You are on page 1of 2

SAFE

FIELD DENSITY TEST


(Core Cutter Method)
Project:- Provisional Head Quarter of CTD (Technical Block) Near Jallo Park Lahore

Ref Lab#

Sr.
Description Test Trial Nos.
No.
TP-1 TP-2 TP-3 TP-4 TP-5
Assistant Assistant
Comette Technical Diractor Diractor Server
1 Location of Test Pit
Room Branch Technical Technical Room
Room Room
2 Layyer No. TOP TOP TOP TOP TOP

3 Date of Testing 12/1/2019. 12/1/2019. 12/1/2019. 12/1/2019. 12/1/2019.

4 Wt. of Core Cutter + wet. Soil 3080 2812 2814 3078 2834

5 Wt. of Core Cutter only 990 990 990 990 990

6 Wt. of Wet. Soil 2090 1822 1824 2088 1844

7 Factor of Cutter 1026 1026 1026 1026 1026

8 Wet. Density in g/cc 2.037 1.776 1.778 2.035 1.797

9 Moisture Content %age 10.9 7.2 7.8 11.8 8.4

10 Dry density in g/cc 1.837 1.657 1.649 1.820 1.658

11 Maximum Lab density in g/cc 1.92 1.92 1.92 1.92 1.92

12 Compaction % age 95.7 86.3 85.9 94.8 86.4

Tested by:-_______________________________ Checked by:__________________________