251. In every kitchen, family room, living room, parlor, bedroom or similar rooms of area of
dwelling units, receptacle outlets shall be installed so that no point along the floor line any
wall space is more than ____ measured horizontally from an outlet in that space.
A. 2,000 mm
B. 1,800 mm
C. 1,900 mm
D. 2,100 mm
View Answer:
Answer: Option B
Solution:
252. The path to ground from circuits equipment and metal enclosures for conductors shall
D. all of these
View Answer:
Answer: Option D
Solution:
Where the voltage between conductors does not exceed 300 V and the roof has a slope of
not less than 100 mm in 300 mm, the clearance can be reduced to
A. 500 mm
B. 800 mm
C. 1000 mm
2/19
D. 900 mm
View Answer:
Answer: Option C
Solution:
The uses of non-metallic extensions are NOT allowed in all but one of the following. Which
one is this?
A. As an aerial cable
View Answer:
Answer: Option C
Solution:
What is the minimum horizontal clearance for open conductors from windows, doors,
porches, fire escapes or similar location?
A. 1800 mm
B. 1500 mm
C. 1200 mm
D. 1000 mm
View Answer:
Answer: Option D
Solution:
A. 75°C
3/19
B. 50°C
C. 60°C
D. 90°C
View Answer:
Answer: Option C
Solution:
Concealed knob and tube wiring conductors shall be rigidly supported on knobs not more
than a certain minimum distance apart. What is this distance?
A. 2,000 mm
B. 1,500 mm
C. 1,300 mm
D. 2,500 mm
View Answer:
Answer: Option C
Solution:
In the installation of power resistors, a thermal barrier shall be required if the space between
the resistors and any combustible material is less than ______ mm. What is this minimum
clearance?
A. 150 mm
B. 300 mm
C. 200 mm
D. 250 mm
View Answer:
Answer: Option B
Solution:
4/19
259. RME Board October 1995
In estimating the loading of a branch circuit, what loading shall be used for each receptacle?
A. 160 volt-ampere
B. 120 volt-ampere
C. 180 volt-ampere
D. 150 volt-ampere
View Answer:
Answer: Option C
Solution:
Where the conduits enter a switchboard at the bottom, a sufficient space shall be provided to
permit installation of the conductors in the enclosure. The minimum spacing between the
bottom of the enclosure and the non-insulated bus bar shall be ________.
A. 155 mm
B. 300 mm
C. 255 mm
D. 200 mm
View Answer:
Answer: Option C
Solution:
261. What is the minimum vertical, horizontal or diagonal clearance for open conductors from
signs, chimneys, radio and televisions, antennas, tanks, or other non-building structure?
A. 1000 mm
B. 1500 mm
C. 1800 mm
D. 1200 mm
View Answer:
5/19
Answer: Option A
Solution:
262. Contact device installed at the outlet for the connection of a single attachment plug.
A. Junction box
B. Reactor
C. Rosette
D. Receptacle
View Answer:
Answer: Option D
Solution:
With respect to the safety value of the insulation on electrical maintenance tools, it can be
said properly that
View Answer:
Answer: Option C
Solution:
264. For the range of 8.75 kW or more in rating, the minimum branch circuit rating shall be
A. 30 A
B. 40 A
C. 50 A
D. 60 A
View Answer:
6/19
Answer: Option B
Solution:
265. Service heads and goosenecks in service entrance cable shall be ____ point of
attachment of the service drop to the building.
A. above the
B. below the
View Answer:
Answer: Option A
Solution:
266. A disruptive discharge around or over the surface of a solid or liquid insulator.
A. Flashover
B. Sparkover
C. Corona
D. Surge
View Answer:
Answer: Option A
Solution:
267. The minimum size of service lateral conductors using copper wires shall be _____.
A. 5.5 mm2
B. 3.5 mm2
C. 8.0 mm2
D. 2.0 mm2
View Answer:
Answer: Option A
7/19
Solution:
268. Plug fuses shall not be installed in circuits exceeding ____ between conductors.
A. 125 V
B. 250 V
C. 300 V
D. 150 V
View Answer:
Answer: Option B
Solution:
A continuous electrical load is one where the maximum current is expected to continue for a
minimum duration of time. What is this minimum duration of time?
A. 1 hour
B. 4 hour
C. 3 hour
D. 2 hour
View Answer:
Answer: Option C
Solution:
270. Direct buried conductors and cables emerging from the ground shall be protected by
enclosures or raceways extending from the minimum cover distance required to a point ____
above finished grade.
A. 2,000 mm
B. 2,500 mm
C. 2,400 mm
D. 3,000 mm
View Answer:
8/19
Answer: Option C
Solution:
271. For installations to supply only limited loads of a single branch circuit, service entrance
conductors shall NOT be smaller than ____ hard drawn copper.
A. 3.5 mm2
B. 8.0 mm2
C. 5.5 mm2
D. 14.0 mm2
View Answer:
Answer: Option A
Solution:
A. Surge Arrester
B. Lightning rod
C. Ground terminal
D. Air terminal
View Answer:
Answer: Option D
Solution:
273. Where no standard electrical equipment of the exact size or rating required is available,
____ maybe used.
D. none of these
View Answer:
Answer: Option B
9/19
Solution:
The minimum size of service drop copper conductors allowed by the Philippine Electrical
Code is one of the following. Which is the size?
A. 3.5 mm2
B. 5.5 mm2
C. 2.0 mm2
D. 8.0 mm2
View Answer:
Answer: Option D
Solution:
275. Entrances to rooms and other guarded locations containing exposed energized parts
shall be marked with a ______.
A. welcome sign
B. no entry sign
C. warning sign
D. all of these
View Answer:
Answer: Option C
Solution:
276. Appliance outlets installed in a dwelling unit for specific appliances, such as laundry
equipment, shall be installed within ____ of the intended location of the appliance.
A. 1,800 mm
B. 1,500 mm
C. 2,000 mm
D. 1,000 mm
View Answer:
10/19
Answer: Option A
Solution:
A. 20 A
B. 15 A
C. 12 A
D. 16 A
View Answer:
Answer: Option D
Solution:
278. For warehouses or storage, a general lighting load of _____ shall never be used.
A. 2 VA/m2
B. 4 VA/m2
C. 8 VA/m2
D. 10 VA/m2
View Answer:
Answer: Option A
Solution:
A. 500 VA
B. 600 VA
C. 660 VA
D. 550 VA
View Answer:
Answer: Option B
Solution:
11/19
280. RME Board October 1996
When fastening an outlet to a brick wall, the electrician should use no one of the following.
Which one is this?
A. Expansion bolts
B. Toggle bolts
C. Temporary nail
View Answer:
Answer: Option A
Solution:
A. Air terminal
B. Counterpoise
C. Surge Arrester
D. Ground terminal
View Answer:
Answer: Option D
Solution:
282. Open conductors passing over public streets, alleys, roads, parking areas subject to
truck traffic shall maintain a vertical height _____ from finished grade.
A. 3,700 mm
B. 4,600 mm
C. 5,500 mm
D. 3,100 mm
View Answer:
Answer: Option C
Solution:
12/19
283. Using copper, the minimum size of service entrance conductors shall be _____.
A. 14.0 mm2
B. 8.0 mm2
C. 5.5 mm2
D. 3.5 mm2
View Answer:
Answer: Option B
Solution:
When testing the insulation integrity of a new or old electrical wiring installation circuit of 5.5
mm2 conductors, the Code specifies a minimum insulation resistance of what value?
A. 1,000,000 ohms
B. 250,000 ohms
C. 500,00 ohms
D. 100,00 ohms
View Answer:
Answer: Option B
Solution:
B. No-load test
D. Ampacity test
View Answer:
Answer: Option C
Solution:
13/19
286. For four to six conductors in a conduit, the derating factor for the conductor ampacity is
____.
A. 70%
B. 90%
C. 80%
D. 60%
View Answer:
Answer: Option C
Solution:
When soldering two copper surfaces together, they should be kept clean while heating by
View Answer:
Answer: Option D
Solution:
288. Circuit of a voltage of 600 V or less in a rigid metal conduit or in a rigid metal conduit or
in rigid non-metallic conduit approved for direct burial and placed under driveway and
parking areas of a one or two family dwelling units, shall have minimum cover distance of
____.
A. 300 mm
B. 150 mm
C. 460 mm
D. 600 mm
View Answer:
14/19
Answer: Option C
Solution:
289. Plate electrodes of non ferrous metal shall be at least ____ in thickness.
A. 1.2 mm
B. 1.4 mm
C. 1.5 mm
D. 1.8 mm
View Answer:
Answer: Option C
Solution:
290. Conductors are selected at not less than ____ of nameplate rating of the water heater.
A. 125%
B. 100%
C. 120%
D. 130%
View Answer:
Answer: Option A
Solution:
291. The Philippine Electrical Code requires at no electrical installation, alteration or addition
shall be connected or reconnected to any electrical power supply without _____.
B. a certificate of inspection
C. an electrical permit
D. a certificate of completion
View Answer:
Answer: Option B
15/19
Solution:
A. 100 A
B. 150 A
C. 200 A
D. 300 A
View Answer:
Answer: Option C
Solution:
In the general layout of motors and power outlets not exceeding a total of ____ maybe
including in the lighting layout provided such inclusion will not make the reading,
interpretation and or checking of the said plan difficult.
A. 8
B. 10
C. 12
D. 6
View Answer:
Answer: Option B
Solution:
294. Direct grade level access is defined as being located not more than ____ above grade
level and being readily accessible.
A. 2,000 mm
B. 1,500 mm
C. 1,800 mm
D. 2,500 mm
View Answer:
16/19
Answer: Option A
Solution:
295. For the armories and auditorium, the general lighting load shall be ____ VA/m².
A. 8
B. 12
C. 10
D. 16
View Answer:
Answer: Option A
Solution:
Before the ammeter is disconnected from an energized current transformer circuit, one of the
procedures should be followed. Which is the one?
View Answer:
Answer: Option D
Solution:
297. Power conductors on the poles, below communication conductors shall maintain a
spacing distance of _____.
A. 760 mm
B. 600 mm
C. 800 mm
D. 540 mm
17/19
View Answer:
Answer: Option A
Solution:
298. It is the intent of the PEC that factory-installed internal wiring or the construction of the
equipment need not be inspected at the time of installation of the equipment EXCEPT
D. all of these
View Answer:
Answer: Option C
Solution:
A. mils
B. circular mils
C. square millimeters
View Answer:
Answer: Option C
Solution:
300. Mandatory rules of the PEC are characterized by the use of the word ____.
A. shall
B. should
C. both A and B
D. neither A and B
View Answer:
Answer: Option A
18/19
Solution:
Following is the list of practice exam test questions in this brand new series:
Subscribe
Prev Article Next Article
19/19