You are on page 1of 1

BRABENDER® Plastogram

PLASTI-CORDER and Mixer Measuring Head


Fusion Behaviour / Version 4.2.8
Test Conditions
Order :1 Speed : 50 1/min
Operator : Nadeem Mixer Temp. : 40 °C
Date : 1/1/2002 00:39 Start Temp. : 39 °C
Drive Unit : Lab-Station Meas. Range : 50 Nm
Mixer : W 50 EHT - 3 Zones Damping : 1
Loading Chute : Manual + 5 kg Test Time : 16.00 min
Sample : NBR Sample Mass : 48.0 g
Additive : Gelatin Code Number : 15

50 70

45 60

40 50

35 40

Temp.(Stock) [°C]
30 30
Torque [Nm]

25 20

20 10

15 0
t

10 -10

5 -20
A BX
G E

0 -30
00:00 06:00 12:00 18:00 24:00 30:00
Time [HH:MM:SS]
Torque Temp.(Stock)

Time
Name Torque [Nm] Stock Temp. [°C]
[HH:MM:SS]
Loading Peak A 00:00:58 11.4 46
Minimum B 00:01:52 7.9 60
Inflection Point G 00:02:02 8.7 60
Maximum X 00:02:02 8.7 60
End E 00:15:24 4.1 63

Integration / Energy
Loading Peak to Minimum A-B 2.6 [kNm]
Minimum to Maximum B-X 0.6 [kNm]
Maximum to End X-E 15.3 [kNm]
Loading Peak to Maximum A-X 3.2 [kNm]
Loading Peak to End (W) A-E 18.4 [kNm]
Specific Energy(W/Sample Mass) 383.8 [kNm/kg]
Gelation Area above B B-X 0.2 [kNm]

Results
Fusion Time t A-X 00:01:04 [HH:MM:SS]
Gelation Speed v -19.8 [Nm/min]

Page : 1 File : Gelatin F2B2