Professional Documents
Culture Documents
CST Studio Suite - Release Notes
CST Studio Suite - Release Notes
04 - Release Notes
This service pack is a recommended update, which includes the following corrections and improvements.
Licensing
CST Studio Suite Frontend includes CST Studio Suite Bio Models and CST Studio Suite Multi-Platform
(Linux) Upgrade at no added price. Both, CST Studio Suite Bio Models and CST Studio Suite Multi-
Platform Upgrade will no longer be available as separately orderable add-ons to CST Studio Suite
Frontend.
Changes in 2021.04
General / Environment
CST Power'By
Set usage tag to "CST Studio Suite" but support loading of "CSTModel" for 3DEXPERIENCE R2021x
FD07 and greater.
Show A-Solver farfield cuts in 3DEXPERIENCE Physics Simulation Review and 3DEXPERIENCE
Simulation Manager.
Fixed issue with instancing of sub-assemblies having same name.
Improved selection option of origin (CATIA, SOLIDWORKS or Derived Format Converter) in
3DSearch. New Feature!
Fixed import of parts of an assembly that contain non-locale characters.
Fixed issue when using parametric imports in combination with SOLIDWORKS Connected.
Fixed TLM solver excitation setting inheritance from reference project when creating a simulation
project.
Remove file size restriction while creating simulation projects involving TOUCHSTONE blocks.
Repaired tetrahedral mesh error due to a Boolean add.
Fixed simultaneous excitation inheritance from reference project on simulation project creation.
1
Distributed Computing (DC)
Biological Models
Post-Processing
Enabled support for monitor selection in farfield combine results. New Feature!
Resolved non-existing farfield files when running frequency distributed computing for certain scenarios.
Domain decomposition: repaired solver termination with MPI in some cases with repetitions defined.
Domain decomposition: fixed incomplete 3D power loss monitor results with MPI.
Domain decomposition: improved progress sections with many ports and repaired backward
progression.
Domain decomposition: fixed port power calculation in some cases.
Domain decomposition: repaired solver hang when using repetitions and many excitations with a fine
mesh.
Domain decomposition: fixed solver hang at shutdown.
Domain decomposition: fixed solver termination in special domain setups and repetitions being used.
Domain decomposition: fixed solver termination when lossy metal is touching and intersecting domain
interfaces.
2
Domain decomposition: repaired solver error with repetitions defined that lead to invalid repetition
groups.
The combination of results now works properly even in presence of several mesh adaption frequency
points.
Consider some special cases of symmetries for simultaneous excitations properly.
Improved error message and mesh feedback for local multilayer setup.
Fixed excitation list setup for excited nearfield sources.
Fixed bug causing infinites in farfield calculation when dielectrics are present.
Repaired issue in dialog box setting: Range profile center frequency was ignored.
Impedance Calculator warns if the user picked frequencies outside the analysis range.
Allow some control over the cable curve type from CST Power'By.
Fixed that current calculation was not able to deal with very large .cur input files.
Allow calculation of a conductance matrix also for setups where no static solution can be deduced.
Improved warning message displayed by the full wave frequency domain solver.
Lumped elements defined in other solvers are ignored instead of stopping with error message.
Better accuracy in capacitance calculation.
All off diagonal RLC entries are displayed in navigation tree.
Spark3D
Fest3D
3
Fixed issues with VRM and undefined nets, multi-selection and handling of errors during assignment.
Fixed issue when assigning IBIS component.
Fixed that there was no transmission to a certain net in 2DTL/SI simulation.
Consider touchstone reference pin in PI solver.
Repaired PI Solver field plots in case of elevated ports.
Added simple checker for package devices to detect inconsistencies in logical models.
Provide import/export of PCBS package devices through part library.
Provide alternative package data import through CSV. New Feature!
Package Touchstone ref pin is handled now.
Pin group editor now lists available pins.
Fixed that 2DTL often forgets to consider padshapes along traces. Fixes differences between "search
distance" and "voltage threshold".
Fixed issue when editing the location of a component.
Prevent dash character in pin names.
Fixed issue with visualization of shapes of unknown type.
Fixed issue with repainting of attribute manager.
Fixed issue related to copying/creating simulation projects with TOUCHSTONE blocks with non utf-8 file
encoding.
Fixed issue related to the Macro "Compensate Self Inductance of Discrete Ports" when the block ports
IdEM
Fixed issue in the xml file for the Zuken output format.
Included the support for inactivity timeout. New Feature!
Improved the self-extracting functionality at the initialization phase.
Fixed issue in splitting type control of IdEM-DES.
Fixed issue associated to the labels of data/model in the comparison plot.
Improved label format in Smith chart visualization.
4
LF - Export Admittance/Impedance Matrix as Y/Z-Touchstone: Fixed problem, when using with more
than 4 ports.
Inverse Chirp Z-Transformation - Result Template: allow arbitrary mag/phase input file-names, new
options for numerical filtering.
Changes in 2021.03
General / Environment
Fixed license usage reporting when running in batch mode in 3DEXPERIENCE cloud context.
CST Power'By
Fixed issue when cookie cannot be set while retrieving license data.
Fixed error when trying to load a second project while the first one was still loading.
Fixed setup error in eye analysis task during creation of simulation project task.
Changes in 2021.02
General / Environment
Fixed issue during module start on systems with Chinese Traditional language setting.
Fixed issue with disabled Ribbon buttons.
Improved stability when showing key tips.
Upgraded 3D CAD import to support the latest versions. New Feature!
The cluster integration scripts now support the CHT solver.
Added Google Chrome for Linux on the list of supported browsers.
The F7 modified message is now no longer shown, if a project with 0D monitors is saved and opened
again.
Adjusted fast model update behavior, if a "PEC" or "Vacuum" material is renamed.
5
During Sub-Project import, the material name, which is used inside of a fluid domain, is now correctly
adjusted.
Improved stability when switching between 3D and Farfield plots.
Improved display of patch notes in CST Update Manager and CST Studio Suite.
Fixed wrong help calls in Options dialog box and updated images regarding new Library Paths section.
CST Power'By
Do not show misleading warning "Sub-Project import: External reference cannot be found" in simulation
projects for block import from the main project.
Fixed unwanted invalidation of simulation projects using parameterized clone blocks on changing a
project parameter used only by the cloned block.
Field sources are now imported into simulation projects from blocks selected as 3D, which do not
contain any other geometry. New Feature!
Do not invalidate simulation project after running it when the project was from an older version.
Fixed parametric setting of distributed optimizer runs when using remote post-processing.
Biological Models
CST Bio Models Extension 4.0 is now available for download from the Knowledge Base, it also contains
the cst file for CST Phone 5G TLM Tutorial. New Feature!
Adjusted values of exemplary thermal properties of several glandular tissues to be more realistic.
Post-Processing
5G Post-Processing Wizard: New option to export summary in csv file as well as images of power
density plots. New Feature!
ReportTool: restore 1D plot with multi-selected results in schematic.
Improved handling for large A-solver results.
Avoid endless loop in case of MPI for SystemCheck that leads to huge log files.
Handle LSF command line arguments properly in case of spaces for cluster integration scripts.
New option for HPC cluster simulations to retrieve temporary data and/or additional logging from all
compute nodes.
Adjusted firewall manager to support new MPI locations.
Specify near field source coupling via tangential fields in online help.
Enabled S-Parameter sensitivity dB plot.
Updated online help text for densely sampled near field source data.
6
CST Microwave Studio - Transient Solver
Added support for conducting-wall boundary condition to the Spark3D export tool.
In rare cases with close low frequency samples, the frequency sweep did not provide broadband results.
Increased the results accuracy using non-rectangular numerical discrete face ports and lumped
Enabled the use of preconditioner type 4 with thin-panel defined by S-matrix table.
Generate error message for unsupported thin-panel type using reflection and transmission table.
Fixed Farfield calculation for thick dielectrics when hardware acceleration is active.
Added functionality to switch value for plotting trapped rays in dialog. New Feature!
Fest3D
Resolved behavior in coaxial cavity elements, which could not use parameters in rounding specifications
of the element.
Corrected the behavior where circuits from versions 2018 & 2019 lost their parameters if being imported
directly in the 2021 version.
7
Resolved loss of accuracy in results of a complex example with respect to Fest3D 2020.
Resolved behavior when user uses copy/paste after changing to a different circuit.
Removed warning message provided to the user once a tolerance analysis was finished.
Fixed issue when updating results in CST Studio Suite using a project exported to DES by Fest3D.
Fixed shape plot for Arbitrary Shaped Elements when parameters were used in the element to be plot.
Package with missing electrical connection can cause problems later on. Warn the user when manually
creating such contradictions.
Pick the correct differential partner pin in old projects and handle more cases in exiting checks.
Fixed issue with updating of SP layout when running convenient workflow.
Have additional net name in Eye and Timing result items.
Fixed gap healing to have a 2DTL connection.
Fixed issue with dialog boxes initialization on Linux.
Schematic Editor text fields: The font name and font size comboboxes in the Ribbon now work as
expected.
Added hexagonal shapes for mask violation analysis in eye analysis task. New Feature!
Support rotor skewing for ROM Drive Scenario (also available in EMAG-ROM for Simpack). New
Feature!
Functional Mock-up Unit (FMU) of nonlinear ROM supports extrapolation to handle exceeding machine
currents. New Feature!
Operating Point Look-up FMU features new look-up modes, such as limiting to max motor curve or max
generator curve. Moreover, support negative revolution speed and cover exceeding speed limits by
extrapolation. New Feature!
FMUs in general can handle non-trivial resource locations (space, non-ASCII).
Various fixes for the user interface.
System Simulator
8
"About" icon in SytemSimulator now redirects to 3DS webpage.
Removed MotorCad-Import icon and a corresponding menu item since this functionality is not included
into the SystemSimulator.
Curve and axis colors can now be changed via Outputs Properties dialog box.
IdEM
Fixed error in setting up some IdEMXpress options, options are now preserved.
Fixed error in setting up plot properties of responses plotted in Real/Imag form.
Fixed error in fitting options XML file, custom "bandwidth" parameter is now correctly written.
Fixed discrepancy in the maximum error value when it is visualized in the log and in the figure container.
CST Power'By
New "Export Field Plot to 3DEXPERIENCE Content" post-processing template. New Feature!
Interactive Save operation is now linked to "Save to 3DEXPERIENCE" in Antenna Placement
mode. New Feature!
Fixed hang while loading 3DSearch site.
Wire harnesses defined in the CATIA Electrical 3D Design App can be imported using Connector for
CST (starting with 3DEXPERIENCE 2021xFD04).
Made partial RLC solver available for simulation project creation. New Feature!
Fixed unwanted inherited preselection when creating a new SP.
Improved error message if part download from 3DEXPERIENCE fails for antenna placement.
9
EDA Import / EDA Tools
Fixed an issue with changed values from entries not being used in the import, when directly triggering
Preview/Finish without confirming/defocusing the entry first.
Bending instructions can now choose to define radii either relative to the board surface or relative to the
board center. New Feature!
Fixed issue with importing PCB when stackup-regions extended over the board outline.
Switched off "Copy database to project" for EDA-Import.
CST EM Studio does not support face lumped elements, creating edge lumped element instead.
Hyperlynx Import: Support padstack defined as round instead of Octagon with untypical parameters.
Hyperlynx Import: Support pin names with two ".", corrected wrong arc orientation.
Fixed slow solver initialization with a very large number of field sources.
Fixed problem with a not needed warning when a nearfield source frequency was slightly different from
the simulation frequency.
Fixed problem in computation of results for multiple field source.
Fixed problem in the computation of field monitor.
Fixed problem when rerunning an archived model, which keeps only 1D results.
Added support for filtering rays by maximum length or by number of internal reflections. New Feature!
Added support for ray based field monitor. New Feature!
Fixed mesh import issue during parameter sweep.
Fixed this one: "Creating Transmission Line Model terminated" because of an invalid reference to a
cable screen.
Broadband calculations are now allowed without the activation of impedance calculations.
Fixed impedance calculation in a case of a pure magnetostatic setup.
Partial capacitance results are presented in four different notations in the result tree. New Feature!
Removed misleading solver warning about sheet bodies from EDA import.
Erroneous warnings for helper sheet body at RLC nodes removed.
Spark3D
10
Corrected SPARK3D failure when adding new models to a loading project.
Corrected SEY plot failure when SEY <= 1.
Corrected SPARK3D error when simulating with SEY <= 1.
Corrected SEY plot failure with user defined materials.
Fest3D
System Simulator
Database SystemSimulator is extended to the elements, which contain both conservative and non-
conservative pins. New Feature!
For the imported model-exchanged based FMUs, which are supplied with connection information,
electrical and mechanical pins are shown. New Feature!
Improved stability of the FFT-Display.
IdEM
11
ExportImageToFile now supports non-native path separator.
Fixed issue when using macro "Compensate Self Inductance" on a schematic with already existing
ports.
General Features
General | 3D Modeling
Distributed Computing: Allow distribution of jobs to servers with inhomogeneous GPU count
Added support to protect lumped elements in protected projects
Wrap sheets and curves toward the faces of an arbitrary curved shape
Project curves toward a shape along the surface normal of the target shape
Enhanced healing and analysis of problematic shapes
Convert Discrete Ports to Lumped Elements and vice versa
Meshing
Automatic resolution and reporting of material overlaps for tetrahedral meshing
Tool for full re-meshing of selected shapes to an intersection-free mesh shape
Improved performance of mesh import and support for more keywords of Abaqus and
NASTRAN files
Post-Processing | Results
Report Tool: Copy/paste of report items, import of reports from other CST projects
2D/3D Result Plots: Separate 3D plot sheet, improved arrow plot customization
Far field Plots: Component selection from ribbon, improved 2D plot features
Template Based Post-processing: Copy/paste of defined result templates
Post-processing: Improved monitor calculation after solver run
3D EM Technology
High Frequency Simulation
Djordjevic Sarkar fitting for constant loss material handling (T, TLM, F, I, A)
12
Import of thermal fields for temperature depending materials from CHT Solver or Abaqus
on irregular grid (T)
Automatic absorption of higher order propagating modes (T)
Added F-Parameters for waveguide monitors (T)
Added plane wave to solver excitation list (T)
Support of face lumped elements (TLM)
Robustness improvements for cable meshing (TLM)
Improved performance for initialization of complex models (TLM)
Domain decomposition solver with MPI support for frequency domain calculations on
tetrahedral mesh (F)
Support of generalized port mode solver on hexahedral grids (F)
Adaptive tetrahedral mesh refinement for the Eigenmode solver for general lossy problems
(E)
Inverse synthetic aperture radar (ISAR) analysis (A)
Extended range of applicability for the normal material (lossless) for far field calculation (A)
Added new preconditioner options for MLFMM (I)
Extended range of applicability for the thin panel material (I)
Improved setup of superimposed nearfield source (NFS) excitation during circuit co-
simulation (T)
Hybrid solver task (bi-directional) (SAM task):
Particle Simulation
Added GPU support for E-Static PIC Solver
Added new collision models for particle-particle interactions
13
Particle Losses are now available as a solver results also before running a thermal
simulation
Spark3D
New High power breakdown analysis for pulsed signals
Use of multiple SEY’s when importing the EM fields from CST Studio Suite
BoardCheck
Improved performance of solver start by avoiding copying design data
The design view together with violation results can now be exported to the report tool
Chip Interface
Automatic creation of excitation nodes for Partial RLC solver
Antenna Magus
Find by Value functionality has been improved to allow the specification of values for
frequency, gain and bandwidth. Combined with the existing keyword search, a goodness
factor is used to indicate the suitability of any given device.
Constructions are more practical / realistic export assembly models. These are constructed
using existing building blocks already contained in Antenna Magus.
Variations, or helper models, are export models provided in addition to standard original
export models for a given device. Variations provide the user with useful model variations,
for example a horn with a lens variation, a patch with a superstrate variation or an absorber-
lined cavity spiral with a cylindrical cover variation.
Radome Library with fully parametric exportable geometries has been added
A number of new antennas and transitions have been added to the database.
14
Control hide and show of individual harness elements like cable bundles or harness
segments
Improved transfer impedance models: More robust circuit models and new export of
transfer impedance curves in text format
Current monitors in cable segments probe the current of each wire as well as the common
mode current
Electric boundary is now supported not only for bi-directional simulation but also for no-
coupling and uni-directional setups
Improved accuracy of lossless circuit models for the cable simulation
Improved random bundling: Possibility to control the strength of the randomness and to
define the position of certain cables as fixed
Circuit Simulation
Improved creation of Busses and display of pins and pin groups
Improved transient simulation performance
Extended Clone Block: Support for parametric cloning of 3D Project Blocks
Improved Touchstone Block: Parametric access to multiple Touchstone files
Option to use IDEM macro modeling for S-Parameter based blocks
Unified user interface for blocks
New Eye Diagram task with mask violation detection and size measurement
Multi-Physics Simulations
Thermal Simulation
CHT Solver
Support for liquid cooling
Full support for transient simulations
Support for Distributed Computing (DC)
Support for k–omega (k–ω) and Spalart-Allmaras turbulence models
15
Support for initial conditions on solids and fluid domains
Import of IR-Drop Losses
Import of temperature fields generated by the CHT solver (JS, LF FD, F, T)
Performance improvements for temperature field and loss imports
16