Professional Documents
Culture Documents
Minimum Requirements:
Processor 400 MHz
Memory 256 Mb
Hard Disk Space 280 Mb
Display 800 x 600 256 colors
.NET Framework 2.0
Internet Explorer 5.0
Setup
Set the ‘PC RS422’ switch on the first AD8HR to the ‘PC’ position.
Using a 9-pin null modem cable, connect the RS-232 Serial port of your PC to
the 9-pin PC connection on the first AD8HR. Using Yamaha suggested 9-pin
cables, daisy chain the remaining AD8HRs .
Null Modem
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
1
88.2kHz
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
2
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
88.2kHz
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
.
.
.
.
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
88.2kHz
255
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
Optional Setup
This optional setup provides maximum convenience and flexibility by
utilizing the LightViper 4832 Fiber Optic Transport System. The 4832
passes both 32 channels of the AES3 digital outputs from 4 AD8HRs and
the RS-232 control signal all on one fiber optic cable. For more information
about the benefits of the LightViper Fiber Optic Transport Systems visit
http://lightviper.com.
Audio to Console
MD-3
RS-232 MIDI RS-422
SYNC
Sends S1-S8 ANALOG Sends S17-S24 Returns R1-R8 Returns R1-R8 DIGITAL AES3 Sends S1-S16 Control 5x20mm 1 Amp Slo-Blo
Fiber Cable
VIS-4832 (Stage)
90-260 VAC 50-60 Hz
Ethernet Split Split Primary
S W
CLK CLK
OUT OUT
Sends S17-S32
ANALOG
SYNC
Returns R1-R8 Returns R1-R8 DIGITAL AES3 Sends S1-S16 Control 5x20mm 1 Amp Slo-Blo
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
88.2kHz -18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
RS-232 MIDI RS-422 WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
88.2kHz
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
96kHz
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
10
88.2kHz +48V +48V +48V +48V +48V +48V +48V +48V
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
1 EVEN
-6
2 EVEN
-6
3 EVEN
-6
4 EVEN
-6
5 EVEN
-6
6 EVEN
-6
7 EVEN
-6
8 EVEN
-6
+48V POWER
96kHz
-12 -12 -12 -12 -12 -12 -12 -12
+48V +48V +48V +48V +48V +48V +48V +48V
10
88.2kHz
-18 -18 -18 -18 -18 -18 -18 -18
48kHz HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30 HPF -30
44.1kHz -48 -48 -48 -48 -48 -48 -48 -48 HPF
WORD CLOCK IN
+48V
DIGITAL OUT A dB MASTER
OFF ON
Controls
Master Controls
ID: A drop down list used to select from all available Preamps. The list
contains the Device ID and the user assigned name for that
particular preamp.
Preamp Name: Directly below the ID list is the name of the current preamp. This can
be used to provide a clear identification of each preamp module.
Clock Source: Selects and displays the current clock frequency and source of the
selected preamp.
Enable Meters: Checking this box enables real time monitoring of all 8 channels of
the current preamp.
Panel Lock: Checking this box locks the front panel and disables local control of
the selected preamp.
48V Master: This control is for display only. A check indicates that the hard switch
for the “+48V MASTER” on the selected preamp is engaged.
LED Brightness: Sliding this control adjusts the brightness of the LED display on the
selected preamp.
Channel Controls
48V: Indicates and changes the 48V phantom power status of the
channel.
HPF: Indicates and changes the HPF status of the channel.
HPF Freq: Indicates and selects the HPF roll off frequency of the High Pass
Filter of the channel.
Meter: Indicates the signal level of the channel if the “Enable Meters” check
box is selected.
Gain Slider: Adjust the Gain Slider to the desired gain level. A numerical
equivalent of the gain level displays directly below the slider.
Trim: Indicates and selects the Gain Trim of the channel.
Channel Name: This field allows 8 characters of descriptive test for the channel.
Menus