You are on page 1of 2

28701-NCD520002+ Uen Rev B

Fiber Optic Splitter Shelf


2 to 64 Ports Rack Mountable Splitters

Application Description
The splitter shelf comprises of a metal chassis for Configurations from 1x4 to 1x64 use Planar
19” rack mounting and fiber optic splitter devices. Lightwawe Circuit (PLC) splitters. 1x2
The optical splitters provide uniform division of an configurations are based on Fused Biconic Tapers
optical signal from one input fiber ports to multiple (FBT). All components have thermally stable
output ports. broadband performance.

The splitters are design to meet the requirements The splitter components are designed according to
for a wide range of fiber optic communications Telcordia GR-1209, GR-1221 as well as IEC
systems. The broadband performance makes them 67153-031-3/-6.
especially suitable for PON FTTX networks.
The splitter shelf is available in configurations with
Low loss under extreme environmental conditions multiples of splitters from 1x2 to1x64, see ordering
ensures stable operation. Thermally stable and number table. Standard connector option is
compact design allows these shelves to be installed SC/APC. Configuration examples of front panels
into Central Office (CO) racks as well as in outside are shown below.
plant Fiber Distribution Hubs (FDH).

Features 1x16

- 1x2 to 1x64 standard configurations


- Broadband operating wavelength performance 1x32
- Low insertion loss
- Low back reflection
4x(1x4)
- Low PDL (Polarization Dependent Loss)
- Low WDL (Wavelength Dependent Loss)
- Low TDL (Temperature Dependent Loss) 8x(1x2)

- High output uniformity


- Stable optical performance
8x(1x4)
- According to Telcordia GR-1209 and GR-1221
- 1U, 19” and ETSI rack mountable
16x(1x2)
Fiber Optic Splitter Shelf

Specifications Dimensions
19” and ETSI, 1U rack mountable unit
Optical Properties WxDxH ........................... 410x195x44 mm
Operating Wavelength ....
1260 ~ 1360, 1450 ~ 1625 nm Conformance
Directivity ........................ >55dB ITU-T G.652 D
Return Loss .................... >55dB Telcordia GR-1209
Maximum input power..... 500mW Telcordia GR-1221
Max attenuation .............. see table below IEC 67153-031-3/-6
Max uniformity .................. see table below IEC 61754-4
PDL ................................ <0,3dB IEC 61754-6
IEC 61754-20
The optical properties refer to maximum values, valid for the RoHS Directive
entire operating wavelength band and temperature range. At
specific wavelengths and temperatures, better performance may
be obtained. Detailed information is available upon request.
Ordering information
Connector Performance Product numbers are shown in the table below.
SC/APC
Max attenuation .............. ≤0,30dB Splitter shelves with 2xN configurations, other
Return Loss .................... >65dB connector options and performance grades are
available upon request.
The maximum connector attenuation is included in the total
insertion loss of the splitter unit, see table below.

Temperature and Humidity


operation......................... –40 to +70ºC
transport and storage...... –40 to +70ºC
storage rel. humidity ....... 20-95 (%RH)

W
D

Ordering Number Table


Insertion
No of Splitters / Uniformity
Product No. Loss*
Split Ratio (max) dB
(max) dB
NCD 520 0022 1x16 14,8 1,5

NCD 520 0023 1x32 18,0 1,7

NCD 520 0024 8x (1x4) 8,2 0,8

NCD 520 0025 4x (1x4) 8,2 0,8

NCD 520 0026 16x (1x2) 4,6 0,8

NCD 520 0027 8x (1x2) 4,6 0,8

NCD 520 0028 4x (1x8) 11,6 1,0

NCD 520 0029 1x64 21,6 2,5

* Including maximum connector loss, wavelength dependent loss, polarization dependent


loss and temperature dependent loss defined by the operation wavelength band and the
operation temperature range.

28701-NCD520002+ Uen Rev B 2008-01-23 © Ericsson Network Technologies AB 2 (2)


www.ericsson.com Public