER

After the CAD translation, the CAD attributes of outermost entities would be empty.

ANSA-61008

Translators STEP

Toroidal surfaces of an imported *.stp file would have negative radius causing
missing faces.

BCS-1075

Corrupted database with toroidal surfaces would be created during input, which could
lead to erroneous behavior or unexpected termination during Output.

ANSA-80589

GUI
General Occasionally while in a function, the operations to rotate and zoom the model would
not be available.

BCS-1014

Floating windows would be left in a disconnected screen.

BCS-1651

The working window would sometimes become inactive (no focus), after a function
was finished.

ANSA-68298

BETA CAE Systems 51


ANSA v19.1.0 Release Notes Known problems resolved

Tools Settings [Compare xml files]

Unexpected termination could occur when using the filter to search for xml entries.

BCS-1559

Model Browser
General When selecting a part or group from GL area with 'Identify' while being in 'Icon' view
mode it would switch to 'tree' view mode.

ANSA-52869, 64368, ANSA-41664

Slow opening of Groups in Model Browser would occur when viewed in Icon mode.

63793, ANSA-41234

Adding card fields as columns would not be able in ANSA v19.

ANSA-76404

The entity cards of model browser entities (e.g. Subsystems, Simulation Models)
would be missing all the secondary attributes.

ANSA-62362

An Assembly Point created during the realization of a Bolt that belongs to a


Subsystem would be erroneously placed in the Out of Subsystems container.

ANSA-80357

Output Duplicate connector elements would be written out in a simulation run. The problem
would occur if connector elements were created by ANSA Connector Entities that
were loaded in the ANSA session and were assigned to the Simulation Model, while
the same connecting elements already existed within connecting subsystems of this
Simulation Model.

ANSA-79087

Show/Show only actions would change the hidden status of entities.

ANSA-79617

Parts/ Groups Show/ Show only actions on Parts/ Groups would change the hidden status of
entities.

ANSA-77421

BETA CAE Systems 52


ANSA v19.1.0 Release Notes Known problems resolved

Subsystems Graph view

When a slot was selected in Subsystem's Graph view the full Subsystem contents
would appear in the Contents tab. Now, only the corresponding Assembly Points
appear in Contents tab.

ANSA-77577

The graph view would not be correct in cases where a connecting Subsystem
connected more than two Subsystems.

ANSA-77576

When a Subsystem created from disk was loaded its content would be erroneously
added to the GEOMETRY_OUT_OF_SUBSYSTEMS container.

ANSA-73790, ANSA-60325

The GEOMETRY_OUT_OF_SUBSYSTEMS container would remain in the


Subsystems tab, even when all the Subsystems of the model were deleted.

ANSA-56663

New empty Parts would be created, when a Subsystem containing multi-instantiated


Parts was downloaded from DM.

ANSA-73789

If a parameter was used without being defined while saving an ANSA file in DM an
undefined *PARAMETER would be created, having a default value. This
*PARAMETER would not be written out during output.

BCS-1851

Simulation Outputting a Simulation Run for Abaqus deck, the STEP keywords would not be
Runs written at the end of the output file.

ANSA-71337

Loadcase Actions [Copy/Paste]

Unexpected termination would occur by copying and pasting a Loadcase Assistant.

ANSA-79648

DM Update Status

Loadcases would not show the correct DM Update Status.

ANSA-75795

Configurations When a configuration was activated and entities related to deactivated configurations
were detected, it was possible to select and activate another Configuration without
finalizing the handling of such entities.

ANSA-64150

BETA CAE Systems 53


ANSA v19.1.0 Release Notes Known problems resolved

Configurations Upon the activation of the configuration, the connections referencing a PID used by
an inactive Part would be errouneously deactivated.

ANSA-69886

Contents Check Missing & Misplaced

The check function can now also report shells and solids that are FE-representations
of connections and are initially placed under a different Model Browser Container
than their connection entity.

ANSA-80056

DM Replace

Internal GEBs and connectors were not deleted during change representation.

BCS-1660

When the attributes of the Simulation Model were updated during "Replace" or
"Replace metadata" from the DM tab Loadcases associated with these Simulation
Models (through Simulation Runs) would not get updated, although they had
attributes that, according to the dm_structure.xml, originate from Simulation Model
attributes via rules.

ANSA-77181

Upon the replacement of a part, unrealized connections would be realized, while


connections with FE-Representation and Status not 'ok' would not be re-applied.

ANSA-65160

During Part replacement, affected connections, which were not previously applied,
would be realized.

ANSA-82092

Function would be available only for the master part, in case of multi-instancies.

BCS-1662

The available options of the DM drop down menu would not be synchronized with the
available options in the context menu, in case of selecting adapter items (eg. a
Subsystem under a Simulation Model).

ANSA-73172

Application of 'Change Representation' or 'Reload' function on a part, which had


been saved in DM along with its Subsystem, would lead to more than one
Subsystem in Model Browser.

ANSA-78086

Identify When the model was on Icon view the Identify action would turn the view mode to list
view.

ANSA-55352

BETA CAE Systems 54


ANSA v19.1.0 Release Notes Known problems resolved

Scripting base.ReplacePart()

Upon the replacement of parts through script, the PIDs would not be updated
properly.

ANSA-67726

Compare
General Unexpected termination would occur, when trying to paste the path of the files to
compare in the Wizard.

BCS-2409

Upon the comparison of two single-part models their parts would not be matched.

ANSA-63154

Wizard Back/ Next

Models would be read anew in comparison scenario, when going one step back and
then forward again.

BCS-1595

Data Management
General When a Simulation Model was loaded from DM its original contents would remain in
the database.

ANSA-78748

Input model definition [PLMXML Tree]

META viewer in Product Tree Editor would show the selected part/ group with
distorted geometry, in case of 3dxml reference files.

BCS-2308

Input Input Deck File of very large path would fail, when connected to a web based DM
path.

ANSA-81027

Groups Save in DM

Saving a Group in DM would not save its Shells and Grids.

ANSA-73495

BETA CAE Systems 55


ANSA v19.1.0 Release Notes Known problems resolved

Subsystems When a Subsystem was loaded from DM, it would automatically pull Materials and
Properties used by its contents, even if these Materials and Properties were assigned
to a different model container.

ANSA-81205

DM Browser Check DM Updates

Check DM Updates for Parts would not be functional, when connected to SPDRM.

ANSA-69147

Unexpected termination would occur when opening the DM Browser after saving in
DM an Include from the Includes list.

BCS-1612

When a Subsystem was saved in DM with ANSA file type the quality of the image
preview displayed in the DM browser would be low.

BCS-1812

The comment of a subsystem of any solver type would not be saved in DM.

BCS-1012

Upon the display of parts with many attributes in the DM Browser window, a
significant delay would occur.

ANSA-49568

Erroneous initial sorting of items would occur in flat view mode.

ANSA-78668

Results files from DM would not be properly deleted.

ANSA-67920

Set DM Paths Add

It would be possible to type the name of a path for a non-existing folder.

ANSA-64517

Scripting base.AddFileInDM()

The function would fail to add an ANSA database for Parts in DM, when the "File
Type" property value was set equal to "ANSA".

BCS-1456

dm.GetLibraryItemTypes()

New script function has been added to collect all available types of rich library items
found in the data model.

ANSA-80252

BETA CAE Systems 56


ANSA v19.1.0 Release Notes Known problems resolved

Connections & Assembly


General Connection Status would be reset whenever one of its endpoints was modified.
Specifically, upon modification of CURVE card values, such as Name or Comment,
for example, the Connection Status would change from OK to blank.
The same behavior would also occur via script.

52022, ANSA-32867

Loading the interface representations of Subsystems that contained connections


defined on PIDs would lead to these PIDs not be associated with the Subsystems
after load.

BCS-1804

Parameter names and labels had several typo errors.


For example, <Zone width> vs. <Zone Width>, as well as varying number of spaces
in cases, such as <SheetToe Zone2 Width Calc Method>, which would lead to
database backward incompatibility.

BCS-2831

File Output connections [XML]

ANSA would not always write the same order and grouping of connections, when
exporting the same XML file.

BCS-1377

Checks Connections [Check double connections> By absolute distance]

Connections would be detected as double, although their distance was greater than
the defined "spot distance" value.

ANSA-69185

Spotwelds/ A connection that had the 'Avoid Feature Lines' FE representation setting disabled
Spotweld would unexpectedly fail to realize, in case it was in the proximity of a geometrical
Lines/ perimeter.
GumDrops
BCS-1695

Spotwelds Spotweld would loose its status, when the nodes of the FE-Representation were
moved.

BCS-1738

The realization of Spotweld connections that lay on PID bounds or FE perimeters


would fail.

BCS-3005

GEBs Randomly erroneous results would occur in user defined area of GEBs, when
creating multiple user defined areas on second order elements.

ANSA-82863

BETA CAE Systems 57


ANSA v19.1.0 Release Notes Known problems resolved

Seamwelds Closed seamwelds with FE Rep Type RBE2 and "Force Node To Node" option active
would create duplicate RBE2 elements, causing dependency errors.

ANSA-79994

Nastran Dependency error would occur, when realizing Seam-weld lines.

53963, ANSA-34222

When manipulating the mesh of connectivity parts the "OK" connection status would
be lost.

23533, ANSA-13951

Connectors A connector would unexpectedly fail to realize, in case of 'Constrained Rigid Body'
representation and 'Node' search patterns.

ANSA-77143

A Connector would unexpectedly fail to realize in case of 'Rigid' representation and


'Passthrough' search pattern.

ANSA-80018

When a Connector was realized on Assembly Points, which were assigned 'Output
with Subsystems' : 'No', the Ids of the central nodes of the interface elements would
not be maintained.

ANSA-77801

Applying Connectors with search method "Node" or "NodeOnDirection" and search


nodes option "skin" would take excessive time.

ANSA-80613

A POINTs/ LC Numbering Rule of Subsystem would be forced, even if entity had special numbering
POINTs rule.
Now, any numbering rule defined in the edit card of an A_POINT/LC_POINT prevails
over any numbering rule of the A_POINT/LC_POINT container. This means that even
if the special numbering rule for the node marked by an A_POINT/LC_POINT sets an
id that is out of the target numbering range ot the subsystem where this
A_POINT/LC_POINT belongs to, the special id will finally be respected.

ANSA-79846

Assembly The numbering rules inside the Assembly point entity card would not be applied to
Points the interface node, in case that the interface node already existed and the Assembly
point created interface elements.

ANSA-77589

The specified rigid patch material Id, in case of an Assembly Point with 'Rigid Patch'
interface, would not be saved in the ansa database.

ANSA-76537

BETA CAE Systems 58


ANSA v19.1.0 Release Notes Known problems resolved

Interface Sets The label of sets marked as interface sets would not be exported in the ANSA
comments and, thus, not maintained after output/ input of Subsystems.

ANSA-68103

Connection Functions [Center]


Manager
Application of function would fail in case of same part connectivity.

BCS-1408

Realize

When Settings> Decks> Entities Reference Library and Settings> Connections> FE


Rep. Ref. Library were set as below:

upon manual creation of Connection and realization one by one CONTACTs would
be created redundantly and lead to the creation of double/triple CONTACTs, which
was an error in LS-DYNA.

Now, upon Realize of a Connection, an already existing CONTACT is used, if


CONTACT from Reference Library has offset, instead of creating a new one.

BCS-2476

Single contact option in FE Rep. Settings would not merge existing contacts that
were created through Convert [FE to Connection Points].

BCS-1783

Status of applied connection entities would be lost, after updating property card of
adjacent elements.

ANSA-68306

The Segments written out when outputting a model with Hexa-Contact connections in
PAMCRASH deck would not belong to the connection after re-inputting the file.
Therefore, applying Erase FE these segments would erroneously remain in the
database.

33288, ANSA-20487

BETA CAE Systems 59


ANSA v19.1.0 Release Notes Known problems resolved

Template Performance issues would occur, when opening databases with many connection
templates and connection rules.

ANSA-82144

Define Holes
Connection
In case of blind Tubes, the generated Bolts would be assigned an erroneous
"User/Bolt Hole Type" attribute value.

BCS-1997

Convert FE to Adh Faces

Solids with big ratio height to width would be converted to Adhesive Faces with
erroneous orientation.

ANSA-79777

FE to Adhesive

Realizing adhesives of COHESIVE-CONTACT representation after applying the


function would fail due to small detected search distance.

BCS-1753

When HEXA-CONTACT representations were converted to Adhesive line


connectivity information would be erroneously calculated.

BCS-1757

Segment elements, laying on solid facets of FE Representations with Solids, would


be ignored by the Convert function.

BCS-940

FE to Cnctn Pts

Erroneous FE Rep. Type would be detected while converting the FE representation


of SPIDER2 connections to connection points.
Now the correct FE Rep. Type is assigned to the generated connections.

ANSA-79068

Realizing connection after applying the function would create new contacts instead of
using the existing ones.

BCS-1081

Function would erroneously identify as connectivity part Adhesives that existed


between the flanges and shared common nodes with the body of the connection.

BCS-1346

BETA CAE Systems 60


ANSA v19.1.0 Release Notes Known problems resolved

Scripting connections.FindDuplicateConnections()

The function would not return correct results, in accordance with the distance
argument provided.

BCS-2688

FE Representations
BEAM BOLT The thickness of the Shells of the Bolt head and nut would not be considered during
realization on solid parts. Therefore, realization on solid parts would result in property
thickness penetration.

BCS-1990

Upon realization of a bolt connection entity on tubes that consist of geometry mesh,
the specified Tube Feature Line Angle Limit value would be ignored.

64681, ANSA-73081

BOLT NULL The interface elements of the bolt were not attached to the null shells. They would
SHELL erroneously be attached on the shells of the connected parts.

ANSA-78889

Upon realization, the nodes of the generated Null Shell elements would be placed in
the out of Subsystems container.

ANSA-81972

BOLT ON Upon realization, a BOLT ON SOLID would fail to attach to the chamfered segment
SOLID of a solid tube, although the specified "Tube Feature Line Angle Limit" was greater
than the angle of the chamfer.

BCS-2090

BETA CAE Systems 61


ANSA v19.1.0 Release Notes Known problems resolved

Y-JOINT- Unexpected termination would occur when the Connection Manager was re-launched
SHELL/ Y- after a modification of one of the following seamline FE Representation settings:
JOINT- -Zone width
FEMFAT/ T- -Offset row width
JOINT- -Weld thickness
SHELL- -Weld width
CLOSED/ T-
JOINT-
SHELL/
OVERLAP-
SHELL-
CLOSED/
OVERLAP-
SHELL/
LASER-
WELD-
SHELL-
CLOSED/
LASER-
WELD-
SHELL/
LASER-
WELD-
FEMFAT/
EDGE-WELD-
SHELL/
EDGE-WELD-
FEMDAT/
CRIMP-
WELD-
SHELL/
CRIMP-
WELD-
FEMFAT ANSA-81937

CRIMP- Upon realization, the specified value for the width of the offside 2nd zone on the
WELD-SHELL secondary sheet would not be respected.

ANSA-79703

Y-JOINT- A combination of zero width and 'root shells' equal to 'Primary Row' would lead to
SHELL/ unexpected realization failure.
OVERLAP-
SHELL/
CRIMP-
WELD-SHELL ANSA-82305

BETA CAE Systems 62


ANSA v19.1.0 Release Notes Known problems resolved

Y-JOINT- Occasionally, when "Step Length" option was left blank and [Loose ends] not active,
SHELL/ Y- the average element length would be miscalculated.
JOINT-
FEMFAT/ T-
JOINT-
SHELL-
DOUBLE-
CLOSED/ T-
JOINT-
SHELL-
CLOSED/
OVERLAP-
SHELL-
CLOSED/
OVERLAP-
SHELL/
OVERLAP-
FEMFAT/
EDGE-WELD-
SHELL/
EDGE-WELD-
FEMFAT BCS-1955

LASER- The seamline FE Representation settings would not be exported correctly during
WELD- File> Output, in case that the 'SheetToe Zone2 Width' field was blank.
SHELL/ As a result, the seamline FE Representation settings would not be read during File>
EDGE-WELD- Input.
SHELL
ANSA-79831

LASER- Upon realization, the actual width of the weld would be twice the specified value in
WELD- the 'Width' field of the FE Representation settings.
SHELL-
CLOSED ANSA-79723

PENTA- Upon realization, a seamline of this FE rep. would erroneously generate FE


CONTACT- Perimeters along the projection of the solid elements.
ON-SOLIDS
ANSA-82321

RBE3-SHEL- Erroneous weld direction would appear in small welds (up to 3 edges covered feature
RBE3 line).

ANSA-80227

Erroneous realization would possibly occur in BUTT-WELD-like weldings (feature line


to feature line on opposing parallel sheets).

ANSA-80237

BETA CAE Systems 63


ANSA v19.1.0 Release Notes Known problems resolved

SOLID BOLT/ Tube Feature Line Angle Limit


RADIOSS
BOLT/ Upon realization of a bolt connection entity on tubes that consist of geometry mesh,
HYBRID the specified Tube Feature Line Angle Limit value would be ignored.
BOLT/ BOLT
ON SOLID/
BEAM BOLT BCS-2026

SOLID-WELD Unexpected termination would occur when realization (with errors) was performed in
no GUI mode.

ANSA-78103

Y-JOINT- 'Realize' would create multiple materials.


FEMFAT
ANSA-63967

Y-JOINT- Erroneous treatment of Y-JOINT with height and "keep adjusted shells" option would
SHELL lead to realization failure. The option is now supported for any height value.

ANSA-80063

Topo
Faces Flange [Compatible]

Significant improvements of the used algorithm have been implemented to increase


its robustness.

ANSA-67555

Mid.Surface [Align Manager]

Perimeters would not be correctly aligned at the edge of a rib.

BCS-1635

Mid.Surface [Casting]

Perimeters on thickness jump of tailor blank parts would be slightly misplaced.

BCS-898

When 'Connect weldings with thickness ratio' option was activated perimeters on PID
boundaries would be erroneously joined.

ANSA-82662

Auxiliaries Cross Sections [Multicut]

The orientation of generated PBEAML_BOX properties, created with the "Section


Type" = "Equivalent Box" option, would not be in accordance with the orientation of
the cross sections generated from multicut.

ANSA-64208

BETA CAE Systems 64


ANSA v19.1.0 Release Notes Known problems resolved

Focus Not

Using the function with PID Region at Topo module could lead to unexpected
termination if a Cross Hatch was selected.

ANSA-77474

Shell Mesh
Tools Settings [ANSA defaults]

ANSA would lead to unexpected termination, if ANSA defaults file was loaded with
the keyword entities_reference_library_path.

ANSA-79104

Utilities Quality Criteria [Shells>growth ratio]

In certain cases, criterion would give different number of off elements each time it
was used.

ANSA-79674

Hot Points Insert

Function would not work with Reconstruct option, when "Freeze>Perimeters" flag
was enabled in Mesh Parameters. The same has been fixed for Hot Points>Delete.

ANSA-76685

Mesh STL
Generation
Extreme cases where quads would be generated when element type was set to Tria.

BCS-2000

Shell Mesh Improve [Reconstruct]

Applying the function in ANSA v19 would move the grids away from the perimeter,
exceeding the maximum distance limits set in the Mesh Parameters.

BCS-2585

If the reconstructed area had entities that need mapping after reconstruct (forces,
pressures etc.) results mapper would run for temperatures as well.

BCS-2061

Elements Vol.Mesh

Function on second order solids would produce first order shells, in case of ANSYS
properties.

55531, ANSA-35334

BETA CAE Systems 65


ANSA v19.1.0 Release Notes Known problems resolved

Scripting base.CollectEntities()

Wrong shell elements would be returned, when a geometrical feature was used as a
container.

ANSA-80720

mesh.UnmeshedMacros()

Occassionally, when the function was finished some CONs would remain highlighted,
followed by unexpected termination when another function was called after that.

64541, ANSA-41784

Volume Mesh
Utilities Isolate [Short Path [Leaks]]

Randomly, the function would lead to unexpected termination.

BCS-2377

Unstructured Hexa Interior


Mesh
Specific cases where the function would not generate HexaInterior mesh due to
"kernel 41" error.

BCS-2522

Tetra Rapid
Tetra FEM

The number of violating elements and elements with negative volume has been
significantly reduced. This applies on 2nd order elements.

ANSA-76434

Structured Extrude
Mesh
Applying offset on both sides of a shell mesh would erroneously produce duplicated
elements.

BCS-2070

BETA CAE Systems 66


ANSA v19.1.0 Release Notes Known problems resolved

Structured Layers
Mesh
Unexpected termination would occur, when layers area was defined from empty
Properties or Parts.
(Accessible also through MESH> Volumes> Layers [Create]).

ANSA-81181

In some cases, after connection of layers to the symmetry plane, over-refinement


regions would be created.
(Accessible also through MESH> Volumes> Layers [Create]).

ANSA-80726

Layers growing from different areas with different number of absolute height and
additional outer layers in aspect mode would not be generated with correct heights.
(Accessible also through MESH> Volumes> Layers [Create]).

ANSA-79843

Last aspect ratio of additional outer layers would be underestimated. Now, in order to
achieve the equivalent result, the default value has been changed from 0.6 to 0.45.
(Accessible also through MESH> Volumes> Layers [Create]).

65137, ANSA-42194

Auto-connect to map quad mesh would be applied regardless of whether the


underlying mesh was a valid map quad mesh. Now, in case of a non-valid quad
mesh, layers connect by imprinting a new mesh.
(Accessible also through MESH> Volumes> Layers [Create]).

30220, ANSA-18448

Improve Smooth

Solid elements PID bounds would not be respected when applying the function.

BCS-2217

Scripting mesh.CreateShellsOnSolidsPidSkin()

Unexpected termination would occur, when an empty list was given as input.

ANSA-81097

Batch Meshing
General Unexpected termination could occur in Batch Mesh, when some macros were frozen.

BCS-2120

Properties Empty properties after Volume Scenario would not be deleted.

ANSA-80978

BETA CAE Systems 67


ANSA v19.1.0 Release Notes Known problems resolved

Tools Mesh Parameters

Mesh treatment for Fillet row number would not always be respected.

ANSA-65885

Volume Mesh Fix Quality Parameters would not be read, in case database was prior to v18.0.0.

ANSA-82896

Statistics report would erroneous show a 'check mark' even if 0 off elements existed.

BCS-1548

DECKs
Input/ Output ANSA would report no error message in case of input interruption. A relevant
message is now reported both in the Info and File Input Analytics Window.

ANSA-55806

Output The comment of the Include would not be written out, when outputting the include
from the Includes List.

BCS-2344

Checks Penetration [Intersections]

Occasionally, fix operation would not work when a property was selected to be
frozen.

BCS-409

Utilities Transform [Copy]

The initial attributes of the source sets (e.g. Output Type etc.) would not be
transferred to the copied sets (default values were assigned), when Transformation
Options for 'Set' were set to 'Copy/Expand'.

BCS-1453

Lists Includes

Unexpected termination could occur, when replacing an Include.

ANSA-82355

ELEMENTs SHELL [On Line El (Cross Section)]

Applying the function on two or more line elements that share the same property
would lead to unexpected termination.

ANSA-81679

BETA CAE Systems 68


ANSA v19.1.0 Release Notes Known problems resolved

AUXILIARIES CURVE

The 'Add plot' functionality through the context menu list of a *DEFINE_TABLE entity
would not work.

ANSA-71354

GEB

Unexpected termination would occur upon opening a database created before 13.1.0
when containing GEB entities.

ANSA-80016

INV.FORMING

Application on shells with non-uniform orientation would not produce reasonable


results.

BCS-1668

The F1 select from drawing area functionality would not be supported for the
definition of the stamping direction vector in the Workpiece tab.

BCS-1479

RES.MAP

Res Mapper, using the Homogenization option for MOLDFLOW results, would not
give any result, when working on Windows OS.
Now, this mapping can properly work using the converted xml to encode UTF-8.

BCS-2151

When RESULTS MAPPER entity was moved through Utilities> Transform [Move], the
mapped data would be lost.

BCS-1393

Safety Interior [FMVSS 201U]

FH1 target point's position would be erroneously calculated.

BCS-1664

CFD DECKs
CGNS Input/ Output

CGNS files that contained both NGON and other section types in the same zone
would not be imported.

ANSA-82125

BETA CAE Systems 69


ANSA v19.1.0 Release Notes Known problems resolved

Laminates
LIST Generate Report

The drawing of the Pcomp zones on faces would be erroneous, when the Laminate
was defined on geometry.

BCS-2351

Tools
Checks Connectivity

The calculation applied in cases of tied contacts where the master set is allowed to
have elements which their nodes belong to the slave set, would be erroneously
applied on complete model resulting in low performance for PAM-CRASH and
ABAQUS.

ANSA-76466

Penetration [Intersections]

De-penetration action would not take place, either when frozen entities existed or
when an entity was selected to Freeze.

ANSA-76011, BCS-1547

xLINKs [PLINKs]

Error instead of warning would appear, in case NLAYR field was empty or had a
value higher than the actual.

BCS-2196

Includes The Include card fields would be ignored, when a file was loaded.
Manager
ANSA-64239

Settings Decks> Create new IDs [above the current range]

New curve entities created inside their list window would not respect the specific
settings option.

BCS-1484

Plugins
General Adding a new plugin in an existing Plugin Folder would not automatically load it in
ANSA.

ANSA-78077

BETA CAE Systems 70


ANSA v19.1.0 Release Notes Known problems resolved

Safety
Dummy Articulation

For PAM-CRASH dummy models and output of Generator session files, non zero
values would be erroneously output for axes with no articulation.

BCS-1935

SeatBelt The Reference context menu functionality would not work for entities used by a
Seatbelt entity.

ANSA-80558

For RADIOSS, erroneously unnecessary elements would get created.

ANSA-77257

Pedestrian For the CNCAP protocol, the Bumper Corner Target points would get a 25mm offset
on the y axis.

BCS-2153

Interior FMVSS 201U

Erroneous creation of curve for calculating the minimum horizontal angle for B-Pillars
would occur.

BCS-2335

Erroneous initial headform position data would make the FMH 'dissapear' when the
'Reset' button was pressed.

ANSA-77287

Raster The "Paste Tolerance" would not be applied on the area of the FRONT curve.

ANSA-72107

NASTRAN
General FSPD field value of the FREQ4 card would not be stored in ANSA Database.

ANSA-79094

COORDs CORD1R would be erroneously converted to CORD3R during Open.

ANSA-77613

ELEMENTs CBUSH

Occasionally, CBUSHs would be drawn not clearly in the GL area.

BCS-1371

BETA CAE Systems 71


ANSA v19.1.0 Release Notes Known problems resolved

ELEMENTs Joint Assistant

For Kinematic Connections of type "User defined" the direction settings would not be
inherited properly in the respective created CONNECTOR_ENTITY card. When the
database was saved and reopened default values would appear in the direction fields
(X-TRA Type, Y-TRA Type, etc) of the CONNECTOR_ENTITY.

BCS-1938

For Kinematic Connections of all types except "User defined", "Clamp" and "Spheric",
the direction settings would not be inherited properly in the respective created
CONNECTOR_ENTITY card. The direction would be always X regardless Y or Z
defined initially.

ANSA-82524

RSSCON

The RSSCON element would change its TYPE to GRID, if any of its referenced
elements was deleted. Now, the RSSCON is deleted, when deleting any referenced
element.

BCS-1645

RSSCON [New [Multiple]]

Unexpected termination would occur, when assigning newly manually created


RSSCON Elements to a part, after middle-click confirmation.

BCS-1645

UTIL [Mass Balance]

Incorrect message in the "Message board" at the Action step would appear, when the
*ELEMENT_MASS entities were hidden from the Database Browser.

ANSA-77092

BCs ACMODL

The card would be output with empty INFOR field instead of ALL, when METHOD
was CP and INTER=IDENT.

BCS-922

AUXILIARIES DISP. MOD. [Shells]

Original Grid IDs would be erroneously renumbered.

ANSA-76579

PRTENS [INFO]

Creating BOLT (MSC Nastran) with environment variable


ANSA_ENABLE_MODULES=1 would lead to unexpected termination.

44424, ANSA-76999

BETA CAE Systems 72


ANSA v19.1.0 Release Notes Known problems resolved

AUXILIARIES SET

When a SET keyword was found after the header section, it would be erroneously
read as an Optistruct SET.

ANSA-80130

LS-DYNA
Input Erroneous merging of *Control entities that belonged in separate *Include files.

BCS-2244

Confusing messages of ignored columns for material fields with 0 values would
appear.

BCS-874, BCS-2113

The *INCLUDE_TRANSFORM would erroneously transform nodes of


*CONSTRAINED_EXTRA_NODES entities when the nodes were on another include
than the include containing the rigid body definition.

BCS-1162

Abnormal termination would occur, when importing an LS-DYNA file with beam
elements that lack section information.

BCS-2320

In "Comments" tab of "LS-DYNA Input Parameters" window, when the "Read


HyperMesh Comments" flag was enabled, hierarch for parts (HMASSEM_COMP)
would not be read in from HyperMesh comments.

BCS-2910

Output Includes

*ELEMENT_SHELL keyword was not converted to *MESH_SURFACE_ELEMENT


keyword during the output of LSDYNA_CFD_MESH_MODULE from the Includes
window.

ANSA-69767

The keyword *CONSTRAINED_LAGRANGE_IN_SOLID was not written if the output


option "Model" was selected.

BCS-2333

*BOUNDARY_NON_REFLECTING and *CONSTRAINED_LAGRANGE_IN_SOLID


would not be written in the output file when the Output option 'Model' was selected.

BCS-2332

BETA CAE Systems 73


ANSA v19.1.0 Release Notes Known problems resolved

Output When a SET had its 'COLLECT OPTION' set to 'YES' and was empty, the 'COLLECT
OPTION' would not be kept in Output. Moreover, the other SETs, which had
'COLLECT OPTION' set to 'YES', would not be written as Collect Sets.

BCS-1442

Checks Contacts [Contacts From Solver]

The check would fail to read all the information from the "messag" file.

BCS-1709

Properties During input, incorrect *SECTION_BEAM property would be created by default.


BCS-2432
Materials *MAT ADD EROSION

Negative values for the field LCSRS would not be supported.

BCS-2629, BCS-1585

Material DB [List]

The value of a parameter would not be extracted to the corresponding field during
read.

BCS-2281

For *MAT_067 an empty Card 4 would erroneously be replaced by Card 5.

BCS-2416

The *MAT_142 would erroneously have the old name of


*MAT_TRANSVERSELY_ANISOTROPIC_CRUSHABLE_FOAM.

BCS-1583

AUXILIARIES CONTACT

For the *DEFINE_CONTACT_VOLUME, the fields RINNER and ROUTER would be


erroneously considered as diameter values.

BCS-2288

KIN ENTS [KIN BODY]

Unexpected termination would occur on Windows OS when the contents of a body


were modified through 'Modify Contents' of context menu.

BCS-1556

TRANSFRM

The *ELEMENT_SEATBELT_RETRACTOR entity would lose its *SET reference.

BCS-2106

BETA CAE Systems 74


ANSA v19.1.0 Release Notes Known problems resolved

PAM-CRASH
Input BAGIN

If a wrong keyword existed between supported keywords for Vent Hole definition, the
reading would stop and would not read the rest of Vent Hole definitions.

BCS-1918

Reading would be ended, when an unknown keyword existed under the FPM sub-
keyword.

BCS-1913

The INDND of the OTMCO / would not get updated, when the node ID got offset due
to conflict resolution.

ANSA-77486

Materials Material Type 127

Fields of different type (ERATEx, ERATExnf and ERATExsf) would be erroneously


cross-checked for values with ascending order and would not allow the material card
to close.

BCS-2917

Material Type 151

Fields of card 5 for EXMPT would be missing.

BCS-1919

LOAD BDFOR [Assistant]

The Pretension Assistant would assign wrong vector definition in the generated
GEB_BC.

ANSA-82377

DAMP

During input, ANSA failed to read correclty the curve ID assigned in the IFUN field of
the DAMP card.

BCS-2446

Safety Dummy

When reading GNS ses files, '!' would be considered a comment character.
Moreover, ROT_LIMIT keywords would not be read from pos files.

BCS-1049

The output and input of Generator ses files would use relative to initial rotations
instead of total values for both the dummy and seat joints.

BCS-998

BETA CAE Systems 75


ANSA v19.1.0 Release Notes Known problems resolved

Safety Dummy [Articulation> Output GNS file]

Rotation of Revolute Joints (Hinges) would be erroneously output as if it was around


the T axis.

ANSA-77536

Abaqus
Input *PARAMETER

Unexpected termination would occur, when *PARAMETERs were assigned to


*BOUNDARY and/or *STEP keywords.

ANSA-78063

Unnecessary warnings about missing direction cosines would be given, when


inputting Fasteners with ATTACH.METHOD that involved Edges while the V1, V2, V3
fields were empty.

BCS-2588

Output A defined LC Point that resides in a Substructure domain would be exported as


DEFINED=NO.

ANSA-80670

SDV output request would have erroneous definition during Input/ Output.

BCS-2364

Simulation run output would lead to writing the STEP keywords in wrong position
(beginning instead of the end) in the main file (.inp), leading the solver to fail.

ANSA-80745

Utilities File Input Analytics

Importing DLOAD applied on solid facet would report false positive error (DLOAD
BEAM error) in the input log.

BCS-2572

Quality Criteria

The absence of STEP MANAGER would lead to erroneously calculated 'crash time
step' criterion.

BCS-1600

BETA CAE Systems 76


ANSA v19.1.0 Release Notes Known problems resolved

Lists Properties

Orientation distribution tables were not written when a membrane section (TYPE:
M3D_) was assigned to shell elements oriented by angle, unless an Orientation
Offset to Nodes CS was used in the properties ORIENT field.

BCS-1073

Laminates During input, parameters assigned to OFFSET would not be preserved.

ANSA-80147

COORDs NODE

Erroneous output of Coordinate System of type ORIENTATION_NODES_DYN would


occur.

ANSA-80153

LOADs DLOAD
When a DLOAD was applied to an empty set a DLOAD keyword would be written
during output with no data line.
ANSA-77860
INIT.CONDIT. INIT.COND. [Volume Fraction]

The INITIAL CONDITIONS, TYPE=VOLUME FRACTION card would close, if MID


hosted a material that was not used by EULERIAN SECTION.

ANSA-77144

AUXILIARIES CONTACT

When changing a Contact Pair from Master/Slave to Master/All, the slave set would
remain connected to the Contact Pair.

BCS-1106

CONTACT [Assistant]

The element master and node slave types would be inverted, when flipping Contact
Pairs.

BCS-1710

INV.FORMING

The variable dependencies of yield stress and plastic strain with blank temperature in
a *PLASTIC material model could not be used for the calculation of Hardening K and
n fields from the 'Calculate K,n' button at the Material tab.

BCS-1234

BETA CAE Systems 77


ANSA v19.1.0 Release Notes Known problems resolved

AUXILIARIES PRTENS [Assistant]

The Pretension Assistant would assign wrong vector definition in the generated
GEB_BC.

ANSA-80738

STEP [New [Loadcase]]

Unexpected termination would occur on Windows OS, when applying a Loadcase


Setup Assistant with a Results Mapper.

ANSA-77529

RADIOSS
General TH_GAUGE and TH_FRAME entities could not be placed within an INCLUDE.

BCS-1474

/KEY entity could not be placed within an INCLUDE.

BCS-1372

The computation of ANSAPART's characteristics in Model Browser would give


erroneous results in case an RBODY,
which would lay on the NODEs of the included mesh, was not within its contents.

ANSA-80059

Input Input of /PROP/TYPE14 would result in confusing message of missing the Sol2SPH
options.

BCS-2439

Invalid assignment of offset IDs during 'Merge model with current model' Model
Action in order to resolve conflicts for node references in /MONVOL/AIRBAG1 and
/MONVOL/COMMU1 and material reference in /MONVOL/FVMBAG1.

ANSA-77714

Importing a REFSTA file would remove coordinates from nodes if refsta node visibility
was activated.

BCS-963

A /MAT/GAS would be erroneously created when /MONVOL/AIRBAG (Obsolete) was


input.

ANSA-76696

Handling of /REFSTA would be erroneous when the General tab option "Header
Merge" was activated.

ANSA-76850

BETA CAE Systems 78


ANSA v19.1.0 Release Notes Known problems resolved

Output Erroneous output of entities with Names expanding in more than one line.

BCS-1758

For the /XREF entity, the Part Identifier information would not be maintained.

ANSA-77229

Erroneous output of /SURF group containing solid properties with excluded solid
elements.

BCS-2766

Erroneous group output when used by /MONVOL/AIR and the 'OUTPUT TYPE' field
was blank.

ANSA-77370

ANSA comments would be erroneously output as Include file definition.

BCS-1706

Erroneous surface group output with excluded group structure would occur.

ANSA-77234

Properties For /PROP/TYPE51 and /PROP/TYPE17, the ply property identifier for layers would
be erroneously renumbered.
For /PROP/TYPE19, the name would not be maintained.

BCS-986

Materials The field of Reference density would not be supported for /MAT/LAW65,
/MAT/LAW66, /MAT/LAW76, /MAT/LAW77, /MAT/LAW82 and /MAT/LAW83.

BCS-824

TIME Contents of /TH/PART could not be modified through 'Modify Contents' function of
HISTORY context menu.

BCS-2304

AUXILIARIES CONTROL

The "DELETE FILE" for the REFSTA entities would not erase all REFSTA_NODE
entities from the Database Browser.

ANSA-76333

FUNCT

The Plot Area of the function would not get updated when an Fscaley value from a
related /MOVE_FUNCT would be converted from the corresponding SFO field of
*DEFINE_CURVE in LS-DYNA.

ANSA-77150

BETA CAE Systems 79


ANSA v19.1.0 Release Notes Known problems resolved

AUXILIARIES INITIAL [SHELL]

The entity would be assigned to an erroneous shell when it referenced an element


identifier common for a /SHELL and a /SH3N.

BCS-1871

INTERFC [List]

'Replace Segments' of context menu would produce EDGEs instead of SHELLs for
Interfaces of TYPE 2.

BCS-1356

LAMINATE [LIST]

Manually defined offset values (Zi) of contiguous layers of a composite property


would be lost when selecting it.

ANSA-74060

RES.MAP

Mapping of /INISHE/STRS_F or /INISH3/STRS_F and /INISHE/EPSP_F or


/INISH3/EPSP_F containing stress information would create multiple erroneous
entities.

ANSA-76822

When Equivalent Plastic Strain and Nodal Thickness Mapping Types are requested,
the thickness information from the /INISHE/EPSP_F would be overwritten by the
mapped nodal thickness.

BCS-2501

ANSYS
LOADs SFE

SFE distributed loads with values other than 0,1 in the "facet" card field, would not be
displayed with the correct orientation.

The "facet" field in SFE entity card is now considered for shells also in order to
respect the definition of the ANSYS facet according to the ET of the underlying
element.

ANSA-45862

BETA CAE Systems 80


ANSA v19.1.0 Release Notes Known problems resolved

PERMAS
Input/ Output In a multi-include model, ELPROP_SHELL properties would not output their THICK
values.

ANSA-78831

When Medina models were imported for a PERMAS model, zero values for density,
thermal expansion and structural damping would be misinterpreted, which would
result in invalid PERMAS material definitions.

BCS-2645

Input When reading a MEDINA file SUPPRESS entities would be erroneously assigned to
empty sets.

ANSA-81394

Checks Duplicate Property/Set Names

The check would not work as case-insensitive, leading to remaining duplicated


Properties or Sets. It now reports names with lower- and upper-case as identical.

BCS-3059

CONSTRAINTS CONTACT

Pressing the OK button of a CONTACT NODE card would clear its CORD.

ANSA-81360

Moldex3D
Checks Melt Entrance

New check is now supported to ensure that not partial nodes of a facet have been
assigned Melt Entrance point attribute.

ANSA-76626

ELEMENTs POINT ATTR

Importing model with Sensor/Measure/Fix node attributes would not be recognized


and created in ANSA. In accordance, creating and exporting these attributes from
ANSA would not be written out.

TAITherm
ELEMENTs INFO

A Multilayer Part would turn into Shell Part, when the Cancel button was pressed.

BCS-2535

BETA CAE Systems 81


ANSA v19.1.0 Release Notes Known problems resolved

OPTISTRUCT
Output Undefined Nodes would be output.

BCS-3176

B.C. SETs HEADER

The EIGRA (Real Eigenvalue Extraction Data using Automated Multi-Level Sub-
structuring) keyword would not be supported under the METHOD in Subcase
Information Section.

ANSA-79675

CROSS SECTION
Scripting base.DeleteEntity()

Cross section entities could not be deleted, when referenced from a beam property.

BCS-1824

KINETICS
General The faces' cross-hatches would not be updated, when a model was moved to a new
position.

ANSA-77759

Bodies Flex

CM values shown on Information tab of Flex Properties window would be incorrect.

ANSA-79725

Joints Complex [Point to Curve]

The animation of a PTCV marker would appear attached to curve, when the option
"Animate during calculation" option was enabled; otherwise, the marker would appear
unattached to the curve.

ANSA-64206

Design Design Simulator


Analysis
Individual results per trial could not be plotted, even when the 'Results per Trial'
option was activated.

ANSA-80999

BETA CAE Systems 82


ANSA v19.1.0 Release Notes Known problems resolved

Design Measure
Analysis
Incorrect values would be shown on plots of Kin_Measures during simulation,
although the values were correct when plotted afterwards within the Results Viewer.

ANSA-77030

Measure [Angle]

The 'INCLUDED_ANGLE' TYPE would return incorrect values.

60064, ANSA-38550

Auxiliaries Flex [Builder]

Unexpected termination could occur, when confirming the last step of the Flex Builder
process.

ANSA-81077

Glue contact entities would not be written out properly leading to incorrect Nastran
files.

ANSA-79195

Simulation Results

During results file output the KIN entities names would be written incorrectly. As a
consequence, no animation would be visible in META.

ANSA-79819

Simulator

Bodies consisting of CAD geometries would return to wrong position after animating
a model.

ANSA-80029

Erroneous warning messages would appear in Info window during simulation even
when the recommended solver was used.

ANSA-78820

Unexpected termination would occur when a SET was selected in the Flex Body
Results Topology window.

ANSA-79010

BETA CAE Systems 83


ANSA v19.1.0 Release Notes Known problems resolved

MORPH
Boxes New [Adapt> Bounds]

The selection of solid elements was not supported. Any attempt to redefine a box
would lead to unexpected termination.

ANSA-78517

Controls History

The option "Create Deform" would create a Deformation Parameter with target value
2.0 instead of 1.0.

ANSA-78027

Parameters

The DFM scale parameter would start from initial value 0 instead of 1.

BCS-1765

Box Fit [To Edges]


Morphing
It would not be possible to fit Morphedges on T_Shell element edges of
SECTION_T_SHELL and TSHELL_LAMINATE properties.

BCS-3006

Direct Create [Opening]


Morphing
After the creation of an Opening and activation of the Reconstruct flag, Reconstruct
function would not start.

BCS-2548

DFM

Hexablock structured mesh, subject to morphing under DFM methods handling the
Hexablock box corners, would occasionally produce non-smooth results.

ANSA-77559

Morphing the parent of linked faces would not provide the same result on child faces.

ANSA-78104

DFM morphing on volume mesh with Domain Finder would not produce accurate
results, when Morphing was set to Fast.

ANSA-79629

Design Change [Feature> Slide]

The function would fail to fill the gap, in case the selected feature contained Red
Bounds.

ANSA-78096

BETA CAE Systems 84


ANSA v19.1.0 Release Notes Known problems resolved

Direct Holes-Tubes
Morphing
The modification of multiple selected holes/tubes was not feasible in Windows
operating system.

BCS-2922

The 'Follow surface curvature' flag would be ignored.

ANSA-80883

Task Manager
DOE Tool Saving the DOE Report under any of the available format would lead to unexpected
termination.

BCS-2702

Scripting
General Script functions that expect a dictionary as input argument would not raise a
TypeError, if a variable of different type was passed instead.

ANSA-75778

ReportPenetratedPairsOfPIDs()

Unexpected termination would occur when the session was executed to use more than one number of
processors.

ANSA-77221

base.AddToAnnotation()

The function would lead to unexpected termination, if the second parameter was None.

BCS-1894

base.ChangeElemType()

Function would not work when converting elements that were created in a different deck.

ANSA-76862

base.CheckIntersections()

In same-PID cases, the function would return None, even if intersections existed.

BCS-2466

BETA CAE Systems 85


ANSA v19.1.0 Release Notes Known problems resolved

base.ReportPenetratedPairsOfPIDs()

Unexpected termination would occur when check_type was 1 (intersections check) and solid elements
were involved.

ANSA-76794

base.SetPickMethod()

The function would not work as expected, when the picking method was set to PolyLine via the
respective argument 'base.constants.POLY_AREA_AREA_SELECTION'.

BCS-1798

utils.Messenger()

ANSA messages printed on the terminal would not be suppressed, when inputting files in nogui mode
(via script), although echo(False) was set.

BCS-2493

Scripts Collection
ApplyFilmCSV.py

Unexpected termination would occur while running the script.

BCS-2229

BETA CAE Systems 86

You might also like