You are on page 1of 42

SUMMARY

Sl No. Description of Subhead

1 Internal Electrical
a) Electrical Wiring Part
b) Distribution Boards
c) Rising Mains
d) Light Fixtures and Fans
e) Cable Trays
f) LT Cables & Terminations for buildings
g) UPS
h) Earthing & Lightning Protection
i) Building Panels

2 External Electrical
a) External Lighting
b) Transformers
c) DG System
d) Bus Ducts
e) HT Panels
f) LT Panels
g) External Cables & Terminations
QUANTITY DETAILS FOR ELECTRICAL WIRING ITEMS & DISTRIBUTION BOARDS AND RELATED ITEMS

Sl No. Area

Gr.C Primary point Gr.B Primary point 8.5 Mtr Long Primary point Gr.A Secondary point Gr.C Secondary point Gr.B Secondary point Group Controlled Group Controlled Group Controlled
Points from DB Points from DB Points from DB
(Gr. C @ 5 Mtr) (Gr. B @ 4 Mtr) (Gr. A @ 3 Mtr)
with Steel with Steel with Steel
Conduits Conduits Conduits
(Item No. 7a) (Item No. 7b) (Item No. 7c)

Steel PVC Steel PVC Steel PVC Steel PVC Steel PVC Steel PVC
(Item No. 6a) (Item No. 1a) (Item No. (Item No. 1b) (Item No. (Item No. 1c) (Item No. 3c) (Item No. (Item No. 3b)
6b) 6c) 3a)
BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & BOQ ELECTRICAL WIRING & EARTHING
EARTHING EARTHING EARTHING EARTHING EARTHING EARTHING

A. Second Basement :

Stairs for both towers -- 12 Nos


Store Rooms for Both Towers 8 8
Staircase Lobbies north and south 24
Sides for both towers
Staircase Lobbies west and east 8
Sides for both towers
2.5 Mtr Wide Passages for both 112
towers
4.0 Mtr Wide Passages North & 28
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 20
West for both towers
3.5 Mtr Wide lobby for both 64
towers
Parking Lots 442
6 Mtr Driveway
Total 2nd Basement 8.00 8.00 - - - - 8.00 442.00 248.00

B. First Basement :
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers 8 8
Staircase Lobbies north and south 24
Sides for both towers
Staircase Lobbies west and east 8
Sides for both towers
2.5 Mtr Wide Passages for both 112
towers
4.0 Mtr Wide Passages North & 28
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 20
West for both towers
3.5 Mtr Wide lobby for both 64
towers
Parking Lots 442
6 Mtr Driveway
Total 1st Basement 8.00 8.00 - - - - 8.00 442.00 248.00

C. Ground Floor:
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers 4 4
Gents Toilet for both towers 12 40
Ladies Toilet for both towers 2 2 18
2.5 Mtr Wide Passages for both 112
towers
4.0 Mtr Wide Passages North & 28
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 20
West for both towers
3.5 Mtr Wide lobby for both 64
towers
Reception 8 32
Parking Lot 350
Driveways
Total Ground Floor 26.00 6.00 - - - 90.00 - 350.00 224.00

D. 1st Floor :
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers 4 4
Gents Toilet for both towers 16 80
Ladies Toilet for both towers 14 68
2.5 Mtr Wide Passages for both 112
towers
4.0 Mtr Wide Passages North & 28
South with service lobbies for
both towers
QUANTITY DETAILS FOR ELECTRICAL WIRING ITEMS & DISTRIBUTION BOARDS AND RELATED ITEMS

Sl No. Area

Gr.C Primary point Gr.B Primary point 8.5 Mtr Long Primary point Gr.A Secondary point Gr.C Secondary point Gr.B Secondary point Group Controlled Group Controlled Group Controlled
Points from DB Points from DB Points from DB
(Gr. C @ 5 Mtr) (Gr. B @ 4 Mtr) (Gr. A @ 3 Mtr)
with Steel with Steel with Steel
Conduits Conduits Conduits
(Item No. 7a) (Item No. 7b) (Item No. 7c)

Steel PVC Steel PVC Steel PVC Steel PVC Steel PVC Steel PVC
(Item No. 6a) (Item No. 1a) (Item No. (Item No. 1b) (Item No. (Item No. 1c) (Item No. 3c) (Item No. (Item No. 3b)
6b) 6c) 3a)

4.0 Mtr Wide Passages East & 20


West for both towers
3.5 Mtr Wide lobby for both 64
towers
Office total 8 nos / floor including 208 208
both towers (for ceiling fans )

Reception inside Office (total 8 8 16


nos)
Discussion lounge inside office 8 8 16
(total 8 nos)
Seater Conference Rooms (total 8 16 40
nos)
Cabins 2 nos ( total 16 nos) 32
Large cabins 4 nos each office 128 160
(total for 8 nos of offices)
Attached toilets to the large cabins 32 64

Server / File (total 8 nos) 8


Cubicle (total 8 nos) 8
Office area other than cabins and 96 328
toilets (total for 8 nos of offices)
Total 1st Floor 242.00 528.00 - 108.00 - - - - - - - 692.00 - - 224.00
E. Total from 2nd to 16th Floor 3,630.00 7,920.00 - 1,620.00 - - - - - - - 10,380.00 - - 3,360.00
(Typical to 1st Floor)

TOTAL TOWER AREA 3,914.00 8,448.00 22.00 1,728.00 - - - - - - - 11,162.00 16.00 1,234.00 4,304.00
QUANTITY DETAILS FOR ELECTRICAL
QUANTITY DETAILS
WIRING FOR
ITEMS
ELECTRICAL
& DISTRIBUTION
WIRINGBOARDS
ITEMS &AND
DISTRIBUTION
RELATED ITEMS
BOARDS AND RELATED ITEMS

Sl No. Area Item Wise Quantities for Electrical Wiring

Group Controlled Twin Twin MCB Isolator with Switch Socket Switch Socket Switch Socket Switch Socket Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main
Points from DB Controlled Controlled Enclosure , with 16- Combination Sets Combination Sets Combination Sets Combination Sets 3R X 2.5 Sqmm 3R X 4.0 Sqmm 3R X 6.0 Sqmm
(Long @ 8.5 Mtr) Light Points Light Points 32 Amp DP Isolator of (5-6 Amp Socket of (6/16 Amp of (2 Nos 6 Amp of (2 Nos 6/16 Amp
with Steel with PVC with Steel + 5-6 Amp Switch) Socket + 16 Amp Sockets + 2 Nos 6 Sockets + 2 Nos 16
Conduits Conduits Conduits Item Nos. 7.a & 10a (Item No. 10a) Switch) Amp Switches) Amp Switches)
(Item No. 7d) (Item No. 4) (Item No. 8) (Item No. 10b) (Item No. 10c) (Item No. 10d)

PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit
(Item no. 5a) (Item No. 9a) (Item no. 5b) (Item No. 9b) (Item no. 5c) (Item No. 9c)

BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & BOQ For Distribution BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING
EARTHING Boards
A. Second Basement :

Stairs for both towers -- 12 Nos 24 144


Store Rooms for Both Towers 8 696 696
Staircase Lobbies north and south 4 120
Sides for both towers
Staircase Lobbies west and east 8 4 140
Sides for both towers
2.5 Mtr Wide Passages for both 12 720
towers
4.0 Mtr Wide Passages North & 4 220
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 4 220
West for both towers
3.5 Mtr Wide lobby for both 8 560
towers
Parking Lots 43 2365
6 Mtr Driveway 147 18 810
Total 2nd Basement 179.00 - - 97.00 - 5,995.00 - 696.00 - -

B. First Basement :
Stairs for both towers -- 12 Nos 24 144
Store Rooms for Both Towers 696 696
Staircase Lobbies north and south 4 120
Sides for both towers
Staircase Lobbies west and east 8 4 140
Sides for both towers
2.5 Mtr Wide Passages for both 12 720
towers
4.0 Mtr Wide Passages North & 4 220
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 4 220
West for both towers
3.5 Mtr Wide lobby for both 8 560
towers
Parking Lots 43 2365
6 Mtr Driveway 147 18 810
Total 1st Basement 179.00 - - 97.00 - 5,995.00 - 696.00 - -

C. Ground Floor:
Stairs for both towers -- 12 Nos 24 144
Store Rooms for Both Towers 696 696
Gents Toilet for both towers 210
Ladies Toilet for both towers 270
2.5 Mtr Wide Passages for both 12 780
towers
4.0 Mtr Wide Passages North & 4 240
South with service lobbies for
both towers
4.0 Mtr Wide Passages East & 4 240
West for both towers
3.5 Mtr Wide lobby for both 8 520
towers
Reception 50
Parking Lot 35 1225
Driveways 135 14 560
Total Ground Floor 159.00 - - 77.00 - 4,935.00 - 696.00 - -

D. 1st Floor :
Stairs for both towers -- 12 Nos 24
Store Rooms for Both Towers
Gents Toilet for both towers
Ladies Toilet for both towers
2.5 Mtr Wide Passages for both 12 144
towers
4.0 Mtr Wide Passages North & 4 260
South with service lobbies for
both towers
QUANTITY DETAILS FOR ELECTRICAL
QUANTITY DETAILS
WIRING FOR
ITEMS
ELECTRICAL
& DISTRIBUTION
WIRINGBOARDS
ITEMS &AND
DISTRIBUTION
RELATED ITEMS
BOARDS AND RELATED ITEMS

Sl No. Area Item Wise Quantities for Electrical Wiring

Group Controlled Twin Twin MCB Isolator with Switch Socket Switch Socket Switch Socket Switch Socket Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main
Points from DB Controlled Controlled Enclosure , with 16- Combination Sets Combination Sets Combination Sets Combination Sets 3R X 2.5 Sqmm 3R X 4.0 Sqmm 3R X 6.0 Sqmm
(Long @ 8.5 Mtr) Light Points Light Points 32 Amp DP Isolator of (5-6 Amp Socket of (6/16 Amp of (2 Nos 6 Amp of (2 Nos 6/16 Amp
with Steel with PVC with Steel + 5-6 Amp Switch) Socket + 16 Amp Sockets + 2 Nos 6 Sockets + 2 Nos 16
Conduits Conduits Conduits Item Nos. 7.a & 10a (Item No. 10a) Switch) Amp Switches) Amp Switches)
(Item No. 7d) (Item No. 4) (Item No. 8) (Item No. 10b) (Item No. 10c) (Item No. 10d)

PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit
(Item no. 5a) (Item No. 9a) (Item no. 5b) (Item No. 9b) (Item no. 5c) (Item No. 9c)

4.0 Mtr Wide Passages East & 4 220


West for both towers
3.5 Mtr Wide lobby for both 8 360
towers
Office total 8 nos / floor including
both towers (for ceiling fans )

Reception inside Office (total 8 16 144 248


nos)
Discussion lounge inside office 16 120 208
(total 8 nos)
Seater Conference Rooms (total 8 64 16 104 592 128
nos)
Cabins 2 nos ( total 16 nos) 16 16 224 240
Large cabins 4 nos each office 32 32 32 672 1632
(total for 8 nos of offices)
Attached toilets to the large cabins 320

Server / File (total 8 nos) 16 8 40 80


Cubicle (total 8 nos) 8 64 64
Office area other than cabins and 312 312 90 3312 440
toilets (total for 8 nos of offices)
Total 1st Floor 24.00 - - 28.00 432.00 32.00 424.00 8.00 1,778.00 984.00 6,296.00 - 648.00 -
E. Total from 2nd to 16th Floor 360.00 - - 420.00 6,480.00 480.00 6,360.00 120.00 26,670.00 14,760.00 94,440.00 - 9,720.00 -
(Typical to 1st Floor)

TOTAL TOWER AREA 901.00 - - 719.00 6,912.00 512.00 6,784.00 128.00 28,448.00 32,669.00 100,736.00 2,088.00 10,368.00 -
QUANTITY DETAILS FOR ELECTRICAL
QUANTITY
WIRING
DETAILS
ITEMSFOR
& DISTRIBUTION
ELECTRICAL WIRING
BOARDSITEMS
AND &
RELATED
DISTRIBUTION
ITEMS BOARDS AND RELATED ITEMS

g Sl No. Area

Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Distribution Boards Distribution Distribution Distribution Distribution
6R X 2.5 Sqmm 2R X 10 + 1R X 6 Sqmm 2R X 16 + 1R X 6 Sqmm 4R X 10 + 2R X 6 Sqmm 4R X 16 + 2R X 6 Sqmm (SPN 12 Way) Boards (SPN 16 Boards (HTPN 8 Boards Boards
Way) Way) (HTPN 12 (VTPN 12
Way) Way)

PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit Item No. 1e Item No. 1g Item No. 2e Item No. 2f Item No. 3d
(Item no. 5d) (Item No. 9d) (Item No. 9e) (Item No. 9f) (Item No. 9i) (Item No. 9j)

BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ ELECTRICAL WIRING & EARTHING BOQ FOR DISTRIBUTION BOARDS

A. Second Basement :

Stairs for both towers -- 12 Nos


Store Rooms for Both Towers
Staircase Lobbies north and south
Sides for both towers
Staircase Lobbies west and east
Sides for both towers
2.5 Mtr Wide Passages for both
towers
4.0 Mtr Wide Passages North &
South with service lobbies for
both towers
4.0 Mtr Wide Passages East &
West for both towers
3.5 Mtr Wide lobby for both
towers
Parking Lots
6 Mtr Driveway
Total 2nd Basement - - 240.00 255.00 160.00 320.00 3.00 3.00 2.00 2.00 2.00

B. First Basement :
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers
Staircase Lobbies north and south
Sides for both towers
Staircase Lobbies west and east
Sides for both towers
2.5 Mtr Wide Passages for both
towers
4.0 Mtr Wide Passages North &
South with service lobbies for
both towers
4.0 Mtr Wide Passages East &
West for both towers
3.5 Mtr Wide lobby for both
towers
Parking Lots
6 Mtr Driveway
Total 1st Basement - - 240.00 - 255.00 - 160.00 - 320.00 3.00 3.00 2.00 2.00 2.00

C. Ground Floor:
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers
Gents Toilet for both towers
Ladies Toilet for both towers
2.5 Mtr Wide Passages for both
towers
4.0 Mtr Wide Passages North &
South with service lobbies for
both towers
4.0 Mtr Wide Passages East &
West for both towers
3.5 Mtr Wide lobby for both
towers
Reception
Parking Lot
Driveways
Total Ground Floor - - 240.00 - 255.00 - 160.00 - 320.00 3.00 3.00 2.00 2.00 2.00

D. 1st Floor :
Stairs for both towers -- 12 Nos
Store Rooms for Both Towers
Gents Toilet for both towers
Ladies Toilet for both towers
2.5 Mtr Wide Passages for both
towers
4.0 Mtr Wide Passages North &
South with service lobbies for
both towers
QUANTITY DETAILS FOR ELECTRICAL
QUANTITY
WIRING
DETAILS
ITEMSFOR
& DISTRIBUTION
ELECTRICAL WIRING
BOARDSITEMS
AND &
RELATED
DISTRIBUTION
ITEMS BOARDS AND RELATED ITEMS

g Sl No. Area

Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Submain / Circuit Main Distribution Boards Distribution Distribution Distribution Distribution
6R X 2.5 Sqmm 2R X 10 + 1R X 6 Sqmm 2R X 16 + 1R X 6 Sqmm 4R X 10 + 2R X 6 Sqmm 4R X 16 + 2R X 6 Sqmm (SPN 12 Way) Boards (SPN 16 Boards (HTPN 8 Boards Boards
Way) Way) (HTPN 12 (VTPN 12
Way) Way)

PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit PVC Conduit Steel Conduit Item No. 1e Item No. 1g Item No. 2e Item No. 2f Item No. 3d
(Item no. 5d) (Item No. 9d) (Item No. 9e) (Item No. 9f) (Item No. 9i) (Item No. 9j)

4.0 Mtr Wide Passages East &


West for both towers
3.5 Mtr Wide lobby for both
towers
Office total 8 nos / floor including
both towers (for ceiling fans )

Reception inside Office (total 8


nos)
Discussion lounge inside office
(total 8 nos)
Seater Conference Rooms (total 8
nos)
Cabins 2 nos ( total 16 nos)
Large cabins 4 nos each office
(total for 8 nos of offices)
Attached toilets to the large cabins

Server / File (total 8 nos) 452 452 904 1356


Cubicle (total 8 nos)
Office area other than cabins and
toilets (total for 8 nos of offices)
Total 1st Floor - - - 452.00 - 452.00 - 904.00 - 1,356.00 8.00 8.00 8.00 8.00 8.00
E. Total from 2nd to 16th Floor - - - 6,780.00 - 6,780.00 - 13,560.00 - 20,340.00 120.00 120.00 120.00 120.00 120.00
(Typical to 1st Floor)

TOTAL TOWER AREA - - - 7,952.00 - 7,997.00 - 14,944.00 - 22,656.00 137.00 137.00 134.00 134.00 134.00
INTERNAL ELECTRICAL _ ELECTRICAL WIRING & EARTHING

Sl No. Description of Items UOM Total

Electrical Wiring

1 SITC of Point Wiring with PVC Conduit & 3 X 1.5 Sqmm FRLS PVC Cu wires, Metal
Box, Modular plate , Switches etc as required complete as per specification.

a) Group C Each 8,448.00


b) Group B Each 1,728.00
c) Long Point (8.5 Mtr Length) Each -
-
2 SITC of Group Point Wiring , controlled by MCB from DB , including cost of 3X1.5 Each -
Sqmm FRLS PVC Cu Wires, PVC conduit 20 mm , but excluding cost of MCB & DB
Group C

-
3 SITC of Secondary Point Wiring , including cost of 3X1.5 Sqmm FRLS PVC Cu -
Wires, PVC conduit 20 mm ,
a) Group C Each -
b) Group B Each 11,162.00
c) Group A Each -
-
4 SITC of Twin Control Point with PVC conduit 20 mm , 3 X 1.5 Sqmm FRLS PVC Cu Each -
Wires , Metal Box, Modular plate , 2 way modular Switch etc as required complete
as per specification.
-
5 Sub Main and Circuit Main with PVC conduit of suitable size and accessories . -
a) 3X 2.5 Sqmm RMT 28,448.00
b) 3X 4.0 Sqmm RMT 100,736.00
c) 3X6.0 Sqmm RMT 10,368.00
d) 6X 2.5 Sqmm RMT -
e) 4X 4.0 Sqmm + 2 X 4.0 Sqmm RMT -
f) 4X 6.0 Sqmm + 2 X 6.0 Sqmm RMT -
g) 4X 16.0 Sqmm + 2 X 6.0 Sqmm RMT -
-
6 SITC of Point Wiring with Steel conduit & 3 X 1.5 Sqmm FRLS PVC Cu wires, Metal -
Box, Modular plate , Switches etc as required complete as per specification.

a) Group C Each 3,914.00


b) Group B Each 22.00
c) Long Point (8.5 Mtr Length) Each -
-
7 SITC of Group Point Wiring , controlled by MCB from DB , including cost of 3X1.5 Each -
Sqmm FRLS PVC Cu Wires, Steel conduit 20 mm , but excluding cost of MCB & DB

a) Group C Each 16.00


b) Group B Each 1,234.00
c) Group A Each 4,304.00
d) Long Point (8.5 Mtr Length) Each 901.00
-
8 SITC of Twin Control Point with Steel conduit 20 mm , 3 X 1.5 Sqmm FRLS PVC Cu Each -
Wires , Metal Box, Modular plate , 2 way modular Switch etc as required complete
as per specification.
-
9 Sub Main and Circuit Main with Steel conduit of suitable size and accessories . -
a) 3X 2.5 Sqmm RMT 32,669.00
b) 3X 4.0 Sqmm RMT 2,088.00
c) 3X6.0 Sqmm RMT -
d) 6X 2.5 Sqmm RMT -
e) 2X 10 + 1X6 Sqmm RMT 7,952.00
f) 2X 16 + 1X6 Sqmm RMT 7,997.00
g) 4X 4.0 Sqmm + 2 X 4.0 Sqmm RMT -
h) 4X 6.0 Sqmm + 2 X 6.0 Sqmm RMT -
i) 4X 10.0 Sqmm + 2 X 6.0 Sqmm RMT 14,944.00
j) 4X 16.0 Sqmm + 2 X 6.0 Sqmm RMT 22,656.00

10 Supplying and fixing the following Modular Switch Socket combinations with
suitable size of Metal boxes and modular front plates etc.
a) Switch Socket Combination Sets of (5-6 Amp Socket + 5-6 Amp Switch) Sets 6,912.00
b) Switch Socket Combination Sets of (6/16 Amp Socket + 16 Amp Switch) Sets 512.00
c) Switch Socket Combination Sets of (2 Nos 6 Amp Sockets + 2 Nos 6 Amp Switches) Sets 6,784.00

d) Switch Socket Combination Sets of (2 Nos 6/16 Amp Sockets + 2 Nos 16 Amp Sets 128.00
Switches)

11 Supply and laying of following sizes PVC Conduits along with accessories.

a) 20 mm dia Mtr 500


b) 25 mm dia Mtr 500
c) 32 mm dia Mtr 250

12 Supply and laying of following sizes Steel Conduits along with accessories.
a) 20 mm dia 500
b) 25 mm dia 750
c) 32 mm dia 400

TOTAL ELECTRICAL WIRING

Earthing & Lightning Protection

1 Supply of Advance Maintenance Free earthing environment friendly Chemical Sets 26


Earthing system consisting of 1no. of 3 mtr length, 19 mm dia earth electrode made
of steel circularrods, molecularly bonded copper on outer surface (minimum copper
bonding thickness 250microns ) with terminals to connect conductor with 2 bag
(25Kgs) of environment freindly back fill compound with DMC Pit Cover.
2 Advance chemical gel earthing system of Dual Pipe Technology (G.I.) Chemrode of Sets 18
3 mtrs long 80mm dia of outer pipe with the 50mm dia of inner pipe of 80-100
microns galvanized filled with highly conducting metallic compounds with the
permanent sealings at both the ends with the lead terminal of 50x10mm size at the
top. The length of the electrode shall be 3000mm excluding the lead terminal and
the length of the lead terminal at the top shall be 100mm. RMS short-circuit current
withstanding capacity of 30 KA and a peak short-circuit withstanding capacity of 60
KA. To ensure the moisture content and electrical conductivity, 50 Kgs of Reslow -
resistance lowering grounding minerals shall be used as a backfill compound. The
compound shall be of low resistance & high conductivity in nature with carbon as a
major content which dramatically lowers ground resistance system in difficult soil
situations. Test certificate from Standards), ccredited laboratory confirming the
contents. As per IEEE 80-2000 (clause 14.5d) standard, Test certificate from
accredited laboratory confirming the ohmic value of less than 0.12 ohm-mtr. The
moisture retaining capacity (pH Value) of the chemical back fill compound shall be
between 7 to 7.2. The chemical backfill compound shall be tested & certiifed by any
accredited laboratory and also the testing laboratory shall be an ISO 9001 & ISO
14001 certified. The earthing system manufacturer shall be an ISO 9001 & ISO 14001
certified to ensure the quality.All complete as per engineer-in-charge.

3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including Sets 132
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt
as required.

4 Supply and laying GI Earth strips of following sizes in ground including excavation
and backfilling of the earth as required.
50 X 8 GI Strip Rmtr 1043
75 X 8 GI Strip Rmtr 760
50 X 6 GI Strip Rmtr 4752

5 Supply and laying GI Earth strips / wires of following sizes along with cablle
trays / on walls or ceilings including proper clipping with necessary hardwares as
required.
50 X 6 GI Strip Rmtr 310
25 X 6 GI Strip Rmtr 3495
25 X 3 GI Strip Rmtr 250
8 swg GI Wire Rmtr 10636

6 Supply and laying Cu Earth strips of following sizes in ground including excavation
and backfilling of the earth as required.
25 X 5 Cu Strip Rmtr 500
50 X 5 Cu Strip Rmtr 320

7 Supply and laying GI Earth strips / wires of following sizes along with cablle
trays / on walls or ceilings including proper clipping with necessary hardwares as
required.
25 X 5 Cu Strip Rmtr 350
50 X 5 Cu Strip Rmtr 320

8 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, Sets 16
G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate
including holes etc. complete as required.

9 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Sets 1760
lightning conductor complete as required.(For horizontal run)

10 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for Sets 1152
lightning conductor complete as required.(For verical run)

11 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm Sets 16
long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as
required.

12 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in Mtr 320
ground as required.

TOTAL EARTHING & LIGHTNING PROTECTION


Sl No. Description of Items UOM

Total
1 SITC of Point Wiring with PVC Conduit & 3 X
1.5 Sqmm FRLS PVC Cu wires, Metal Box,
Modular plate , Switches etc as required
complete as per specification.
Group C Nos 48.00
Group B Nos 63.00
-
2 SITC of Secondary Point Wiring , including Nos 220.00
cost of 3X1.5 Sqmm FRLS PVC Cu Wires, PVC
conduit 20 mm ,---Group B
-
3 Circuit Main Wiring with PVC Conduit -
a) 3X 2.5 Sqmm Mtr 2,060.00
b) 3X 4.0 Sqmm Mtr 1,125.00
c) 3X6.0 Sqmm Mtr 90.00
-
4 Supplying and fixing the following Modular -
Switch Socket combinations with suitable size
of Metal boxes and modular front plates etc.

a) Switch Socket Combination Sets of (5-6 Amp Nos 17.00


Socket + 5-6 Amp Switch)
b) Switch Socket Combination Sets of (6/16 Nos 17.00
Amp Socket + 16 Amp Switch)
c) Switch Socket Combination Sets of (2 Nos 6 Nos 42.00
Amp Sockets + 2 Nos 6 Amp Switches)
-
5 Distribution Board of following types -
SPN 12 Way Sets 4.00
SPN 8 Way Sets 1.00
HTPN 8 Way Sets 2.00
HTPN 12 Way Sets 2.00
-
5 DP MCB --6-32 Amps Sets 5.00
SP MCB --6-32 Amps Sets 166.00
4P MCB 40-63Amps Sets 4.00
-
6 SITC of Light Fixtures and Fans -
LED 1200 mm Wall Light Fixture Sets 22.00
LED Recessed Mounted Down Light Fixture Sets 334.00

LED 4 Feet Tube Light with Driver Sets 50.00


Mirror Light Sets 22.00
1200 mm BLDC ceiling fans Sets 48.00
BOQ AND RATE ANALYSIS FOR DISTRIBUTION BOARDS

Sl No. Item Description UOM Qty

1 Double Door Distribution Boards, SPN , IP 42, IK-09


a) 4 Way (2+2) Each
b) 6 Way (2+4) Each
c) 8 Way (2+6) Each
d) 10 Way (2+8) Each
e) 12 Way (2+10) Each 137.00
f) 14 Way (2+12) Each
g) 16 Way (2+14) Each 137.00
h) 18 Way (2+16) Each

2 Double Door Distribution Boards, HTPN , IP 42, IK-09


a) 4 Way (8+12) Each
b) 4 Way (4+12) Each
c) 6 Way (8+18) Each
d) 6 Way (4+18) Each
e) 8 Way (8+24) Each 134.00
f) 12 Way (8+36) Each 134.00
g) 16 Way (8+48) Each
h) 20 Way (8+60) Each
Each
3 Double Door Distribution Boards, VTPN , IP 42, IK-09,
with MCB Incomer
a) 4 Way (8+12) Each
b) 6 Way (8+18) Each
c) 8 Way (8+24) Each
d) 12 Way (8+36) Each 134.00
e) 16 Way (8+48) Each

4 Double Door Distribution Boards, VTPN , IP 42, IK-09,


with MCCB Incomer
a) 4 Way (125+12) Each
b) 6 Way (125+18) Each
c) 8 Way (125+24) Each
d) 12 Way (125+36) Each
e) 16 Way (125+48) Each
f) 4 Way (160+12) Each
g) 6 Way (160+18) Each
h) 8 Way (160+24) Each
i) 12 Way (160+36) Each
j) 4 Way (250+12) Each
k) 6 Way (250+18) Each
l) 8 Way (250+24) Each
m) 12 Way (250+36) Each

5 Cable End Box


a) SPN Double Door, 4 way Each
b) SPN Double Door, 6 way Each
c) SPN Double Door, 8 way Each
d) SPN Double Door, 12 way Each
e) For ETPN 4 way DB Each
f) For SPN 16 way Each
g) ETPN 6 way DB Each
h) For SPN 18 way DB Each
i) For SPN 20 DB Each
j) For ETPN 8 way DB Each
k) For ETPN 12 way DB Each
l) For ETPN 16 way DB Each
m) For ETPN 18 way DB Each
n) For ETPN 20 way DB Each
o) For all ETPN 4W/VTPN/Flexy MCB Each
p) For all VTPN MCCB DBs Each

6 MCB , Group C , 10 KA , 240/415 Volts


a) Single pole 240/410 V , 6-32 Amps Each 11,328.00
b) Single pole + Neutral / DP, 240 V , 6-32 Amps Each
c) Single pole + Neutral / DP 240 V , 40-63 Amps Each 274.00
d) Triple pole 415 V , 6-32 Amps Each
e) Triple pole 415 V , 40-63 Amps Each
f) Four pole 415 V , 6-32 Amps Each
g) Four pole 415 V , 40-63 Amps Each 268.00
h) Single pole 230 V / 400 V , 80 Amps Each
i) Single pole 230 V / 400 V , 100 Amps Each
j) Single pole 230 V / 400 V , 125 Amps Each
k) Double pole 230 V / 400 V , 80 Amps Each
l) Double pole 230 V / 400 V , 100 Amps Each
m) Double pole 230 V / 400 V , 125 Amps Each
n) Triple pole 400 V , 80 Amps Each
o) Triple pole 400 V , 100 Amps Each
p) Triple pole 400 V , 125 Amps Each
q) Four pole 400 V , 80 Amps Each 134.00
r) Four pole 400 V , 100 Amps Each
s) Four pole 400 V , 125 Amps Each

7 Isolators Double Pole and Four Pole


a) Double pole 240 V , 32 Amps Each 719.00
b) Double pole 240 V , 40 Amps Each
c) Double pole 240 V , 63 Amps Each
d) Double pole 240 V , 80 Amps Each
e) Double pole 240 V , 100 Amps Each
f) Double pole 240 V , 125 Amps Each
g) Four Pole 415 V , 32 Amps Each
h) Four Pole 415 V , 40 Amps Each
i) Four Pole 415 V , 63 Amps Each
j) Four Pole 415 V , 80 Amps Each
k) Four Pole 415 V , 100 Amps Each
l) Four Pole 415 V , 125 Amps Each

8 RCCB-s , Double Pole 240 Volts


a) 25 Amps , 30 mA Each
BOQ AND RATE ANALYSIS FOR DISTRIBUTION BOARDS

Sl No. Item Description UOM Qty

b) 40 Amps , 30 mA Each
c) 63 Amps , 30 mA Each
d) 100 Amps , 30 mA Each
e) 25 Amps , 100 mA Each
f) 40 Amps , 100 mA Each
g) 63 Amps , 100 mA Each
h) 100 Amps , 100 mA Each
i) 25 Amps , 300 mA Each
j) 40 Amps , 300 mA Each
k) 63 Amps , 300 mA Each
l) 100 Amps , 300 mA Each

9 RCCB-s , Four Pole 415 Volts


a) 25 Amps , 30 mA Each
b) 40 Amps , 30 mA Each
c) 63 Amps , 30 mA Each
d) 100 Amps , 30 mA Each
e) 25 Amps , 100 mA Each
f) 40 Amps , 100 mA Each
g) 63 Amps , 100 mA Each 268.00
h) 100 Amps , 100 mA Each 134.00
i) 25 Amps , 300 mA Each
j) 40 Amps , 300 mA Each
k) 63 Amps , 300 mA Each
l) 100 Amps , 300 mA Each
Each
10 MCB Enclosure Each
a) 2P Enclosure Each 719.00
b) 3P Enclosure Each
c) 4P Enclosure Each
d) 6P Enclosure Each
e) 8P Enclosure Each

11 Metal Plug & Sockets


a) 20A SP Industrial Socket DB with neutral & SP MCB Each 100
b) 20A TP Industrial Socket DB with neutral & MCB Each 86
c) 32 A TP Industrial Socket DB with neutral & MCB Each 91

11 Blanking Plate Each 128


BOQ AND RATE ANALYSIS FOR FANS

Sl No. Item Description UOM Total

As per Tender Drawings

1 BEE 5 star rated, ceiling fans of the following sizes with Brush Less Direct Current -
(BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos.
canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9,
Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350
RPM (tolerance as per IS : 374-2019), THD less than 10%, Provision of remote or
electronic regulator unit for speed control and all remaining accessories including
safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC
Supply, earthing etc. complete as required.

a) 1200 mm sweep Sets 1,024.00

b) 900 mm sweep Sets 2,304.00

c) 1400 mm Sweep Sets -

-
2 300 mm dia heavy duty metallic exhaust fans with finz and birds screen Sets 576.00
QUANTITIES OF LIGHT FIXTURES & FANS
Drawing Title Name of Location Quantities of Light Fixtures Quantities of Fans

Wall Mounted Wall Mounted Spot Light Ceiling Mounted Recess Mounted Down Fully diffused recessed 1200 mm Wall Mirror Light 600 mm Wall 1200 mm Sweep 900 mm Exhaust Fans
Tube Light Tube Light Tube Light Light mounted 1'X4' LED Light Bracket Light Ceiling Fans Sweep
(Normal) (Emergency) Fixture @ Ceiling Level luminaire with high Ceiling Fans
transmitive diffuser--43W

2ND BASEMENT Stair & Store Room area Tower 1 12 14


2.5 Mtr Wide Passage Tower 1 56
4.0 Mtr Wide Passage Tower 1 8
Service Lobbies Tower 1 4
Lift Lobbies Areas , Tower 1 44
Parking & Other Areas , Tower 1 73 2
Stair & Store Room area Tower 2 12 14
2.5 Mtr Wide Passage Tower 2 56
4.0 Mtr Wide Passage Tower 2 8
Service Lobbies Tower 2 4
Lift Lobbies Areas , Tower 2 44
Parking & Other Areas , Tower 2 73 2
Parking Slots other than tower areas 374
6.0 Mtr Drive Way 153 31

1ST BASEMENT Stair & Store Room area Tower 1 12 14


2.5 Mtr Wide Passage Tower 1 56
4.0 Mtr Wide Passage Tower 1 8
Service Lobbies Tower 1 4
Lift Lobbies Areas , Tower 1 44
Parking & Other Areas , Tower 1 73 2
Stair & Store Room area Tower 2 12 14
2.5 Mtr Wide Passage Tower 2 56
4.0 Mtr Wide Passage Tower 2 8
Service Lobbies Tower 2 4
Lift Lobbies Areas , Tower 2 44
Parking & Other Areas , Tower 2 73 2
Parking Slots other than tower areas 374
6.0 Mtr Drive Way 153 31

GROUND FLOOR Stairs Areas Tower 1 14


Area Near Store Room, Tower 1 12 2
Ladies Toilet, Tower 1 20 2
Gents Toilet, Tower 1 16 8
2.5 Mtr Wide Passage Tower 1 40
4.0 Mtr Wide Passage Tower 1 8
Lift Lobbies Areas , Tower 1 44
Service Lobbies Tower 1 2
Stairs Areas Tower 2 14
Area Near Store Room, Tower 2 12 2
Ladies Toilet, Tower 2 20 2
Gents Toilet, Tower 2 16 8
2.5 Mtr Wide Passage Tower 2 40
4.0 Mtr Wide Passage Tower 2 8
Lift Lobbies Areas , Tower 2 44
Service Lobbies Tower 2 2
Reception 40
6.0 & 7.5 Mtr Driveways 135
Visitor Parking 350

1st TO 5th TYPICAL FLOOR Stairs Areas Tower 1 70


PLAN Area Near Store Room, Tower 1 60 20
2.5 Mtr Wide Passage Tower 1 280
Ladies Toilets, Tower 1 180 20 10
Gents Toilets, Tower 1 150 70
Offices , Tower 1 1580 560 80 160 340 80
Stairs Areas Tower 2 70
Area Near Store Room, Tower 2 60 20
2.5 Mtr Wide Passage Tower 2 280
Ladies Toilets, Tower 2 180 20 10
Gents Toilets, Tower 2 150 70
Offices , Tower 2 1580 560 80 160 380 80

6th TO 16th TYPICAL FLOOR Stairs Areas Tower 1 154


Area Near Store Room, Tower 1 132 44
2.5 Mtr Wide Passage Tower 1 616
Ladies Toilets, Tower 1 396 44 22
Gents Toilets, Tower 1 330 154
Offices , Tower 1 3476 1232 176 352 836 176
Stairs Areas Tower 2 154
Area Near Store Room, Tower 2 132 44
2.5 Mtr Wide Passage Tower 2 616
Ladies Toilets, Tower 2 396 44 22
Gents Toilets, Tower 2 330 154
Offices , Tower 2 3476 1232 176 352 748 176

Total 2307 70 2884 56 12428 3584 596 512 1024 2304 576
CABLE TRAY

Sl No. Description of Items UOM Qty as per


Consultant's BOQ

1 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 1408
thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner.
2 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 896
thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner.
3 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 288
thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner.
4 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 160
thick) GI sheet of 400 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner.
5 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 64
thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner.
6 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 64
thick) GI sheet of 600 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner..
7 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 64
thick) GI sheet of 750 mm width & 75 mm height complete with necessary coupler plates &
hardware in approved manner..
8 Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm Rmt 192
thick) GI sheet of 1000 mm width & 75 mm height complete with necessary coupler plates
& hardware in approved manner..
9 Hot deeped Galvanised cover suitable for perforated type Cable tray manufactured from Rmt 12
16 swg (1.6 mm thick) GI sheet of 150 mm width & 15 mm height complete with necessary
hardware in approved manner.
10 Hot deeped Galvanised cover suitable for perforated type Cable tray manufactured from Rmt 12
16 swg (1.6 mm thick) GI sheet of 200 mm width & 15 mm height complete with necessary
hardware in approved manner.
11 Hot deeped Galvanised cover suitable for perforated type Cable tray manufactured from Rmt 12
16 swg (1.6 mm thick) GI sheet of 300 mm width & 15 mm height complete with necessary
hardware in approved manner.
12 Hot deeped Galvanised cover suitable for perforated type Cable tray manufactured from Rmt 24
16 swg (1.6 mm thick) GI sheet of 400 mm width & 15 mm height complete with necessary
hardwere in approved manner.
13 Hot deeped Galvanised cover suitable for perforated type Cable tray manufactured from Rmt 24
16 swg (1.6 mm thick) GI sheet of 500 mm width & 15 mm height complete with necessary
hardware in approved manner
14 Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm Rmt 48
thick) GI sheet of 600 mm width & 100 mm height comprising all required standard
Acessories..
15 Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm Rmt 50
thick) GI sheet of 750 mm width & 100 mm height comprising all required standard
acessories..
16 Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm Rmt 75
thick) GI sheet of 1000 mm width & 100 mm height comprising all required standard
acessories..
DETAIL OF UPS
Item No Discription of Items Unit Qty As per
Consultant's BOQ

1 Supplying, installing, testing and commissioning of 800 VA to 900 VA Digital Set 4


pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT)
technology single phase 230V,50 Hz complete as per specification .
2 Supplying, installing, testing and commissioning of 1400 VA to 1600 VA Digital Set 8
pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT)
technology single phase 230V,50 Hz complete as per specification
3 Supplying, installing, testing and commissioning of 2500 VA Digital pure sine Set 8
wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology
single phase 230V,50 Hz complete as per specification
4 Supplying, installing, testing and commissioning of 700 VAdigital pure sine wave Set 16
inverter based on Insulated GateBipolar Transistor (IGBT) technology single
phase 230V,50Hz complete as per specification
5 Installation & commissioning of UPS, 3 x 3, 200 kVA @ 25°C, 3 Phase, 415 V, IP- Set 3
20, including Transformer with Parallel Connection Cable (8M) for 200 kVA with
Inbuilt Output Transformer with UPS, Battery Circuit Breaker -External ,
Approved make SMF 12V battery, with 30 min Backup, Battery Rack,Battery IRIT,
Nyvin Cable of Suitable Size ,UPS to battery standard distance 10 mtr) &
Uninyvin cable of suitable size for (2W+1SB) UPS system
6 Installation & commissioning of UPS, 3 x 3, 120 kVA @ 25°C, 3 Phase, 415 V, IP- Set 3
20, with Transformer including Parallel Connection Cable (8M) for 120 kVA ,
Inbuilt Output Transformer with UPS ,Battery Circuit Breaker -External, make
SMF 12V battery with 30 min Backup, Battery Rack ,Battery IRIT, Nyvin Cable
of Suitable Size, (UPS to battery standard distance 10 mtr) & Uninyvin cable
suitable for (2W+1SB) UPS system
7 Installation & commissioning of UPS, 3 x 3, 60 kVA @ 25°C, 3 Phase, 415 V, IP-20, Set 2
with Transformer including Parallel Connection Cable (8M) for 60 kVA , Inbuilt
Output Transformer with UPS ,Battery Circuit Breaker -External, make SMF 12V
battery with 30 min Backup, Battery Rack ,Battery IRIT, Nyvin Cable of Suitable
Size, (UPS to battery standard distance 10 mtr) & Uninyvin cable suitable for
UPS system
8 Installation & commissioning of UPS, 3 x 3, 40 kVA @ 25°C, 3 Phase, 415 V, IP-20, Set 2
with Transformer including Parallel Connection Cable (8M) for 40 kVA , Inbuilt
Output Transformer with UPS ,Battery Circuit Breaker -External, make SMF 12V
battery with 30 min Backup, Battery Rack ,Battery IRIT, Nyvin Cable of Suitable
Size, (UPS to battery standard distance 10 mtr) & Uninyvin cable suitable for
UPS system
DISRIBUTION TRANSFORMERS
Item No Discription of Items Unit Qty

1 Supplying, installation testing and commissioning of 2000 KVA, Set 3


Outdoor type, distribution transformer, suitable for 3 phase,
50HZ, AC supply, Dyn 11 vector group,core made of good
quality CRGO, windings made of copper wound with approved
danger and arc flash signages and with all components as
mentioned in BOQ, specifications and SLD and complete as
required.

Voltage Grade : 33 /0.433 KV


Type Of Cooling : ONAN
Type of Tap Changer : On Load Tap Changer
(+10% to - 15% in step of 1.5%)
Allowable Loss : As per latest ECBC
As per ECBC Plus
DG SET
Item No

1
2
DG SET
Discription of Items

Providing, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set alongwith having
Prime Power Rating of following KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for
50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings:Diesel Engine Diesel engine 4
stroke water cooled, selectric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40
Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10%
over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all
the required accessories.Engine mounted Instrument Panel fitted with and having digital display for
following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure
indication(iv) Lubrication oil temperature indication(v) Battery charging indication(vi) RPM
indication(vii) Over speed indication(viii) Low lub. Oil trip indication(ix) Engine Hours
indicationAlternator Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz,
AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall
be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR
conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation ( Class-H
insulation and temp. rise limited to class-F)
Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of
MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation
and vibration isolation arrangement as per recommendations of manufacturer.
Fuel Tank: Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete
with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of
suitable dia. Complete with valves, level indications & accessories as required as per specifications.
Exhaust System: Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.
Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and
arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp. Hour
capacity lead acid type) as required as per specifications.
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine &
alternator, extraction, discharging hot air in to the atmosphere as per specifications.Fabricating, Installing,
Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for
following KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and
energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH &
provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF
panel to diesel engine and elsewhere if required, all complete and inter locking including the
following:Auto/Manual/Test/Off selector switchEmergency push buttons Suitable CTs Energy analyser
unit to indicate current voltage frequency power factor and KWH Indicating lamps for load on mains and
load on set Fuse for instruments Battery charger, complete with transformer/ rectifier, D.C. voltmeter and
ammeter, selector switch for trickle, off and boost and current adjustment.Main supply failure monitor
Supply failure timer Restoration timer Control unit with three impulse automatic engine start/stop and
failure to start lockout. Impulse counter with locking and reset facility.ON/OFF/Control circuit switch with
indicatorAudio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii)
Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning

1010 KVA
Supplying and fixing exhaust gas piping of suitable dia. welded black MS, B Class pipe
conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and
clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool,50
mm thick wiremesh & aluminum cladding etc., as required as per specifications.
Unit Qty

Sets 3
Lot 3
BOQ FOR RISING MAINS & BUS DUCTS

Item No Discription of Items UOM Qty As per


SLD

1 Following capacity Sandwich Type Rising Mains / Bus Trunking for use on 3 phase 4 wire 415 volts,
50Hz A.C. supply with metal clad enclosure having IP-65 (for outdoor) and IP-54 (for indoor) rating
after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in
convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at,
nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each
floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous
earthing with 2 Nos aluminium strip of size 50X6mm (one on each side) including, G.I. clamping
brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
(Isc - 50 KA/Sec)

a) 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 16
Straight Length – Indoor ( IP 55 )
b) 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr
Straight Length – Outdoor ( IP 65 with canopy )
c) 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 24
Straight Length – Indoor ( IP 55 )
d) 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 304
Straight Length – Indoor ( IP 55 )
e) 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 24
Straight Length – Indoor ( IP 55 )
f) 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 24
Straight Length – Indoor ( IP 55 )
g) 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 144
Straight Length – Indoor ( IP 55 )
h) 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Mtr 24
Straight Length – Indoor ( IP 55 )

2 3200 A , 415 V End feed Unit suitable for above rising main and 3200 A 4P ACB , but without ACB Sets 4
2000 A , 415 V End feed Unit suitable for above rising main and 3200 A 4P ACB , but without ACB Sets 4

3 Distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with
powder coating on existing rising mains complete as required, suitable for mounting 4P MCCB-s (TM
Release ), but without MCCB-s
a) 250 A Sets 136

4 415 V Sandwich Bus Duct , 3P-4W , Aluminium Conductor


a) 3200 Amps with Accessories Rmtr 90
b) 1600 Amps with Accessories Rmtr 75

5 3200 Amps ACB , 4P, 415V , EDO Sets 4


2000 Amps ACB , 4P, 415V , EDO Sets 4
6 250 A , MCCB 4P,415 Volt Sets 136
LT PANELS BOQ
Sl No. Description of Items UOM Quantity

1 SITC of DG Synchronisation cum Main LT Panel , with modular construction IP42(Indoor) and -
IP55(Outdoor), factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel
of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated
from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners
wherever required, having vibration free structure chemically treated with seven tank process or better
before painting for surface treatment and powder coated in approved shade, with suitable electrolytic
grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with
short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX
50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common
earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid
conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated
FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing
following switch gears and as per specification

Incomer for Transformers : 3200 Amp EDO 4P ACB , 415 Volt , MP Release with ATS--- 3 Nos Sets 1.00
Incomer for DG-s : 1600 Amp EDO 4P ACB , 415 Volt , MP Release --- 3 Nos
Incomer for Solars : 800 A MCCB , 415Volt , MP release--- 2 Nos
ATS : 2500 A 4P --3 Nos , 800 A 4P -- 1 Nos

Busbar : 3 Ph, 4 Wire ,7500 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC
FRLS Sleeves
Outgoing Feeders : * 1600 Amp 4P ACB EDO -- 3 Nos (APFC Panels)
* 1250 Amps 4P ACB EDO -- 3+4 Nos (Common Area Building Panels & 4 for stack
parking panels)
* 3200 Amps 4P ACB EDO --- 4 Nos ( For Rising Main)
* 1250 Amps 4P ACB EDO --- 2 Nos ( For UPS Input Panel)
* 800 Amps 4P MCCB , MP Release ----- 2 Nos ( For Fire Fighting Panel
& Ventilation Panel)

Meters : Digital MF Meters for all Incomers and O/G Feeders with suitable rating Metering & Protection
CT-s
Under Voltage, REF, Master Trip, Trip Circuit Supervision to be provided

-
2 SITC of LT Capacitor Panels of following capacities with required APFC relays, capacitors, detuned Sets 3.00
reactors and other accessories as per specifications.

800 KVAr

3 SITC of Common Area Building Panels with following details ; Sets 2.00

Incomer : 415 Volt , 1250 Amps ACB , EDO , Micro Processor Release --- 2 Nos with 1 nos 1250 Amps ATS .
Multifunction Meters for both incomers with CT-s of suitable ratings.
Bus Bar : 1600 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : * 125 Amps 4P MCCB with TM Release -- 18 Nos ( Floor Panels)
* 630 Amps 4P MCCB with MP Release -- 2 Nos (Elevators)
* 160 Amps 4P MCCB with TM Release ---- 3 Nos (Basement Lighting &
Power)
* 630 Amps 4P MCCB with MP Release ---- 1 Nos (Plumbing Panels)
*

-
4 SITC of Fire Pump Panels with following details ; Sets 1.00

Incomer : 415 Volt , 800 Amps MCCB , Micro Processor Release --- 1 Nos
Multifunction Meters for incomer with CT-s of suitable ratings.
Bus Bar : 1000 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : * 250 Amps 4P MCCB with TM Release and Star Delta Starter -- 5 Nos
* 100 Amps 4P MCCB with TM Release and Star Delta Starter ---- 1 Nos
* 63 Amps 4P MCCB with TM Release and Star Delta Starter ---- 5 Nos

-
5 SITC of UPS Input Panel as per following details : Sets 1.00

Incomers : 415 Volt , 1250 Amps ACB EDO , MP Release --- 2 Nos
Multifunction Meters for incomer with CT-s of suitable ratings.

Bus Bar : 2000 Amps Hi Grade Electrolytic Akuminium Conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : * 320 Amps 4P MCCB with MP Release -- 3 Nos


* 200 Amps 4P MCCB with TM Release ----3 Nos
* 125 Amps 4P MCCB with TM Release ---- 6 Nos

-
6 SITC of UPS Output Panel as per following details : Sets 1.00

Incomers : * 320 Amps 4P MCCB with MP Release -- 3 Nos


* 200 Amps 4P MCCB with TM Release ----3 Nos
* 125 Amps 4P MCCB with TM Release ---- 6 Nos
Multifunction Meters for incomers with CT-s of suitable ratings.

Bus Bar : 2000 Amps Hi Grade Electrolytic Akuminium Conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : 2000 Amps 4P ACB, EDO with MP Release --2 Nos

-
Sl No. Description of Items UOM Quantity

7 SITC of Elevator Panels as per following details : Sets 2.00

Incomer : 415 Volt , 400 Amps MCCB , Micro Processor Release --- 1 Nos
Multifunction Meters for incomer with CT-s of suitable ratings.
Bus Bar : 1000 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : 100 Amps 4P MCB , C Curve , 10 KA--- 10 Nos

-
8 SITC of Elevator Individual Panels as per following details : Sets 16.00

Incomer : 415 Volt , 100 Amps MCCB , Micro Processor Release --- 1 Nos
Digital Ammeter , Voltmeter and indication lamps
Current transformers of suitable capacities.

Bus Bar : 150 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : * 63A 4P RCBO--2 Nos


* 16A DP RCBO with 1.5 KVA Inverter ---- 1 Nos
* 16A DP RCBO ---- 2 Nos

-
9 SITC of Floor LT Panels for Lighting as per following details : 3.00

Incomer : 415 Volt , 100 Amps MCCB , Micro Processor Release --- 1 Nos
Digital Ammeter , Voltmeter and indication lamps
Current transformers of suitable capacities.
Bus Bar : 150 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : 6-32 Amps DP MCBs --- 16 Nos

10 SITC of Floor LT Panels for Lighting & Power as per following details : 41.00

Incomer : 415 Volt , 320 Amps MCCB , Micro Processor Release --- 2 Nos
415 V, 320A ATS ---2 Nos
Digital Ammeter , Voltmeter and indication lamps
Current transformers of suitable capacities.

Bus Bar : 300 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : *6-32 Amps DP MCBs --- 6 Nos


* 40-63 Amps DP MCB-s ----10 Nos
* 63 Amps FP MCB-s-----10

11 SITC of Floor LT Panels for UPS as per following details : 41.00

Incomer : 415 Volt , 320 Amps MCCB , Micro Processor Release --- 2 Nos
415 V, 320A ATS ---1 Nos
Digital Ammeter , Voltmeter and indication lamps
Current transformers of suitable capacities.

Bus Bar : 300 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : *6-32 Amps DP MCBs --- 6 Nos


* 40-63 Amps DP MCB-s ----10 Nos
* 63 Amps FP MCB-s-----10

12 SITC of Ventilation Panel as per following details : 1.00

Incomer : 415 Volt , 800 Amps MCCB , Micro Processor Release --- 2 Nos with 800 A ATS
Digital Ammeter , Voltmeter and indication lamps
Current transformers of suitable capacities.
Bus Bar : 1000 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : 320 Amps 4P MCCB with MP Release -- 5 Nos

-
13 SITC of Plumbing with following details ; 1.00

Incomer : 415 Volt , 630 Amps MCCB , Micro Processor Release --- 1 Nos
Multifunction Meters for incomer with CT-s of suitable ratings.
Bus Bar : 800 Amps Hi Grade Electrolytic Aluminium conductor with heat shrinkable PVC FRLS Sleeves

Outgoing feeders : * 160 Amps 4P MCCB with TM Release -- 2 Nos


* 100 Amps 4P MCCB with TM Release ---- 1 Nos
* 63 Amps 4P MCCB with TM Release ---- 7 Nos

Note : No Updated SLD covering the full scope was available , BOQ was prepared based on DBR & Pre-Bid Replies.
BOQ OF HT PANELS

Sl No.

2
3
BOQ OF HT PANELS

Description of Items

Note : HT Panels shall be internal arc tested for 1 sec at rated fault current value 33kV HT Panel- (Single VCB Board Near H
Meter )
Incoming : Surge arrester (1 No.) 30kV,10kA, metal oxide varistor type surge arrestor suitable for both lightning and switc
surges,complete with its bushings and earthing terminations etc. as required.
Line PT (1 No.) 2 core line mounted, fixed type,3 phase, cast resin, potential transformer with rated turn/voltage ratio of
33000/(1.732):110/(1.732) ,rated burden of 50 VA, 33kV rated inbuilt primary side fuse,110V rated secondary and tertiary si
fuses complete with isolating plugs as required. Core 1 : CL 0.5, star connected with neutral grounded for metering and
indications. Core 2 : CL 3P, star connected with neutral grounded for protections.
VCB (1 No.) 33kV, 50Hz, 1250A, 3P, 31.5kA for 3 sec rated SCADA compatible, drawout type, roll on floor design VCB brea
panel with suitable breaker trolleys, 110 volts DC closing and tripping coils, 110 Volts DC spring charging motor, locking m
inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts, do
interlocking, racking interlocking and any other controls or interlocks as described in specifications or SLD, solenoids, TNC
, earth truck complete as required.
Indication lamps 1 Sets of LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue)
1 Sets of LED type Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, service, spring charge,TCH,
truck on)
1 Sets of LED type Indication lamps for DC fail suitable for 230V AC supply Numeric relay (1 No.) Numeric relay module w
LCD dislpay having following inbuilt

protection functions : under voltage, over voltage, frequency , trip circuit supervision, phase sequence,instantaneous
overcurrent,instantaneous earth fault,overcurrent and earth fault, suitable to record and store at least 100 events with date
time stamping with last five fault records stored in nonvolatile memory and with self supervision function, 4 spare digital b
2inputs
number
and334 KV 1250A
spare VCB
digital Incomer
output within
contacts 1 Numbers ofthose
addition to Outgoing VCBas1250A
required per andtheRMU.
scheme, SCADA compatible, along wi
Necessary
3No. 33kV Relays , Protective
,100/1A, device current
10VA, CL-5P10 and indicating lamps complete
transformers, to be included
as required.
Electro-mechanical relay Hinged armature type electromechanical master trip (lockout) relay complete with assembly- 1 N
Hinged armature type dc fail relay complete with assembly- 1 No.
PT fuse failure relay - 1 No EM-6400 equivalent multifunction meter with inbuilt selector switch and RS-485 port etc. comp
per specifications, compatibility to SCADA along with 3No. 33kV ,100/1A, 10VA, CL-0.5 current transformer as required. -
0-33000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 1 Nos.
Emergency trip button on front door at an accessible height -1 Nos. Selector type auto / manual switch -1 Nos. 230 volt, 50H
operated Hooter with noise level of 80db at every 3 metres with acknowledge and reset push button-1 Nos. 16-window
microprocessor based annunciation panel with visual LED indicator suitable for 230V AC complete as required. - 1 Nos.
110V DC Power Pack Busbar : Busbar (1 Set - 3P + E) Busbar made up of electrolytic grade high conductivity copper in requ
cross section and suitable for handling 33 KV, TP 50 Hz, 1250 A, 31.5 kA for 3 sec of required length and cross sectional area
Note : Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approva
busbar size has to be as per the approved GA drawing.
33kV HT Panel- ESS- (1 I/C + 4 O/G)
Incoming : Surge arrester (12No.) 30kV,10kA, metal oxide varistor type surge arrestor suitable for both lightning and switc
surges,complete with its bushings and earthing terminations etc. as required.

Line PT (2 No.) 2 core line mounted, fixed type,3 phase, cast resin, potential transformer with rated turn/voltage ratio of
33000/(1.732):110/(1.732) ,rated burden of 50 VA, 33kV rated inbuilt primary side fuse,110V rated secondary and tertiary si
fuses complete with isolating plugs as required. Core 1 : CL 0.5, star connected with neutral grounded for metering and
indications.Core 2 : CL 3P, star connected with neutral grounded for protections.

VCB (2No.) 33kV, 50Hz, 1250A, 3P, 31.5kA for 3 sec rated SCADA compatible, drawout type, roll on floor design VCB brea
panel with suitable breaker trolleys, 110 volts DC closing and tripping coils, 110 Volts DC spring charging motor, locking m
inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spare NC contacts, do
interlocking, racking interlocking and any other controls or interlocks as described in specifications or SLD, solenoids, TNC
, earth truck complete as required.

Indication lamps 1 Sets of LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue)1 Sets of LED ty
Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, service, spring charge,TCH, earth truck on)1 Se
LED type Indication lamps for DC fail suitable for 230V AC supply Numeric relay (1 No.) Numeric relay module with LCD
dislpay having following inbuilt protection functions :under voltage, over voltage, frequency , trip circuit supervision, phas
sequence,instantaneous overcurrent,instantaneous earth fault,overcurrent and earth fault, suitable to record and store at lea
events with date and time stamping with last five fault records stored in nonvolatile memory and with self supervision
function, 4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, SC
compatible, along with 3No. 33kV ,100/1A, 10VA, CL-5P10 current transformers, complete as required.

Electro-mechanical relay Hinged armature type electromechanical master trip (lockout) relay complete with assembly- 1
No.Hinged armature type dc fail relay complete with assembly- 1 No.PT fuse failure relay - 1 No.Metering EM-6400 equiva
multifunction meter with inbuilt selector switch and RS-485 port etc. complete as per specifications, compatibility to SCAD
along with 3No. 33kV ,100/1A, 10VA, CL-0.5 current transformer as required. -

1 Nos.0-33000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 1 Nos.Emergency trip button on front door a
accessible height -1 Nos.Selector type auto / manual switch -1 Nos.230 volt, 50Hz,AC operated Hooter with noise leve
80db at every 3 metres with acknowledge and reset push button-1 Nos. 16-window microprocessor based annunciation pan
with visual LED indicator suitable for 230V AC complete as required. -
1 Nos. 110V DC Power Pack
Busbar : Busbar (1 Set - 3P + E)Busbar made up of electrolytic grade high conductivity copper in required cross section an
suitable for handling 33 KV, TP 50 Hz, 1650 A, 31.5 kA for 3 sec of required length and cross sectional area.
Note : Concerning vendor needs to furnish the busbar calculations (for both phase and earth bus) at the time of GA approva
busbar size has to be as per the approved GA drawing.

Outgoing : VCB (4 Nos.) 33kV, 50Hz, 1250A, 3P, 31.5kA for 3 sec rated SCADA compatible, drawout type, roll on floor desig
VCB breaker panel with suitable breaker trolleys, 110 volts DC closing and tripping coils, 110 Volts DC spring charging mot
locking magnet, inbuilt antipumping relay, potential free NO & NC contacts required in addition to 4 spare NO and 4 spar
contacts, door interlocking, racking interlocking and any other controls or interlocks as described in specifications or SLD,
solenoids, TNC switch , earth truck complete as required.
110V DC / 110V AC operated earth truck suitable for 33kV cable -

1 No.Indication lamps 5 Sets of LED type Indication lamps for breaker, suitable for 110V DC supply (on, off, trip, test, servi
spring charge,TCH, earth truck on)
5 Sets of LED type Indication lamps for DC fail suitable for 230V AC supply
Numeric relay Numeric relay module with LCD dislpay having following inbuilt protection functions & suitable to reco
and store at least 100 events with date and time with last five fault records stored in nonvolatile memory and with self
supervision function,
4 spare digital binary inputs and 4 spare digital output contacts in addition to those required as per the scheme, SCAD
compatible, breaker control (on/off) complete as required.
Note : Numeric relays shall have a provision of by-passing the second harmonic current during transformer switching oper
so that feed breaker does not trip during transformer switching.
under voltage, over voltage, frequency , trip circuit supervision phase sequence,instantaneous overcurrent,instantaneous ea
fault,overcurrent and earth fault along with 3No. 33kV ,50/1A, 10VA, CL-5P10 current transformers, complete as required.
Nos.Numeric relay module (for safe tripping of transformer's 33kV feed breaker) with LCD dislpay having following inbu
protection functions :High winding temperature with 3No. 33kV ,50/1A, 10VA, CL-5P10 current transformers, complete as
required. -
2 Nos.Numerical Relay module for REF protection of Transformer - 2 Nos.Electro-mechanical relay Hinged armature type
electromechanical master trip (lockout) relay complete with assembly- 2 Nos.Hinged armature type dc fail relay complete w
assembly- 2 Nos.Metering EM-6400 equivalent multifunction meter with inbuilt selector switch and RS-485 port etc. comple
per specifications, compatibility to SCADA along with 3No. 33kV ,50/1A, 10VA, CL-0.5 current transformer as required. - 2
Nos.0-33000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 2 Nos.Emergency trip button on front door at
accessible height -2 Nos.Selector type auto / manual switch -2 Nos.230 volt, 50Hz,AC operated Hooter with noise level of 8
every 3 metres with acknowledge and reset push button- 2 Nos.16-window microprocessor based annunciation panel w
visual LED indicator complete as per specifications and schedule as required.- 2 Nos.
UOM Qty

job 1.000

job 1.000
job 1.000
EXTERNAL LIGHTING
Item No Discription of Items

1 Supply of 7 Mtr high hot dip galvanised octagonal poles with 130 mm bottom
A/F & 70 mm top A/F made up of 3mm thk. HT sheet alongwith base plate
of size (220X220X12) mm thk, and foundation bolts of suitable sizes and
quantities (Single Arm)

2 100W LED Street Light Fixture (BRP409 LED115 CW SLC FG PSU GR V2) with
dimmable driver
3 LED Bollard 7W ( Philips BCP400 LED09 D CW PSU GR S1)
4 LED Post Top Light Fixtures with 1 Mtr Decorative Poles (Philips BGP300
LED28 757 PSU PC IN S1)
5 LED Bush/Ground Light (Philips BBP211 LED90/WW 2W 12V 30D)
6 LED Step Lights (Philips BWG150 LED50/WW PSU 220-240V IP67 7043)
7 16M high mast shaft in two sections suitable for 55m/sec wind speed, with
raising lowering system comprising, head frame, luminaries carriage suitable
to install 08 nos luminaries in symmetrical arrangement, drum winch, 5mm
diameter SS wire rope, trailing cable,connector, integral power tool motor,
manual handle, junction box, lightening finial including Supply & fixing of
foundation bolts manufactured from special steel along with nuts, washers,
anchor plate and common template.
8 200W LED Flood Light Fixture for High Mast (Philips BVP184 LED196 CW
FG WB 200W PSU)
9 Feeder Pillar for High Mast
10 Supply of Following Size armoured cables (1.1 KV Grade, XLPE, AL
Conductor)
a) 4C X 16 Sqmm
b) 3.5C X 35 Sqmm
c) 4C X 10 Sqmm
11 Laying of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size direct in ground including
excavation, sand cushioning,
protective covering and refilling the trench etc as required.

Upto 35 sq. Mm
12 Laying of one number additional PVC insulated and PVC sheathed /
XLPE power cable of 1.1 kV grade of following size direct in ground in
the same trench in one tier horizontal formation including excavation,
sand cushioning, protective covering and refilling the trench etc. as
required.
Upto 35 sq. Mm
13 Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 1.1 kV grade of following size on cable tray / trough ducts / through Hume
Pipe etc.

14 LED Facade Light Fixtures (WIPRO LF20-442-060-57-G2 , 350W)


G
Unit Qty

Sets 39

Sets 39

Sets 82
Sets 49

Sets 100
Sets 27
Sets 1

Sets 8

Sets 1

Mtr 2785
Mtr 173
Mtr 1383

Mtr 633

Mtr 2253
Mtr 213

Sets 22
TENTATIVE POWER CABLE SCHEDULE

Sl No. Description Of Items UOM Qty

1 Supplying 33 KV (Earthed) grade, XLPE insulated, heavy duty


FRLS type, armoured cables suitable for 33kV, 50Hz, AC system
with inner and outer PVC sheath, outer sheath provided with
FRLS insulation, galvanised steel flat armouring and with all
components as mentioned in BOQ, specifications and SLD,
complete as required.
of the following sizes

3C X 300 Sqmm Mtr 280

2 Supplying following 1.1kV grade, XLPE insulated, FRLS type,


heavy duty armoured cables suitable for 415V, 50Hz, AC system,
with inner and outer PVC sheath, outer sheath provided with FRLS
insulation, galvanised steel armouring (round (W) or flat (F) as
mentioned) and with all components as mentioned in BOQ,
specifications, complete as required.

a) 3.5C X 400 Sqmm Mtr 5227


b) 3.5C X 300 Sqmm Mtr 6668

c) 3.5C X 240 Sqmm Mtr 1578


d) 3.5C X 185 Sqmm Mtr 960
e) 3.5C X 150 Sqmm Mtr
f) 3.5C X 120 Sqmm Mtr 180
g) 3.5C X 95 Sqmm Mtr 297
h) 3.5C X 70 Sqmm Mtr 4296
i) 3.5C X 50 Sqmm Mtr 2540
j) 3.5C X 35 Sqmm Mtr
k) 3.5C X 25 Sqmm Mtr 0
l) 4C X 16 Sqmm Mtr
m) 4C X 10 Sqmm Mtr
n) 4C X 6 Sqmm Cu Mtr 850
o) 4C X 4 Sqmm Cu Mtr 425
p) 3C X 4 Sqmm Cu Mtr 1156
q) 12C X 2.5 Sqmm Cu Mtr 840
r) 9C X 2.5 Sqmm Cu Mtr 623
TOTAL
Cable Laying BOQ
Sl No. Description of Items UOM Qty

1 One run of 33 KV 3CX300 Sqmm directly in ground with Mtr 151


excavation, sand filling , brick protection
2 One additional run of 33 KV 3CX300 Sqmm directly in Mtr 101
ground with excavation, sand filling , brick protection
3 One run of 33 KV 3CX300 Sqmm on cable tray / through Mtr 28
duct / through hume pipe etc.

4 One run of 1.1 KV power cable of following sizes directly in


ground with excavation, sand filling , brick protection

a) 3.5C X 400 Sqmm Mtr 784


b) 3.5C X 300 Sqmm Mtr 827
c) 3.5C X 240 Sqmm Mtr 292

d) 3.5C X 185 Sqmm Mtr


e) 3.5C X 120 Sqmm Mtr
f) 3.5C X 95 Sqmm Mtr
g) 3.5C X 70 Sqmm Mtr
h) 3.5C X 50 Sqmm Mtr
i) 3.5C X 35 Sqmm Mtr
j) 3.5C X 25 Sqmm Mtr

5 One additional run of 1.1 KV power cable of following sizes


directly in ground with excavation, sand filling , brick
protection
a) 3.5C X 400 Sqmm Mtr 3904
b) 3.5C X 300 Sqmm Mtr 4993
c) 3.5C X 240 Sqmm Mtr 875
d) 3.5C X 185 Sqmm Mtr
e) 3.5C X 120 Sqmm Mtr
f) 3.5C X 95 Sqmm Mtr
g) 3.5C X 70 Sqmm Mtr
h) 3.5C X 50 Sqmm Mtr
i) 3.5C X 35 Sqmm Mtr
j) 3.5C X 25 Sqmm Mtr

6 Laying of Following sizes of cables on wall / cable trays /


through ducts / through hume pipes etc. With proper
dressing.
a) 3.5C X 400 Sqmm Mtr 524
b) 3.5C X 300 Sqmm Mtr 429
c) 3.5C X 240 Sqmm Mtr 411
d) 3.5C X 185 Sqmm Mtr 960
e) 3.5C X 120 Sqmm Mtr 180
f) 3.5C X 95 Sqmm Mtr 297
g) 3.5C X 70 Sqmm Mtr 4296
h) 3.5C X 50 Sqmm Mtr 2540
i) 3.5C X 35 Sqmm Mtr
j) 3.5C X 25 Sqmm Mtr 392

TOTAL
HT AND LT CABLE TERMINATIONS BOQ

Sl No. Description of Items UOM Qty Inside


Building

1 33 KV Indoor Heat Shrinkable End Termination ---3C X 300 Set


Sqmm
2 33 KV outdoor Heat Shrinkable End Termination ---3C X 300 Set
Sqmm
3 End Termination of following sizes LT Cables with single
compression type glands and solderless / Aluminium and
Copper lugs
a) 3.5C X 400 Sqmm Set 10
b) 3.5C X 300 Sqmm Set
c) 3.5C X 240 Sqmm Set 4
d) 3.5C X 185 Sqmm Set 78
e) 3.5C X 120 Sqmm Set
f) 3.5C X 95 Sqmm Set 4
g) 3.5C X 70 Sqmm Set 128
h) 3.5C X 50 Sqmm Set 162
i) 3.5C X 35 Sqmm Set
j) 3.5C X 25 Sqmm Set 4

You might also like