Tensile Stresses in End-plate Stiffener, Flange and Web

Actual Tensile Stress = ∑Pi / ti.bi


Allowable Tensile Stress = 0.6 Fy

End-Plate Stiffener
Actual Stress 162.2 N/mm2
Allowable Stress 207.0 N/mm2 >162.2 OK

Flange
Actual Stress 105.7 N/mm2
Allowable Stress 207.0 N/mm2 >105.7 OK

Web due to load from Row # 2


Actual Stress 149.9 N/mm2
Allowable Stress 207.0 N/mm2 >149.9 OK

Web due to load from Row # 3


Actual Stress 202.1 N/mm2
Allowable Stress 207.0 N/mm2 >202.1 OK

Panel Web Shear

Actual shear stress


Shear in panel web = total load in tension bolts in all rows 748 kN
Shear stress in web = shear / web area 116.9 N/mm2

Allowable shear stress


Area of web (h.tw) Aw 6592 mm2
Clear distance b/w transverse stiffeners : Web depth a/h 1
For webs with transverse stiffeners, shear buckling co-efficient kv 9.34
h/tw h/tw 100
Limit 1.10√(kv.E/Fy) 80.9
Limit 1.37√(kv.E/Fy) 100.8
Web Shear Coefficient Cv 0.81
Allowable shear stress, Vw = (Vn/Aw)/Ω = 0.6FyCv/1.67 Vw 100.3 N/mm2 <116.9 NOT OK
Web panel stiffener is required