PRODUCT TECHNICAL MANUAL MICROBASIC’S PRE-ASSEMBLED ELECTRICAL CONTROL INSTALLATION 5.4.5. Control Faults and Statuses When there is a fault in a lift, this Is stored In the MicroBasic board and in the AMB2 board. In the AMB2 board, the same fault code as in the MicroBasic board is stored and the following s also associated to that fault = The lit number. = The level where the fault appearea = The time. = The date, ‘The fault codes displayed by the AMB2 board are the same as those on the MicroBasic board (see list of faults table), ‘except for the fallowing special faults associated to operations with AMB2: + F50: Communications fault. This is produced when communications between AMB2 and one of the MicroBasic controls falls. This code is displayed along with the number of the control to have caused it + F80: Loss of parameters. This arises when itis detected that the configuration parameters of the AMB2 board are incorrect. Fault FBO will then appear. The Ift number infarmation is nat relevant: Review end enter all of the configuration parameters for the AME2 board with their correct value. when fault F60 is detected, the AMB2 board self-configures based on default values that do not consider the specific characteristics of the group of lifts, This allows the Installation to continue operating, although with limited features, When any fault appears, the current 3-digit display on the AMB2 board disappears and the information associated to the fault is displayed cydically Control fault table LIST OF FAULTS TFX¥] y CRUSE, x CAUSE. 1+ | Maximum travel time. 26 [Lift at level and CPS not activated (oleosynamic only) (02* | Lt off Imit or previous series open (before doar), 27 [No CPS switching on passing level (oleodynamic only) ogr_[ Ui parked afer etvatng it wc olneymarig [jg | Hoximum + Winimum pressure sch pan | Contactor stuck 34 | EoREREY ORK ON BEET DF BESET BATON TT ‘05 __| Repeated faults n car door series, 55_| laten series bridged after 8 return ‘06 [Door series open during a service, 60_| Call fitering function ENBT-28 cisabled ‘07 [external latch series open during a sence 61_| OMRON changer function disabled, ‘08 [Pulse miscorrection, 62_| STOP function disabled 09° Control fuse (FM) or power fase (FF) blown, 63 | Out of service light function assbled 19% [Faulks on MieroBasie board. 64_| Permanent out of service key function Gsabled [Door series open longer than defined by TG, (65 | 3C short floor function disablee 1p] Open doors button series, door photocell and 66. | Automatic door and electric cam Function asabied sensitivity open longer than it should be TE_[Luit at intermediate floor with an open pre-Imnk 57_| Attendant mode funcion deabied 14% [Both pre-Lmits open, 68 | U36 standard function dsablec 15e_[ bet petit passing Fom closed open on g9__| Australian Fire Service function ~ Disabled zee [ tse P= it passing Fm closed open on 59 | Sam Step function disabled 17 [Faults in configuration parameters (parameters) 7i_| DSP resus input and output function daabled ‘Communicator ‘aut with frequency changer (only Max-Min pressure switch function disabled is [Sor 72 ‘Manual reset fault ft cannot start operating again ‘ternative Fire Service input Funchion disabled 20 | after'a permanent out of service fault 73 7a Heating resistor Fancion Seabed 4,03 MAR11 5-54 MTIPIEPMa4O3EN

You might also like