Professional Documents
Culture Documents
1900/1950
1950
VOYAGE DATA RECORDER (VDR)
SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)
INSTALLATION
MANUAL
(Software Part)
Revision history
Revision Contents Date
1st 10-Aug-2014
nd
2 ࣭Add "4.2 Download VDR Initial Configuration File" 7-Jun-2016
࣭Add the description about HBT output interval and SFI List to "4.4.1 Own
Ship Information"
࣭Add the description about tool to "4.4.4 Network"
࣭Add "4.5.4 Data Acquisition Unit (DAU) Setup"
࣭Add remote maintenance setting procedure to "4.5.5 Remote Maintenance
Connection Setup"
࣭Add image recording setting procedure and setting example in "4.6
IMAGE"
࣭Correct connection port in "5.2 Setup for Real Time Monitor (CYC-826)"
(Wrong: User port, Right: EXT port)
࣭Add "6.6 NETWORK"
࣭Add the description of FGB model change to "10.4 Setting of Frame
Grabber Unit NWP-69 (FGBUTIL)"
࣭Add "10.7 Download Software for Annual Performance Test
(APTDOWNLOAD)"
࣭Correction of erroneous description and add USB serial cable in the
remarks of the "11.3 EPIRB Tester (Tron Unidec)"
࣭Add "Annex 1 Connection Interface of Remote Maintenance Equipment"
࣭Add "Annex 2 IP Address / SFI of Remote Maintenance Equipment"
࣭Correction of erroneous description
7ZPNA4436B
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
ii
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Index
1. Summary............................................................................................................................................... 1
2. Start and End ........................................................................................................................................ 3
2.1. Start ............................................................................................................................................... 3
2.2. End ................................................................................................................................................. 4
3. Screen Configuration ............................................................................................................................ 5
3.1. Home Screen ................................................................................................................................. 5
3.1.1. Work Tab ................................................................................................................................ 5
3.1.2. Common Button...................................................................................................................... 5
3.2. Work Item....................................................................................................................................... 6
3.2.1. Installation Tab ....................................................................................................................... 6
3.2.2. Option Tab .............................................................................................................................. 6
3.2.3. Log Tab................................................................................................................................... 6
3.2.4. Remote Maintenance Tab ...................................................................................................... 6
3.2.5. Operation Panel Tab .............................................................................................................. 6
3.2.6. Software Update Tab ............................................................................................................. 7
3.3. List Screen ..................................................................................................................................... 7
3.3.1. Diagnosis (Diagnosis Lamp) .................................................................................................. 7
3.3.2. Entry Status (Entry Lamp) ...................................................................................................... 7
3.3.3. Visual Checking (Checking Lamp) ......................................................................................... 8
3.3.4. Alert Status ............................................................................................................................. 8
3.4. Setup Screen ................................................................................................................................. 8
4. Installation Setup / Operation Check (Installation Tab) ........................................................................ 9
4.1. Installation Work Flow.................................................................................................................. 10
4.2. Download VDR Initial Configuration File ..................................................................................... 11
4.3. Upload VDR Configuration File ................................................................................................... 12
4.4. SYSTEM ...................................................................................................................................... 13
4.4.1. Own Ship Information ........................................................................................................... 13
4.4.2. Replacement Parts ............................................................................................................... 15
4.4.3. Unit ....................................................................................................................................... 16
4.4.4. Network................................................................................................................................. 17
4.4.5. Configuration File ................................................................................................................. 21
4.4.6. History................................................................................................................................... 22
4.5. SENSOR ...................................................................................................................................... 23
4.5.1. Serial Connection Setup....................................................................................................... 23
4.5.2. Digital Signal Converter (DSC) Connection Setup .............................................................. 31
4.5.3. LAN Connection Setup ......................................................................................................... 40
4.5.4. Data Acquisition Unit (DAU) Setup ...................................................................................... 43
iii
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
iv
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
v
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
vi
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1. Summary
JCY-1900 maintenance software is applications software for PCs made in the investigation of setting,
operation check, the malfunction cause at the time of shipment setting, the inspection in the factory and
the equipment, the maintenance on the ship.
1) OS
・Windows 7 ... IE9 or more, Firefox or Chrome
・Windows 8 ... IE10 or more, Firefox or Chrome
2) Assigning of IP address
In case of DHCP
Set "Obtain an IP address automatically" to maintenance PC.
In JCY-1900 VDR, DHCP server is incorporated. IP address is assigned from VDR automatically.
In case of fixed IP
Assign the following IP address and Default gateway to maintenance PC.
- IP address ... 192.168.110.200
- Subnet mask ... 255.255.255.0
- Default gateway ... 192.168.110.3
1
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
DATA port
2
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2.1. Start
1) Start a browser, and input "192.168.110.3" into an address.
2) Input the following with Login screen.
・Name
・Company
・Password (by an all small letter "jrcvdr")
3
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2.2. End
1) Click [Log out] to end.
[Logout]
2) Returns to Login screen. Click [X] of the screen top right corner to close browser.
4
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3. Screen Configuration
3.1.2.1. [Home]
Returns to Home screen.
3.1.2.2. [Previous]
Returns to previous screen.
5
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3.1.2.3. [Reboot]
After setting with [Set], in order to apply the setup, rebooting is necessary. When rebooting is
necessary, [Home] blinks in red ( ), require a reboot. In such a case, click [Reboot]. When
completing reboot, [Home] returns to normal ( ).
3.1.2.4. [Mute]
When alarm occurs, a buzzer sounds in OPU. Buzzer can be stopped by clicking [Mute]. [Mute] is
light blue ( ) while mute.
6
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
7
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Set] [Reboot]
If [Reboot] blinks in red, the setup is not applied. Please make sure to reboot by clicking
Remarks
[Reboot].
8
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Item Description
1. SYSTEM Setting of system information, upload/download VDR
configuration file(vdrinfo.dat)
2. SENSOR Setting of sensor connection, sentence, and remote
maintenance, real-time monitoring
3. IMAGE Setting of radar and ECDIS connection, real-time monitoring
4. AUDIO Setting of microphone and VHF transceiver connection, real-time
monitoring
5. RECORDING MEDIUM Setting the capsules and the internal storage
6. REPORT Download VDR configuration file (vdrinfo.dat) and operation
status file
9
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Complete
At the time of shipment, only minimum settings have been carried out. VDR
configuration file of each ship in accordance with ship's installation configuration is
Remarks created separately, and posted on MS Web. See "4.2 Download VDR Initial
Configuration File", download the target ship's configuration file from MS Web before
boarding the ship.
After completing installation, please make sure to save report file into the ship list of MS
Remarks Web.
About REPORT function, refer to "4.9 REPORT".
10
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Fixed protective
capsule Float-free capsule Radar connection
No. connection (*1) connection (*1) (*2) VDR configuration file
1 Available Available Available vdrinfo_FPC_FFC_Radar.dat
2 Available Unavailable Available vdrinfo_FPC_Radar.dat
3 Unavailable Available Available vdrinfo_FFC_Radar.dat
4 Available Available Unavailable vdrinfo_FPC_FFC_No-Radar.dat
5 Available Unavailable Unavailable vdrinfo_FPC_No-Radar.dat
6 Unavailable Available Unavailable vdrinfo_FFC_No-Radar.dat
(*1) Capsule connection available ... Recorded data is stored to the capsules.
Capsule connection unavailable ... Recorded data is not stored to the capsules.
(*2) Radar connection available ... If no radar image is recorded, an alert indicates on VDR.
Radar connection unavailable ... VDR does not indicate the alert about radar image recording.
11
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Dialog box that prompts VDR reboot appears. Click [OK], then reboot VDR. After that, refer to
Section 4.4 and later, execute installation setup.
12
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.4. SYSTEM
Select order of Home screen, [Installation] tab and [1. SYSTEM].
1) Ship Name
Input the ship's name.
2) IMO No.
Input the IMO number.
13
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) Call Sign
Input the call sign.
4) MMSI
Input the MMSI number.
5) Type Appr.
Input the type approval number and approval country / organization as follows.
・BABT-MED000066
6) Order
Input shipping order of JRC.
7) Q'ty
Input quantity of main engine, propeller, side thruster and rudder, and distance of keel-trans. These
information are necessary for Playback software and Real Time Monitor software.
1) SFI
Set VDR SFI (System Function ID). Normally it is not necessary to change.
2) HBT Output Interval
Set HBT sentence output interval. Normally it is not necessary to change.
14
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Expiration Date
Input expiration date of battery and fan according to the following table.
15
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) Operation Time
VDR counts operation time (unit: hour), and indicates it. Clear the time with [Clear] after replacing.
3) Diagnosis
When expiration date comes within 1 year, ● (red) is displayed.
4.4.3. Unit
Unit Serial Number Parts Serial Number Maintenance Number Software Update Date
16
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) Maintenance Number
Maintenance number of each equipment can be confirmed.
3) Software Updated Date
The date when software was installed is displayed.
4.4.4. Network
Set VDR network settings.
17
JRC Network(Default:172.16.60.xxx/16, (or 192.168.60.xxx/24)) VDR Network(192.168.110.xxx/24)
Recording Control Unit : NDV-1900
Current/Old model RADAR/ECDIS (RGB signal connection) Float-free capsule Fixed capsule
NDH-339 NDH-338
192.168.110.4 192.168.110.2
(or 192.168.60.3)
MCB:192.168.110.3
MCB:172.16.60.3
MCB:192.168.0.4
User Network (Default:192.168.000.xxx/24)
Frame Grabber Unit Frame Grabber Unit Frame Grabber Unit
NWP-69 NWP-69 NWP-69
172.16.60.5 172.16.60.6 172.16.60.7
Real-time Monitor
VDR Network(192.168.110.xxx/24)
DHCP(192.168.110.201-204)
DHCP(192.168.110.201-204)
User Network (Default:192.168.000.xxx/24)
・
・・
OPU
Reserve
Fixed Capsule
Float-free Capsule
JRC Network -1
JRC Network -2
JRC Network -3
JRC Network -4
DATA PORT DHCP(192.168.110.201-204)
User Network
J511-1
J511-2
J511-3
J511-4
J513
J514
J515
J516
J517
J512
18
X-Band X-Band S-Band
Main ECDIS Backup ECDIS
Radar Radar Radar
Ship’s Network
・・・
Serial
IEC61162-1/-2
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.4.4.1. IP Setting
VDR IPs in USER-LAN, VDR-LAN, JRC-LAN can be confirmed, if required, IP address can be
changed. And then IP address for VDR-LAN can't be changed.
19
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1 2 3 4
JRC-LAN Port
4.4.4.3. Tool
Run ping / traceroute command to the target IP address, and display the results. Use this function to
verify that the equipment is connected correctly.
20
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Command
Select command.
2) IP Address
Set destination IP address.
3) Use ICMP Echo Request (When traceroute is selected)
・Use ICMP Echo Request : ☑
・Use UDP packet : □
21
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.4.6. History
History of factory setup and onboard setup can be confirmed.
Factory setup (upper) Onboard setup (lower)
22
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.5. SENSOR
Select order of Home screen, [Installation] tab and [2. SENSOR].
23
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Serial Port CH
Select connection CH.
2) Sensor Type
Select type of sensor. If there is no appropriate type, select "Other".
3) Use
・Connect : ☑
・Disconnect : □
Remarks To make the channel unconnected with keeping the detailed setup, remove ✓ in Use.
24
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Equipment
Input equipment name. (e.g. GPS, Doppler Log)
2) Model
Input model of the equipment.
3) Manufacturer
Input manufacturer name.
4) Serial No.
Input serial number. If it is uncertain, input "Unknown".
5) Version
Input software version. If it is unknown, input "Unknown".
6) Comment
Input comment. If there is nothing special, input "None".
25
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Sensor Type
Default data of sentence filter, Data, Watch and Interval are set by equipment selected in Sensor
Type automatically.
2) Data
Select record item from pull down menu. If not found record item, select "Other(Any)".
3) Sentence filter
Sentence ID of record item selected in Data is set. If select "Other(Any)", sentence filter becomes
blank. Input sentence ID according to the following.
4) Watch
Select valid or invalid of max interval watch for reception. If invalid is set, receive error doesn't
occur even if doesn't receive sentence for max interval time. Valid is set as default.
・Max interval watch valid : ☑
・Max interval watch invalid : □
26
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Sentence filter can be input up to 16 characters. If there is uncertain letter in talker ID,
etc, "?" can be used as wild card. It is not necessary to set sentence header (e.g. "$",
"!").
Example) Sensor outputs $GPZDA...
GPZDA ... Recorded
??ZDA ... Recorded
Remarks AAZDA ... Not recorded
??ZDB ... Not recorded
? ... Recorded(*)
????? ... Recorded(*)
(*) Because all of the input sentence is recorded unconditionally, please do not normally
use.
5) Interval
Set max interval time for reception. If sentence doesn't receive for max interval time, receive error
occurs. 60 seconds is set as default.
6) VDR
Record valid / invalid to VDR is set. It is set as valid automatically, cannot be changed.
・Record valid : ☑
・Record invalid : □
7) Opt.
This function is not available now.
8) Fwd.
This function is not available now.
9) Remote Maintenance
Sets Remote Maintenance. Refer to "4.5.5 Remote Maintenance Connection Setup" for more
detail.
27
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Raw Data
All sentences from all equipments can be monitored. Unrecorded sentence in VDR is displayed
also.
You can save the acquired content to a text file by clicking [Save] button.
If displayed characters in line monitor are strange, the causes are the following. Please
check the cause.
・Polarity of cable connection is reversed
・Protocols such as baud rates are mismatch
Remarks
2) Sentence
Latest recorded sentence per Sentence filters are displayed by clicking [Latest Log] button. If there
is no problem with displayed content, select [Good] on Check. Otherwise select [Fail] on check,
and input the detail information in Comment.
Input contents of this item is output in the report file. Refer to "4.9 REPORT" for more information.
28
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
When Main GPS and Sub GPS are switched and connected to a sensor channel, select switch
method.
・Auto
If sentence data is not received from Main GPS, Sub GPS is selected automatically. If data from
Main GPS is recovered, Main GPS is selected automatically.
・Dry Contact
Switch GPS depending on VDR dry contact status. Input dry contact signal from GPS switch unit to
VDR PI3. In addition, select dry contact status (Open/Close) at that time of switching Main GPS or
Sub GPS.
・INS
Switch GPS depending on INS selection. This function is not available now.
29
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Length
X
0
Load Lines
Width T: Tropic
S: Summer
W: Winter
30
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Serial Port CH
Select connection CH. Channel that can connect DSC is 19, 20, 23 or 24.
2) Sensor Type
Select DSCx or DSCx+A/D.
・Analog Converting Board (CEF-60) is installed : DSCx+A/D
・Analog Converting Board (CEF-60) is not installed : DSCx
3) Use
・Connect : ☑
・Disconnect : □
31
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
32
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
If DSCx or DSCx+A/D is set on Sensor Type, contents of Recording Data tab is automatically set. It is
not necessary to change.
33
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
34
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Upload File
Click [Browse], and select setup file. Then, click [Upload], the file is transferred and programmed.
DSC setting file can be created on Maintenance Software. See "10.3 Setting of NCT-82/83 DSU
(DSCSETUP)" for more detail.
2) Download File
DSC setup file can be readout by clicking [Download] button.
35
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Connection Setting
Check Use.
2) Identification Tab
Input equipment information of analog signal source.
Please select appropriate signal type on Contents field. If there is no appropriate type, select
"Other".
36
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) A/D Tab-Calculate
Conversion fixed number of analog signal is calculated according to the following procedure.
37
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) A/D Tab-A/D CH
Calculated fixed numbers are displayed. Select unit and input range from combo box.
- Unit - Range
No. Unit No. Range
1 none 1 ±1V
2 deg 2 ±5V
3 min-1 3 ±10V
4 rpm 4 4-20mA
5 m/s
6 km/s
7 knots
38
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
P3-x P1-x
P2-x RANGE USE INPUT
±5V / 4-20mA
NO 4-20
±10V
39
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
List shows connection status. Set the connection in the detail setup screen.
・Connect : ☑
・Disconnect : □
Connection
40
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) LAN No.
Select connection CH.
2) Sensor Type
Select type of sensor. If there is no appropriate type, select "Other".
3) Use
・Connect : ☑
・Disconnect : □
Remarks To make the channel unconnected with keeping the detailed setup, remove ✓ in Use.
41
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Equipment
Input equipment name. (e.g. GPS, Doppler Log)
2) Model
Input model of the equipment.
3) Manufacturer
Input manufacturer name.
4) Serial No.
Input serial number. If it is uncertain, input "Unknown".
5) Version
Input software version. If it is unknown, input "Unknown".
6) Comment
Input comment. If there is nothing special, input "None".
7) Sensor Source
It is displayed when [Advanced] check at the bottom right of the screen is ON.
Select "Single" or "Multiple". Refer to "4.5.7 INS Connection".
8) Source SFI
Input equipment source SFI.
To specify multiple SFIs, turn on the [Advanced] check.
Up to 4 types can be set.
9) Destination SFI
If check ON, only the sentence with target destination SFI is recorded. Set refer to the following
setting example.
42
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
AMS(SFI:II0001)
AMS(SFI:II0001).
AMS(SFI:II0001)
43
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
44
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
S3
TB13
S4
CD48
J8111
45
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
46
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
If DAU installation setup screen cannot open, check the following items:
・Whether rotary switch S3 and DIP switch S4 is set as described above
・Whether IP address of PC is set correctly
Remarks
・Whether J8111 port of DAU and PC are correctly connected with LAN cable
If it does not work, refer to "4.5.4.2 DAU Setting Initialization", initialize the setting of
DAU.
7) Click [IP Address Settings] on left menu. IP address setting screen is displayed.
Enter the red part of above figure according to the following table. Setting other than red do not
need to change.
47
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Enter the red part of above figure according to the following table. Setting other than red do not
need to change.
48
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
9) Click [Transmission Group Settings] on left menu. Transmission group setting screen is
displayed.
Change the red part of above figure according to the following table. Setting other than red do
not need to change.
49
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
10) Click [Receive Group Settings] on left menu. Receive group setting screen is displayed.
Change the red part of above figure according to the following table. Setting other than red do
not need to change.
Receive Group(*)
No System Function 1 MISC 3 SATD
12 GYRO interface ☑ □
(*) Same setting regardless of DAU No..
50
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11) Click [Serial Interface Settings] on left menu. Serial interface setting screen is displayed.
Change each settings according to the connected equipment. Baud rate that can be set for each
port are as follows:
51
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
12) Click [Save Settings] on left menu. Then, save settings by clicking [Apply] button.
13) Setup is completed. Turn off power of DAU, then disconnect maintenance PC. After that,
connect DAU to JRC-LAN(Main) port of RCU.
14) If DAU No.2 or later is installed, perform initial setup in the same procedure.
2) Check that LED CD48 is lit in red. Then, turn off power of DAU.
3) Restore jumper TB13 (short-circuiting 1-2 pin or all open), then turn on power of DAU again. LED
CD48 is lit in red, but it is not a problem.
5) After setup has been completed, reboot DAU. Then, check that LED CD48 is lit in green.
52
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Setting procedure is same as LAN connection equipment. Refer to "4.5.3 LAN Connection Setup".
Input each serial CH SFI set in "4.5.4.1 DAU Initial Setup" in Source SFI. Standard setting is listed in
the following table.
53
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
"Gyro Interface" can only select as Sensor Type. After setting, contents of [Recording Data] tab are
automatically set.
The other setting procedure is same as the case of LAN connection equipment. See "4.5.3 LAN
Connection Setup".
Input Gyro I/F SFI set in "4.5.4.1 DAU Initial Setup" in Source SFI. Standard setting is listed in the
following table.
54
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Remarks Gyro I/F icon of OPU is displayed only when Gyro I/F connection of DAU is enabled.
2) Initial heading setup screen opens. Using the keypad, set the indicated value of gyro compass to
Gyro setting column.
3) After the vessel was turning round, check that the value of Monitor column is approximately
equal to the indicated value of gyro compass. If significantly different, carry out 2) again.
If alert is not released in spite of set initial value of the heading, check whether Receive
Remarks
Group Settings of "4.5.4.1 DAU Initial Setup" has been correctly set.
55
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
"DAU" can only select as Sensor Type. After setting, contents of [Recording Data] tab are
automatically set.
1) Equipment
Input equipment name.
2) Model
Input "NCT-84".
3) Manufacturer
Input "JRC".
4) Serial No.
Shows DAU serial No. set in "4.4.3 Unit".
5) Version
Input software version. If it is unknown, input "Unknown".
56
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
6) Comment
Input comment. If there is nothing special, input "None".
7) IP Address
Input DAU IP address set in "4.5.4.1 DAU Initial Setup". Standard setting is listed in the following
table.
Clink [Operation Setting] button after inputting, then DAU installation setting screen displays.
8) Source SFI
Input DAU SFI set in "4.5.4.1 DAU Initial Setup". Standard setting is listed in the following table.
9) Destination SFI
In case of DAU, it does not need to set. Turn OFF the check.
57
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
When collect remote maintenance information via MFD SLC, set the equipment as LAN
(IEC61162-450) connected equipment. Refer to "4.5.5.2 LAN(IEC61162-450)
Remarks
Connection Setup" for the setting procedure. In addition, refer to "Annex 2 IP Address /
SFI of Remote Maintenance Equipment" to confirm SFI of SLC.
Equipment that sensor data and maintenance information is input to different CH (e.g. JHS-182)
・Sensor data input CH ... Appropriate sensor type
・Maintenance information input ... "Remote Maintenance"
58
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) If it is necessary to change baud rate, open [Serial Communication] tab, then change setting
depending on the equipment.
5) Open [Recording Data] tab, then check Remote Maintenance at the bottom.
Remote Maintenance
59
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
60
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Open [Sensor Identification] tab, then input target equipment's SFI into Source SFI field. Refer to
"4.5.3.3 Sensor Identification Tab" to input the other items.
Source SFI
5) Open [Recording Data] tab, then check Remote Maintenance at the bottom.
Remote Maintenance
61
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Input target equipment's IP address into IP Address field. Refer to "4.5.3.3 Sensor Identification
Tab" to input the other items.
IP Address
62
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
63
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Use
・Connect : ☑
・Disconnect : □
2) Equipment
Displays Remote Maintenance enabled equipment.
3) SFI/IP Address
Displays SFI (in case of IEC61162-450) or IP address (in case of RMS-LAN) of LAN connected
equipment.
4) Watch
Select valid or invalid of max interval watch for reception. If invalid is set, receive error doesn't
occur even if doesn't receive sentence for max interval time. Valid is set as default.
・Max interval watch valid : ☑
・Max interval watch invalid : □
5) Interval
Set max interval time for reception. If sentence doesn't receive for max interval time, receive error
occurs. 120 seconds is set as default.
6) Diagnosis lamp
Displays diagnosis result of total alarm from connected equipment.
・● (green) : OK
・● (red) : NG
・● (gray) : In check
7) Entry lamp
Displays result which is not inputted of equipment information.
・● (green) : Entry OK
・● (yellow) : Entry incomplete
If signal is not received within max interval time, Diagnosis lamp becomes red. But it
Remarks
does not appear as alert on OPU.
64
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
65
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
66
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Function INS
VDR ① Recording sensor data From
INS component equipment
67
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) LAN No.
Select the CH to connect INS.
2) Sensor Type
Select the Sensor Type to be used for INS connection. (INS-CCRS, INS-CAM/BAM, etc.)
3) Use
・Connect : ☑
・Disconnect : □
68
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
69
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
In case there is the Main equipment and the Backup equipment, the Backup equipment may output
a sentence only when the Main equipment cannot communicate.In this case, since the Backup
equipment does not output a sentence in the normal state, the following installation setting should
be done.
Example: Installation setting for integrating LAN No.1/2 connected equipments to LAN No.3
・Set up an equipment to be CCRS(Main) for LAN No. 1
・Set up an equipment to be CCRS(Backup) for LAN No. 2
・Set LAN No. 3 as a CH to duplicate and integrate sentences of LAN No.1/2
By doing this setting, if a sentence is input from either CCRS(Main) or CCRS(Backup), it will be in
normal state.
LAN No.1
CCRS(Main)
LAN No.2
CCRS(Backup)
LAN No.3
70
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Register No. 1 MFD and No. 3 MFD operating as CCRS in Sensor Equipments of INS-CCRS.
VDR
SFI:VR0001
JRC-LAN Hub
71
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Registered No. 3 MFD and No. 4 MFD with CAM function in Sensor Equipments of INS-CAM/BAM.
VDR
SFI:VR0001
JRC-LAN Hub
72
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
No. 1~5 MFD constituting INS are registered in Sensor Equipments of Multi Function Display.
VDR
SFI:VR0001
MFD->VDR ...HTC
JRC-LAN Hub
If set as above, even if non-INS, it operates to record sentence output by one of the
Remarks
multiple MFD.
73
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.6. IMAGE
Select order of Home screen, [Installation] tab, and [3. IMAGE].
74
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
75
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Display No.
Select display No.
2) Display Type
Refer to the table below, select depending on equipment and condition.
Connection I/F Equipment Condition Display Type
Via RGB Radar Operating state can acquire Select Radar
FGU(NWP-69) JMA-9100 from Serial/LAN. * Operates by
series * Operating state can acquire acquiring the
from RMS connection port. operation band and
Thus, RMS installed vessel transmission/standby
fall into this category. state from
Serial/LAN.
Operating state cannot Select X-band or
acquire from any connection. S-band
ECDIS - Select ECDIS
JAN-901B/701B
3rd party - Select X-band, S-band
equipment or ECDIS
LAN Radar * In case of IEC61162-450, Select Multi Function
IEC61162-450 ECDIS Display Type is transmitted
with the communication
data.
3) Display ID
According to the following table, it's assigned automatically.
Display Type Display ID
Radar, X-band, S-band R1, R2, ...
ECDIS E1, E2, ...
Multi Function Display D1, D2, ...
4) Use
・Connect : ☑
・Disconnect : □
76
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Model
Input model of the equipment.
2) Manufacturer
Input manufacturer name.
3) Serial No.
Input serial number. If it is uncertain, input "Unknown".
4) Version
Input software version. If it is unknown, input "Unknown".
5) Location
Input installation place of display equipment. "Wheelhouse" is set as default.
6) Comment
Input comment. If there is nothing special, input "None".
77
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
・LAN/FGU Port
Select connection method with display equipment(Radar/ECDIS/MFD).
RADAR JCY-1900
ECDIS VDR
LAN
78
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) Multicast IP Address
Input IP address for multicasting image data.
3) UDP Port No.
Input port number for multicasting image data.
4) Advanced
・□: Each Advanced setting items are set automatically.
・☑: Each Advanced setting items can be accepted a change.
Advanced
LAN
LAN
Display Information
(LAN or Serial)
- X-band/S-band Chart Information
- STBY ON/OFF
Image Data
Image Data
RGB RGB
79
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
FGU
1) FGU IP Address
Input IP address of connecting FGU.
2) Display Information Port (When Display Type is Radar, X-band or S-band)
When acquiring the operating state (X/S-band, STBY ON/OFF) by PJRC sentence from Radar
JMA-9100 series via serial or LAN, select connection port. VDR controls image recording operation
in accordance with the acquired operating state.
If Radar is connected via LAN for remote maintenance, operating state is output with remote
maintenance information. Thus, select LAN port that connected with Radar.
If acquire the operating state from serial, select serial port that connected with Radar.
3) Chart Information (When Display Type is ECDIS)
Check if receive chart information from ECDIS JAN-901B/701B via LAN.
4) SFI (When Chart Information is enabled)
Input SFI of ECDIS.
5) Multicast IP Address (When Chart Information is enabled)
Input destination multicast IP address that ECDIS output chart information.
6) UDP Port No. (When Chart Information is enabled)
Input destination port number that ECDIS output chart information.
80
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Remarks Recording tab is common setup for LAN connection and FGU connection.
1) Rec. Mode
・Select: Recording by switching same category image
2) Watch
Select valid or invalid of max interval watch for reception. If invalid is set, receive error doesn't
occur even if doesn't receive image for max interval time. Valid is set as default.
・Max interval watch valid : ☑
・Max interval watch invalid : □
3) Interval
Set max interval time for reception. If image data doesn't receive for max interval time, receive
error occurs. 60 seconds is set as default.
4) Recording
・VDR: Record valid / invalid to VDR is set. It is set as valid automatically, cannot be changed.
- Record valid : ☑
- Record invalid : □
・Opt.: This function is not available now.
・Fwd.: This function is not available now.
81
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Latest recorded display image and chart information (if acquired) is displayed by clicking [Get] button.
If there is no problem with displayed content, select [Good] on Check. Otherwise select [Fail] on
check, and input the detail information in Comment.
Input contents of this item is output in the report file. Refer to "4.9 REPORT" for more information.
82
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
LAN
LAN
IEC61162-450 IEC61162-450
*Chart Info *Chart Info
PJRC PJRC PJRC PJRC
*STBY ON/FF *STBY ON/FF
*RMS Data *1 *RMS Data *1
*RMS Data *1 *RMS Data *1 JRC LAN
RADAR 1/2 RADAR 1 RADAR 2 ECDIS 1/2 ECDIS 1 ECDIS 2
Image Data JMA-9100 JMA-9100 Image Data JAN-901B JAN-901B
JCY-1900
RGB RGB RGB RGB
VDR
83
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
LAN
LAN
JRC-LAN(Main)
JRC-LAN(Main)
84
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
・Network setting
Select order of Home screen, [Installation] tab, [1. SYSTEM] and [Network] tab.
b)
a)
a) L2 Switch Setting
Setting Value Description
JRCx JRC-LAN(Sub) Set JRC-LAN(Sub) connection port
Normally, it is connected to JRC4(J516).
b) IP Setting
Setting Value Description
JRC-LAN(Main) IP Address : 172.16.60.3
Subnet Mask : 255.255.0.0
Multicast Rx : ☑
JRC-LAN(Sub) IP Address : 172.17.60.3
Subnet Mask : 255.255.0.0
Multicast Rx : ☑
85
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
・Operation check
Make sure that image data can record from both JRC-LAN(Main) and JRC-LAN(Sub) by checking
collecting network display in list screen.
b) Make sure that collecting network display is changed as the following table in accordance with
JRC-LAN connection state.
JRC-LAN(Main)
JRC-LAN connection state
Connected Not connected
Connected JRC-LAN(Main) JRC-LAN(Sub)
JRC-LAN(Sub)
Not connected JRC-LAN(Main) ---
LAN
LAN
JRC LAN
RADAR 1/2 RADAR 1 RADAR 2 ECDIS 1/2 ECDIS 1 ECDIS 2
Image Data Image Data
JCY-1900
RGB RGB RGB RGB
VDR
86
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
LAN
LAN
RADAR JCY-1900
ECDIS VDR
87
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Network setting
3rd party Radar/ECDIS is connected to JRC-LAN(Ex1) network.
b)
a)
a) L2 Switch Setting
Setting Value Description
JRCx JRC-LAN(Ex1) Set 3rd party Radar/ECDIS connection port
Normally, it is connected to
JRC3(J515)/JRC4(J516).
b) IP Setting
Setting Value Description
JRC-LAN(Ex1) IP Address : x.x.60.3 Set according to IP address of 3rd party
Subnet Mask : 255.255.0.0 Radar/ECDIS.
Multicast Rx : ☑ * If network address of 3rd party Radar/ECDIS is
same as JRC-LAN(Main), separate each
network by changing subnet mask as follows:
JRC-LAN(Main) : 172.16.60.3/255.255.255.0
JRC-LAN(Ex1) : 172.16.x.3/255.255.255.0
88
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) Setting example 1: 3rd party Radar/ECDIS does not belong to JRC-LAN(Main) network
・3rd party Radar/ECDIS specification
Check item 3rd party Radar/ECDIS specification
IP Address 172.24.0.1/16
SFI EI0001
Image transmission: Multicast IP Address 239.192.0.26
Image transmission: Port No. 60026
Image format PNG
・Setting
Setting Value
L2 Switch Setting JRC4(516) JRC-LAN(Ex1)
IP Setting JRC-LAN(Ex1) IP Address : 172.24.60.3
Subnet Mask : 255.255.0.0
Multicast Rx : ☑
Image Display Type Multi Function
LAN/FGU Port LAN
SFI EI0001
Multicast IP Address 239.192.0.26
UDP Port No. 60026
・Setting
Setting Value
L2 Switch Setting JRC4(516) JRC-LAN(Ex1)
IP Setting JRC-LAN(Main) IP Address : 172.16.60.3
Subnet Mask : 255.255.255.0
Multicast Rx : ☑
JRC-LAN(Ex1) IP Address : 172.16.0.3
Subnet Mask : 255.255.255.0
Multicast Rx : ☑
89
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.7. AUDIO
Select order of Home screen, [Installation] tab and [4. AUDIO].
List shows connection status. Set the connection in the detail setup screen.
・Connect : ☑
・Disconnect : □
Connection
90
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Indoor
Input indoor microphone model name. Set "NVT-181" as default.
2) Waterproof
Input waterproof microphone model name. Set "NVT-182" as default.
91
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Use
Select microphone connection status.
2) Location
Input installation place of microphone.
3) Type
Select Indoor or Waterproof with pull down menu.
4) Serial No.
There is lot number on the microphone, not serial number. Input lot number.
5) Comment
Input comment. If there is nothing special, input "None".
92
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Select target microphone to check with radio button. When clicking [Start Recording], displayed as
follows. Audio is recorded for max 1 minute until clicking [Stop Recording].
When [Stop Recording] is click to stop, playback panel is displayed. And then recorded audio is
played back automatically.
If there is no problem with playback content, select [Good] on Check. Otherwise select [Fail] on
check, and input the detail information in Comment.
Input contents of this item is output in the report file. Refer to "4.9 REPORT" for more information.
93
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
List shows connection status. Set the connection in the detail setup screen.
・Connect : ☑
・Disconnect : □
Connection
94
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Use
Select VHF connection status.
2) Location
Select installation place of VHF.
3) Model
Input model of the equipment.
4) Manufacturer
Input manufacturer name.
95
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
5) Serial No.
Input serial number. If it is uncertain, input "Unknown".
6) Comment
Input comment. If there is nothing special, input "None".
Select target microphone to check with radio button. When clicking [Start Recording], displayed as
follows. Audio is recorded for max 1 minute until clicking [Stop Recording].
When [Stop Recording] is click to stop, playback panel is displayed. And then recorded audio is
played back automatically.
If there is no problem with playback content, select [Good] on Check. Otherwise select [Fail] on
check, and input the detail information in Comment.
Input contents of this item is output in the report file. Refer to "4.9 REPORT" for more information.
96
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Remarks In case of S-VDR, diagnosis of the capsule that is not installed is not displayed.
1) Model
Select model name of fixed protective capsule.
2) Serial No.
Serial No. is displayed. It cannot be changed.
3) Comment
Input comment. If there is nothing special, input "None".
97
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Model
Select model name of float-free capsule.
2) Serial No.
Serial No. is displayed. It cannot be changed.
3) Comment
Input comment. If there is nothing special, input "None".
1) Model
Select model name of internal storage.
2) Serial No.
Serial No. is displayed. It cannot be changed.
3) Comment
Input comment. If there is nothing special, input "None".
98
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4.9. REPORT
After installation, setup data and diagnosis result are output as report files. Output report files are saved
into ship list of MS. Please be sure to send the report files.
1) Installation Section
Setup contents of the following items are checked by selecting pull down menu.
・"4.4 SYSTEM"
・"4.5 SENSOR"
・"4.6 IMAGE"
・"4.7 AUDIO"
・"4.8 RECORDING MEDIUM"
2) Filter
Only uncompleted item which is focused on the following filter from installation setup items can be
displayed.
・All
No filtering. All installation setup are displayed.
・No Entry lamp
Entry displays only items of NG (yellow lamp).
・NG lamp of Diagnosis
Diagnosis displays only items of NG (red lamp).
・NG result of check
Result of check displays only items of judged NG by serviceman.
99
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
NG lamp of NG result of
System × × × ×
Sensor ○ ○ ○ ○
Image ○ ○ ○ ○
Audio ○ ○ ○ ○
Recording Medium ○ × ○ ×
100
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) List display
・Diagnosis
Check that diagnosis result is OK by diagnosis lamp.
- ● (green) : OK
- ● (red) : NG
・Entry
Check that there is not blank input by Entry lamp.
- ● (green) : OK
- ● (yellow) : There is blank input.
・Comment
Input comment. If there is nothing special, input "None".
4) Action
・[Download]
Collect setup data and diagnosis result after installation, then download report file
(MBXXXXX_VDR_Report.tgz). Add ship's name or ship's number to front of file name for
identification.
e.g.) Ship's name... JRC MARU
File name ... JRC_MARU_MBXXXXX_VDR_Report.tgz
・[Upload]
Read saved report file. All entries before the upload will be overwritten.
・[Clear]
Clear input contents of Comment and Check.
After completing installation, please make sure to save report file into Ship Register List
Remarks
on MS Web.
5) Report file
Composition of report file is as follows. In addition to report data, sensor, image and audio data that
download from VDR internal storage is saved. To check these data, use playback software.
Report data
101
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(Blank page)
102
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
103
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Fwd. No.
Select output setting No.
2) Use
・Output enable : ☑
・Output disable : □
104
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Dest Name
Input destination name.
2) Comment
Input comment. If there is nothing special, input "None".
1) IP Address
Input IP address of destination. The following IP address can be selected as standard setting.
No. Category IP address
1 Multicast 239.0.112.1
2 Unicast 192.168.0.251
3) Gateway IP Address
If output destination does not belong to VDR network, input gateway IP address.
In case of multicast, the setup is not necessary since realtime data is out in the same network.
105
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Output I/F
Select output network with pull down menu.
No. Selection Output network
1 VDR-LAN VDR Network
2 JRC-LAN(Main) Main LAN of JRC network
3 JRC-LAN(Sub) Sub LAN of JRC network
4 JRC-LAN(Ex1) Reserve
5 JRC-LAN(Ex2) Reserve
6 USER-LAN User LAN
106
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
5.2.1. Wiring
(1) Open door VDR/S-VDR main unit with key, connect LAN cable to EXT port.
Key
EXT port
107
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Assigned IP address
Home screen
Remove "✓"
108
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
5.2.4. Setup
(1) Click in order of [Playback] and [SETUP].
109
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(3) Select one from 4 modes in the "For" of Setup Folder block.
Mode
Mode1: Live
Mode2: Playback
Mode3: Live / Playback
Mode4: Live / Playback / Record
Playback Folder
Record Folder
Record Period
Overwrite
(5) Click [Set], and close the Setup software with clicking [Close].
110
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[PLAYBACK]
111
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(Blank page)
112
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
113
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
New
Old
State
114
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
6.3. SYSTEM
System log file can be downloaded. If there is a request, click [Download] button without changing all of
the checkbox.
115
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
6.4. POWER
Log file about power supply unit can be downloaded. If there is a request, click [Download] button
without changing all of the checkbox.
116
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
6.6. NETWORK
Packet capture data can be downloaded.
1) VLAN Group
Select network to capture packets.
2) Period
Set period of capturing.
3) Max Packets
Set number of packets to capture.
4) Use Promiscuous Mode
When checked ON, all packets flowing in the network are captured.
Packet capturing will stops when elapsed time reaches Period or number of captured
Remarks
packet reaches Max Packets.
117
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(Blank page)
118
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
119
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
120
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Diagnosis lamp
Shows reception status of maintenance data.
・● (green) : Receive OK
・● (red) : Receive NG
・● (yellow) : In check
2) Alert lamp
Shows Operation status of target equipment.
・● (green) : Normal
・● (red) : Abnormal
・● (yellow) : In check
Conversion definition file (...csv) appears in Data Form for each equipment. Select appropriate file,
then click [View] button.
121
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
1) Diagnosis lamp
Reception status of maintenance data is indicated.
・● (green) : Receive OK
・● (red) : Receive NG
・● (yellow) : In check
2) Alert lamp
Operation status of target equipments is indicated.
・● (green) : Normal
・● (red) : Abnormal
・● (yellow) : In check
3) Selection of maintenance data
・Latest : Latest received sentence
・Log(Diff) : Received sentence at different point
・Log(All) : All received sentence
122
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
123
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
124
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
125
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Update]
126
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Update]
127
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(Blank page)
128
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Yes] button
129
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(3) The Install Shield Wizard for Maintenance software starts, and click [Next] button.
130
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(4) The confirmation screen where the installation folder and user information are shown is
indicated, and click [Install] button.
131
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
When displaying the following screen, Visual C++ Runtime Library has already been
installed, it is not error.
Click [Close] button, and close the screen.
Remarks
After that, though the following screen is displayed, click [OK] button, and close the
screen.
132
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(9) Since Maintenance software partially uses network communication, disable the firewall
function on your PC in accordance with the following procedure.
133
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Windows Firewall
・Select "Turn off Windows Firewall (not recommended)", and click [OK] button.
134
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(10) If the operating system (OS) on your PC is not Japanese or English version, Playback
software might not display correctly.
Please set language to "English (United States)" or "English (United Kingdom)" as follows.
Administrative
135
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(11) For OS later than Windows 7, since Maintenance software has to start by the administrator
user continually, set as follows.
・ Select "Properties".
Properties
・ Input "✔" mark in "Run this program as an administrator" under "Privilege Level", and click
[OK] button.
Compatibility tab
Privilege Level
136
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
After installation also, always login as administrator user and use Maintenance software.
In addition, since the confirmation screen is displayed at starting Maintenance software,
click [Yes] and start the software.
Remarks
Yes
●For Windows 10
・ Right-click the "JCY-1900 VDR Maintenance" icon on desktop.
・ Select "Properties".
Properties
137
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
・ Input "✔" mark in "Run this program as an administrator" under "Privilege Level", and click
[OK] button.
Compatibility tab
・Click "Programs".
Uninstall a program
138
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
JCY-1900
VDR Maintenance
[Yes] buttton
・Since some files remain in the installation folder after completing the uninstallation, open My
Computer and delete the folder.
Installation folder:
32bit PC C:\Program Files\JRC\JCY1900\Maintenance
64bit PC C:\Program Files (x86)\JRC\JCY1900\Maintenance
139
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[PLAYBACK] button
140
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Dry contact data, such as alarm, door (open or close) and others should be changed into NMEA
sentences.
The screen for creating conversion table file will appear.
Remarks The setup software for dry contact unit is the same as JCY-1800/1850.
141
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
● Connection CH
Select a channel which is connected to the dry contact signal.
The condition of the equipment shown by OPEN/CLOSE of a dry contact signal is set up.
1) Alarm
Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is in
normal state.
2) Door
Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.
142
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
143
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
The tree structure displayed on the left screen shows the dry contact inputs that can be
registered.
Sentence data can be set up by double-clicking each item.
Selected
sentence
Double-
Click
Be careful not to double select an identification number otherwise the same sentence data
will be created
144
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) Comment
Each sentence can be followed by a comment.
Add a comment to each sentence by which a service engineer recognizes what the signal is.
1) Selecting a sentence
Double click the sentence displayed on the list.
The CH number for deletion is displayed.
2) Deleting a sentence
Click the [Delete] button.
3) Editing a sentence
Set up a new sentence data after deletion.
145
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
146
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
147
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
6) Enable setting
Setup procedure is the same as "Engine telegraph position".
7) Disable setting
Select "Other".
148
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
149
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
150
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
LAN
NWP-69 No.3 FGU
192.168.110.151
DATA
↓
192.168.60.7 or 172.16.60.7
LAN
Maintenance PC
151
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) At first, connect LAN cable to RSV port from JRC network.(Figure 10.1 ①)
4) Turn on power of No.1 FGU. (If No.2 or 3 FGU is connected, turn off power of them)
FGU No.1, 2, and 3 are set all the same IP address (192.169.110.151).
Remarks If several FGU power are turned on before changing IP address, setup cannot be
changed as IP addresses compete.
5) Click "JCY-1900 VDR Maintenance" icon on desktop, and start Maintenance software.
152
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
"FGU1"
"192.168.110.3"
If skip 9), setting might fail. Because command from Maintenance software overlaps with
Remarks
command from MCB.
153
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
10) Select "192.168.110.151" in FGU IP Address, and then click [IP Address Change] button.
"192.168.110.151"
11) Select "192.168.60.5" or "172.16.60.5" in New IP Address according to JRC LAN network.
Click [Change] button.
"192.168.60.5" or "172.16.60.5"
[Change] button
12) The following screen is displayed. Click [OK] button. Then FGU reboots.
To complete reboot after displaying "Reset.txt write OK", it takes time for several
Remarks
seconds.
13) Return connection of LAN cable from RSV port to JRC LAN.
(Figure10.1 ②)
154
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
14) Select "192.168.60.5" or "172.16.60.5" in FGU, and then click [FGU Setting] button.
"192.168.60.5" or "172.16.60.5"
15) Capture setting/tuning screen is displayed. Refer to "10.4.3 Capture Setting / Tuning", set capture
setup for No.1 FGU.
16) After completing of capture setup, click [FGU Control Stop] button (Blue). FGU access for image
capture by MCB is restarted.
17) If No.2 FGU or more are installed, please set the FGU according to the procedures from 1) to 15).
Since an IP address does not compete in FGU where setting was completed, it is not necessary
to switch off the FGU.
155
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Factory setting of the jumper pins and DIP-SW (S2) are shown below. Do not change the
following setting.
7
6
S2
5
4
3
2
1
3-4 Short
5-6 Short
3-4 Short
5-6 Short
3-4 Short
5-6 Short
P5: 1-2 Short
156
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
For proper capture setting, check the Radar image specifications (VESA format only) first then verify
the following items.
Resolution: (e.g. 1280x1024)
Vertical synchronous signal frequency (Refresh rate): (e.g. 60 Hz)
Horizontal synchronous signal frequency: (e.g. 75 kHz)
Polarity of Vertical synchronous signal: (e.g. Positive or Negative)
Polarity of Horizontal synchronous signal: (e.g. Positive or Negative)
157
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
If clicking [FGU Setting] button without stopping FGU access to MCB with [FGU Control
Stop] button, the following dialog is displayed.
In such a case, setting might fail. Because command form Maintenance software
overlaps with command from MCB.
Remarks
158
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
c) "Changed to channel 1" message appears at the left bottom corner of the window.
10.4.3.3. Checking the captured Radar image specifications and Board model name
Check the captured Radar image specifications and Board model name by FGB following the
instructions.
159
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
For CKA-137A
Measured value
Sync Activity ch 1
Sync Activity ch 2
V sync polarity
H sync polarity
V sync frequency
H sync frequency
Total line number
Setup value
V sync polarity
H sync polarity
160
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
For CKA-137B
Sync Activity ch 1
Sync Activity ch 2
V sync polarity
H sync polarity
V sync frequency
H sync frequency:
Total line number
Setup value
V sync polarity
H sync polarity
Resolution (estimated value)
c) Check that the Radar image format measured by FGB is the same as that of the Rader
specifications.
Resolution (estimated value):
Vertical synchronous signal frequency (Refresh rate):
Horizontal synchronous signal frequency:
Vertical synchronous signal polarity:
Horizontal synchronous signal polarity:
If the "Sync Activity" column is inactive, most probably synchronous signal could not be detected
by the board. Verify the wiring, signal output and input channel.
161
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
When sent the different FGB's capture setting file, reply with "NG" from FGB.
Remarks
So, sent the collect capture setting file again.
162
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
163
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
From this point forward, tune the image in the following order.
1) Sync polarity tuning (The CKA-137B is unnecessary.)
Remarks 2) Horizontal position tuning
3) Vertical position tuning
4) Sampling Phase tuning
164
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Measured value
Setup value
165
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
g) Have a look on the [ADC status] menu, and check that the measured H sync polarity is the same
as that of the setup.
Regarding the V sync polarity, follow the same procedure using [V Sync polarity reverse] menu.
166
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
d) Click the horizontal edge of the image. Don't care the Y coordinates.
167
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
e) To practice horizontal position tuning at this point, click [Yes]. Or to retry the image shift,
click [No] and tweeze the horizontal edge of the image.
After successful horizontal position shift and image capture, the result message appears.
c) To have the image moved left, click the [Yes] button. To have the image moved right, click
[No]. To finish the tuning, click the [Cancel] button.
After successful horizontal position shift and image capture, the result message appears.
168
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
169
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
170
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
LAN
NWP-69 No.3 FGU
192.168.110.151
DATA
↓
192.168.60.7 or 172.16.60.7
LAN
Maintenance PC
171
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
5) Start browser (e.g. IE) with maintenance PC, access to "192.168.110.151" (No.1 FGU).
FGB home page is displayed.
172
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
7) Select in order of "File (F)" and "Save As". Input a certain name (e.g. serial number) and save. After
← (return) of browser.
saving, return to FGB home page by clicking ○ E
A
→
9) Edit the file.
Delete "IP.txt OK" of top line.
Correct the "IP=" key's value to "192.168.060.005".
(In case of new JRC network, "172.016.060.005")
Correct the "GW=" key's value to "192.168.060.003".
(In case of new JRC network, "172.016.060.003")
Overwrite the file.
173
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
← (Return) of browser.
13) Check that "IP.txt write OK" is displayed, and click ○ E
A
174
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
14) Click "Reset" menu of FGB home page, and check that "Reset.txt OK" is displayed. Then click ○
← A
E
(Return) of browser.
A
15) Turn on power of No.2 FGU (Keep power on of No.1, and turn off power of No.3 FGU)
16) Click ↻(Refresh) of browser, and access "192.168.110.151"(No.2 FGU).
17) Click "IP.txt" menu..
18) Select in order of "File (F)" and "Save As"
Save a name (e.g. serial number) which is different from 7). After saving, return to FGB home page by
A
← (return) of browser.
clicking ○ E
A
19) Open the saved file, and open the file with notepad.
20) Edit the file.
Delete "IP.txt OK" of top line.
Correct the "IP=" key's value to "192.168.060.006".
(In case of old JRC LAN, "172.016.060.006")
Correct the "GW=" key's value to "192.168.060.003".
(In case of old JRC LAN, "172.016.060.003")
Overwrite the file.
21) Click the "ip.txt upload" on FGB home page.
22) Click [Browse], and select the file saved 20).
23) Click [UPLOAD]
← (return) of browser.
24) Check that "IP.txt write OK" is displayed, and click ○A
E
A
← (return) of
25) Click "Reset" menu of FGB home page. Check that "Reset.txt OK" is displayed, and click○ A
E
A
browser.
26) If No.3 FGU is connected, correct IP address by the same procedure.
27) Return LAN cable from JRC LAN network to JRC_LANx port. (Figure10.2 ②)
28) Access to "192.168.60.5" (No.1 FGU), and check that FGB home page is displayed.
Also, access to No.2 FGU (192.168.60.6) and No.3 FGU (192.168.60.7), that FGB home page is
displayed.
175
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
A web browser is started and input the FGB IP address to the address space, and distinct the FGB
root menu.
For CKA-137A (Not indicate the model name and indicated version is 2.0.0 or 2.0.1)
For CKA-129 (Not indicate the model name and indicated version is 1.0.2.)
176
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Click the [Back] button of IE, and the display screen will go back to the root menu.
177
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
178
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
179
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Click [Select] button, open VDR event log file (evt file). Event logs in the event file are listed.
5) The listed contents can be put out with CSV format with clicking [Save] button.
6) The event log files can be downloaded by the following methods.
- Download from Maintenance web browser.
- Download record data with Playback software
- Download record data with copy function of OPU
About how to download event log file from Maintenance Web browser, refer to "6.2
Remarks
EVENT DOWNLOAD".
When downloading record data with playback software or copy function of OPU, the
Remarks
event files are downloaded into "event" folder.
180
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
181
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
4) Click in order of [File] and [Open]. And select folder where remote maintenance log files are
saved.
The remote maintenance log files can be downloaded from maintenance web.
About how to download remote maintenance log file on maintenance web, refer to "7.2
Remarks
RMS LOG DOWNLOAD".
182
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[APTDOWNLOAD] button
Download software for APT check the connection between recording medium (fixed /
float-free capsule and internal storage) and VDR at startup. If an error dialog is
Remarks displayed, check the followings:
- Maintenance PC is properly connected to VDR DATA port.
- Fixed / float-free capsule and internal storage is working properly.
183
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Get Period Get File Size / Num. of Files Recording medium selection
2) Click [Get Info.] button to acquire the recorded information from target recording medium.
Latest recorded time Oldest recorded time Recording period
184
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) After acquisition is completed, it's possible to save acquired contents by clicking [Save] button.
When acquiring the recorded information, it's unable to get number of files from fixed
Remarks
protective capsule.
Since the recording method of each recording medium is different, the value of "Size"
Remarks
column might be different even if recorded the same data.
When downloading record data while continuing record, recommend to download except
the latest one hour data.
When selecting the latest one hour data, the following dialog is displayed.
So please note the followings.
・Number of actual downloaded file is greater than number of downloaded file with the
“Get Info”.
・Timing of download completion of Sensor, Audio and Visual is not the same time.
Therefore regarding the latest one hour, end of data and time on downloaded data of
Sensor, Audio and Visual is not the same time.
Remarks
185
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
2) Click [Download] button, then a dialog to set the folder name of the download destination
displays. After setting, click [OK] button to start download.
186
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
3) After download is completed, downloaded capacity and number of files will be displayed in blue.
In case of float-free capsule and internal storage, number of files obtained by the
recorded information and number of downloaded files are displayed respectively. By
comparing them, it's possible to verify that the download was completed successfully.
Remarks
Num. of downloaded files Num. of files obtained by the recorded information
If each recording medium was working properly, downloaded capacity and number of
downloaded files at the same time will be equal value.
Remarks Equal capacity and equal number of files
187
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
188
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
189
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
190
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
191
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11.1.3.1. Protocol
It varies according to registry country whether ID of MMSI or serial is inserted in a transmission
message.Select either by Protocol menu.
192
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
193
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
194
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
195
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
e.g. Oct.2019
Batter expiry is normally 5 years in most countries. But some countries like Spain, Italy
Remarks
and Sweden require battery change every 4 years.
196
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11.1.4. Program
Program the EPIRB information according the following procedures.
Click the [Program] button.
Then progress bar screen is displayed.
197
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
198
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
When printing the information to labeler (e.g. Tepra), print them to 2 kinds of tape according to the
table.
・Label tape: (Transparent tape, Black font)
・Font: 14point、MSP Gothic
Print contents
No. Labelape Line No. Item Remark
1 9mm 1 VDR system
2 36mm 1 Serial no. Blank
2 HEX Code.UN
3 Vessel name
4 MMSI/Call Sign Print MMSI number
5 Country e.g.) If flag is Japan, print "Japan".
199
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11.1.5. Read
The programmed information can be checked by clicking
the [Read] button.
The procedure after clicking the [Read] button is same as
programming.
After reading from Tron 40VDR capsule, EPIRB information
is displayed.
Input information in the "11.1.3.5 Vessel information block"
is not displayed.
Check that the information except the "Vessel information"
is programmed correctly.
Note)
The contents of "11.1.3.5 Vessel information
block" are not displayed.
200
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
e.g.)Nov. 2016
201
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11.3.1. Start
Connect probe of EPIRB test (Tron Unidec) to USB port of
using PC.
Then, click the Unidec icon on the desktop to start the
EPIRB tester.
202
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
11.3.2. Test
EPIRB tester opens the left screen and searches
automatically COM port which is connecting probe.
When finding COM port, the port number is displayed.
Select "406.037MHz" in the Frequency.
Click the [Request Data] button.
Keep lever to right ("TEST") until making a flush of top light.
Status
After flushing, release the lever.
203
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
204
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Close] [Print]
205
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
The file is saved by one of PDF, Microsoft Office Document Writer or Microsoft XPS Document
Writer.
・PDF
・Microsoft Office Document
Writer
・Microsoft XPS Document
Writer
Save a file by one of above.
206
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Yes] button
207
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(2) The Install Shield Wizard for ID Programmer software starts, and click [Next] button.
208
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
209
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Device Manager
Unknown device
[Update Driver]
210
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(5) Click [Browse] button, and select folder where USB serial driver software is saved.
And then click [Next] button.
[Browse]
[Next]
(6) Windows Security screen is displayed. Click "Install this driver software anyway".
(8) Since install of USB serial driver software is completion, click [Close] button.
[Close]
211
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Yes] button
212
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
[Next]
[Browse]
[Next]
[Next]
213
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
(4) Click [Next] button with putting "✓" in "Create a desktop icon".
[Next]
[Install]
[Finish]
214
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
Connection Baud
Interface Rate Equipment Name Model Name
Serial 38400 AIS JHS-182
4800 GPS JLR-7900
4800 GPS Compass JLR-21/31
19200 Speed Log JLN-205/550
4800 Echo Sounder JFE-380/680
4800 BNWAS JCX-161
4800 Radar JMR-9100 series
4800 MF/HF JSS-2150/2250/2500
4800 VHF JHS-770S/780D
4800 NAVTEX NCR-333
4800 Weather FAX JAX-9B
4800 Satellite Log JLN-720
4800 Doppler Log JLN-740
LAN (RMS-LAN) - AIS JHS-183
- GPS JLR-7800
- Radar JMA-9100 series
- ECDIS JAN-901B/701B
- Conning Display JAN-901B/701B-CON
- Route Planning System JAN-1186
- Inmarsat-C JUE-87
- Inmarsat-FB JUE-251/501
- Inmarsat-GX JUE-60GX
- VDR JCY-1900
LAN (IEC61162-450) - Radar JMR-9200 series
- ECDIS JAN-9201/7201
- Conning Display JAN-9202
- Route Planning System JAN-5203
- Satellite Log JLN-720
- Doppler Log JLN-740
(In December 2016)
215
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
216
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
217
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
218
JCY-1900/1950 VDR/S-VDR Installation Manual (Software Part)
219
JCY-1900
1900/1950
1950
VOYAGE DATA RECORDER (VDR)
SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)
INSTALLATION
MANUAL
(Software Part)