You are on page 1of 19

The Smart Grid - Constant Energy in a World of Constant Change

SICAM PAS V8.0


SICAM PQS V8.0
SICAM PQ Analyzer V3.0

Restricted © Siemens AG 2013 All rights reserved. Answers for infrastructure and cities.
Content
Overview – new features

• SICAM PAS V8.0


• “Typical Wizard”
• Centralized feeder Automation with SICAM 7SC80
• IEC60870-5-104 Master supports “Logical devices”
• IEC61850 Client – Import SCD from DIGSI 5 V2.0
• IEC60870-5-101 / -104 Slave – online Paramter in redundant Configuration
• Further Improvements
• Compatibility
• SICAM PQS V8.0 and SICAM PQ Analyzer V3.0
• SIMEAS R, SIMEAS Q80 - Start time of device data retrieval
• SIMEAS R – Test mode data archive
• UI Operation – “Archive Activity Monitor”
• Manual Import of PQDIF and further improvements
• Improved Calendar Tool in Report Browser
• Demo Archive expanded and improved

Restricted © Siemens AG 2013 All rights reserved.


Page 2 February2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

SICAM PAS UI Configuration


 “Typical Wizard”
 Reduction of configuration effort provided by two features
 “Paste multiple”
for master devices includes properties, mappings and topology assignments

 “Copy Control Center Mappings”


for slave connections
Restricted © Siemens AG 2013 All rights reserved.
Page 3 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

SICAM PAS UI Configuration


 “Typical Wizard”
Use cases “IEC61850” and also later adaptations supported by corresponding
 “Update multiple”
 Predefined and user configurable formulas

Master Slave
IEC60870-5-101 IEC60870-5-101
Supported IEC60870-5-104 IEC60870-5-104
IEC60870-5-103
Protocols
& IEC61850 IEC61850
Applications DNP3 DNP3
Modbus Modbus
SoftPLC
SICAM SCC

 Redundant Configurations will be supported with next release (V8.01)


Restricted © Siemens AG 2013 All rights reserved.
Page 4 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

SICAM PAS UI Configuration - SoftPLC


Centralized Feeder Automation with 7SC80
 typical Feeder Automation application can be
solved with 7SC80s AND SICAM PAS
 In this solution the feeder automation logic is
being processed centralized in
SICAM PAS-SoftPLC
 FASE V2.0 (delivery release upcoming)
 Definition of the feeder automation logic
 provides automation program for SICAM PAS
 provides (together with DIGSI) the SCD
 Both SCD (IEC61850) and automation program (SoftPLC) can be imported in SICAM PAS

 Further information available in


 FASE V2.0 manual (chapter 10)
 Document “Workflow description for Feeder Automation with FASE” (chapter 4)

Restricted © Siemens AG 2013 All rights reserved.


Page 5 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

SICAM PAS UI Configuration - SoftPLC


Centralized Feeder Automation with 7SC80
 FASE V2.0 supports automation programs for several “operational sequences”
operational sequences Decentralized (7SC80, GOOSE) centralized (7SC80 & PAS)

Isolation X X

Restoration X X

Sectional control X X

Sectional control restoration X X

Source transfer X X

Source transfer restoration X X

Load balancing X -

Load balancing fault X -

 compared with decentralized solution (without SICAM PAS)


 no GOOSE between 7SC80  less requirements for communication infrastructure
 no 7SJ64 for HMI
 no additional device (“mode switch”) for device spanning automation logic
 more feeder supported (up to 40 devices)
Restricted © Siemens AG 2013 All rights reserved.
Page 6 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

Communication with RTUs / IEDs


 IEC60870-5-104 Master
supports “Logical devices”
( several CASDUs)

In the addressing scheme for the


objects of the connected RTU / IED
• next to the Information Object
address (IOA)
• also the C(ommon) ASDU
is used.

The Import and Export of the interface describing XML-file support this feature as well

 For IEC60870-5-101 Master this feature is planned to be supported with V8.01


Restricted © Siemens AG 2013 All rights reserved.
Page 7 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

SCD-Data exchange with DIGSI 5 V2.0


 IEC61850 Client – SCD Import
 In DIGSI 5 V2.0 in the “Communication
Mapping” there is an additional column
“IEC61850” available
 With this column the information objects
which should be used with SICAM PAS
can be selected
 SICAM PAS IEC61850-Import function will
take over the selection
in the “used” column.

Restricted © Siemens AG 2013 All rights reserved.


Page 8 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0

Communication with Control Center


 IEC60870-5-101/-104 Slave - Online Parameter
In redundant Configurations thresholds
which are changed online with TI 110 … 112
are automatically exchanged to standby computer Control
Center

Thresholds with
Thresholds have not to TI 110 … 112
be transmitted again
after switch-over
X X
T101 Y Y T101
T104 z R z T104

SICAM PAS SICAM PAS

exchanged
automatically

Restricted © Siemens AG 2013 All rights reserved.


Page 9 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS V8.0
Further Improvements

SICAM PAS UI Configuration

 Additional “clean up” features


in context of “Compress database”
 deselect all unused master data points
 delete all unused IEC61850 Client data
points

SICAM PAS UI Other aspects

 IEC61850 Client Monitoring  Export for SICAM SCC


for Fault record support only  Connection parameter supported
 Info Object mapping not needed
 Security aspects
 Customer Diagnostics also supported for
 Database access only for members
 IEC60870-5-103
of Windows users group
 OPC Client / Server
“SICAM PAS PQS Users”
 Profibus FMS (SIPROTEC 4)  Dongle driver update
 SIPROTEC 4 Service Interface
Restricted © Siemens AG 2013 All rights reserved.
 Multicore-CPU support improved
Page 10 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PAS / PQS V8.0
SICAM PQ Analyzer V3.0

Compatibility and further hints


 Supported Operating systems
 same as for V7.0x and V2.0x
 SICAM SCC
 SICAM PAS V8.0 can be used together with SICAM SCC V7.0x
and in the future also with SICAM SCC V8.0
 SICAM PQ Analyzer V3.0 *)
 can also be used together with SICAM PAS/PQS V7.0x
 SICAM PAS / PQS V8.0 *)
 can also be used together with SICAM PQ Analyzer V2.0x

 SICAM PAS Applications (6MD9000-0PA01-8AA0) is planned to be released in 04/20013

 Manuals will only be provided electronically


(not orderable as printed versions)

*)
features depending on other system’s functionality
Restricted © Siemens AG 2013 All rights reserved.
Page 11 February 2013 Sector Infrastructures & Cities / Energy Automation
The Smart Grid - Constant Energy in a World of Constant Change

SICAM PQS V8.0


SICAM PQ Analyzer V3.0

Restricted © Siemens AG 2013 All rights reserved. Answers for infrastructure and cities.
SICAM PQS V8.0

SIMEAS R / SICAM Q80


 PQ Data Transmission
Start time of device data
retrieval can be configured

Define for SIMEAS R and


SICAM Q80 devices,
from which date/time on
the historical Data
(Fault records, PQ Data)
should be retrieved starting
SICAM PQS for the first time.

Restricted © Siemens AG 2013 All rights reserved.


Page 13 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PQ Analyzer V3.0
SICAM PQS V8.0

Test mode data Archive


 SIMEAS R can run in “Test Mode”
Data recorded in Test Mode
can now be visualized as
Test mode data archive.
You can switch to it with the
“Select archive” dialogue

 In Test mode, only


 Incident Explorer
and
 PQ Explorer
views are displayed.

Restricted © Siemens AG 2013 All rights reserved.


Page 14 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PQS V8.0
UI Operation

Archive Activity Monitor


 UI Operation with its lights displays e.g. the status of the communication connections
additionally
 The new view “Archive activity monitor” shows whether data is currently stored in the
archive

 Supported information
 Store scheduled reports
 Store PDR records
 Store slow scan records
 Store fault records
 Store fault location reports
 Store measured characteristics
 Store evaluated characteristics
 Store PQ violation reports

Restricted © Siemens AG 2013 All rights reserved.


Page 15 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PQS V8.0
SICAM PQ Analyzer V3.0

Manual Import for PQDIF and Further improvements


 SICAM PQ Analyzer
You might be interested in evaluation of data
from devices which are not connected to (but
configured) the SICAM PQS system.
Next to “manual import of Comtrade files”
now also “manual import for PQDIF files” is
supported.

 SICAM PQS – SIMEAS R


 “Port Forwarder” supported
 Logfiles can be continuously stored up to 10 Mbyte

 Automatic Comtrade Import


 Fault records from different devices in one folder

Restricted © Siemens AG 2013 All rights reserved.


Page 16 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PQ Analyzer V3.0
Report Browser

Calendar Tool
 Easy handling of Calendar Tool is now also available in the Report Browser
 unified functionality for all views

adjust the time range


by just clicking the calendar

Restricted © Siemens AG 2013 All rights reserved.


Page 17 February 2013 Sector Infrastructures & Cities / Energy Automation
SICAM PQ Analyzer V3.0

Demo-Archive
 To get in touch with a lot of the possible charts, diagrams and tables
for almost all typical use cases the content of Demo-Archive was expanded
for Incident Explorer, PQ Explorer, PQ Inspector and Report Browser

 An according chapter in
the SICAM PQ Analyzer
Manual describes the
content and gives you
a helping hand about
what can be found where

Restricted © Siemens AG 2013 All rights reserved.


Page 18 February 2013 Sector Infrastructures & Cities / Energy Automation
Gerhard Fürst
PLM
IC SG EA PRO LM2
Phone: +49 (911) 433-7027
E-mail:
gerhard.fuerst@siemens.com