You are on page 1of 13

Batch OTDR Trace Report 22 May 2013

UIPS
84 ANALYZER 01 PROJECT,
SADAF, JUBAIL INDUSTRIAL CITY
JUBAIL, EP
KSA

Prepared By: jim

Phone: 0505587551

Email: mijnat@yahoo.com

Job: FINAL OTDR INSERTION LOSS TESTING (db loss per km)

Tested By: jim

Cable Information
Cable ID: FOC-84-AS-01
Cable Type: MM 12 FIBER (Out Door)
Test Site: 84-AS-01
Far Site: 86-CBI-ANALYZER-01R
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 1 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER001.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.5 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.2 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.73 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 2 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER002.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 131.2 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.4 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.73 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 3 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER003.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 131.2 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.4 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.70 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 4 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER004.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.9 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.7 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.72 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 5 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER005.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.3 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.4 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.70 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 6 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER006.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.0 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.6 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.72 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 7 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER007.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 131.2 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.5 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.74 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 8 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER008.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.3 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.4 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.75 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 9 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER009.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 131.0 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.6 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.72 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 10 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER010.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.5 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.2 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.74 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 11 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER011.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 130.6 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 200.0 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.73 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A
OTDR Trace Report 22 May 2013
_______________________________________________________________________________________
Fiber #: 12 Test Site: 84-AS-01
Wavelength: 850 nm Far Site: 86-CBI-ANALYZER-01R
Cable ID: FOC-84-AS-01 Tested By: jim
Cable Type: MM 12 FIBER (Out Door) Test Date:15 May 2013
_______________________________________________________________________________________
File: C:\Users\PFC\Desktop\84-ana\Final\dbkm\B\850\FIBER012.M85
Comment:
_______________________________________________________________________________________
Module: M600-MM1 Auto Events: On Cursor A: 131.4 m
Port: Multimode Loss Thresh: 0.1 dB Cursor B: 330.6 m
Range: 2,000.0 m Refl Thresh: -65.0 dB A-B Distance: 199.2 m
Pulse Width: 100 ns End Thresh: 6.0 dB A-B Loss: ------
Averages: 2048 Group Index: 1.49600 A-B Loss/km: 2.70 dB/km
Auto Setup: Off BackScat Coef: -68 dB Format: 169
dB A B
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0 130 260 390 520 650 780 910 m
Event Table
Number of Events: 0 Link Loss: N/A Link Length: N/A

You might also like