Proceedings CEEM'201S/HangZhou

Method of pulse function fitting based on the corona


current measurement data

Hu Xiaofeng Zhang Yue, Wang Lei, Liu Hao


Institute of Electrostatic and Electromagnetic Protection Institute of Electrostatic and Electromagnetic Protection
Mechanical Engineering College Mechanical Engineering College
Shijiazhuang, China Shijiazhuang, China
Snowfox2270@163.com

Abstract-As an important gas discharge form, corona


discharge can generate electromagnetic radiation field which will II. ANALYTICAL EXPRESSION OF CORONA CURRENT
interfere with the electronic devices and systems. Calculation of
According to the theoretical calculation and experiment
electromagnetic radiation field requires quantitative research of
results, corona current has fast rising edge and short duration
corona pulse current and analytical expression. According to the
time[5-8]. It is known that the mathematic expression of corona
research situation abroad that the corona current was fitted
current is needed to put forward to analytically calculate the
using double-exponential function and Gaussian function, a
corona radiation field. At present, the double exponent
corona pulse current function is proposed in the paper. It is
expression is mostly used. Deimdorfer and Uman put forward
researched based on the physical processes of corona discharge
current excitation. And the fitting parameters and analytic of -60
the DU model when they studied the space-time distribution of
kV negative corona discharge current are deduced based on the lighting channel current, in which, the channel current consists
measurement data and compared with the double-exponential of put forward and breakdown current, the corona current is
fitting result. The result shows that time derivative at zero time of expressed by double exponent function, which shows as
fitting expression corona current pulse function is zero. And the following[9]:
waveform frontier is consistent with the measured waveform,
which is better than double-exponential function. The proposed
i(O, t) = IBD[1-exp(-tl r,)f exp(-t I rJI 17
(1)
fitting method is suitable for describing the corona discharge +Idexp(-t I a) -exp(-t I b)]
pulse current waveform.
Where, the last term is the corona current expression, Ie is
Keywords-corona discharge, corona current, pulse function, the current amplitude, a and b are constant.
jitting expression
In 2005, S. K. Nayak and M. 1. Thomas put forward the put
forward based on double exponent function when they studied
I. INTRODUCTION
the EMI of high voltage transportation lines[lO]. Xiao D. P. et
Corona discharge is one of the most important gas al. also put forward the put forward based on double exponent
discharge form. When corona discharge generate on the tip of function when they studied the EMI of high voltage
the conductor, the conductor will produce a corona discharge transportation lines[ll].
current. Corona discharge has a deep rising edge and radiate
After corona discharge occurs, the current cannot change
intense electromagnetic field[1-4]. The electromagnetic field
suddenly, therefore, the corona current should be ° at t=0. The
will interfere with the electronic devices and systems.
corona pulse current and its derivative are important factors for
Therefore, the corona discharge radiated field calculation is an
transient electromagnetic field, the radiation field cannot
important research content in the electricity fields. To acquire
change suddenly as the corona discharge occurs, and the
effective calculation results of corona discharge radiated field,
current derivative should be 0, therefore, the mathematic
the accurate corona discharge pulse current expression is need.
expression of corona current should firstly meet the
The corona current is generally expressed by double­
requirement that the current and its derivative are 0. The double
exponential function. To calculate corona discharge radiated
exponent is ° at t=0, whereas, its derivative is not ° at t=0,
field conveniently, a novel corona discharge current pulse
therefore, it is not fit with the physics process of corona current.
function is proposed in the paper. By comparing the
measurement results and fitting results, the pulse function is
consistent with the generated physics process of corona III. CORONA CURRENT EXPERIMENT SETUP AND
discharge current. This research is a good foundation for MEASUREMENT DATA
corona discharge radiated field calculation. The corona current is related to the voltage and polarity of
the electrode, it is also affected by the shape, material and
conductive plate arrangement of the corona electrode[12]. The

398

Authorized licensed use limited to: Universidad de Costa Rica (UCR). Downloaded on October 30,2022 at 15:04:28 UTC from IEEE Xplore. Restrictions apply.
Proceedings CEEM'201S/HangZhou

corona pulse current of tip conductor is tested as shown In diet) -1 ( P-I


Fig. l[13]. 10(7172 ) [l-exp -t I 71 ) ]
dt
-- =

(3)
Tip conductor exp(-tI 7z } [(p72 + 71) exp(-t171) - 71]
k
p ( - l ) p I tt I 2
f(t) = oi(t)dt= - loa . exp(- ktltl- tltz}
k�O k!(p- k ! ) tI + kt2
Metal ball

en
Insulating
(4 )
bracket As seen in (3), dietI
) dt = 0 at t=0. It is known that the
dipoles have current term, the differential and integration of
current, which can be easily calculated by pulse function.
By adjusting the parameters, we have obtained the current
waveform expression of -60kV corona test data, which shows
Figure 1 test setup of corona pulse current of tip conductor as following:
In the experiment, the tip conductor is fixed to the
insulating holder, and grounded by high-voltage insulated wire.
The voltage of the DC high voltage source is raised from - i(t) = 18(1- e -[ 11.04 ) 2 e -[ 15.04 (5)
60kVand +60kV. The tip conductor is moved to the charging Where, t is in ns.
metal ball from far to near, until corona discharge occurs. The
Fig. 3 shows the comparison of double exponent function,
corona pulse current is measured by the oscilloscope and
pulse function and test results. Fig. 4 shows the extended pulse
current probe. The temperature and humidity during the
rising edge, in which, pulse function is in red, double exponent
experiment are 23°C and 65% respectively. When. The corona
function is in blue, and test results are in black. As seen in Fig.
discharge occurs when the voltage of the DC high voltage 3 and Fig. 4, the derivative of pulse function is 0 at 0 ns, and it
source is raised to +60kV and the distance between the tip rising edge fits better than that of double exponent function.
conductor and the voltage source is 90 mm. The tested typical
pulse current waveform is shown in Fig. 2. 12
- test results
006 10
_. double exponent
- - pulse function
0.05

«
E
0.04 ""

003
::::

002
� ·2

0.01 10 12 14 16 18 20
Uns

Figure 3 Comparison of fit waveforms


.001
0 20 40 60 80 1 00 120 140 1 60 180 200
Time/ns
12

10

Figure 2 Typical current waveform of negative corona .......


.

. ... . ..... "'


IV. FITTING EXPRESSION OF THE CORONA CURRENT BASED -
..
ON PULSE FUNCTION - test results
- - double exponent
Pulse function can express corona current waveform, _. pulse function
because it is 0 at t=O, and its integration and differential are
·2
easy to calculate. We can adjust its parameters to fit the pulse
current waveform well. Due to mostly contributing to the
Uns
radiation field, the first pulse can be expressed by the single
pulse function, as following:
Figure 4 Comparison of fore edge of waveforms
2
i(t)=Io(1-e-tlr'Ye-tlr (2)
V. CONCLUSION
By calculated, the differential and integration expression of To calculate corona discharge radiated field conveniently, a
pulse function show as following respectively [14]: novel corona discharge current pulse function is proposed

399

Authorized licensed use limited to: Universidad de Costa Rica (UCR). Downloaded on October 30,2022 at 15:04:28 UTC from IEEE Xplore. Restrictions apply.
Proceedings CEEM'201S/HangZhou

based on the physical processes of corona discharge current [5] [5] Zhu Yi-min, Kong Xian-gpeng. Current-voltage
excitation in the paper. By building test systems of pulse characteristics of multi-needles-to-plate corona
fischarge[J]. High Voltage Apparatus, 2006,32(1):57-58.
current excited by corona discharging, current waveform is
[6] [6] Luo Lailong, Xu Xiaoying. Electric Field Distributing
tested and recorded. By comparing the measurement results
and Voltage Current Characteristic in Corona Region [1J.
and fitting results, the pulse function is consistent with the Journal of Wuhan University of Technology,
generated physics process of corona discharge current. In the 2006,32(1):57-58.
conclusion, the fitting parameters and analytic of -60 kV [7] [7] S. Ishigami and T. Iwasaki. Two-source model of
negative corona discharge current are deduced based on the transient electromagnetic fields generated by electrostatic
measurement data and compared with the double-exponential discharge[C]. International Symposium on
Electromagnetic Compatibility, Tokyo, 1999: 130-133.
fitting result. The result shows that time derivative at zero time
of fitting expression corona current pulse function is zero. And [8] [8] Chen Shixiu, Sun Youlin. Characteristics of
electromagnetic wave radiated from corona discharge[CJ.
the waveform frontier is consistent with the measured International Symposium on ElectromagnetIc
waveform, which is better than double-exponential function. Compatibility, Montreal, 2001, 1279-1282.
The proposed fitting method is suitable for describing the [9] [9] G. Diendorfer and M.A. Uman. An imp roved return
corona discharge pulse current waveform. model with specified channel-base current[JJ. J. Geophys.
Res. , 1990, 95(D9): 13621�13644.
[10] [10] S.K. Nayak, M. Joy Thomas. A Novel Technique for
ACKNOWLEDGMENT
the Computation of Radiated EMI due to Corona on HV
The authors wish to thank the project supported by National Transmission LinesrJ]. IEEE EMC International
Symposium, 2003,2:738-742.
Natural Science Foundation of China (61172035).
[11] rl1] Xiao Dong-Ping, He Wei, Xie Peng-Ju, el al.
Study on Corona Discharge Characteristic of High Voltage
Transmission Line and Calculation of Its Electromagnetic
REFERENCES Radiation Field[J]. Power System Technology. 2007,
31(21): 52-55.
[1] rl] Y.Zebboudj. Measurements of current and electric
[12] [121 M. Davila, J. L. Naredo. Analyzing transients on
field distributions beneath a positive DC wire-to-plane
muTticonductor lines with corona[Cl IEEEIPES
corona using a liner b� ased probe[1]. lEE Proc.-Sci. Meas.
Transmission & Distribution Conference & Expositions,
Technol. ,2000, 147(2). 74-80.
2004:236-242.
[2] [2] A.Kasdi, H. Yala and Y. Zebboudj. Finite element
[13] [13] Hu Xiao-Feng, Liu Shang-He, Wu Zhan-Cheng, et al.
analysis of bipolar coronarC]. Internationl conference on
Measurement and analysis of impulse current Clue to
solid dielectrics, Toulouse,France, 2004.
corona on the ESD brush[J]. High Voltage Apparatus,
[3] [3] M. Abdel-Salam, S. Abdel-Sattar. Calculation of 2007,33(9):171-174.
corona V-I characteristics of monopolar bundles using the
[14] [141 He Qi-yuan. Study on the immunity testing methods
charge simulation method[Jl. IEEE Tans. On Electrical
ana energy coupling mechanism of electrostatic
insulation, 1989,24(4): 669-679.
discharge[DJ. ShiJiazhuang Mechanical Engineering
[4] [4] R. G. Olsen. Radio noise due to corona on a College Doctoral DIssertation, 2007.
multiconductor power line above a dissipative earth[J].
IEEE Trans. On Power Delivery, 1988,3(1): 272-287.