IMPEDANCE IMPEDANCE LTACE UAE troight hr permitted envelop creight lar Ky TRANSFORMEL ky TRANSFORME! PID TRANSFORMEL IMPEDANCE ENVELOPE i Trae t mz Dravig rariber UK ~ OH rove: <> FI [o Typed Te Networks: burt va SEPARABLE rscomecrar PLAN it bh eure = ELEVATION AL ae ORR ALES cA we Programme Su D> n Networks Delivery STANDARD 2 WINDING & 3 WINDING 132kV GRID TRANSFORMER CONNECTION ARRANGEMENT FOS 04-8000.4 ‘STANDARD ORAWING ‘aoa Pn Mer. ing yb ado ed ww eo 230V SUPPLY H71 Ha TAPCOM2 SLIDE SWITCH SET UP AB AB ss-3 mL | ss-19 on on ss4 | ss-20 sss ml] ss21 7 = ss 88-22 ss7 | ss-23 sss Mi] ss-24 S810 88-26 ss-11_ | $8.27 TAP POSITION pss iss \ TAPCOM2 $s-12 88-28 RESISTOR CHAIN _ TAPCHANGE CONTROL UNIT $813 $8.29 Ry (FOR DETAILS SEE BRUSH Ss-14 ss-30 DRAWING No. C585585) MoTOR $815 $831 LOWER RAISE "TRIP soi o2 “715101 lis fis so 2% met $S-17 ro) OG DG ° 8 Pe Z| S| zB} 2} 2} 3 MM. N73" csr 4 a. | s in| rer, | RTMUFam w P LOWER RAISE 8 ob OB} Lott |_4 RR (SR a]_N76" —————— i/ t, TR Ls 4 31 34) — L__F & Ss} s RVG { ee | [TPT 1 = 2 ja TP+ 3 TBs 5 TPOS 1 x72 mm ~o-19 L_TRITO . SCADA 6 TP. 10) xm mat iy ALTERNATIVE TRANSDUCER OUTPUTS AVAILABLE ARE 0-20mA & 4-20mA IRTMUrZm 2s os | TPH a RELAYS ARE REQUIRED FOR STANDARD PROTECTION ‘SCHEMES AND MOUNTED ON TAP CHANGE CONTROL, PANELS. THESE AND ADDITIONAL FLAG RELAYS MAY BE REQUIRED ON RETROFITS TO EXISTING SITES ai so _N300* Ld VOLTAGE RED'N CONNECTIONS TO RVM/5m RELAY FOR TX1 J2(72) Lat FSt | a1) = RVMISm a on) LT Lt +e RTMUF2m ae je A) ts, ‘tov oc xa33 (12) ALARM SUPPLY FAIL XS47 2) VOLTAGE CONTROL 1) FAUL' 549.65) TAP CHANGER 12) FAULTY X0_/~ ALARMIINDICATION AN) COMMON po DRIVE MECH | IP SIGNAL 45 46 I X115 2) TAP CHANGE i TT LDN PROGRESS a | TIC | | 82 an) |__X113 57>) TAP CHANGER ON iss : NW LOCAL CONTROL | SEENOTEON | > SCADA TERMINALS 1 — I CSR TR, | X11 ReMoTEMANUAL Hi) TAPRING SELECTED ES 19k, |__X109--> auToMaTic VOLTAGE T 1!) CONTROL SELECTED xo_| | | LRRI TR, X101-<> 39% OFF INDICATION a {11) (NOT USED IN EPNISPN) x103 — Es A, - 3) 3% ON INDICATION x0 | LRR2 TR, X105 >) 6% OFF INDICATION {U) (NOT USED IN EPN/SPN) xt07 = te {F13) 6% ON INDICATION LRRI a w54 (15) 3% VOLTAGE REDUCTION ON Te rh ws2 2. @ ¥ 72) 9% VOLTAGE REDUCTION OFF, Ti! T1) CONTROL COMMON : "(8% VOLTAGE REDUCTION +ve) | | LRR2 | a TY t z te I ~ | ~ ws6 2} L Gi) 6% VOLTAGE REDUCTION OFF f wes | ; Lig 5 oe VOLTAGE REDUCTION +ve0 | SEENOTEON = —cb _ SCADA TERMINALS] a wee 2 | a) a (72) RAISE TAP | I siR > | wes Lets (13) LOWER TAP mit WES Lower TAP 4 te I SAR 2 | wee G2) SELECT AUTOMATIC Ty t (1) VOLTAGE CONTROL rt 4 sevecr CONTROL AUTO #ve | Sw | 2 | Wes SELECT REMOTE/MANUAL Lt (1) TAPPING mt WSS 4 SELECT CONTROL MANUAL +ve TBS _ RVM/Sm* 32],_N306* RVM/Sm* 32]_N306* 31 30, VOLTAGE RED'N CONNECTIONS TO RVM/5m RELAY FOR TX2 INDICATIONS ‘SCADA FUNCTIONS ARE TO BE CONNECTED TO THE TERMINALS ‘SHOWN (BY NUMBER) IN ORDER FROM THE TOP DOWNWARDS. COLOUR CODED PAIRED CABLE WILL BE TERMINATED AS SHOWN STANDARD SCHEDULE (FROM OPS TELECOMS) CONTROLS ‘SCADA FUNCTIONS ARE TO BE CONNECTEDTO THE TERMINALS, ‘SHOWN (BY NUMBER) IN ORDER FROM THE TOP DOWNWARDS. COLOUR CODED PAIRED CABLE WILL BE TERMINATED AS SHOWN STANDARD SCHEDULE (FROM OPS TELECOMS) BUS-WIRING BETWEEN VOLTAGE q + CONTROL RELAYS a Fsff es = FL XX TRANSDUCER SHOULD ~\ [sor OO BE DC POWERED ON Son 0-2 INPUT NEW INSTALLATIONS c ot "Ab 0-10mA TRANSDUCER AND IS MOUNTED IN TI ——0—_—_$¢ EQUIPMENT PANEL L00-c7/ VEPHASE RELATIONSHIP REQUIRED FOR ¢ : ‘CORRECT VOLTAGE CONTROL OPERATION 5 a ASSUMING STANDARD ANTI-CLOCKWISE ROTATION i TTB1-2 4TRANS S| EE a 6 8 4 8 CT IN CIRCUIT BREAKER CT IN TRANSFORMER SHoRTING Link > —3— LOAD (NORMALLY OPEN) VMI 1 [8 5 x23 5 CONNECTION FOR | I} | esta f 1 TRANSF ONLY sc 030" pen rt 3¢_D30 6 a | i < 5 —§ ‘b’ phase LI sg} 3 62 a) 4 ri 5 5 RTMUP2m cE 518g 2ND OF 2 X TRANSF gg FROM VT uae » £31 - F30 ° oe 1! a 2 seconoary "oft —o 8 | rweIwreRconneona “ a} 6} BUS WIRES MAY NOT BE cy E51 ois F50 p REQUIRED FOR ~ INSTALLATIONS IN THE LPN AREA 6 4 4 ‘ INTERMEDIATE CONNECTION FOR ee sosses (CL | oss Ht 478. Et, 1s Hs Ha St +e ee 2 Hs yp a FROM see tae S| 3 110V He HB H7 So) So ¢ « > SUPPLY cH o o . Ho, i sta 4 o NOTE: BUSWIRES ARRANGED TO FACILITATE TESTING BY USE OF 'CLIP' ON CT COMPONENT LISTING ITEM DESCRIPTION TYPE LOCATION thee | DESCRIPTION RATING Dss DIRECTIONAL SEQUENCE SWITCH, DM FS1 ALARM RELAY SUPPLY +ve 6A Lss LOCAL SELECTOR SWITCH DM LK1 ALARM RELAY SUPPLY -ve : AL ALARM RTMU/2m vec Fs2 TRANSDUCER SUPPLY ” cH CUBICLE HEATER vec FS3 TRANSDUCER SUPPLY ” ci CUBICLE LAMP vec csr | CONTROL SELECT RELAY KDNU200 110VAC vec CSR RELAY SOCKET PSF3 vec FS4 CUBICLE ILLUMINATION SUPPLY 6A Ds DOOR SWITCH vcC FS6 CUBICLE ILLUMINATION SUPPLY 6A HS. HEATER SWITCH vec Il INDICATOR LAMP LED vec FSs7 CUBICLE HEATER SUPPLY 10A ip IN PROGRESS INPUT RTMU/2m vec FSB CUBICLE HEATER SUPPLY 104, L LOWER RTMUI2m & RVMISm vec Lio Lock ouT RTMUI2m vec uK2 RED PHASE VOLTS - LB LOWER TAP BLOCK RTMU/2m vec LK3 YELLOW PHASE VOLTS - LRR1 | VOLTAGE REDUCTION RELAY 3% KONU200 vec Luka BLUE PHASE VOLTS : LRR2 | VOLTAGE REDUCTION RELAY 6% KDNU200 vec PS. POWER SUPPLY RTMU/2m & RVM/Sm vec R RAISE, RTMU/2m & RVM/Sm vec RB RAISE TAP BLOCK RTMUI2m vec RTMUI2m| CONTROL AND MONITOR RELAY vec RVM/Sm | VOLTAGE CONTROL RELAY vec SAR SELECT AUTO RELAY DU200 vec SAR RELAY SOCKET PSF3 vec sct | SUMMED CURRENT TRANSDUCER ISTAT 300 3CDFES vec SLR SUPERVISORY LOWER RELAY DU200 vec SMR SELECT MANUAL RELAY DU200 vec SRR | SUPERVISORY RAISE RELAY U200 vec 1B MULTICORE TERMINAL BLOCK vec Tes SCADA TERMINAL BLOCK vec TPT TAP POSITION TRANSDUCER FTPTII vee VC FAIL | VOLTAGE CONTROL FAIL FLAG RELAY | MVAASELF RESETCONTACTS | Vcc. TEIGTaT oH BOERS. SCROR Ron Tams aT HAND RESET FLAG E | 24052011 | win ena scnocle = ido og lays, Upaied col ay comnecions. | TC FAIL | TAP CHANGE FAIL FLAG RELAY MVAA SELF RESET CONTACTS vec D 12-06-2010 | SCADA numbering added. HAND RESET FLAG Adgition of alarm supply failure relay. fo 9 6% RES COMMON SPLIT TO ASFAIL | ALARM SUPPLY FAIL FLAG RELAY Maxie vec © | zrop2tne | séeagare | NCOMMOASENT Tor conse raving Pelayo SCADA rele SRR SLR, SMR & SLR oie 1181-2 | TEST TERMINAL BLOCKS vec 3. | 2852008 | Teminat nos ofrese: col of LRT & LRRO coveted vec VOLTAGE CONTROL CUBICLE Layout of bus winng connectons redrawn om DRIVE MECHANISM ENCLOSURE A | 2006-11-20 ORIGINAL Deel lesen] ate DESCRIPTION = WIRE NUMBERS RTMU/2m SCADA TERMINALS UK ~ FOR * INSERT: 11 FOR TRANSFORMER No. 1 THIS IS THE ONLY UNIT TYPE TO BE USED WITH THIS: ‘SCADA WIRING MUST BE CONNECTED TO THE TERMINALS Power T2 FOR TRANSFORMER No. 2 CONTROL SCHEME IN ORDER TO FACILITATE CONTROL SHOWN. Networks T3 FOR TRANSFORMER No. 3 SELECTION FROM VCC OR CONTROL CENTRE EXTERNAL WIRING IS NOT FERRULED BUT IS TERMINATED IN Ta FOR TRANSFORMER No. 4 STANDARD COLOUR ORDER TO ALIGN WITH TELECOM Standard AVC Sch WIRING SCHEDULE FOR TEC. tandarc cheme KDNU AND DU RELAYS - MORS SMITT FITTED With PROTECTION DIODE SCADA TERMINAL NUMBER (Supertapp) EQUIVALENT AREVA OR REYROLLE (ATL Old Type) RELAYS MAY BE SUBSTITUTED ALARMIINDICATION AND CONTROL COMMONS ARE SHOWN ‘AS SEPARATE TERMINALS AS ON SOME LEGACY INSTALLATIONS THESE MUST BE SEPARTELY TERMINATED IN maa THE OUTSTATION sere N.T.S. @40 [Approved ae SPS LW DRAWING NO. Version se Automatic Voltage Control Copyright owned by UK Power Networks. This drawing may not be used or copied without written consent. Original CAD files shall not be issued outside the company and its contractors.

You might also like