SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...

\FB145 - <offline> 03/16/2005 16:44:24

FB145 - <offline>
"4th/5th axes"
Name: Family:
Author: Version: 0.1
Block version: 2
Time stamp Code: 2005/03/15 19:35:12Χ΋
Interface: 2003/05/27 19:17:56Χ΋
Lengths (block/logic/data): 00662 00458 00000

Address Declaration Name Type Initial value Comment


in
out
in_out
0.0 stat Axis4_unclamp BOOL FALSE 4th axis index table unclamp signal
0.1 stat Axis4_clamp BOOL FALSE 4th axis index table clamp signal
0.2 stat Axis5_unclamp BOOL FALSE
0.3 stat Axis5_clamp BOOL FALSE
temp

Block: FB145 4th/5th axes

Rev. 2002-4-23 : YSNC

1: M230,M231: 4th axis index table clamp/unclamp


2: M240,M241: 5th axis index table clamp/unclamp
3: M80,M81,M82,M83: Air limitter
Dummy signal should be fixed!!! T.K

Page 1..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 1 4th axis unclamp signal

( M231S or PLC-MD or (4th-axis-selected & Manual & /PLC-MD) )


& /M230S & MRDY ===> Unclamp

DB76.DBX17 DB76.DBX17 #Axis4_unc


.7 .6 M3.0 lamp

DB120.DBX2
47.6

DB124.DBX1 DB82.DBX30 DB120.DBX2


.0 .0 47.7

#Axis4_unc #Axis4_cla
lamp mp

Symbol information
DB76.DBX17.7 "MDECODE".M231 M231 DECODE
DB82.DBX30.0 "CMM_PLC".CMM_OUT.base_sig.main_mode_mill.manual
DB76.DBX17.6 "MDECODE".M230 M230 DECODE
M3.0 MReady Machine Ready (w/o timer)

Network: 2 4th axis clamp signal

M230S & /PLC-MD & /M231S & MRDY ===> Clamp

DB76.DBX17 DB120.DBX2 DB76.DBX17 #Axis4_cla


.6 47.6 .7 M3.0 mp

#Axis4_unc #Axis4_cla
lamp mp

Symbol information
DB76.DBX17.6 "MDECODE".M230 M230 DECODE
DB76.DBX17.7 "MDECODE".M231 M231 DECODE
M3.0 MReady Machine Ready (w/o timer)

Page 2..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 3 4th axis clamp

#Axis4_unc #Axis4_cla T64


lamp mp S_ODT Q7.6
S Q

DB120.DBW8
2 TV BI

R BCD

Symbol information
Q7.6 4EX.CLS 4Index Table Clamp CMD.

Network: 4 4th axis clamp FIN signal

M230 is cleared, when I13.2 is on or PLC-MD is on.

#Axis4_cla T43 DB76.DBX17 DB76.DBX17


I13.2 mp S_ODT .6 .6
S Q R

DB120.DBW6
6 TV BI

R BCD
DB120.DBX2
47.6

Symbol information
I13.2 4T.CLCNF 4axis Index Table Clamp SQ
DB76.DBX17.6 "MDECODE".M230 M230 DECODE

Page 3..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 5 4th axis unclamp FIN signal

M231 is cleared, when I13.3 is on or PLC-MD is on.

#Axis4_unc T44 DB76.DBX17 DB76.DBX17


I13.3 lamp S_ODT .7 .7
S Q R
DB120.DBX2 DB120.DBW6
49.5 8 TV BI

R BCD
DB120.DBX2
47.6

Symbol information
I13.3 4T.UCLCNF 4axis Index Table Unclamp SQ
DB76.DBX17.7 "MDECODE".M231 M231 DECODE

Network: 6 5th axis clamp/unclamp doorsill

Page 4..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 7 5th axis unclamp signal

( M241S or PLC-MD or (5th-axis-selected & Manual & /PLC-MD) )


& /M240S & MRDY ===> Unclamp

DB76.DBX19 DB76.DBX19 #Axis5_unc


.1 .0 M3.0 lamp

DB120.DBX2
45.6

DB124.DBX1 DB82.DBX30 DB120.DBX2


.1 .0 45.7

#Axis5_unc #Axis5_cla
lamp mp

Symbol information
DB76.DBX19.1 "MDECODE".M241 M241 DECODE
DB82.DBX30.0 "CMM_PLC".CMM_OUT.base_sig.main_mode_mill.manual
DB76.DBX19.0 "MDECODE".M240 M240 DECODE
M3.0 MReady Machine Ready (w/o timer)

Network: 8 5th axis clamp signal

M230S & /PLC-MD & /M231S & MRDY ===> Clamp

DB76.DBX19 DB120.DBX2 DB76.DBX19 #Axis5_cla


.0 45.6 .1 M3.0 mp

#Axis5_unc #Axis5_cla
lamp mp

Symbol information
DB76.DBX19.0 "MDECODE".M240 M240 DECODE
DB76.DBX19.1 "MDECODE".M241 M241 DECODE
M3.0 MReady Machine Ready (w/o timer)

Page 5..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 9 5th axis clamp

#Axis5_unc #Axis5_cla T65


lamp mp S_ODT Q7.7
S Q

DB120.DBW8
4 TV BI

R BCD

Symbol information
Q7.7 5EX.CLS 5Index Table Clamp CMD.

Network: 10 5th axis clamp FIN signal

M230 is cleared, when I13.5 is on or PLC-MD is on.

#Axis5_cla T62 DB76.DBX19 DB76.DBX19


I13.5 mp S_ODT .0 .0
S Q R

DB120.DBW7
8 TV BI

R BCD
DB120.DBX2
45.6

Symbol information
I13.5 5T.CLCNF 5axis Index Table Clamp SQ
DB76.DBX19.0 "MDECODE".M240 M240 DECODE

Page 6..
SIMATIC N3883002\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB145 - <offline> 03/16/2005 16:44:24

Network: 11 5th axis unclamp FIN signal

M231 is cleared, when I13.6 is on or PLC-MD is on.

#Axis5_unc T63 DB76.DBX19 DB76.DBX19


I13.6 lamp S_ODT .1 .1
S Q R
DB120.DBX2 DB120.DBW8
50.2 0 TV BI

R BCD
DB120.DBX2
45.6

Symbol information
I13.6 5T.UCLCNF 5axis Index Table Unclamp SQ
DB76.DBX19.1 "MDECODE".M241 M241 DECODE

Page 7