You are on page 1of 20

Since 1942

...a real breakthrough in sewer technology

Unique Features
• Readymade solution
• Exhaustive and complete range
• 90% Lighter than concrete manhole
• Robust design
• 100% Watertight
• Proven performance
• Minimum 50 years of service life
• Extensive saving in time and labour
• Minimal maintenance

Jeevan bhar ka saath...


The Supreme Industries Ltd., is an
acknowledged leader of India’s plastic industry.
It is credited with pioneering several path-
breaking products and has been a torchbearer
in the transition from conventional to advanced
plastic piping products in the country. Its
customer-centric approach fuels its research for
designing unmatched quality products to meet
the aspirations of its quality conscious
customers. The innovative product portfolio
offered by Supreme is extensive in range and
application and comprises variety of pipes and
vast spectrum of fittings totaling over 9000
diverse products.
We are now pleased to add many new sizes and
configurations of manholes to extend the
range to offer complete sewerage system
solution. This includes 800 mm and 1200 mm
size manholes in unique and innovative
designs and many additional configurations in
existing 600 mm size deep inspection
chambers and 1000 and 1200 mm size
manholes. Exhaustive range of innovative and
ready to use Ultra manholes in plastics with a
provision of a ladder is a real breakthrough in
sewer technology. A combination of strength
and elasticity, Ultra manholes is the result of our
extensive R & D which offers several advantages
over conventional concrete manholes. Its
versatile features have the potential to change
the face of sanitation, construction and
environment in the country that will enhance
the quality of life.

2
Unique Features
• Readymade solution - Ready to use 800 mm, leakage. Unlike conventional products, Nu-drain
1000 mm and 1200 mm size manholes with 574, sewer system installed with Ultra manholes is
600 or 640 mm size spacious opening for totally free from any infiltration and exhilaration;
entrance makes the job easy. hence the highest standard of hygiene is
maintained.
• Light in weight - 90% lighter than concrete
manholes that makes the handling and • Perfect hydraulic properties - Streamline
installation of manholes very easy and fast. design of the manhole and very smooth internal
Moreover, the installation can be done without surface greatly reduces the possibility of slime
any heavy equipment's. build-up which minimizes the risk of blockage.
• Robust design - Ultra manholes are designed to • Suitable for installation depths up to 6 m.
withstand heavy traffic loads up to 40 MT. They • Safe against floatation - Rib structure on the
are strong enough to withstand all types of static external surface and its overall design makes the
or dynamic loads such as soil loads, traffic loads manholes safe against floatation.
and the loads arising on account of soil
displacement and ground water pressure. • Provided with in-built ladder to facilitate easy
maintenance and cleaning.
• Strong and durable - Being in plastics, the
manholes are free from any corrosion or chemical • Provision of height adjustment - Height
reactiveness. Because of this and due to the adjustment of manhole is possible according to
robust design, the manholes are sufficiently the changes in the formation level of road to suit
strong and durable to offer a long and trouble the site requirements.
free service life. • An additional pipe connection to the manhole at
• 100% Water tight struc ture - All the different levels and at any angle is possible using
components of manholes are designed in such a simple and reliable 'in-situ' adapters.
way that there remains no possibility of any • Eco- friendly and cost effective.

Ultra Manhole
Inspection chambers and manholes are the important entry of man is essentially required, Supreme Ultra 800, 1000
components of the drainage or sewerage system. Inspection and 1200 mm size manholes can be used. These readymade,
chambers are used for inspecting sewer networks from the ready to use manholes offered by the company consists of a
surface level while manholes provide access to a person base, a shaft and a cone with suitable cover. In addition to the
inside the manhole for cleaning and maintenance activities. three piece design, a single piece cost effective design is also
These are used at the junction in sewer network or a straight offered for certain invert depths. These strong and sturdy
or bend configuration depending on the flow patterns or manholes are designed, manufactured and tested as per
even as water meter chambers. EN:13598 standards and are approved by MCGM.
Unlike conventional drainage systems, the entry of man
inside the manhole is almost eliminated in advanced plastic
sewer systems. Because of the mirror smooth inner surface of Fields of Application
these systems, the possibility of blockage is greatly reduced Ultra 800, Ultra1000 and Ultra1200 manholes are designed to
and hence the modern technology CCTV inspection cameras provide an easy access for inspection, cleaning and
for inspection and jet cleaners for cleaning and maintenance maintenance of private and public sewers up to 6 m invert
can be used. depth. Supreme Ultra manholes having robust design,
Most of the sewer maintenance requirements are fulfilled durability and flexibility are the best substitute to the
through Ultra 600 inspection chambers; however, where the conventional concrete and masonry manholes.

3
Water and Environment Protection
Supreme proving true to its title is very active in providing unique and innovative piping solutions for drainage,
sewerage, and waste water management in order to protect the water resources and the environment. We are the trail
blazers in introducing a complete Underground Drainage and Sewer System (UDSS) solution with readymade
inspection chambers and manholes. We introduced our Nu-drain UDSS ahead of time with a futuristic approach i.e.
12 years before; to provide excelling substitute to the age old conventional underground drainage products. Our R &
D in consultation with our reputed clientele have developed a host of new products to offer complete sewer system
solution in the best efficient manner. At present we have more than 500 products in our range to meet any project
requirement. We adjacently have the testing facility to test the product as per the EN standards. It is because of the
superior properties and multiple advantages the Supreme Nu-drain UDSS is now getting well accepted by the users
across the country.

Quality Control
Supreme prides itself in providing a
consistently high level of product quality
mainly based on the product design, raw
material, and the finished product quality.
Use of virgin raw material, from the reputed
suppliers together with specially designed
compounds guarantees the products
performance on long term basis. In order to
ensure the trouble-free performance of the
product, each lot of raw material, the
product quality at each stage of its
production, and bought out items undergo
a very strict quality control besides
maintaining continuous improvements in
the process. Different tests like type tests
and regular tests as prescribed in the EN
standards are rigorously carried out that
ensures the durability of the products on
long term basis.

Technical Support
Our coherent team of experts in technical
support provides the required technical
assistance in project design and installation.
Their thorough experience in the field helps
to get the right and customized solution to
each and every project requirement which
not only ensures trouble free product
performance but also helps to optimize the
project cost.

4
Product Range
Supreme offers an exhaustive range of manholes to meet the complete requirement of the sewerage system. Supreme Ultra
manholes are suitable up to 6 m invert depths. Recently introduced 800 mm size manhole is offered in single piece design, while
the 1000 mm and 1200 mm size manholes are offered in single piece as well as in three piece designs. Depending on the size or
type of Ultra manhole they are suitable to adopt the pipes from 110 mm to 600 mm sizes. Plain uPVC or PE pipes can be directly
connected to the manholes using rubber seal joints whereas; DWC pipes can be connected using DWC adopters.
The three piece design of the manhole have a base, shaft pipe and cone. The shaft pipes are supplied in 1m or shorter lengths,
which can be cut on site or can be joined with each other as per the invert depth requirement. The complete set of manhole with
an inbuilt ladder and the advanced design of corrugated shaft and cone with spacious entrance suffice all the functional
requirements.
Moreover, because of the compact and robust design, wide range, additional connection possibilities, appropriate cover
solution, and user friendly installation, the contractors and installers can be sure of a tight and durable system for every situation.

Three Piece Design


In a three piece design of the manhole, base, shaft and cone are the separate
components that are connected with each other on site using specially
designed rubber seals. The shafts are available in 1m or smaller lengths which
are required to be connected as per the invert depth requirements up to 6 m. In
this design, Installation and backfilling needs to be carried out simultaneously.

Single Piece Design


In most of the projects, the invert depth of the manhole is normally does not
exceed 3 m. For such applications, the use of a three piece manhole may not be
cost effective. Considering this fact we have introduced a lightweight yet
strong manhole in single piece design in 800 mm, 1000 mm and 1200 mm sizes.
In spite of being light in weight, these uniquely designed cost effective
products are strong enough to withstand all sorts of loads alike existing three
piece design manholes. This new design is very cost-effective due to weight
reduction and the elimination of rubber seals between the base, shaft, and
cone. Moreover, the single piece design together with lightweight structure
makes the installation convenient and fast.

Blind Base
In addition to the different standard flow profiles of the manhole base, we also
offer a blind base i.e. the base with only outlet provision and without any inlets.
These blind bases are made available in 600 mm and 1000 mm sizes and are
designed to offer non-standard flow configuration requirements. These are
supplied with the required or specified inlet(s) welded on the base in
customized form i.e. inlets at required angle to adopt any type or size of pipes
like uPVC/ PE plain pipes or the DWC pipes. This chamber and manhole is
offered with base, shaft pipe and cone in integral form as single piece design or
alternatively manhole base, shaft pipe(s) and cone separately to connect with
each other on site as three piece design.

5
600
The Ultra 600 deep inspection chamber consists of a base and inlet and outlet in 200, 250 and 315mm sizes and 90° bend
corrugated shaft. This Ultra 600 base provided with swivel with 200 mm inlet/outlet. These compact inspection
adopter have a 250 mm size inlet(s)/outlet. It is made chambers are cost-effective and suitable for all drainage,
available in 6 different flow configurations. The specially sewerage and storm water drainage applications.
designed swivel adopter allows free angular deflection of 7.5° These robust chambers are suitable for installation depths
from the centerline in each direction. This flexibility allows the from 0.8 to 5 m. The corrugated shaft provides excellent
adjustment of pipe connection in the trench to match the resistance to ground movement and heavy traffic loads. This
slope and alignment. In addition to the Ultra 600x250mm size strong and sturdy product is superior and helpful in many
inspection chambers, we have also introduced Ultra ways. Simple and reliable “in-situ” connections can be easily
600x200mm chambers without swivel adopter in 5 different made in the shaft to make additional connections.
flow profiles. Both Ultra 600x250 and Ultra 600x200 The adjustable telescopic adapter is also made available to
inspection chambers are provided with separate base and adjust the height and to provide a proper seating base for
shaft. GRP or SFRC frame and cover. Ultra 600 can be used with and
Besides these, we also offer Ultra 600 with an integral shaft. without a telescopic adopter.
This is made available in straight through configuration with

D
OD
ID
S1

D L
H I
I1
S
Ultra 600 x 200
Base with Separate Shaft L2
L1

Configurations D OD ID S S1 L L1 L2 I I1 H
Straight Through 965 - - 460 - 490
90° Bend 842 475 - - 550
90° LH Junction
200 729 676 115 200 961 478 835 520 420 555
90° RH Junction
LH & RH 90° Junction 956

Shaft pipe Shaft pipe- socketed


OD OD
ID OD ID I S H ID OD ID S I OD1 ID1 H
400 600 655 780
700 900 955 1080
1000 1200 1255 1380
H I H
672 600 200 1300 1500
672 600 125 722 675 1555 1680
1600 1800 I

1900 2100 1855 1980


S
S
2200 2400 ID1 2155 2280
OD1
2455 2580

Available flow configurations of Ultra 600 x 200 and Ultra 600 x 250 with Swivel adopter

Straight Through LH or RH 90° Bend LH 90° Junction RH 90° Junction LH & RH 90° Junction (Cross) LH or RH 45° Bend

Note : All dimensions unless specified are in mm.

6
600
Ultra 600 x 250
Base with Swivel Adopter
Configurations D ID S S1 L L1 L2 I H
Straight Through 900 - -
90° Bend 780 405 - 600
90° LH Junction
250 676 123 200 918 460 832 630 704
90° RH Junction
LH & RH 90° Junction -
45° Bend 821 875 600
ID L1

S1

H L D
S
D I

L L2

Ultra 600 x 200/250/315


Base with Integral Shaft
ID
Configuration D ID L I H
1135 1165
200 965
1735 1765
Straight 1000 1040
Through 250 1025
600 1600 1640 I H
1000 1040
315 1075
1600 1640
1195 1225
90°Bend 200 842
1795 1825 D

Ultra 600
Blind Base with Integral Shaft
ID
D (Inlet) D1 D2 D3 OD L1 L2 I L3
H ID
1225 1235
110 to 250 160 200 250 730 1175 1025 855 600
1825 1835

This blind base can be supplied with required


inlet(s)/outlet fitted with it to adopt uPVC/PE or DWC
H
pipes from 160 to 250 mm sizes at any angle. In OD
addition to the two invert variants given in the chart,
the base with separate shaft pipes in multiple
D3 D2 D1 I
numbers can be used for increased invert depths. For
shorter invert depths, it can also be supplied as per the L3
L2
project requirements. L1

Note : All dimensions unless specified are in mm.

7
600
Recently, we have introduced a 600 mm size multi-inlet main inlets up to 315 mm) by core cutting. Plain uPVC or PE
cost effective inspection chamber to meet the project pipes can be directly connected to the base using rubber
requirements where invert depths are less than 2.0 m. This seals whereas, for DWC pipes, DWC adopters are required.
inspection chamber is made available in single piece This cost-effective multi-inlet inspection chamber with
design i.e. base with shaft in integral form. It can be new shaft is made available in 5 invert depths and with
supplied with new 600mm size OD shaft as well as existing existing shaft in 2 invert depths, in 6 different flow
672 mm OD shaft. It is provided with integral outlets with configuration as per the below given charts. This
spigot ends from 160 to 315 mm and flat surface to adopt inspection chamber designed to meet all the functional
the connecting pipes (side inlets from 110 to 250 mm and requirements as per EN standard.

Ultra 600 Multi-inlet Inspection


with 600mm OD shaft

D (Side Inlet) D5 (Main Inlet) Outlet L1 L2 L3 L4 ID OD OD1 I H


OD
900 950 ID
110 to 250 110 to 315 D1-160 1100 1150
uPVC Pipe & uPVC Pipe & D2-200
150 to 250 150 to 300 1400 1250 1100 900 550 600 730 1400 1450
D3-250
DWC Pipe DWC Pipe D4-315 1600 1650
1900 1950
H
OD1
D5 (Main inlet)
D (Side inlet)

D5
I (Main inlet)
D4 D3 D2 D1

L4
L3
L2
L1

Ultra 600 Multi-inlet Inspection


with 672mm OD shaft
OD
D (Side Inlet) D5 (Main Inlet) Outlet L1 L2 L3 L4 ID OD OD1 I H ID

110 to 250 110 to 315 D1-160


uPVC Pipe & uPVC Pipe & D2-200 1200 1250
150 to 250 150 to 300 1400 1250 1100 900 600 672 730
D3-250 1800 1850
DWC Pipe DWC Pipe D4-315
H

OD1
D5 (Main inlet) D (Side inlet)
D5
(Main inlet)
D4 D3 D2 D1 I

L4
L3
L2
L1

Note : All dimensions unless specified are in mm.

8
800
Single Piece Design
• With integral base, shaft and cone
• Suitable for invert depths from 1.15 to 2.75 m
• Suitable to connect pipe sizes from 160 to 400 mm

Recently we have introduced 800 mm size manholes to meet the


sewer project requirements where invert depths are less than 3 m.
This manhole is made available in single piece design i.e. base, shaft
and cone in integral form. The manhole base is provided with flat
surface to adopt the connecting pipes by core cutting as per the size
of pipe from 160 to 400 mm. Plain uPVC or PE pipes can be directly
connected to the base using rubber seal joints whereas DWC pipes
up to 400 mm sizes can be connected using DWC adopters and
rubber seal joints. This cost-effective manhole is made available in 6
invert depths, in 6 flow configuration as given in the chart. Like Ultra
1000 and Ultra 1200, this manhole meets all the functional
requirements and EN test compliance.

D D1 D2 D3 L ID OD OD1 I H
160 to 400 1150 1190
OD
1450 1490
ID uPVC / HDPE pipe &
574/ 590/ 1750 1790
150 to 400 820 940
600 620 2150 2190
DWC pipe
2450 2490
(Inlet/outlet) 2750 2790

Available flow configurations

OD1

Straight Through LH 90° Junction RH 90° Junction

D to D3
(Inlet/Outlet)

LH or RH 90° Bend Two 90° Inlet Junction LH & RH 90° Junction (Cross)
L

Note : All dimensions unless specified are in mm.

9
1000
Three Piece Design
• With separate base, shaft and cone
• Suitable for invert depths up to 6 m
• Available in 7 different flow configurations

This Ultra 1000 manhole is provided in three piece design i.e. separate
base, shaft, and cone in 7 different flow configurations. The robust design
of the base, corrugated shaft and cone makes it extremely strong to
withstand all sorts of loads that the manhole has to withstand during
handling, transportation, installation and in use. It is available with and
without ladder.

Cone
Size ID OD OD1 ID1 S S1 I H
641 710 205 630 835
1000 x 600 1160 1111 200
574/600 590/620 230 900 1100
Shaft
OD
ID OD ID OD1 ID1 S
1102 1001 1170 1111 200
S1
Length (H) 500 600 800 1000 1100 1300
H I Invert depth (I) 300 400 600 800 900 1100
Base
Configurations D D1 D2 OD L I H
S Straight Through 250 250 1430 565 615
-
ID1 Straight Through
OD1
LH and RH 45° Junction
OD LH 45° Junction 315 315 250 1106 1376 555 600
ID
RH 45° Junction
Two 45° Inlet Junction
- 1250
LH or RH 45° Bend
H I
Available flow configurations

S
ID1
OD1
Straight Through LH and RH 45° Junction LH 45° Bend RH 45° Bend
OD

I
H D D2 D1

LH 45° Junction RH 45° Junction Two 45° Inlet Junction


L

Note : All dimensions unless specified are in mm.

10
1000
Single Piece Design
with corrugated Shaft
• Suitable for invert depths up to 2.33 m
• Available in 7 different flow configurations

This Ultra 1000 manhole in single piece design with corrugated shaft is
offered in 7 different flow configurations in different invert depths up
to 2.33 m. It is extremely strong to withstand all sorts of loads.

Ultra Straight Through Ultra Straight Through


1000 x 250 mm 1000 x 315 mm
Invert Depth H Invert Depth H
1330 1380 1200 1240
1630 1680 1500 1540
2030 2080 1700 1740
2330 2380 2000 2040
2200 2240

Available flow configurations

OD
ID

Ultra Three Inlet


LH and RH 45° Junction Two 45° Inlet Junction
1000 x 315 x 250 mm
Invert Depth H
1320 1365
1620 1665
1820 1865
2120 2165 RH 45° Bend LH 45° Bend

2320 2365

H OD1

RH 45° Junction LH 45° Junction

Note :- This manhole variant can be supplied in three piece design i.e.
base monolithic with 1.0 m length of shaft, separate socketed shaft(s)
and cone to meet the increased invert depth requirement up to 6 m .

D I D1 Dimensions
D2
Configurations D D1 D2 ID OD OD1 L
L Straight Through 250 250 - 1430
574/ 590/
Straight Through 315 315 - 1102 1377
600 620
Three Inlets 315 315 250 1388

Note : All dimensions unless specified are in mm.

11
1000
Single Piece Design
with non-corrugated Shaft
• Suitable for invert depths up to 3.43 m
• Available in 7 different flow configurations

This Ultra 1000 manhole in single piece design with non-corrugated


shaft is offered in 7 different flow configurations in different invert
depths up to 3.43 m. It is extremely strong to withstand all sorts of
loads.

Ultra Straight Through Ultra Straight Through


1000 x 250 mm 1000 x 315 mm
Invert Depth H Invert Depth H
2530 2580 2400 2440
2830 2880 2700 2740
3130 3180 3000 3040
3430 3480 3300 3340

OD
ID

LH and RH 45° Junction Two 45° Inlet Junction


Ultra Three Inlet
1000 x 315 x 250 mm
Invert Depth H
2520 2565
2820 2865
3120 3165 RH 45° Bend LH 45° Bend
3420 3465
OD1

RH 45° Junction LH 45° Junction

Dimensions
Configurations D D1 D2 ID OD OD1 L
I Straight Through 250 250 - 1430
D D1 574/ 590/
Straight Through 315 315 - 1172 1377
600 620
L Three Inlets 315 315 250 1388

Note : All dimensions unless specified are in mm.

12
1000
Single Piece Design
• Suitable for invert depths from 1.55 to 2.55 m with corrugated shaft
• Suitable for invert depths from 2.75 to 3.65 m with non-corrugated shaft
• Suitable for invert depths up to 6.0 m in three piece design
• Suitable to connect pipe sizes from 160 to 600 mm

This Ultra 1000 manhole is made available in single piece design i.e. base, shaft
and cone in integral form. The manhole base is provided with flat surface to adopt
the connecting sewer pipes by core cutting as per the size and type of pipe from
160 to 600 mm. 160 to 400 mm size uPVC/HDPE pipes can be directly connected
using rubber seals and to connect 150 to 400 mm size DWC pipes the manhole
base is supplied with rubber seal and adopters. The base with 500 and 600 mm
size inlet(s)/outlet are supplied with integrally welded DWC adaptors. This cost-
effective manhole is made available in 9 invert depths and it can be used for 6
different flow configuration requirements. Being in single piece design, the
OD rubber sealing rings required to connect manhole components are eliminated
ID
and total weight is also reduced as a result it is very cost effective. It meets all the
strength and functional requirements.

With Corrugated Shaft


H D D1 D2 D3 L ID OD OD1 I H
OD1
1555 1605
160 to 400
1855 1905
D to D3 uPVC / HDPE Pipe & 574/ 590/
(Inlet/Outlet) 1040 1300 2055 2105
150 to 600 DWC Pipe 600 620
2355 2405
I (Inlet/outlet)
2555 2605
L

OD
ID

With non-Corrugated Shaft


H
D D1 D2 D3 L ID OD OD1 I H
OD1
160 to 400 2755 2805
D to D3 uPVC / HDPE Pipe & 574/ 590/ 3055 3105
(Inlet/Outlet) 1040 1300
150 to 600 DWC Pipe 600 620 3355 3405
I (Inlet/outlet) 3655 3705
L

Available flow configurations

Straight Through LH 90° Junction RH 90° Junction LH or RH 90° Bend Two 90° Inlet Junction LH & RH 90° Junction (Cross)

Note : All dimensions unless specified are in mm.

13
1000
Blind Base-Single Piece Design
• Suitable for invert depths from 1.29 to 2.29 m with corrugated shaft
• Suitable for invert depths from 2.49 to 3.39 m with non-corrugated shaft
• Suitable for invert depths up to 6 m in three piece design
• Suitable to connect pipe sizes from 110 to 355 mm

To meet the non standard flow configuration requirements, this blind base with
integral shaft and cone in single piece design is the ideal solution. It is supplied
in customized form with required inlet(s) fitted on the base to adopt uPVC/PE or
DWC pipes at any angle up to 355 mm sizes as per the project requirements. This
robust design in single piece is very cost effective due to elimination of rubber
sealing rings and weight reduction.

OD
ID

Single piece design with corrugated shaft


D (Inlet) D1 D2 D3 L1 L2 L3 ID IOD OD1 H
1290 1330
110 1590 1630
to 574/ 590/
200 250 315 1637 1467 1258 1108 1790 1830
OD1 355 600 620
2090 2130
H
2290 2330

This manhole variant is available in 5 invert depths as per the details given in the table
I D1 D2 D3 with 110 to 355 mm size pipe inlet(s) at required angles. Manhole is supplied with the
L3 adaptors welded on the base as per the required configurations to adopt uPVC, PE or
L2
L1 DWC pipes using rubber seal joints.

OD
ID Single piece design with non-corrugated shaft
D (Inlet) D1 D2 D3 L1 L2 L3 ID IOD OD1 H
2490 2530
110
2790 2830
OD1 to 200 250 315 1637 1467 1258 574/ 590/ 1172
355 600 620 3090 3130
3390 3430
H
This manhole variant is available in 4 invert depths as given in the table above with 110
I D1 D2 D3 to 355 mm size pipe inlet(s) at various angles. Manhole is supplied with suitable
L3 adaptor(s) welded on the base as per the required configurations to adopt uPVC, PE or
L2
L1 DWC pipes using rubber seal joints.

(Outlet)

D (Inlet)
Three piece design up to 6 m invert depth
Blind base with inlet(s) at various angles fitted on the base, corrugated shafts in
socketed form and cone supplied separately is suitable for invert depths from 1.22 to
6 m.
Note : All dimensions unless specified are in mm.

14
1200
Three Piece Design
• With separate base, shaft and cone
• Suitable for invert depths up to 6 m
• Available in 7 different flow configurations

Ultra 1200 manholes are provided in three piece design i.e. separate base,
shaft, and cone in 7 different flow configurations. The robust design of the
base, corrugated shaft and cone makes it extremely strong to withstand all
sorts of loads that the manhole has to withstand during handling,
transportation, installation and in use. It is available with and without ladder.

Cone
Size ID OD OD1 ID1 S S1 I H
641 710 200 735 935
1200 x 600 1340 1282 200
600 620 230 1000 1200

Shaft
OD
OD ID OD1 ID1 S
ID
1302 1202 1366 1314 200
Length (H) 520 635 770 865 1000 1115 1345
Invert depth (I) 320 435 570 665 800 915 1145
H I

Base
Configurations D D1 D2 OD L I H In built
slope
S
Straight Through 1508 625 680 Nil
ID1
OD1 LH and RH 45° Junction
LH 45° Junction 315 315 315 1272 1548 565 640 1 in 50
OD
ID RH 45° Junction
Two 45° Inlet Junction
LH 45° Bend - 1450
RH 45° Bend
H I
Available flow configurations

ID1
OD1 Straight Through LH and RH 45° Junction LH 45° Bend RH 45° Bend Two 45° Inlet Junction
OD OD

I
H D D2 D1 H D I D1

L L LH 45° Junction RH 45° Junction

Note : All dimensions unless specified are in mm.

15
1200
Three Piece Design
• Suitable for invert depths up to 6 m in three piece design
• Suitable to connect pipe sizes from 160 to 600 mm

This three piece design manhole is available with base integral with a small length of
shaft, separate shaft(s) and cone. This manhole base is provided with flat surface to
adopt the connecting pipes by core cutting. Available in 6 flow configuration, it is
suitable for invert depths up to 6 m.

OD Available flow configurations

H
I

Straight Through LH 90° Junction RH 90° Junction


L

OD L I H
1160 1215
1302 1040 1500 1555
LH or RH 90° Bend Two 90° Inlet Junction LH & RH 90° Junction (Cross)
1985 2040

1200
Single Piece Design
• Suitable for invert depths from 1.55, 2.45 to 3.03 m with corrugated shaft
• Suitable to connect pipe sizes from 160 to 600 mm

Ultra 1200 manholes in single piece design can be used


OD
ID for 6 different flow configuration requirements. The
robust design of the base, corrugated shaft and cone
makes it extremely strong to withstand all sorts of loads.
The manhole base is provided with flat surfaces to
adopt the connecting inlet(s)/outlet pipes by core
cutting. Plain uPVC/HDPE pipes can be directly
connected using rubber seals whereas for DWC pipes,
OD1 DWC adopters are required . Base with 500/600 mm size
inlet(s)/outlet is supplied with integrally welded DWC
H
adaptors.
D D1 D2 D3 L ID
I OD OD1 H
D to D3 160 to 400 1555 1605
(Inlet/Outlet)
uPVC / HDPE pipe 2450 2500
& 150 to 600 1040 600 620 1300 2685 2735
I
DWC pipe 2800 2850
L
(Inlet/outlet) 3030 3080
Note : All dimensions unless specified are in mm.

16
Cone extension piece Cover Solution
OD
ID Manhole covers in different materials and load classes are
made available to complete the project requirements. Details
I
I1 H of these covers are given in the following table: -
I2
S GRP frame and cover
ID1
OD1 OD
H
Cone extension piece (590 OD) - This specially designed
ID
new extension piece can be used to increase the invert depth
OD1
of manhole having 574 mm size ID. Extension piece is made
available in 3 different invert depths to adjust the change in Load
road formation level up to 300 mm. Size Material class (MT) ID OD OD1 H
Plastic - 625 720 - 80
OD Ultra 600,
ID
Ultra 800, 10
720 797 900 75
Ultra1000 GRP 20
I
H and 40 808 950 90
S Ultra1200 GRP frame 20
ID1 with 620 725 860 136
SFRC cover 40
OD1

Cone extension piece (710 OD) - This specially designed GRP frame with SFRC cover
extension piece can be used for extension of cone up to 300 OD
mm to increase the manhole height.
H
Cone extension piece ID OD ID1 OD1 S I I1 I2 H
ID
590 OD 574 590 550 566 58 300 200 100 358
OD1
710 OD 641 710 625 640 100 292 - - 392

Rubber Sealing Ring Accessories


Specially designed rubber sealing rings are provided to Telescopic adapter- It can be used with
connect different manhole components like manhole base, Ultra 600 chamber for height adjustment
shaft pipe and cone. The sealing ring is tested at 0.5 kg/cm² on site.
that ensures 100% water tight joints and makes the manhole
free from any infiltration and ex-filtration.
In-situ adapter - Besides inlet(s) of
Cone Extension selected flow profile of the base, additional
Cone
Cone
Extension
extension
Piece
piece Piece
connections are possible through shaft or
cone at different heights or angles by using
Rubber
Rubber
Seal
seal
specially designed in-situ adapters. These
Cone adaptors are available in 75, 110, 160 and
200 mm sizes to access any line even in
Cone or post installation condition.
shaft socket

Ultra 1000 Lateral pipe Connector - This innovative,


Sealing Ring
specially designed connector to connect
Corrugated shaft individual house connection with the road
side sewer without disturbing the
functioning of running sewer.

RCC pipe adapters - Specially designed


adapters are also made available to
connect RCC pipes with the manholes.
Note : All dimensions unless specified are in mm.
17
Accessories
DWC Fittings Nu-Drain Fittings

Different Types of Fittings - To meet the


complete sewer system requirements we
offer various piping systems like uPVC, PE
and DWC pipes with corresponding fittings
to facilitate easy and fast installation.

Specifications
Diameter : DN 800/1000/1200 Chemical resistance : Sewer environment
Material : Polyethylene (PE) Load bearing capacity : Heavy traffic up to 40 MT
Colour : Black Covers : Light to heavy traffic
Standard : EN 13598 -2
* 1-6 mtrs with standard installation conditions
Installation depth : 1-6m*, with a maximum
ground water level of 5 m.

Product Testing
Performance of Ultra manhole components is ensured by carrying out vigorous tests as per EN 13598. Some of the important
tests are shown bellow in the visual form .

Load test Stiffness of the shaft Vacuum test

Ladder pullout Test Impact strength Anti-floatation test

18
Installation Procedure
Installation has the major influence over the performance of manholes. The easy and faster installation, reduced manpower
requirements due to light weight structure and a very easy connection to the sewage system are some of the important factors
that contribute towards reducing the installation costs of Supreme ultra manholes compared to the conventional manholes.
Installation of Supreme Ultra manhole is very simple and quick using specially designed rubber seal joints. Connections between
different components of manhole, viz., base, shaft and cone (three piece design) as well as pipe connection with the manhole
base is very simple using push fit type rubber seal joints. Backfilling and compaction is very important for achieving desired
strength. Use of sand or non cohesive material like stone dust or small grained gravel is recommended for backfilling. It is advised
to consult our team of engineers where water table is too high. Following simple steps are recommended for an easy, quick and
safe installation.

1 2 3 4

4A 4B 5 6

1) Excavation and bedding • Apply lubricant evenly on the rubber seal fitted on the
• Excavate a pit 60 cm wider and 50 cm deeper than the base and on the socket of the shaft.
size of the manhole base. • Bring the shaft to the correct position and see that the
• Prepare a 15 cm thick bed of recommended suitable ladder aligns well with the benching or required suitable
material and compact it up to 95% proctor density. position. Push and place the shaft on the base uniformly
2) Pipe connections to full insertion depth.
• Place the manhole base in position on a compacted bed, • Repeat the procedure in case of more than one shaft.
adjust and align to the correct level using spirit level. Shaft can be cut on site as per the requirement.
• Apply lubricant on sealing ring of inlets and outlet and 5) Connection of cone
make the connection with pipe by pushing the base to • Bring the cone in the right position and install the cone
the spigot of pipe. by pushing it evenly on the shaft fitted with rubber seal.
• In case of manhole base without monolithic inlet/outlet, Make sure that the rubber lubricant is properly applied
make the hole(s) using core cutter and make the pipe on the rubber seal before making the joint. Ensure proper
joint using rubber sealing ring. alignment of ladder while placing the cone.
3) Backfilling and compaction 6) Installation of frame and cover
• Backfill the surrounding with suitable material in 30 cm • Provide 150 mm thick PCC (M20) at the top and embed
layers with proper compaction. frame considering finish level.
• Backfilling in 30 cm layers with proper compaction • Place the cover of suitable load class and finish off with
should be repeated for all the manhole components up road top.
to the ground level for entire depth of installation. Note: For single piece manhole of pre-selected invert depth, the
4) Connection of shaft (s) installation procedure remains the same except step by step installation
of three different manhole components. Then the backfilling and
• Clean and place the rubber sealing ring on the exterior
compaction should be carried out from the bottom surface to the top
face of the manhole base i.e. between top two ribs. Check level ensuring the vertical alignment.
the sealing ring for proper placement & damages, if any.

19
...a real breakthrough in sewer technology

• All the dimensions unless otherwise are in mm • Any specification may change without prior notice. • All information contained in this literature is given in good faith and
believed to be accurate and reliable. Because of many factors which may be outside our knowledge or control and affect the use of the product, no warranty is given or
implied with respect to such information, nor do we offer any warranty of immunity against patent infringement. No responsibility can be accepted for any error, omissions
or incorrect assumptions.

The Supreme Industries Ltd. (Plastic Piping Division) Branch Offices


Ahmedabad
' Tel.
: 079-27681365,66
Bangalore : 080-22104696,97
Corporate Office: 1161/1162, Solitair Corporate Park, Bhubaneswar : 0674-7192001
Building No. 11,167, Guru Hargovindji Marg, Chakala, Chennai : 044-35013180, 90
Guwahati : 09864169173
Andheri Ghatkopar Link Road, Andheri (East) Mumbai - 400 093. India. Kochi : 0484-2385345,46
Tel: 91-22-4043 0000, 6869 0000 Hyderabad : 040-23262884
Indore : 0731-4956061
Regd. Office: 612 Raheja Chambers, Nariman Point, Mumbai 400 021. Jabalpur : 0761-4032910
India. Tel.: (022) 6257 0000, 6257 0025 Jaipur : 0141-4917985,235
Jalgaon Gadegaon : 0257-3501541 to 45
Kanpur : 0512-2982633
Export Division: Tel: (022) 4043 0125, 3084 0125 Kolkata : 033-40820000,102
Overseas Office: Sharjah, UAE. Tel# +971 6 557 4484; Fax# +971 6 557 4485 Noida (Delhi) : 0120-6660000
Patna : 09147008444
Raipur : 07208861909
Ranchi : 07605079821
CIN: L35920MH1942PLC003554 Vijayawada : 09000822522 I & T SIL Gadegaon, Dist-Jalgaon=PC/NUM/MKG/67=REV.07-09/2022

Download the App


Toll Free: 1800-102-4707 pvc-pipes@supreme.co.in www.supreme.co.in
Since 1942

Supreme Pipes