Display Type Description Action HW Error A hardware error exists Reset/Replace Unit IDKey IDKey is not connected or Reconnect/replace 2nd Digit: Warnings and errors Error invalid IDKey Display Description Action Recovered from fatal Check power SW Error exception Reset/Reload App Main supply line A missing supply line A Check power Main supply line B missing supply line B Overload on supply to isolated analog input Overload on supply to non- isolated analog input
Overload on supply to digital I/O
Internal power monitor failed Reset/Replace Unit
Trigger or TDC timeout: Engine is stopped or running at a very low speed Direction change: Engine is reversing Too many trigger pulses: System is incorrectly configured or engine is reversing 1st Digit: Modes Data overload: The system is experiencing data overload – Display Description possible causes: noise on trigger signals Bootloader Mode Trigger inconsistency: Different no. of trigger pulses per revolution Test Mode detected – bad encoder setup or adjustment Configuration Mode Missing configuration: PMI-DAU has not been configured with Normal Mode engine parameters Invalid direction: Engine is running Running/calculating astern