Alyssa Monique Gil APPLICATION OF DESIGN AND INVESTIGATION Mark Daniel Narbay Sophia Ysabel Necor Kyle Robert Pasquin Paul Justin Santos
Line loads due to CHB walls
CHB walls thickness = 100mm and 200mm Floor to Floor Height = 3.50m
Density of common building materials
CHB 200 mm thk 3.45 KN/m² 100 mm thk 2.20KN/m²
The line loads due to the 100mm thk CHB walls
= Wall Height x Density = 3.50m x 2.2 KN/m² = 7.700 KN/m
The line loads due to the 200mm thk CHB walls
= Wall Height x Density = 3.50m x 3.45 KN/m² = 12.075 KN/m
PROJECT ASSIGNMENT 2 | EEVEELUTION
Area loads for Live Loads
Live Load (for residential) = 1.92 KPa
Area loads for Slabs
Conversion to KN/m³ 2400 x 9.81/1000 = 23.544 KN/m³
Slab Thickness = 150mm
Area load from the slab’s weight = 23.544 KN/m³ x 0.15mm = 3.532 KPa + 0.3 KPa Area Load from the slab's weight = 3.832 KPa
PROJECT ASSIGNMENT 2 | EEVEELUTION
Area loads for Floor Finishes 600mm x 600mm x 15mm thk Ceramic Tiles 300mm x 600mm x 12mm thk Non-Skid Ceramic Tiles 200mm x 1200mm x 20mm thk Wood Planks