You are on page 1of 8
Sf Fans-tech Pa AS Product specification P fa WO Fi PRODUCT SPECIFICATION % — AR(NAME): HERO EC centrifugal fan 1 G (MODEL): ‘SC250E5-AGT-02 FLEES (CONFIGURATION CODE) : oon FWACS (VERSION NUMBER) : A/O Sl OWAKE): 4 ee wo corn, _ PQ ‘& (CHECKED) : Zip it HE (APPROVED) : Ayr ae ZF (CUSTOMER APPROVE): A $4 (DATE) = RRMA RA A GUANGDONG FANS-TECH ELECTRIC CO. , LTD. Page | of 8 Sf Fans-tech BRICRDescribing of Alternations Pe Product specification | RRR [BR / MKAS/Version | Alternations Alternations E%/ Name MH /Date reason reason content 1/0 Z HER 2015-07-14 Page2 of 8 PT St Fans-tech Product. specification 1.0 ®EB/ Introduction JSR SBE T PARE, ULE. LOR TRAR. This specification describes the standard . operation environaent. and technicrequirenents of the product. 2.0 PALbRMERIZAUIER/Requirenent of production standard and safety regulations 2.1 AP ALREHORRME / The product satisfy requirements 2.1.1 GB12350 (ssh WLANEL NA TERY 6812350 (Safety requirments of small power motors) 2.1.2 GB/TI3275 «RFE PR Ci BLAM ALA PP BEORD GB/713275 =1000+ (Vfg) Reg Vig i eis 1c “17 Py Yee ‘> Tacho Signal Output = | -——— a ee CRT. output signal under drawing see under annex. Texan = SABLA BLL, SRE SCO L's SLAM, AE NMR LL, ee EHO ANT, BURIAL BL, KURA GEn= 6Of/p, Jka, CAL AM KEM BR, DATE. WLI NS, HEME TTR When the fan stand by, the Tacho signal outputs low voltage; when the fan fault, the Tacho signal outputs high voltage: when the fan is in normal operation, the Tacho signal generates square waves of 50% duty cycle, The frequency of Tacho is equal to the frequency of phase current. Base on the formula n= 60f/p, n is for RPM, f is for frequency, p is for polar couples munbe~. The motor has 5 polar couples. the fan outputs 5 pulses per revolution. 6.1.3 ARIR#AI/Speed control 6.1.3.1 ATLL FAI IZ aa Either of the two methods can be adopted to control speed: Seth. 0~10v0C Linear vol tage:0~10VDC PUM {ES EAT IK~10 Kz, FEEL 10~12V, EEE O8~ 100% PWM signal: frequency IK~1OKHz, amplitude 10~12V, duty cycle 08~100% SRR AUHAT 1.00. 1V at, WbLITMIES, RRMA MURAT 9. IVb Page of PRBS Sf Fans-tech Product specification AMIE, “ABLE, RARE) 0.840. 1V Et, BLA. Then the effective value of control voltage is greater than 1.0401, the notor starts Up: when the effective value of control voltage is greater than 96:40. 1V, the rotor runs at the full speed; when the fan is running, if the effective value cf control voltage is lorer than 0,840.1, the eotor stops. 6.2 Kiewh/Soft start HLURB, AMS B RA, Lomb at em ANE. The notor start at low speed after 25 seconds running to full speed, to reduce current surges being dram to the porer supply 6.3 fR¥"/Protection PLR RE ATOR RRR RRR. (Re AR 5 LMR eS. This motor with locked-rotor protection, current limited, over-temperature protected electronics, line under-voltage and over-voltage lockout protection. 7.0 SMBER/Quality requests MRR AG & feb ME /Qual ity requestsaccord with FANS-TECH standard 8. OfMAEAIIR/ Packaging and marks 8. 1493¢/Packaging BRLAAREORS MEM ARABS MED ASR, The packaging has to be well dimension and structure, so that the fans for on normal transport could not be damaged. 8.2 bRUY/Marks PEE BA. PME RR. RTA. Markings: None of manutactore:, type of fan, date of manufacture, weight, Size ete, 9.0 ftft/Other requirements on accessory 9.1 $IAMI/ Inlet cones OR/ Yes, OA/ No, MARI ALA/ For Salers’ request. ‘9, 20496/Scroll housing (O#i/YES, WH /NO) 9. 3HERPEBOR/Annectent parts 341K B/ Linker (O#/Yes. i8F /terminal (O#f/Yes. 9. 4 FANS~TECH #%/ Logo FANS-TECH OB/ Yes, MIRIH/ No 9.5 HEMESIR/Nameplate drawing MR AAASE AR | 4 SC250E5-AGT-02 230V~ 50/60He 1.384 1868 (eal ) 6 | 2900r/ain Tad BAS SEF le | PARE EAR mst #i/No), 48 Jy model: 45/No) , W045 35 /model : Page 7 of 8 Pa Sf Fans-tech Product specification ‘Basi Narning: 1 BL. SRBL aCe A Ae A, RTT AT A The fan and motor must be used within the prescribed scope of temperature and hua-dity otherwise it will cause an unexpected damage. 2 ADAGE AE ER RAR AP, SIRS LR Provide the right voltage according to the nameplate otherwise it will damage the product. 3 NALA TAREE Has, AAA TER AN a A, ARR PTE CA, BAAR HEA AR AT Bic LE. Wiring depends on the wiring diagram and please connect the earth ground if required. we don’ t suggest to use the extension cord . Any wrong connection may cause the damage of the fan . 4 EAGAN IR, ABDUL OE AEs RIE H.-C CO AE TT A PLIERS ERK Be careful when moving the fan and do not take the blades as a handle because it will cause the distortion and chatter, SOTA EAR BER IDL, YS DA EAT A SLE, EMAL TRL HL BL Connect the thermostat if required otherwise it would damage the motor because of the over temperature. 6 MRR AG RATER KE, ASM MAHL. The length of the mounting scress shall not exceed the requirenent, otherwise the fan will be damaged 7 BARAT, CRRA, BAS AOR, PHRLME SIE e+ lee. Do not disassemble the fan arbi-rarily. It may hurt the capacity of water tightness and dynamic balance or cause other serious problems. BALAN SR as IC A OP LICE PA The over current protector is necessary in case the damage from the over current. 9 HRCA ALO Sey Beh FEA A YER AC Be LL A Install the fan as required , any other install ing direction would affect the service life of the product. 10 SPIRAL AGRA AE et BA, ‘The fan with inlet ring should be installed follow the requirements or it will affect the performance. TAY T AAP ZBL, FE PTR ELIMI EOR AN TEENA. AREAL O BY ARR Users should use the standard cable when install the fan other wise it will affect the water tightness. 12 FADLIR SESE LASER ASL mt AIH RASS. AAS SJL AS. The fan should keep away from the children especially the blade and electric parts . And the children are not allowed to operate the fan alone. AOL EASA PTABL, RRR NLRB AAA, RASA AE. AY Please be informed that we are not responsible for any damage or accidents caused by violating above rules to install and operate the fan. Page 8 of 8

You might also like