Exterior wall Exterior wall


created on 24.10.2022

Thermal protection Moisture proofing Heat protection


No condensate Temperature amplitude damping: 31
U = 0,28 W/(m²K) phase shift: 10,2 h
Thermal capacity inside: 108 kJ/m²K
GEG 2020 Bestand*: U<0,24 W/(m²K)

excellent insufficient excellent insufficient excellent insufficient

outside
60 9
5 8
50 7
3 6
290

110
www.ubakus.de
5

27 4

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
3
10
12,5 1 2
inside

60 600

1 Rigips 1-Mann-Feuchtraumplatte "Die Grüne" (12,5 mm) 6 HASIT DIEPLAST 865 MINERAL Klebe- und Armierungsmörtel (3 mm)
2 Stationary air (10 mm) 7 weber.therm EPS 040 Fassade (50 mm)
3 Rigips 1-Mann-Feuchtraumplatte "Die Grüne" (12,5 mm) 8 HASIT DIEPLAST 865 MINERAL Klebe- und Armierungsmörtel (5 mm)
4 Stationary air (27 mm) 9 Knauf Insulation Fassaden-Dämmplatte FPL-040 (60 mm)
5 solid bricks, 1000 kg/m3, 1952 (110 mm)

Inside air : 23,0°C / 50% Thickness: 29,0 cm


Outside air: -20,0°C / 65% sd-value: 4,3 m Weight: 140 kg/m²
Surface temperature.: 19,9°C / -19,5°C Heat capacity: 139 kJ/m²K

*Vergleich mit dem Höchstwert gemäß GEG 2020 für erstmaligen Einbau, Ersatz oder Erneuerung von Außenwänden (Anlage 7, Zeile 1a,1b). Page 1
All statements without guarantee

Exterior wall, U=0,28 W/(m²K)

Temperature profile
Temperature profile
Temperature
20
1 Dew point
15 2
10 3 4 5 6 7 8 9
Temperature [°C]

5
0 outside
-5
-10
-15
-20 www.ubakus.de
-25
0 50 100 150
200 250 300 inside
Inside 0°C [mm]
www.ubakus.de

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
Outside 60 600

1 Rigips 1-Mann-Feuchtraumplatte "... 4 Stationary air (27 mm) 7 weber.therm EPS 040 Fassade (50 mm)
2 Stationary air (10 mm) 5 solid bricks, 1000 kg/m3, 1952 (110 mm)
8 HASIT DIEPLAST 865 MINERAL Kl...
3 Rigips 1-Mann-Feuchtraumplatte "... 6 HASIT DIEPLAST 865 MINERAL Kl... 9 Knauf Insulation Fassaden-Dämmp...

Left:Temperature and dew-point temperature at the place marked in the right figure. The dew-point indicates the
temperature, at which water vapour condensates. As long as the temperature of the component is everywhere above the dew
point, no condensation occurs. If the curves have contact, condensation occurs at the corresponding position.
Right: The component, drawn to scale.

Layers (from inside to outside)


# Material λ R Temperatur [°C] Weight
[W/mK] [m²K/W] min max [kg/m²]
Thermal contact resistance* 0,130 19,9 23,0
1 1,25 cm Rigips 1-Mann-Feuchtraumplatte "Die Grüne" 0,250 0,050 19,2 20,2 8,5
2 1 cm Stationary air (unventilated) 0,067 0,150 17,2 19,6 0,0
3 1,25 cm Rigips 1-Mann-Feuchtraumplatte "Die Grüne" 0,250 0,050 16,2 17,9 8,5
4 2,7 cm Stationary air (unventilated) 0,150 0,180 15,2 17,3 0,0
2,7 cm Steel (0,091%) 50,000 0,001 15,8 16,2 0,2
2,7 cm Steel (0,091%) 50,000 0,001 15,8 16,2 0,2
0,06 cm Steel (Width: 0,6 cm) 50,000 0,000 16,2 16,3 0,0
0,06 cm Steel (Width: 0,6 cm) 50,000 0,000 16,2 16,3 0,0
0,06 cm Steel (Width: 6 cm) 50,000 0,000 15,7 15,8 0,4
5 11 cm solid bricks, 1000 kg/m3, 1952 (MZ, HLz) 0,460 0,239 12,5 15,8 110,0
6 0,3 cm HASIT DIEPLAST 865 MINERAL Klebe- und 0,610 0,005 12,4 12,7 3,5
Armierungsmörtel
7 5 cm weber.therm EPS 040 Fassade 0,040 1,250 -2,0 12,6 0,8
8 0,5 cm HASIT DIEPLAST 865 MINERAL Klebe- und 0,610 0,008 -2,1 -2,0 5,8
Armierungsmörtel
9 6 cm Knauf Insulation Fassaden-Dämmplatte 0,040 1,500 -19,5 -2,1 2,4
FPL-040
Thermal contact resistance* 0,040 -20,0 -19,5
29 cm Whole component 3,582 140,3
*Thermal contact resistances according to DIN 6946 for the U-value calculation. Rsi=0,25 and Rse=0,04 according to DIN
4108-3 were used for moisture proofing and temperature profile.

Surface temperature inside (min / average / max): 19,9°C 20,1°C 20,2°C


Surface temperature outside (min / average / max): -19,5°C -19,5°C -19,5°C

Page 2
All statements without guarantee

Exterior wall, U=0,28 W/(m²K)

Moisture proofing
For the calculation of the amount of condensation water, the component was exposed to the following constant climate for
90 days: inside: 23°C und 50% Humidity; outside: -20°C und 65% Humidity (Climate according to user input).
This component is free of condensate under the given climate conditions.

# Material sd-value Condensate Weight


[m] [kg/m²] [Gew.-%] [kg/m²]
1 1,25 cm Rigips 1-Mann-Feuchtraumplatte "Die Grüne" 0,05 - 8,5
2 1 cm Stationary air (unventilated) 0,01 - 0,0
3 1,25 cm Rigips 1-Mann-Feuchtraumplatte "Die Grüne" 0,05 - 8,5
4 2,7 cm Stationary air (unventilated) 0,01 - 0,0
2,7 cm Steel (0,091%) 33,33 - 0,2
2,7 cm Steel (0,091%) 33,33 - 0,2
0,06 cm Steel (Width: 0,6 cm) 1500 - 0,0
0,06 cm Steel (Width: 0,6 cm) 1500 - 0,0
0,06 cm Steel (Width: 6 cm) 1500 - 0,4
5 11 cm solid bricks, 1000 kg/m3, 1952 (MZ, HLz) 1,10 - 110,0
6 0,3 cm HASIT DIEPLAST 865 MINERAL Klebe- und 0,06 - 3,5

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
Armierungsmörtel
7 5 cm weber.therm EPS 040 Fassade 2,50 - 0,8
8 0,5 cm HASIT DIEPLAST 865 MINERAL Klebe- und 0,10 - 5,8
Armierungsmörtel
9 6 cm Knauf Insulation Fassaden-Dämmplatte 0,06 - 2,4
FPL-040
29 cm Whole component 4,33 140,3

Humidity
The temperature of the inside surface is 19,9 °C leading to a relative humidity on the surface of 60%.Mould formation is not
expected under these conditions.
The following figure shows the relative humidity inside the component.

100 Relative humidity (%)


1 saturation point
90
2
80
Relative humidity (%)

3 4 5 6 7 8 9
70
60
outside
50
40
30
20
10
www.ubakus.de
0
0 50 100 150 200 250 300 inside
Inside 0°C [mm]
www.ubakus.de Outside 60 600

1 Rigips 1-Mann-Feuchtraumplatte "... 4 Stationary air (27 mm) 7 weber.therm EPS 040 Fassade (50 mm)
2 Stationary air (10 mm) 5 solid bricks, 1000 kg/m3, 1952 (110 mm)
8 HASIT DIEPLAST 865 MINERAL Kl...
3 Rigips 1-Mann-Feuchtraumplatte "... 6 HASIT DIEPLAST 865 MINERAL Kl... 9 Knauf Insulation Fassaden-Dämmp...

Notes: Calculation using the Ubakus 2D-FE method. Convection and the capillarity of the building materials
were not considered. The drying time may take longer under unfavorable conditions (shading, damp / cool
summers) than calculated here.

Page 3
All statements without guarantee

Exterior wall, U=0,28 W/(m²K)

Heat protection
The following results are properties of the tested component alone and do not make any statement about the heat protection
of the entire room:

Temperature profile
This document has been generated by the U-value calculator on www.ubakus.de. If you are harmed by the free use of these contents, the service provider is only liable in case of

36 Temperature at 3pm, 11am and 7am


34 1 Temperature at 7pm, 11pm and 3am
intent and gross negligence on the part of the service provider. For further information, please refer to the terms and conditions at https://www.ubakus.de/agb

32 2
3 1 Rigips 1-Mann-Feuchtraumplatte "Die Grüne" (12,5 mm)
30
Temperature [°C]

4 5 6
28 2 Stationary air (10 mm)
7 8 9
26 3 Rigips 1-Mann-Feuchtraumplatte "Die Grüne" (12,5 mm)
24 4 Stationary air (27 mm)
5 solid bricks, 1000 kg/m3, 1952 (110 mm)
22
6 HASIT DIEPLAST 865 MINERAL Klebe- und Armierungsmörtel (3 mm)
20
7 weber.therm EPS 040 Fassade (50 mm)
18
8 HASIT DIEPLAST 865 MINERAL Klebe- und Armierungsmörtel (5 mm)

Commercial use only with Plus-, PDF- or Profi-Option (from 2.99 € / month plus VAT).
16
9 Knauf Insulation Fassaden-Dämmplatte FPL-040 (60 mm)
14
0 50 100 150 200 250 300
Inside [mm]
www.ubakus.de Outside

The surface temperature during the day


[°C]
36 Outside
34 Inside
32
30
28
26
24
22
20
18
16
14 Phase shift: 10.2h
12 14 16 18 20 22 24 2 4 6 8 10 12
[time of day]
Top:Temperature profile within the component at different times. From top to bottom, brown lines: at 3 pm, 11 am and 7 am
and red lines at 7 pm , 11 pm and 3 am.
Bottom:Temperature on the outer ( red ) and inner ( blue ) surface in the course of a day. The arrows indicate the location of
the temperature maximum values . The maximum of the inner surface temperature should preferably occur during the
second half of the night.

Phase shift* 10,2 h Heat storage capacity (whole component): 139 kJ/m²K
Amplitude attenuation ** 31,2 Thermal capacity of inner layers: 108 kJ/m²K
TAV *** 0,032
* The phase shift is the time in hours after which the temperature peak of the afternoon reaches the component interior.
** The amplitude attenuation describes the attenuation of the temperature wave when passing through the component. A value of 10
means that the temperature on the outside varies 10x stronger than on the inside, e.g. outside 15-35 °C, inside 24-26 °C.
*** The temperature amplitude ratio TAV is the reciprocal of the attenuation: TAV = 1 / amplitude attenuation
Note: The heat protection of a room is influenced by several factors, but essentially by the direct solar radiation through windows and the
total amount of heat storage capacity (including floor, interior walls and furniture). A single component usually has only a very small
influence on the heat protection of the room.

The calculations presented above have been created for a 1-dimensional cross-section of the component.

Page 4