You are on page 1of 2

DRAWN WITH ALL COMPONENTS SHOWN IN FAILED POSITION

ACTUATOR CLOSING DIRECTION: CW FAIL MODE: CLOSED

A
A
28
10 SYMBOLS
X
X HYDRAULIC LINE
B P R
1 NORM. OPEN VALVE
X ACC2
12 PR PP PX PA NORM. CLOSED VALVE
PILOT VALVE
B MANIFOLD
14 15
AUX P1
7 X
25 RP
32
19

ACC T1
13 33 CR
A1
8 RT ACC3 CB
9 DIELECTRIC FITTINGS
GAUGE 16
11
7
EH CONTROLLER LOCAL/REMOTE/OFFLINE
MANIFOLD PUSH BUTTON
P T
31 30
17
MECHANICAL
20 CONNECTION 2

REMOTE P T
HYDRAULIC
A POWER UNIT 23 18
(HPU) 26 24

27
CAUTION
22
TO AVOID ACTUATOR DAMAGE, ENSURE VALVES 22, 26, AND
29 31 ARE OPEN AND VALVES 27 AND 32 ARE CLOSED BEFORE
M RETURNING THIS ACTUATOR TO NORMAL SERVICE AFTER
6 MANUAL OPERATION OR SERVICING.
5 4 4
21
05 080212 TFF AS-BUILT CORRECTIONS AND ITEM
NUMBER CORRECTIONS EH SRQ ACC SAFETY HI_FLOW
ADDITIONAL 04 061112 JR MINOR TEXT AND SYMBOL
ACCUMULATORS 3 CORRECTIONS AND ADDITIONS www. .com
AS REQUIRED 03 052112 TFF ADDED RELIEF VALVE AND PRESS. ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: TFF Schematic Diagram No Issue No Sheet No
REGULATOR AT ACTUATOR Date : 040212
BATH, BA1 3JQ ROCHESTER
02 042412 TFF DIFFERENT HPU CONFIGURATION
ENGLAND NY 14624, USA
01 040212 JR FIRST ISSUE Job No : -- 1 of 2
Iss Date Chkd Revision Details Tel:01225-733200 Tel:585-247-2304 MOD No : --
HS21115 05
1 2 3 4
DRAWN WITH ALL COMPONENTS SHOWN IN FAILED POSITION
ACTUATOR CLOSING DIRECTION: CW FAIL MODE: CLOSED
DESCRIPTION OF OPERATION
EH SPRING RETURN ON/OFF HYDRAULIC CIRCUIT SAFETY ACTUATOR
THIS EH SPRING RETURN ACTUATOR HAS BEEN REVIEWED FOR SUITABILITY
THE MANIFOLD HAS TWO REDUNDANT EMERGENCY SHUTDOWN (ESD) SOLENOID VALVES (10AND 12). IF FOR USE IN SIL APPLICATIONS. IT IS CLASSIFIED AS A "TYPE A" DEVICE
EITHER SOLENOID VALVE DE-ENERGIZES, THE ACTUATOR SPRING CLOSES THE VALVE. A ACCORDING TO IEC61508, FOR LOW DEMAND MODE. THE ACTUATOR AND
REMOTE-MOUNTED ACCUMULATOR BANK PROVIDES CLOSING SPEED ADJUSTABILITY AS WELL AS CONTROL SYSTEM CAN BE USED UP TO SIL3 AS A "SINGLE DEVICE"
POWER TO OPEN THE VALVE AFTER AC POWER IS LOST. MOTOR ON/OFF IS CONTROLLER USING ASSUMING A FULL-STROKE TEST INTERVAL OF 1 YEAR, A PARTIAL-STROKE
PRESSURE SWITCH 20. TEST INTERVAL OF 3 MONTHS, AND PARTS ON HAND TO ENSURE A 48 HOUR
MEAN TIME TO REPAIR. ALL OTHER DEVICES IN THE SAFETY INSTRUMENTED
NORMAL OPERATION FUNCTION (SIF) MUST BE CONSIDERED IN ORDER TO DETERMINE
B TO OPEN THE ACTUATOR, SEND OPEN SIGNAL VIA LOCAL OR REMOTE CONTROLS. THIS WILL ENERGIZE SUITABILITY FOR A SPECIFIC SIL LEVEL.
SOLENOID VALVES 10, 12, AND 13. SOLENOID 13 WILL DE-ENERGIZE WHEN VALVE IS OPEN. ADJUST
OPENING SPEED USING FLOW CONTROL 15. TO PROVIDE THE SAFETY FUNCTION:
TO CLOSE THE ACTUATOR, SEND A CLOSE SIGNAL VIA LOCAL OR REMOTE CONTROLS. THIS WILL VALVE 31 MUST BE LOCKED IN THE OPEN POSITION AND FLOW CONTROL 14
DE-ENERGIZE SOLENOID VALVES 10 AND 12, AND THE ACTUATOR SPRING WILL FORCE THE VALVE MUST BE SET TO PROVIDE THE APPROPRIATE CLOSING SPEED.
CLOSED. ADJUST CLOSING SPEED USING FLOW CONTROL 14. ACTUATOR WILL FAIL CLOSED ON LOSS
OF POWER TO EITHER SOLENOID VALVE 10 OR 12.

LOCAL ELECTRICAL OPERATION


PLACE LOCAL/REMOTE SELECTOR IN LOCAL POSITION. OPEN OR CLOSE ACTUATOR USING OPEN/CLOSE
SELECTOR SWITCH.

MANUAL OPERATION WITH ACCUMULATOR (NO POWER) 24 HIGH PRESSURE FILTER W/CLOG INDICATION 1
TO OPEN ACTUATOR, CLOSE VALVE 31 AND OPEN VALVE 32. 23 PRESSURE GAUGE 1
TO CLOSE ACTUATOR, OPEN VALVE 31. 22 ACCUMULATOR ISOLATION VALVE AR
21 HYDRAULIC ACCUMULATOR AR
MANUAL OPERATION WITH HAND PUMP (NO POWER) 20 PRESSURE SWITCH 1

TO OPEN ACTUATOR, CLOSE VALVES 26 AND 31. OPEN VALVE 32 AND CYCLE HAND PUMP 6. 19 HIGH PRESSURE FILTER 1
18 HYDRAULIC FILTER W/ CLOG INDICATION 1
TO CLOSE ACTUATOR, OPEN VALVE 31.
17 PRESSURE REDUCING VALVE 1
16 RELIEF VALVE 1
15 FLOW CONTROLLER - OPEN SPEED CONTROL 1
14 FLOW CONTROLLER - CLOSE SPEED CONTROL 1
REFER TO ELECTRICAL DIAGRAM AND IOM PUB021-034-00 FOR CONNECTIONS AND OPERATION 13 2WAY 2POSITION NORMALLY CLOSED SOLENOID VALVE 1
12 2WAY 2POSITION NORMALLY OPEN SOLENOID VALVE 1
1 11 PRESSURE GAUGE 1
33 CALIBRATED WEEP ORIFICE 1 10 2WAY 2POSITION NORMALLY OPEN SOLENOID VALVE 1
32 BALL VALVE - FOR HAND PUMP AND MANUAL ACCUMULATOR 1 9 HIGH PRESSURE FILTER 1
A OPERATION
8 RELIEF VALVE 1
31 BALL VALVE - FOR HAND PUMP AND MANUAL ACCUMULATOR 1
OPERATION 7 CHECK VALVE 2
30 EH CONTROL HOUSING 1 6 HAND PUMP 1
29 RELIEF VALVE 1 5 PUMP / MOTOR / CHECK VALVE / RELIEF VALVE COMBINATION 1
28 3-WAY 2-POSITION PILOT VALVE 1 4 SUCTION STRAINER 2
27 ACCUMULATOR DRAIN VALVE AR 3 HYDRAULIC RESERVOIR 1
26 ACCUMULATOR SYSTEM ISOLATION VALVE 1 2 ROTORK HYDRAULIC SPRING-RETURN ACTUATOR 1
25 RELIEF VALVE 1 1 PRESSURE TRANSDUCER 1
ITEM DESCRIPTION QTY ITEM DESCRIPTION QTY

LIST OF PARTS LIST OF PARTS


EH SRQ ACC SAFETY HI_FLOW
www. .com
ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: TFF Schematic Diagram No Issue No Sheet No
BATH, BA1 3JQ ROCHESTER Date : 040212
ENGLAND NY 14624, USA
Job No : HS21115 05 2 of 2
Tel:01225-733200 Tel:585-247-2304 MOD No :

1 2 3 4