You are on page 1of 2
Zertifikat Certificate Zertifikat Nr. Certificate No. Blatt Page R 60017160 ooo1 Thr Zeichen Client Reference Unser Zeichen Our Reference Aussteliangsdatum Date of Tse 0001-- 21122451 001 14.02.2007 "man Genehmigungsinhaber License Holder Fertigungsstatte Manufacturing Plant Multi-Contact AG Basel Multi-Contact AG Basel Stockbrunnenrain 8 Stockbrunnenrain 8 4123 Allschwil 1 4123 Allschwil 1 Schweiz Schweiz nach Tested acc. (0 DIN V VDE V 0126-3/12.06 ‘Textifiziertes Produkt (Geriiteidentifikation) Certified Product (Product Identification) Steckverbinder (connector for photovoltaic systems) Designation: PV-KST3X / PV-KBT3X Rated voltage: De 1000V Rated current: 20A (90°C ; 2,0 - 4,0mm*) 30A (90°C ; 6, 0mm?) Ambient temperature range: -40 to +90°C Upper limit temperature: 105°C Moisture protection: IP 67 (1m ; 30min) Application class: A Hint: Only suitable for fixed wiring. X=I, II, /6IIA, 111 , /6I1I for the connectable cross section from 2,0 - 6,0 mm? and outer cable diameter from 3,2 - 9,0 mm. ansere Pris und Ze ranang cugrande ion den og. dfodennen, de Hering wird terval Cena bed on our Testing ond Ceifcation Regulation. The prodct ‘meioned reguremens. the production 1 ste to uvelance ‘TUV Rheinland Product Safety GmbH, Am Grauen Stein, D-51105 Kiln Tel: (+4928 06 - 13.71 ermal’ cer-validiy@defuv.com Fax: (249/220)8 06 © 39 38 hupliwww.tuy.comisfery Prose AX Toveheiniana” “TOV Reiland Product Safely GmbH: 51101 Kain F-Langenecait Your client No.: 337517 ta Multi-Contact AG Fax visgzraoese 67 Herr Markus Kohler Mal ins.f91ebde com ‘Stockbrunnenrain 8 euslomer tenn cana ot product safety and-aally CH - 4123, Allschwil Phone 49221806 400, ‘Cologne, 16. November 2007, Dear Mr. Kohler, Hereby we confirm that the PV-Connector PV-KST3... ; PV-KBT3...; PV- KST4... and PV-KBT4... were tested at TUV Rheinland Product Safety GmbH. The presented PV-connectors were tested in accordance with DIN V VDE V 0126-3:2006 in test report no.: 21122451-001 and 21120907-004 or rather certified in certificate no.: R60017160-0001 and R60017180-0001. Furthermore we confirm that the above-mentioned PV-connectors comply with the relevant requirements of IEC 61730-1:2004, which are part of DIN V VDE V 0126-3: 2006. Sincerely, “TOV Reiniand - Proauet Sty Gat —— (Gli immetine My, Tek s49 103 s1112 Fax Sie teo cutee LA. Frank Langenscheidt TA. Guido Volb Wie we caatety ‘St der Gesetsenat ‘am Grauen Sten rs Kan CGeschattonung DipLng "MeaetJungntsen Dil. wtsch. ng Hane Hermann Jing USTIO Ne DE 811035400

You might also like