After the OSN Tributary Board Is Equipped with


Lower Order Services, the NE Timeslot Mode
Cannot Be Switched
Publication Date: 2019-07-03 | Views: 312 | Downloads: 0 | Author: hexiaojun 17442 | Document ID: EKB0000129000

Contents
Issue Description

Alarm Information

Handling Process

Root Cause

Suggestions

Issue Description

A piece of the OSN 3500 interconnects with the equipment from other vendor. When a user configures 2
Mbit/s services on the T2000V1R8, the user feeds back that the timeslot number of Huawei OSN 3500 is
inconsistent with that of L equipment, thus bringing trouble for service configuration. Huawei engineer changes
the timeslot mode of the OSN 3500 NE to L mode, but the timeslot mode still cannot be switched.

Alarm Information

The timeslot mode of the OSN 3500 NE cannot be switched.

https://support.huawei.com/enterprise/en/knowledge/EKB0000129000 1/4
11/19/2020 After the OSN Tributary Board Is Equipped with Lower Order Services, the NE Timeslot Mode Cannot Be Switched- Huawei

Handling Process
 MENU  
1. Check the timeslot mode on the T2000 to ensure it is Huawei mode.
2. Clear lower order services and then re-set the timeslot mode.
3. After changing the VC12 timeslot number policy with the command line, load or query NE attributes on the
T2000 as soon as possible.

Root Cause

1. When a piece of the transmission equipment from Huawei interconnects with that from other vendor to
add/drop 2 Mbit/s tributary services, problems on interconnection and maintenance are often resulted due to
different timeslot signs.
2. In the T2000V1R8 service configuration view, you can see the current mode: "numbering mode (Huawei
mode)" or "interleaving mode ".
3. Change the VC12 timeslot number policy on the T2000. The timeslot is displayed on the T2000 differently,
but the NE is unaffected. To change the NE, set related values using the command line. The T2000 does not
provide a function entry. After settings through the command line, load or query NE attributes on the T2000 as
soon as possible.
4. You can set the timeslot mode in the existing software. Two commands ":cfg-set-servicemode" and "cfg-get-
servicemode" are for query. The command parameters for setting the timeslot mode are slot and line; namely,
"timeslot mode" and "line mode" or "Huawei mode" and "interleaving mode". The default mode is Huawei
mode.
5. Restriction: If a 2 Mbit/s tributary board is equipped with lower order services, the timeslot mode cannot be
changed.

Suggestions

In case of similar interconnection requirements, change the timeslot mode during commissioning to avoid this
problem.

See also case in chinese:SC0000151004

Previous:
IMA service functioning problem of Next: FAQ-Built-in WDM Technology of the OptiX
interconnection of OSN1500B and company OSN 1500
N NodeB

Comments and Reply

https://support.huawei.com/enterprise/en/knowledge/EKB0000129000 2/4
11/19/2020 After the OSN Tributary Board Is Equipped with Lower Order Services, the NE Timeslot Mode Cannot Be Switched- Huawei

 0MENU
Average rating: Points 0 ratings Average problem solving rate: 0%
 

Provide feedback on this document to earn bonus points and redeem gifts. My Points
(/enterprisemysupport/mysupport#click=feedbackscore) | Redeem Gifts
(https://forum.huawei.com/enterprise/en/plugin.php?id=auction&action=search&extype=8)

Feedback:

Huawei may contact you to help you resolve the problem as soon as possible. Please enter your contact
information:

Name: Email: Tel:

Company:

* I have read and agree to the Privacy Policy (/enterprise/en/privacy-policy)of Huawei.I know that my personal
information will be stored on a server in China.

*Please rate this document: very poor excellent

Did you find what you were looking for? Yes No Just Browsing

Submit
Feedback Add to Favorites

Related resources

Documentation

Software Download

Bulletins

Tools

Related searches

By Author

https://support.huawei.com/enterprise/en/knowledge/EKB0000129000 3/4
11/19/2020 After the OSN Tributary Board Is Equipped with Lower Order Services, the NE Timeslot Mode Cannot Be Switched- Huawei

Help us to improve
 MENU  
Write an article

Follow Us 
About Huawei 
How to Buy 
Partner 
Resources 
Others 
Enterpise App

Copyright © 2020 Huawei Technologies Co., Ltd. All rights reserved.

Privacy | Terms of use | RSS Subscribe | Sitemap

https://support.huawei.com/enterprise/en/knowledge/EKB0000129000 4/4

You might also like