Professional Documents
Culture Documents
a r t i c l e i n f o a b s t r a c t
Article history: In the present study, the effectiveness of fibres in transferring stress across cracks under a sustained load
Received 10 July 2015 was assessed. Single fibre pull-out creep tests were performed, in which fibre slip was monitored as a
Received in revised form function of the time. The influence of the fibre orientation angle (0, 30 and 60 ), as well as pre-imposed
14 November 2016
fibre slip levels, spr, 0.3 and 0.5 mm on the creep response was investigated. Additionally, instantaneous
Accepted 7 December 2016
fibre pull-out tests were carried out on undamaged-bond specimens in order to quantify the effects of
Available online 7 December 2016
the pull-out creep behaviour. The damage introduced by the pre-slip levels in the bond of the fibre/
matrix interface influenced the long-term fibre pull-out behaviour and, consequently, accelerated the
Keywords:
Time-dependent behaviour
creep rate. However, the assembled pull-out creep behaviour did not differ considerably from the
Long-term load instantaneous pull-out behaviour for the adopted pre-imposed fibre slip levels.
Creep © 2016 Elsevier Ltd. All rights reserved.
Fibre pull-out
Bond
Steel fibre reinforced self-compacting
concrete
http://dx.doi.org/10.1016/j.cemconcomp.2016.12.004
0958-9465/© 2016 Elsevier Ltd. All rights reserved.
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 15
dependent fibre pull-out behaviour. In the works of Babafemi et al. the constituents included in Table 1. To guarantee the required
and Boshoff et al. [11,12], aligned synthetic fibres (i.e. fibres workability, a third generation Superplasticizer Sika® 3005 (SP)
perpendicular to the crack plane) were pulled-out just in a few hours was used. Crushed granite coarse aggregates with a maximum
after the loading initiation, even when they were loaded with just aggregate size of 12 mm were used. The concrete properties in the
50% of the fibre's bond strength. It is well acknowledged that the fresh state were determined by the Abrams cone slump test in the
orientation of the fibres relative to the crack plane has an important inverted position according to the recommendation of EFNARC [19],
influence on the pull-out behaviour of a single fibre and, conse- having been obtained an average spread of 590 mm. Hooked-end
quently, on the FRC tensile behaviour [3,13]. In fact, understanding steel fibres with a length, lf, of 33 mm; diameter, df, of 0.55 mm;
the time-dependent modifications at the fibre/matrix interfacial aspect ratio, lf /df, of 60 and yield stress of 1100 MPa, were used.
zone of a single fibre (meso-level) can render a better understanding The compressive strength of the hardened concrete was
of the creep behaviour of SFRC at the composite level. assessed by testing six cylinders with a diameter of 150 mm and a
In the present work an experimental programme that aims to height of 300 mm at the age of 28 days according to the ASTM-C39
study the time-dependent pull-out behaviour of a single fibre is [20] recommendations. The specimens were cast and stored in a
presented and discussed. For this purpose, cylindrical concrete climatic chamber room under 20 C and 60% relative humidity.
specimens containing a single fibre with an embedment length of lf Moreover, these specimens were stored in the same climatic con-
/4, lf being the fibre length [14], and distinct inclinations were ditions in which the creep pull-out tests were performed. The
produced. For each series, the influence of the fibre orientation average compressive strength was 72 MPa with a coefficient of
angle (0, 30 and 60 , see Fig. 1), as well as the pre-imposed fibre slip variation (CoV) of 8.23%, while the average Young's modulus was
levels, spr, 0.3 and 0.5 mm on the pull-out behaviour are appraised. 42.15 GPa with CoV of 0.26%. The strength class of the SFRSCC was
In a first stage, the fibres were subjected to a monotonic pull-out selected in order to achieve a post-cracking flexural performance
test up to the desired pre-slip level, spr. Afterwards, the creep required for its use on elevated SFRC slabs (supported on columns)
pull-out test was carried out under a sustained load until the sta- in terms of flexural and punching capacity [21e23].
bilization of the long-term slip. The specimens used in the pull-out
creep tests were then subjected to a quasi instantaneous pull-out 2.2. Specimens
test until failure. Finally, a series of quasi instantaneous single
fibre pull-out tests were also executed on undamaged specimens The pull-out tests were undertaken on single sided cylindrical
(without any pre-slip level), in order to quantify the influence of the concrete specimens. For this purpose, a special mould was used
long-term slip on the pull-out residual force evolution. allowing the production of 81 specimens at the same time with the
At the composite level, the authors also performed an extensive desired fibre's embedment length and orientation, see Fig. 2a. The
experimental programme on prismatic specimens extracted from a bottom surface of the mould consists of ten steel strip shape pieces.
1500 1500 60 mm3 SFRSCC panel [15]. The specimens were Before assembling the mould, fibres were placed with the desired
notched in distinct directions taking into account the expected embedment length and inclination in the grooves of the lateral face
radial concrete flow direction, in order to study the influence of of the steel strip pieces, respectively with 0, 30 and 60 (Fig. 2b).
fibre distribution and orientation on the composite's long-term Hence, the embedment length of the fibre was located in the bot-
behaviour. The pull-out results of this study were used to predict tom zone of the cast panel (Fig. 2a and c), without relevant segre-
the long-term behaviour at the composite level. For accomplishing gation of the concrete constituents due to the relatively small
it, a two-phase material model was employed, which comprises thickness of the panel and proper design mix. Afterwards, the
one homogeneous phase representative of aggregates and paste, mould was cast as shown in Fig. 2c. The casting procedure was
and a second phase including the discrete fibres. The short- and performed carefully, from the centre of panel, in order to prevent
long-term behaviour of the SFRSCC at the composite level can be any undesired fibre's warping. After curing of concrete, the panel
accurately predicted [16e18] with a realistic fibre distribution/ was demoulded, turned over, and cylindrical cores comprising a
orientation and having the knowledge of the micro-mechanical single fibre were extracted. Fig. 2d depicts the final produced cy-
behaviour of a single fibre. lindrical specimen, with actual height and diameter of 80 mm.
Prior to testing, two aluminium plates were attached to the
2. Experimental programme extremity of the fibre, in order to avoid undesired fibre rupture at
the grip, since the specimens that were used for assessing long-
2.1. Concrete mixture term pull-out behaviour needed to be fasten three times (for pre-
slip, creep and post-creep stages). The aluminium plates were
A self-compacting concrete composition was developed with glued using epoxy Sikadur®-32N and stored for at least three days
until the curing process of epoxy was completed. Additionally,
these aluminium plates also guarantee a negligible slip between
fibre and grip, since the grip could be tighten firmly [13].
In this study, inclination angles of 0, 30 and 60 were investi-
gated to assess the influence of fibre orientation on the instanta-
neous pull-out load e slip (F - s) and long-term slip e time (slt - t)
relationships. Cunha et al. [24] concluded that the influence of the
fibre embedment length is not as significant as the orientation
Table 1
Mix constituents of self-compacting concrete per m3.
Fig. 2. Production of the specimens for fibre pull-out test program: (a) casting device, (b) fibres installation in mould, (c) cast panel and (d) extracted pull-out specimen.
angle. Therefore, considering that the theoretical average value of a 2.3. Test set-up
fibre's embedded length, lfb, bridging an active crack is lf /4 [14], in
the present study a lfb ¼ 8.25 mm was selected in the production of 2.3.1. Instantaneous fibre pull-out test
all the pull-out specimens. For each orientation angle, six mono- 2.3.1.1. Monotonic test. The instantaneous fibre pull-out load e slip
tonic and six long-term pull-out tests were undertaken (three for relationship, F - s, was acquired by using a universal testing rig with
each pre-imposed fibre slip level, spr). For the series with an incli- a load capacity of 50 kN. Since the peak pull-out loads were rela-
nation angle of 0 , additional specimens were also prepared, tively low, a load cell with high accuracy was used, namely, a HBM®
namely, six specimens (three for each spr) for executing monotonic type S9 load cell with a capacity of 5 kN. This load cell was inter-
tests with one unloading/re-loading cycle (fibres were loaded until posed between the servo-actuator and the grip, see Fig. 3a.
the nominal pre-slipping value, spr. Then, the specimens were The single sided pull-out specimen was accommodated in a
unloaded followed by a monotonic loading until the failure of the steel frame. This frame incorporated one bottom steel plate bolted
specimen); and three supplementary specimens with smooth fi- to the machine testing frame and a steel ring mounted on the upper
bres to be tested in monotonic configuration in order to determine side of the specimen to fix it. The steel ring was connected to the
the grade of the hooked end mechanical anchorage mobilization. bottom steel plate using three screws disposed around the spec-
Therefore, a total of forty five specimens were tested. imen forming an angle of 120 . The diameter of both specimen
Fig. 3. Configuration of single fibre pull-out test: (a) details of the test, (b) connection details of the LVDTs.
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 17
(80 mm) and steel ring hole (60 mm) were designed to prevent the component related to the fibre elongation. In this study, two
application of confinement to the fibre due to development of nominal slip levels were investigated: 0.3 mm that can be corre-
compressive stress held in the concrete medium surrounding fibre, lated to the crack opening width in serviceability limit states [25],
which could influence the pull-out response. and 0.5 mm that was close to the peak pull-out load. After imposing
For measuring the fibre's slip during the pull-out procedure, the pre-slip, the specimen was unloaded. Finally, the specimen was
three Linear Variable Differential Transformers (LVDTs) with linear carefully removed, in order to avoid any introduction of bending or
stroke ± 5 mm were installed on the back side of grip using torsion when unfastening the fibre from the grip.
aluminium cubic supports to exclude measuring deformation of the
test rig, Fig. 3b. Moreover, to assess the fibre slip at the grip, a VMS- 2.3.2.2. Pull-out creep test. The fibre pull-out creep tests were
004D-400 USB Microscope camera with a 2 Mega Pixels resolu- performed in a climatic chamber room with a fixed temperature of
tion was also used. For the adopted test set-up the fibre slippage at 20 C±0.5 and 60% relative humidity ± 5% as recommended by
the grip was negligible, lower than 4 mm. The test was controlled by ASTM-C512 [26] for the assessment of creep under compression.
an LVDT installed on the actuator, and adopting a displacement rate Before positioning the specimens on the creep table, they were kept
of 1 mm/s up to the slip of 2 mm, and 4 mm/s until the end of the test. in the chamber room for around five hours. For evaluating the long-
This test control procedure guaranteed a stable response during the term performance of the fibre/matrix interface, an innovative test
test, especially during the debonding process of the fibre. set-up was designed allowing five specimens to be tested simul-
taneously (Fig. 5a). The test set-up was composed of a creep table,
2.3.1.2. Tests with one unloading/re-loading cycle. To evaluate if an five LVDTs, a data acquisition system and a computer. In the creep
unloading (in pre-slipping test)/re-loading (in post-creep test) cycle table, a grip, a steel arm that was withheld by a support at a quarter
will affect the peak load and to investigate the influence of the of its length, and a steel bar for supporting the applied weight loads
long-term slip on the secondary stiffness, a series of tests with one exist for each specimen (Fig. 5b and c). The same steel rings used in
unloading/re-loading cycle was also conducted. In this test, fibres the monotonic tests were accommodated on the top of the spec-
were loaded until the nominal pre-slipping value, spr, i.e. 0.3 or imen, connected to the table by three bolts. Furthermore, a hinge
0.5 mm. Then, the specimens were unloaded followed by a was used to connect the grip to the steel arm in order to prevent the
monotonic loading until the failure of the specimen, see Fig. 4. In introduction of bending moment at the fibre, and also to assure that
this figure, hereinafter, sres the specimen was loaded in the fibre's axis, see Fig. 5c.
pr denotes as the residual slip after
unloading of the specimen, Ksec, inst is the instantaneous secondary During the creep test, the fibre slip was acquired with an LVDT
stiffness at re-loading process, Fpmax and smax are the maximum load installed on each grip. The same connection details of the mono-
p
recorded during the test and its correspondent slip, respectively. tonic test set-up were adopted. To evaluate the level of fibre slip-
page in the grip, a USB Microscope was also used, see Fig. 5c. The
fibre slippage at grip was also negligible similar to the monotonic
2.3.2. Long-term fibre pull-out test
tests. In this test at the time of loading and unloading procedures,
To obtain the long-term F - s relationship, experimental tests
the slip was measured within a relatively short time period (one
were carried out in three stages: firstly, the fibres were exposed to a
reading per 2 s) since the slip variation was significant at this stage.
pre-slip level of either 0.3 or 0.5 mm; secondly, the creep tests were
To reduce the amount of the recorded data, the intervals between
carried out for the pre-imposed fibre slip specimens until the sta-
readings was increased, one read-out per 500 and 1000 s for the
bilization of the long-term slip; finally, pull-out tests were per-
first month and until the completion of the test, respectively.
formed until the fibre was fully pulled-out.
After the initiation of the creep test, the value of the applied
load, Fa, see Fig. 6b, was maintained constant until the long-term
2.3.2.1. Pre-slipping of the fibre. Prior to the execution of the long- slip was stabilized. When the variation of the long-term slip was
term pull-out tests, each specimen's fibre was subjected to a certain smaller than one micrometer for three consecutive days, it was
pre-slip level, spr. The monotonic pull-out test set-up was adopted assumed that the slip was stabilized, and the test was finalized. In
for pursuing this objective and the fibre was loaded until the the present research, the load level (Fa/Fpr) selected was equal to
average slip in the LVDTs reached the target spr, and then the 100 or 80% of that observed at spr ¼ 0.3 or 0.5 mm in the pre-slip
specimen was unloaded. Note that the latter slip also comprises a tests, respectively. It should be mentioned that for the specimens
with 0 fibre inclination angle, the pre-slip level 0.5 mm was very
close to the slip at the peak load. Therefore, in the spr ¼ 0.5 mm
series, to prevent the premature fibre's rupturing or pulling-out at
initial stage of creep test, the specimens were subjected to a lower
loading level.
After the creep tests were completed, the specimens were
unloaded, but the data acquisition system was kept active for at
least a period of one week, to also record the recoverable slip
component due to the creep recovery process. Fig. 6a and b include
a schematic representation of slip versus time and force e slip
relationship. In these figures, sinst is the instantaneous slip, slt rep-
resents the long-term slip, srec inst states the instantaneous slip re-
covery at the beginning of the unloading process, srec lt
represents
long-term slip recovery, srec total
is the total slip recovery, sres
lt
is the
residual slip after complete unloading stage, and Fa is the applied
load level in creep test.
2.3.2.3. Post-creep test. One week after the creep tests had ended (a
Fig. 4. Schematic response obtained from the instantaneous pull-out test with one waiting period for creep deformation recovery), the specimens
unloading/re-loading cycle. were then subjected to a monotonic fibre pull-out test. The
18 A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28
Fig. 5. Fibre pull-out creep test: (a) general view, (b) loading details, and (c) specimen installation details.
s F
stotal
s inst s lt
Fa
rec rec
s lt s total s inst
s total rec
s lt
s inst s ltres
s ltres s
( a) (b )
Fig. 6. Definition of the slip parameters in pull-out creep response: (a) slip e time relationship, s - t, (b) force e slip, F - s.
monotonic test set-up was similar to the one used for pre-slipping from the pre-slipping, creep and post-creep responses, as
the fibres, which was previously detailed. schematically presented in Fig. 7. Then the assembled response
was compared with the corresponding curve from the instan-
2.3.2.4. Assembled long-term force-slip curve. Finally, the complete taneous monotonic pull-out tests. In Fig. 7, Fpr and spr are the
F - s curves were assembled with the individual F - s curves pre-slipping load and corresponding slip value, respectively, sres
pr
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 19
Fig. 8. Average monotonic pull-out load versus slip relationships for fibre inclination angles of: (a) 0 , (b) 30 and (c) 60 .
20 A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28
Fig. 10. The average cyclic pull-out load e slip relationships for fibres with inclination angle of 0 and spr equals to: (a) 0.3 mm, and (b) 0.5 mm.
Fig. 11. Long-term slip versus time during fibre pull-out creep test: (a) and (b) 0 , (c) 30 , (d) and (e) 60 ; (a), (c), (d) spr ¼ 0.3 mm and (b), (e) spr ¼ 0.5 mm.
3.2.3. Influence of pre-slip level on the creep parameter orientation angle, the long-term slip increased significantly with
Fig. 14 shows the influence of the pre-slip level on the long-term spr. From Fig. 9, it was observed that for the both studied pre-slip
slip e time responses. Considering specimens with 0 fibre values, the chemical bond was completely exhausted and the
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 23
Fig. 12. Long-term slip versus time for different fibre orientations and spr equal to: (a) 0.3 mm, and (b) 0.5 mm.
Fig. 13. Influence of fibre orientation angle on the long-term slip for spr equal to: (a) 0.3 mm, and (b) 0.5 mm.
Table 4
The average applied load in creep test (Fa, Fig. 5) and maximum load recorded during
the pull-out test (Fmax, Fig. 6) for each series of specimens.
increase. From Fig. 8c it is observed that both studied pre-slip levels almost constant load. Therefore, the achieved pre-slipping load, Fpr,
were positioned in the plateau part of the monotonic pull-out for both investigated pre-slip levels was relatively similar. In the
response of the 60 series, in which the slip increased at an long-term pull-out tests, considering the selected loading levels for
Fig. 15. Comparison of monotonic and long-term assembled curves: (a) and (b) 0 , (c) 30 , (d) and (e) 60 ; (a), (c), (d)spr ¼ 0.3 mm and (b), (e) spr ¼ 0.5 mm.
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 25
each series, the specimens of the 0.5 mm series were subjected to a Fig. 15 includes both the monotonic and long-term pull-out
lower load, Fa, see Table 4. Hence, it is rational to expect that the assembled curves for each fibre orientation category and spr. These
creep response for this series exhibited a response similar to that of responses were obtained by averaging all the corresponding curves.
the 0.3 mm series, even though spr ¼ 0.5 mm series endured a The full response relationship is obtained by overlaying the force e
higher level of damage at the fibre/matrix interface. From another slip curves from the tests corresponding to: the specimen's pre-
point of view, when having in mind the maximum monotonic pull- slipping, creep, and post-creep tests, as schematically represented
out load, the spr ¼ 0.3 mm series were subjected to a loading level of in Fig. 7. The development of the long-term slip has a minor in-
Fa =Fpmax ¼ 54%, whereas the spr ¼ 0.5 mm series the loading level fluence on the post-creep residual forces. It is evident that the
was just 39%. assembled curves resemble quite well the average responses of the
monotonic tests. Nevertheless, in some cases, due to the scatter of
3.3. Comparison between monotonic, cyclic and long-term results the test results, the assembled responses did not follow so closely
the average monotonic curves, nonetheless, they are yet comprised
Considering fibres with a 0 degree inclination, a small reduc- within the experimental envelope of the monotonic pull-out tests.
tion on the instantaneous secondary stiffness, Ksec, inst, obtained
from cyclic test (Fig. 4) can be observed when compared to the 4. Empirical approach to predict time e dependent fibre pull-
long-term secondary stiffness, Ksec,lt (Fig. 7), determined from the out behaviour
post-creep test. The average Ksec,lt was 1.51 and 1.41 kN/mm for the
series with pre-slip levels of 0.3 and 0.5 mm, respectively. When In this section, the experimental results presented in section 3.2
comparing to the Ksec, inst a 12.6% and 14.2% reduction was observed were used to calibrate empirical equations to predict the long-term
for the 0.3 and 0.5 mm series, respectively. This could provide response of the pre-slipped fibre pull-out specimens. For each fibre
corroborating evidence that the creep phenomenon had a minor inclination angle series, the influence of spr and Fa/Fpr parameters
detrimental influence on the interfacial bond between fibre and were taken into account in the present approach. A combined po-
matrix [15]. wer and hyperbolic equation was used, since similar equations
Fig. 16. Comparison between experimental and analytical long-term slip vs. time relationship for series with fibre inclination angle: (a) 0 , (b) 30 and (c) 60 .
26 A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28
were already proposed by ACI 209-92 [29] and CEB [30] to predict The following equation is proposed for predicting the time-
creep behaviour of plain concrete under compression behaviour. dependent fibre pull-out behaviour:
Fig. 17. Influence of Fa/Fpr on the long-term slip vs. time response for spr equal to: (a), (c), (d) 0.3 mm and (b), (e) 0.5 mm; fibre inclination angle of: (a), (b) 0 and (c) 30 and
(d), (e) 60 .
A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28 27
5. Conclusions This work is supported by the FEDER funds through the Oper-
ational Program for Competitiveness Factors - COMPETE and Na-
In the present research, the effectiveness of a fibre as an element tional Funds through FCT - Portuguese Foundation for Science and
for transferring stresses under a sustained load across a crack was Technology under the project SlabSys-HFRC-PTDC/ECM/120394/
assessed by performing single fibre pull-out creep tests, in which 2010. The authors would like to acknowledge the materials sup-
the fibre slip was monitored as a function of time and pull-out load. plied by Radmix and Maccaferri (fibres), SECIL (cement), SIKA and
For this purpose, cylindrical specimens with a single fibre located in BASF (superplasticizers), Omya Comital (limestone filler), and
the centre were cast with distinct fibre inclination angle, and Pegop (Fly ash).
monotonic and long-term pull-out tests were carried out. The in-
fluence of the fibre inclination angle and the pre-imposed fibre slip References
levels on the long-term pull-out behaviour was studied. Finally, the
assembled long-term curves comprising the pre-slipping, creep [1] S.J. Barnett, J.F. Lataste, T. Parry, S.G. Millard, M.N. Soutsos, Assessment of fibre
orientation in ultra-high performance fibre reinforced concrete and its effect
and post-creep responses were compared to the correspondent on flexural strength, Mater. Struct. 43 (2010) 1009e1023.
monotonic ones. [2] S.T. Kang, J.K. Kim, The relation between fibre orientation and tensile behavior
In general, two fibre failure modes were observed during in an ultra high performance fiber reinforced cementitious composite
(UHPFRCC), Cem. Concr. Res. 41 (2011) 1001e1014.
monotonic pull-out tests. In the case of the fibres with inclination [3] A. Abrishambaf, J.A.O. Barros, V.M.C.F. Cunha, Relation between fibre distri-
angle of 0 , the complete fibre pull-out was observed, whereas bution and post-cracking behaviour in steel fibre reinforced self-compacting
for the inclined fibres, fibre rupture was the predominant failure concrete panels, Cem. Concr. Res. 51 (2013) 57e66.
[4] A. Abrishambaf, J.A.O. Barros, V.M.C.F. Cunha, Tensile stress-crack width law
mode. The maximum monotonic pull-out load decreased with
for steel fibre reinforced self-compacting concrete obtained from indirect
the increase of the inclination angle, while the slip at peak load, (splitting) tensile tests, Cem. Concr. Compos. 57 (2015) 153e165.
in general, increased with the angle. This increase of slip at peak [5] K.H. Tan, P. Paramasivan, K.C. Tan, Creep and shrinkage deflections of RC
load could be ascribed to other additional mechanisms in the beams with steel fibres, ASCE J. Mater. Civ. Eng. 6 (1994) 474e494.
[6] K.H. Tan, M.K. Saha, Ten year study on steel fibre-reinforced concrete beams
pull-out process, which include the matrix spalling and fibre under sustained loads, ACI Struct. J. 3 (2005) 472e480.
deformation. [7] W.A. Al-Khaja, Mechanical properties and time-dependent deformation of
28 A. Abrishambaf et al. / Cement and Concrete Composites 77 (2017) 14e28
polypropylene fibre reinforced concrete, J. King Saud. Univ. Eng. Sci. 7 (1995) [19] EFNARC, The European Guidelines for Self-compacting Concrete, 2005.
67e76. [20] ASTM-C39, Standard Test Method for Compressive Strength of Cylindrical
[8] S. Kurt, P. Balaguru, Post crack creep of polymeric fibre-reinforced concrete in Concrete Specimens, Annual Book of ASTM Standards, American Society of
flexure, Cem. Concr. Res. 30 (2000) 183e190. Testing Materials, 2014.
[9] Mouton CJ, Boshoff WP. Initial study on the tensile creep of cracked steel fibre [21] H. Salehian, Evaluation of the Performance of Steel Fibre Reinforced Self-
reinforced concrete. 8th RILEM Internatinal Symposium on Fibre Reinforced compacting Concrete in Elevated Stab Systems: from the Material to the
Concrete: Challenges and Opportunities. Guimara ~es, Portugal, 2012. Structure, Civil Engineering Department, University of Minho, Portugal, 2015.
[10] Zhao G, Prisco MD, Vandewalle L. Experimental research on uni-axial tensile [22] F. Soltanzadeh, J.A.O. Barros, R.F.C. Santos, High performance fiber reinforced
creep behaviour of pre-cracked steel fibre reinforced concrete. 8th RILEM concrete for the shear reinforcement: experimental and numerical research,
Internatinal Symposium on Fibre Reinforced Concrete: Challenges and Op- Constr. Build. Mater. 77 (2015) 94e109.
portunities, Guimaraes, Portugal, 2012. ~o, Assessment of the
[23] J.A.O. Barros, B.N. Moraes-Neto, G.S.S.A. Melo, C.M.V. Fraza
[11] A.J. Babafemi, W.P. Boshoff, Tensile creep of macro-synthetic fibre reinforced effectiveness of steel fibre reinforcement for the punching resistance of flat
concrete (MSFRC) under uni-axial tensile loading, Cem. Concr. Compos 55 slabs by experimental research and design approach, Compos. Part B 78
(2014) 62e69. (2015) 8e25.
[12] W.P. Boshoff, V. Mechtcherine, G.P.A.G. Zijil, Characterising the time- [24] V.M.C.F. Cunha, Steel Fibre Reinforced Self-compacting Concrete: from
dependent behaviour on the single fibre level of SHCC: Part 1: mechanism Micromechanics to Composite Behaviour, Civil Engineering Department,
of fibre pull-out creep, Cem. Concr. Res. 39 (2009) 779e786. University of Minho, Portugal, 2010.
[13] V.M.C.F. Cunha, J.A.O. Barros, J.M. Sena-Cruz, Pullout behaviour of steel fibres [25] EN 1992-1-1, Eurocode 2: Design of Concrete Structures, European Committee
in self-compacting concrete, Mater. Civ. Eng. 22 (2010) 1e9. of Standardization, Brussels, 2004.
[14] P. Stroeven, J. Hu, Effectivness near boundaries of fibre reinforcement in [26] ASTM-C512, Standard Test Method for Creep of Concrete in Compression,
concrete, Mater. Struct. 39 (2006) 1001e1013. American Society of Testing Materials, 2004.
[15] A. Abrishambaf, J.A.O. Barros, V.M.C.F. Cunha, Time-dependent flexural [27] F. Laranjeira, Design-oriented Constitutive Model for Steel Fiber Reinforced
behaviour of cracked steel fibre reinforced self-compacting concrete panels, Concrete, PhD thesis, Universitat Polite cnica de Catalunya, Spain, 2010.
Cem. Concr. Res. 72 (2015) 21e36. [28] T. Soetens, A. Van Gysel, S. Matthys, L. Taerwe, A semi-analytical model to
[16] A. Abrishambaf, V.M.C.F. Cunha, J.A.O. Barros, A two phase material approach predict the pull-out behaviour of inclined hooked-end fibres, Constr. Build.
to model steel fibre reinforced self-compacting concrete in panels, Eng. Fract. Mater. 43 (2013) 253e265.
Mech. 162 (2016) 1e20. [29] ACI-Committee-209, Prediction of Creep, Shrinkage and Temperature Effects
[17] V.M.C.F. Cunha, J.A.O. Barros, J.M. Sena-Cruz, A finite element model with in Concrete Structures, ACI Manual of Concrete Practice, Part 1, ACI 209R-92,
discrete embedded elements for fibre reinforced composites, Comput. Struct. 1997.
94 (2012) 22e33. [30] CEB-FIP, Model code for concrete structures: evaluation of the time depen-
[18] A. Abrishambaf, Creep Behaviour of Cracked Steel Fibre Reinforced Self- dent behaviour of concrete, Comite European du Beton/Federation Inter-
compacting Concrete Laminar Structures, Civil Engineering Department, nationale de la Precontrainte (1999). Lausanne Bulletin d’Information No. 199.
University of Minho, Portugal, 2015.