You are on page 1of 4

Thu Jan 03 08:25:01 COT 2019

Features: 3HSWYAHTX7N539726

Feature Description
0595008 ESC PROG, AIR PRESSURE GAUGE/AIR BRAKE
0595014 ESC PROG, PARK BRAKES W/IND LIGHT
0595015 ESC PROG, BRAKE SWITCH
0595017 ESC PROG, ENGINE COMPRESS BRAKE
0595018 ESC PROG, HEADLIGHTS DAY/RUN
0595019 ESC PROG, FOG LIGHT ACCOMM PACKAGE
0595021 ESC PROG, TURN SIGNAL/BRAKE
0595022 ESC PROG, AIR HORN W/ OR WITHOUT SWITCH.
0595023 ESC PROG, ELECTRIC HORN CITY
0595024 ESC PROG, DOME LIGHT W/DIM
0595027 ESC PROG, DIAGNOSTICS
0595030 ESC PROG, TRAILER MARKER LIGHT
0595031 ESC PROG, IGNITION KEY
0595037 ESC PROG, CLUTCH SWITCH
0595041 ESC PROG, POWER DIVIDER LOCK
0595048 ESC PROG, LOW WASHER FLUID W/LIGHT
0595049 ESC PROG, ELECT PARAM DEFAULT SETTINGS
0595051 ESC PROG, ENGINE FAN OVERRIDE
0595061 ESC PROG, VOLTMETER
0595063 ESC PROG, SEAT BELT IND LIGHT
0595066 ESC PROG, ENGINE OIL PRESS GAUGE
0595067 ESC PROG, ENGINE COOLANT TEMP GAUGE
0595069 ESC PROG, VEHICLE SPEED GAUGE
0595079 T/R DATA, WARNING LIGHTS
0595080 ESC PROG, AIR SOLENOID POWER
0595083 ESC PROG, CRUISE CONTROL SWITCH STATE
0595084 ESC PROG, ENGINE FAN REQUEST
0595085 ESC PROG, GAUGE CLUSTER ALARM HANDLER
0595086 ESC PROG, DUAL REAR AXLE TEMP GAUGE
0595095 ESC PROG, ENGINE STATE
0595097 ESC PROG, OIL TEMP GAUGE ENGINE
0595102 ESC PROG, CRUISE/RESCM OUTPUT HANDLER
0595103 ESC PROG, HARDWIRE CONFIG DATA MD ONLY
0595104 ESC PROG, NETWORK CONFIG DATA MD ONLY
0595105 ESC PROG, IP CONFIG DATA MD ONLY
0595107 ESC PROG, POWER WINDOWS & LOCKS, 2 DOORS
0595111 ESC PROG, MARKER INTERRUPT SWITCH
0595112 T/R DATA, NO PRNDL
0595127 T/R DATA, ENGINE TYPE CUMMINS
0595143 T/R DATA, METRIC GAUGES
0595145 ESC PROG, TRANS OIL TEMP GAUGE MANUAL
0595161 ESC PROG, FOG LIGHTS - OMIT LAMPS
0595162 ESC PROG, OMIT STOP AND REAR TAIL LOW CURRENT AND OPEN CIRCUIT DIAGNOSTICS
0595192 ESC PROG, DUAL FUEL TANKS W/ RELAY DRIVEN PUMP
0595207 ESC PROG, PTO SWITCH CRUISE ENABLE, engine speed control feature
0595208 ESC PROG, ENGINE SPEED GAUGE (4000RPM)

Página 1

Página 2 de 23
Thu Jan 03 08:25:01 COT 2019

Features: 3HSWYAHTX7N539726

Feature Description
0595234 ESC PROG, BATTERY FEED FUSE DETECTION, ESC2
0595250 ESC PROG, WORK LIGHT W/TIMER & KEYLESS ENTRY
0595251 ESC PROG, PARKING/MARKER W/15AMP FUSE
0595253 ESC PROG, WINDSHIELD WIPER, ESC2
0595311 ELECTRICAL SYSTEM CONTROLLER, NVM, FOR TRUCK
0595329 ESC PROG, IDLE WARNING SHUTDOWN IND LIGHT
0595336 ESC PROG, REFRIGERANT CONTROL HVAC W/LIGHT IN LOWER CLUSTER

Página 2

Página 3 de 23
Aborting due to error:null
Thu Jan 03 08:25:01 COT 2019

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
1875 Air_Solenoid_Power_Hi_Current 10 A Air Solenoid Power High Current Detection Level (Amps) 10000 mA
1874 Air_Solenoid_Power_Lo_Current 0 A Air Solenoid Power Low Current Detection Level (Amps) 0 mA
1876 Air_Solenoid_Power_OC_Current 0 A Air Solenoid Power Open Circuit Detection Level (Amps) 0 mA
Autolock speed. The speed at which the vehicle doors will lock automatically (requires power
locks); Setting this parameter to zero will disable Auto Door Locks.
652 AutoLock_Speed 24,140000 kph 6180 kph/256
This defines the amount of time that the AC compressor clutch must be disengaged before it can
be reengaged. The value is defined in section 5.3.1.1.2 (tacc_off). This constant is used to
reload the BC_RCD_Compressor_OFF_Timer.
1933 BC_RCD_Compressor_OFF_Time 8 s 800 timercounts
This defines the amount of time that the AC compressor clutch must be engaged before it can be
disengaged. The value is defined in section 5.3.1.1.2 (tacc_on). This constant is used to reload
the BC_RCD_Compressor_ON_Timer.
1934 BC_RCD_Compressor_ON_Time 7 s 700 timercounts
1935 BC_RCD_Fan_ON_Time 60 s 6000 timercounts
2402 BC_RCD_Head_Press_Cycle_Limit 60 No_Units 60 No_Units
Parameter that controls the number or times the HVAC software will try to engage the
compressor clutch for high head pressure.
2403 BC_RCD_Head_Press_Retry_Limit 2 No_Units 2 No_Units
If the static system pressure is too low because of the cold ambient temperature, the AC
compressor clutch should not be engaged. This parameter defines the pressure below which the
275,
system should not operate. For more information, see section 5.3.1.4.2.
8000000000000
1926 BC_RCD_Pressure_Cold_Ambient kPa 400 psig*10
2404 BC_RCD_Pressure_Cycle_Time 9 s 900 timercounts
1275- Once the system pressure falls below the set point defined by this parameter, the engine-cooling
0000000000000 fan is no longer requested on by the system provided BC_RCD_Fan_ON_Timer has expired.
1927 BC_RCD_Pressure_Fan_Off kPa 1850 psig*10
1965, Once the system pressure rises above the set point defined by this parameter, the engine-cooling
0000000000000 fan is requested on by the system.
1928 BC_RCD_Pressure_Fan_On kPa 2850 psig*10
2757- Once the filtered system pressure rises above the pressure set by this parameter, the system will
000000000000 disengage the compressor clutch, stop operating and log a Service Now fault.
1929 BC_RCD_Pressure_High_Head kPa 4000 psig*10

Página 1