Professional Documents
Culture Documents
Wilo Fire Fighting - R09 PDF
Wilo Fire Fighting - R09 PDF
Product Catalogue
UL LISTED CERTIFICATE
FM APPROVED CERTIFICATE
2 Installation 5 Versatility
Robust axially split case Product configurations
pumps to cover the main available on request,
needs of commercial or depending on installation
industrial buildings conditions
3 Equipment 6 Maintenance
Elastic coupling with Safe and easy installation
misalignment compensator and maintenance
for electric pump and
universal coupling complies
with UL requirements and is
accepted by FM for diesel
pump
Scope of Supply
Diesel System Electric System Jockey System
Type Key
SCPFF 80-300 DV
SCPFF Pump series
80 Nominal outlet diameter (mm)
300 Nominal impeller diameter (mm)
DV Hydraulic Variant
•DV: Double Volute
•HA: Hydraulic type “A”
•HB: Hydraulic type “B”
Casing Cast Steel (A 216 Gr) Max Operating Pressure 16-25 bar
Impeller Bronze Casting (G-CuSn10) Operating Temperature 10-105 ˚C
Shaft Stainless Steel (SS410) Pump Type Axially split case
Shaft Sleeve Stainless Steel (SS304) Lubrication Grease
Wearing Ring Bronze Casting (G-CuSn10) Direction of Rotation Clockwise
Sealing Gland Packing (Optionally counter-
clockwise)
2 5
Key
2 → UL & FM compliance with NFPA 20 as standard 5 → Switchgear components are UL/FM with CE marking as
→ Static and dynamic characteristics tested directly in standard.
production by Wilo → Designed in full accordance with NFPA 70 (NEC)
→ Designed to ensure high efficiency, and easy installation electrical standards
and maintenance operations → Logic of the control microprocessor based on recording
of the sequence of events following pressure changes
as standard.
→ Protection class IP54
→ Star-delta starting
FM Approval FM Approval
3 → The FM logo ensures that the pump is assembled with 6 → Easytransport thanks to the side eyebolts
FM- approved components in a factory authorised by → Standard base plate consisting of a sturdy steel frame to
FM facilitate on-site operations
→ Paintwork with RAL 3000 colour
3
6
2
5
7
Key
Coupling Baseplate
1 → Universal coupling compliant with UL requirements and 5 → Standard base plate consisting of a sturdy steel frame to
accepted by FM facilitate on-site operations
→ Maintenance-free with maximum operational reliability → Paintwork with RAL 3000 colour
→ Shaft may be moved in axial, radial and angular → Easy transport thanks to the side eyebolts
directions
2 → UL & FM compliance with NFPA 20 as standard 6 → Designed and dimensioned in accordance with NFPA 20
→ Static and dynamic characteristics tested directly in standard
production by Wilo → Single-wall tank as standard
→ Designed to ensure high efficiency, and easy installation
and maintenance operations
Switchgear FM Approval
4 → Switchgear components are UL/FM with CE marking as 8 → The FM logo ensures that the pump is assembled with
standard FM- approved components in a factory authorised by
→ Protection class IP54 FM
→ Simplified installation and maintenance procedures
MOTOR
→ Optional right angle gear drives
→ Vertical hollowshaft of solid shaft
→ Can be supplied with a non-reverse ratchet
→ Top adjusting nut allows user to adjust lateral setting
→ Bearing designed to carry thrust loads and is oil
lubricated
→ Available in WP-I, WP-II, TEFC & Explosion-Proof
enclosures
STUFFING BOX
→ Packed with lantern ring standard
DISCHARGE HEAD → High-pressure stuffing boxes and shaft
→ Stainless steel top shaft sleeves are optional
→ Optional fabricated steel heads available → Grease port for throat bushing
→ Headshaft coupling connects top shaft lubrication
to headshaft
→ High profile head allows for ease in
servicing packing
→ Integral drip basin collects leakage from COLUMN ASSEMBLY
stuffing box → Larger diameter, steel shaft material
→ Spacer couplings are available for use → Heat straightened shafting standard
with VSS motors → Heavy wall carbon steel construction
→ Heavy duty ASTM A48 class 30 cast iron → Product lubricated lineshaft bearings
construction standard → Overall length is engineered to
customer specifications
→ Cast 304 stainless steel bearing
DISCHARGE CASE retainer with cutlass rubber insert
→ Two discharge bearings for additional → Threaded column is standard through
support 12” and flanged for larger sizes
→ Heavy duty ductile iron construction
standard
→ Additional vanes for minimizing
turbulence, thus improving efficiency BOWL ASSEMBLY
→ Bronze bowl bearings standard
→ 416 stainless steel bowlshaft is
standard
STRAINER → Impellers are expertly machined to
customer specifications
→ Basket or cone strainers are available
→ Heavy duty ASTM A48 class 30 cast
upon request
iron construction standard
→ Stainless steel materials are available
→ Heavy duty grease-packed suction
→ Vortex suppressors can be supplied to
case bearing with sand collar
minimize inlet stress
→ Diffuser bowls through 16” have
standard vitreous enamel lining
→ Heavy wall ASTM A48 class 30 cast
iron construction with 304 stainless
steel impellers
→ Tapered impeller collets are used on
bowls through 16” with keyed
impellers used on larger sizes
Performance Specifications
Range of Pumps
Rated Net
Rated Rated Net
Pressure Range Approx Speed
Pump Model Stage(s) Capacity Pressure Range
(psi) (RPM)
(USGPM) (m)
NFPA20Pump
NFPA20 PumpDesign
Design
Wilo – MISO/PISO (ISO 2858) Wilo - RN, HS PLURO, IPB Wilo - ASP
Casing : Cast iron, Ni-CI, cast steel Casing : Cast iron, Ni-CI, cast steel Casing : Cast iron
stainless steel, duplex stainless steel, duplex Impeller : Bronze
stainless steel stainless steel Shaft : Stainless steel (SS410)
Impeller : Cast iron, bronze, stainless Impeller : Castiron, bronze, stainless
steel, duplex stainless steel steel, duplex stainless
Shaft : Stainless steel, steel
Shaft : Stainless steel,
duplex stainless steel
duplex stainless steel
→ Reduced life-cycle costs through → High pressure pump design → Robust design
optimised effisiency levels → Modular design ensures pump version → Customized solutions to meet exact
→ Bidirectional, force - flushed in a variety of materials and versions requirement
mechanical seal which can be adapted to meet → Shaft sleeve to ensure longer shaft
→ Low NPSH values, best cavitation customer demand sprecisely life
properties → Hydraulic pressure compensation → Optimum NPSHr
→ Shaft coupling with or without relieves load on bearings and ensures
→ Low noise and vibration
spacer coupling a longer service life
→ Reduced energy consumption
→ Multiple optional pressure connections
→ Less environmental impact
allow different pressures to be
supplied from a single pump
→ Can be applied as Jockey pump
Vertical Turbine Pump Split Case Pump Jockey Pump - Multistage Pump
Wilo - VMF, CNE, VAF Wilo - SCP, HSC, GME Wilo - Helix First V / EVO
Casing : Cast iron, stainless steel, Casing : Cast Iron Ni-CI, stainless Casing : Cast iron, Stainless steel
cast steel, dupplex stainless steel Impeller : Stainless steel
steel Impeller : Castiron, bronze, stainless Shaft : Stainless steel
Impeller : Castiron, bronze, stainless steel, Ni-CI, duplex stainless
steel, Ni-CI, cast steel, steel
Shaft : Stainless steel, duplex Shaft : Stainless steel, duplex
Stainless steel stainless steel
→ Minimum surface area needed → Robust design → Efficiency- optimised, laser welded
→ High hydraulic efficiency → Customized solution to meet exact optimised 2D/3Dhydraulics
→ Submerged pump hydraulic requirement → Corrosion-resistant impellers, guide
→ Shaft sleeve to ensure longer shaft vanes and stage housing
→ Design to order as per customer
specification life → Flow and degassing-optimised
→ Trust bearing lubrication: Grease, → Low NPSHr hydraulics parts
oil Line shaft bearing lubrication: → Low noise and vibration → Reinforced pump housing, flow and
Self, forced (external) NPSH optimised
→ Reduced energy consumption
→ Bowl Assembly: Pull out or non- → Space-saving and esay maintenance
pull out → Less environmental impact
thanks to compact design
(almost 100% recyclable)
→ Space-saving and esay maintenance
→ Comply to RoHS directive for
thanks to compact design
European countries
→ Particularly sturdy coupling guard
Built Up Controllers
Local Controllers
Local(Refer to NFPA20
Controllers (ReferStd.)
to NFPA20 Std.)
PUMP DRIVER
Diesel Engine ElectricMotor
Electric Motor
Horizontal Split Case Pump c/w Diesel Engine Horizontal Split Case Pump c/w Electric Motor
End Suction Pump c/w Diesel Engine End Suction Pump c/w Electric Motor