Line loads due to CHB walls


CHB walls thickness = 100mm and 200mm
Floor to Floor Height = 3.50m

Density of common building materials


CHB
200 mm thk 3.45 KN/m²
100 mm thk 2.20KN/m²

The line loads due to the 100mm thk CHB walls


= Wall Height x Density
= 3.50m x 2.2 KN/m²
= 7.700 KN/m

The line loads due to the 200mm thk CHB walls


= Wall Height x Density
= 3.50m x 3.45 KN/m²
= 12.075 KN/m

PROJECT ASSIGNMENT 2 | EEVEELUTION


Area loads for Live Loads

Live Load (for residential) = 1.92 KPa

Area loads for Slabs

Conversion to KN/m³
2400 x 9.81/1000 = 23.544 KN/m³

Slab Thickness = 150mm


Area load from the slab’s weight = 23.544 KN/m³ x 0.15mm
= 3.532 KPa + 0.3 KPa
Area Load from the slab's weight = 3.832 KPa

PROJECT ASSIGNMENT 2 | EEVEELUTION


Area loads for Floor Finishes
600mm x 600mm x 15mm thk Ceramic Tiles
300mm x 600mm x 12mm thk Non-Skid Ceramic Tiles
200mm x 1200mm x 20mm thk Wood Planks

For 15mm thk ceramic tiles on a 10mm mortar bed


Area Load (ceramic tiles) = 0.021 KPa/mm (15mm) +
0.0275 KPa/mm (10mm)
= 0.315 + 0.275
= 0.590 KPa

For 12mm thk non-skid ceramic tiles on a 10mm mortar bed


Area Load (ceramic tiles) = 0.021 KPa/mm (12mm) +
0.0275 KPa/mm (10mm)
= 0.252 + 0.275
= 0.527 KPa

For 20mm thk hardwood planks on a 10mm mortar bed


Area Load (hardwood planks) = 0.0086 KPa/mm (20mm) +
0.0275 KPa/mm (10mm)
= .172 + 0.275
= 0.447 KPa