You are on page 1of 10

Fri Apr 09 13:35:32 COT 2021

Features: 3HAWYAHT2HL466658

Feature Description
0595AAC BC PROG, KEY STATE
0595AAD BC PROG, BRAKE SWITCH
0595AAH BC PROG, LIGHTS ON W/WIPERS
0595AAL BC PROG, TURN SIGNALS/BRAKE With Combined Stop and Turns
0595AAP BC PROG, CRUISE CONTROL ON STEERING WHEEL
0595AAV BC PROG, HORN ELECTRIC
0595AAZ BC PROG, PARK BRAKE INDICATOR
0595ABA BC PROG, SEATBELT INDICATOR
0595ABB BC PROG, AIR PRESSURE GAUGES
0595ABC BC PROG, TRAILER LIGHTING
0595ABJ BC PROG, ENGINE TYPE MFG Cummins/ PSI
0595ABK BC PROG, ENGINE COOLANT TEMP
0595ABL BC PROG, ENGINE OIL PRESS GAUGE
0595ABM BC PROG, TACHOMETER 2500 RPM
0595ABN BC PROG, SPEEDOMETER
0595ABP BC PROG, VOLTMETER
0595ABV BC PROG, ABS INDICATOR for Full Power Hydraulic OR Air Brake Systems, Not Including Trailer
0595ACE BC PROG, FOG LIGHTS Rocker Switch
0595ACG BC PROG, OUTSIDE TEMP MONITOR
0595ACU BC PROG, LOCKING DIFFERENTIAL for Single & Dual With Single Switch
0595ACW BC PROG, ENGINE FAN OVERRIDE Includes Manual Switch for Automatic Manual Fan Control
0595ACZ BC PROG, POWER DIVIDER LOCK
0595ADP BC PROG, CLUTCH SWITCH
0595ADR BC PROG, PRNDL No PRNDL, Manual Transmission
0595ADX BC PROG, MONITOR ENG OIL TEMP Through ECM
0595AHT BC PROG, FOG LIGHTS OMIT DIAGNOSTICS
BC PROG, WIPERS W/SPD OVERRIDE Includes Hi, Lo and Intermittent Speeds Plus Washer Effects, Wiper Will be Forced to Slow Intermittent With Park Brake Set and Wiper Left
On for a Pre-determined time
0595AJD
0595AJE BC PROG, WORK LHT DIAGNOSTICS OMIT
0595AJZ BC PROG, PTO CONTROL LOGIC for Dash Switch
0595AKY BC PROG, DOME LIGHTS
0595ALB BC PROG, HEADLIGHTS W/DRL Less Auto
0595ALD BC PROG, AIR HORN Digital Input
0595ALT BC PROG, FUEL TANK GAUGE Single Left Side
0595ALW BC PROG, STOP/TURN/PARK/MARKER DIAGNOSTICS OMIT
0595AMP BC PROG, HEATED MIRRORS in Push Button Location A
0595AMU BC PROG, WORK LIGHT Rocker Switch
0595AMZ BC PROG, PTO SHIFT for Customer Provided PTO, Mounted on Dash, With Programmable Parameters for, Engagement, Disengagement, and Reengagement
0595ANE BC PROG, ENGINE COMPRESSION BR Located in Switch Pack
0595ANP BC PROG, BRAKE APPL GAUGE IN EGC/AGSP
0595ANS BC PROG, MAX. ENGINE OIL TEMP Before the Warn Indicator Light is Activated
0595ANW BC PROG, DIAGNOSTICS LOCATION Display in Gauge Cluster
0595AYA BC PROG, AXLE TEMP GAUGE Dual (AGSP)
0595AYC BC PROG, WINDSHIELD WIPER Without Low Washer Fluid Indicator
0595AYD BC PROG, LOW WASHER FLUID IND.
0595AZY Exterior Lamp Check for MD, RH, & SS vehicles with Push Button

Página 1

Página 2 de 34
Fri Apr 09 13:35:32 COT 2021

Features: 3HAWYAHT2HL466658

Feature Description
0595AZZ BC PROG, PARK / MARKER LIGHTS Dual Output, 20AMP
0595BBB BC PROG, ENGINE FAN OVERRIDE for Low Air Pressure, No Switch
0595BBM BC PROG, ENGINE IDLE SHUTDOWN 2010 Indicator Light in Cluster Warning that Engine Ready to Shutdown
0595BHK BC PROG, HVAC In Cab With Switch Controls (Bergstrom)
0595BJH BC PROG, IP CONFIGURATION for MD, RH, & SS, for 2010 Cluster
0595BJL BC PROG, TRACTION CONTROL IND {Bendix ATC Off Road} 2010, With Traction Warning Light, for Air Brakes
0595BYD BC PROG, BODY CONTROLLER for Truck GEN 4, 502 Hardware

Página 2

Página 3 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
This defines the amount of time that the AC compressor clutch must be disengaged before it can
be reengaged. The value is defined in section 5.3.1.1.2 (tacc_off). This constant is used to
reload the BC_RCD_Compressor_OFF_Timer.
1933 BC_RCD_Compressor_OFF_Time 8 s 800 timercounts
This defines the amount of time that the AC compressor clutch must be engaged before it can be
disengaged. The value is defined in section 5.3.1.1.2 (tacc_on). This constant is used to reload
the BC_RCD_Compressor_ON_Timer.
1934 BC_RCD_Compressor_ON_Time 7 s 700 timercounts
1935 BC_RCD_Fan_ON_Time 30 s 3000 timercounts
1620, Once the system pressure falls below the set point defined by this parameter, the engine-cooling
000000000000 fan is no longer requested on by the system provided BC_RCD_Fan_ON_Timer has expired.
1927 BC_RCD_Pressure_Fan_Off kPa 2350 psig*10
2171- Once the system pressure rises above the set point defined by this parameter, the engine-cooling
000000000000 fan is requested on by the system.
1928 BC_RCD_Pressure_Fan_On kPa 3150 psig*10
Five-short
beeps
2366 Battery_Volt_Alarm_Ty_Gen_2 No_Units 4 No_Units
122 Battery_Voltage_Filter_Param 255 No_Units Voltmeter update rate. A value of 1 is the slowest and 255 is the fastest update rate. 255 No_Units
1943 Battery_Voltage_Max_WL 15 V Maximum set point for battery voltage in-gauge warning light 300 V/20
1944 Battery_Voltage_Min_WL 12 V Minimum set point for battery voltage in-gauge warning light 240 V/20
1994 Blank_Gauge_NULL_Param 0 No_Units This parameter guarantees the a return value of 0. Used for blank gauge data. 0 No_Units
Brake application gauge update rate. A value of 1 is the slowest and 255 is the fastest update
rate.
128 Brake_App_Filter_Param 255 No_Units 255 No_Units
2343 Brake_App_Max_WL 262140 kPa Maximum set point for brake application in-gauge warning light 65535 kPa*4
2424 Brake_App_Max_WL_Gen2_AGSP 1036 kPa 259 kPa*4
2337 Brake_App_Min_WL 262140 kPa 65535 kPa*4
2423 Brake_App_Min_WL_Gen2_AGSP 0 kPa 0 kPa*4
Activate/deactivate daytime running lights. A value of 1 activates and a value of 0 deactivates
the lights.
188 DTRL_Enabled On/Off 1 On/Off
Programmable parameter specifying the diagnostic suppression level for Gen 2. Level 0 means
no suppression, level 1 means suppress outgoing diagnostic messages (DM1, DM2, DM4).
2434 Diag_Suppress_Level 0 No_Units 0 No_Units
2386 Diff_Lock_Engmt_Spd 32,1900 kph This parameter is the maximum speed that the differential can become locked. 8240 kph/256
Enable/disable dome light theatre dimming. A value of 1 enables and a value of 0 disables the
dimming feature.
177 Dome_Light_Dim_Enable On/Off 1 On/Off
178 Dome_Light_Dim_Step_Size 1 percent The size(in percentages)that the Dome_Light_Req should be stepped down each loop. 1 percent
1896 Dome_Light_Hi_Current 10 A Dome Light High Current Detection Level (Amps) 10000 mA
The amount of time that the dome light will remain on after the truck is turned off and the door
is left open.
2213 Dome_Light_Key_Off_Timeout 10 min 10 min
1895 Dome_Light_Lo_Current 0 A Dome Light Low Current Detection Level (Amps) 0 mA
1897 Dome_Light_OC_Current 0 A Dome Light Open Circuit Detection Level (Amps) 0 mA
179 Dome_Light_PWM_Percent_Level 80 percent The level at which the dome light should be set at while it is waiting to dim 80 percent
182 Dome_Light_Wait_Time 20 s This is the amount of time the dome light should wait before dimming. 2000 timercounts
1902 Elec_City_Horn_Hi_Current 12 A Electric City Horn High Current Detection Level (Amps) 12000 mA
1901 Elec_City_Horn_Lo_Current 50 A Electric City Horn Low Current Detection Level (Amps) 500 mA
1903 Elec_City_Horn_OC_Current 50 A Electric City Horn Open Circuit Detection Level (Amps) 500 mA

Página 1

Página 4 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
One-time Five-
short-beeps
2347 Eng_Oil_Press_Alrm_Ty_Param No_Units A list of alarm types codes to teach/reteach the cluster. 4 No_Units
Engine oil pressure gauge update rate. A value of 1 is the slowest and 255 is the fastest update
rate.
215 Eng_Oil_Press_Filter_Param 255 No_Units 255 No_Units
2376 Eng_Oil_Press_Max_WL 262140 kPa Maximum set point for engine oil pressure in-gauge warning light 65535 kPa*4
1948 Eng_Oil_Press_Min_WL 48 kPa Minimum set point for engine oil pressure in-gauge warning light 12 kPa*4
One-time Five-
short-beeps
2354 Eng_Oil_Temp_Alrm_Ty_Param No_Units A list of alarm types codes to teach/reteach the cluster. 4 No_Units
Engine oil temperature gauge update rate. A value of 1 is the slowest and 255 is the fastest
update rate.
219 Eng_Oil_Temp_Filter_Param 255 No_Units 255 No_Units
2274 Eng_Oil_Temp_Max_WL 122,20000 C Maximum set point for engine oil temperature in-gauge warning light 12647 K/32
2291 Eng_Oil_Temp_Min_WL 1774-00000 C Minimum set point for engine oil temperature in-gauge warning light 65535 K/32
2351 Eng_Speed_Alrm_Ty_Param No Alarm No_Units 0 No_Units
223 Eng_Speed_Filter_Param 255 No_Units Tachometer update rate. A value of 1 is the slowest and 255 is the fastest update rate. 255 No_Units
2323 Eng_Speed_Max_WL 8191-000 RPM Maximum set point for engine speed in-gauge warning light 65535 RPM/8
2326 Eng_Speed_Min_WL 8191-000 RPM 65535 RPM/8
Five-short
beeps
2358 Eng_Watr_Temp_Alrm_Ty_Param No_Units 4 No_Units
Engine coolant temperature gauge update rate. A value of 1 is the slowest and 255 is the fastest
update rate.
227 Eng_Watr_Temp_Filter_Param 255 No_Units 255 No_Units
2292 Eng_Watr_Temp_Max_WL 110 C Maximum set point for engine coolant temperature in-gauge warning light 150 C+40
2293 Eng_Watr_Temp_Min_WL 65495 C Minimum set point for engine coolant temperature in-gauge warning light 65535 C+40
If the parameter is set to true the kernel would process the engine fan speed request from DLB.
If false, kernel would ignore the engine fan speed value that is requested from DLB(Caution :
Setting this parameter to ON would override the engine fan speed logic that is currently in
production)
2781 Engine_Fan_DLB_Request_Enabled On/Off 0 On/Off
2230 Ext_Lamp_Test_Seq_Time 2 s 200 timercounts
265 Fuel_Level_Filter_Param 30 No_Units Fuel level gauge update rate. A value of 1 is the slowest and 255 is the fastest update rate. 30 No_Units
2305 Fuel_Level_Max_WL_Gen2 26214 percent Maximum set point for fuel level in-gauge warning light 65535 percent/2.5
1958 Fuel_Level_Min_WL 12,8 percent Minimum set point for fuel level in-gauge warning light 32 percent/2.5
2498 Fwd_Axle_TempC_Max_Gen2_WL 116 C Gen2 parameter for MD Refresh, not ProStar. Config UOM for AGSP in C, not C+40. 116 C
2499 Fwd_Axle_TempC_Min_Gen2_WL 38 C Gen2 parameter for MD Refresh, not ProStar. Config UOM for AGSP in C, not C+40. 38 C
Fwd_Axle_Temperature_Alarm_ Five-short This is for a MD Refresh vehicle. Fwd axle temperature gauge alarm. A 4 tells the EGC that 5
Gen2 beeps short beeps is the alarm type.
2500 No_Units 4 No_Units
Forward rear axle temperature gauge update rate. A value of 1 is the slowest and 255 is the
fastest update rate.
277 Fwd_RR_Axle_Temp_Filter_Param 255 No_Units 255 No_Units
Five-short
beeps
510 Fuel_Level_Alrm_Ty_Param No_Units 4 No_Units
2562 HVAC_Compressor_HP_OFF_Time 9 s 900 timercounts
2561 HVAC_Compressor_HP_ON_Time 1 s 100 timercounts
3094 HVAC_Compressor_LP_OFF_Time 14 s 1400 timercounts

Página 2

Página 5 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
HVAC_Emergency_Shutdown_ 3309,
Pressure 000000000000
2563 kPa 4800 psig*10
2,
4440000000000000
2551 HVAC_Freeze_Probe_High_Limit V High limit for Freeze Probe to allow Compressor to operate. 500 A2Dcounts
2,
4780000000000000
2542 HVAC_Freeze_Probe_Low_Limit V 507 A2Dcounts
HVAC_Leave_HiPressureMode_ When leaving High Pressure Mode, this is the amount of time to wait for the pressure to drop
Timeout below 300 psi before going to Normal Operation (Compressor ON) Mode
2576 15 s 1500 timercounts
1723-
0000000000000
2548 HVAC_Max_Initial_Pressure kPa 2500 psig*10
2757-
000000000000
2546 HVAC_Pressure_High_Limit kPa 4000 psig*10
275,
8000000000000
2556 HVAC_Pressure_Low_Limit kPa Low limit allowed to turn On Compressor 400 psig*10
3447,
0000000000000
2573 HVAC_Pressure_Over_Limit kPa 5000 psig*10
2348 LH_Brake_App_Alrm_Ty_Param No Alarm No_Units 0 No_Units
Deactivate/activate headlights on with wipers. A value of 1 is used to activate and a value of 0
is used to deactivate headlights on with wipers.
317 Lights_on_with_Wipers On/Off 1 On/Off
1911 LT_FT_Turn_Hi_Current 10 A Left Front Turn Signal High Current Detection Level (Amps) 10000 mA
1910 LT_FT_Turn_Lo_Current 50 A Left Front Turn Signal Low Current Detection Level (Amps) 500 mA
1912 LT_FT_Turn_OC_Current 50 A Left Front Turn Signal Open Circuit Detection Level (Amps) 500 mA
1905 LT_RR_Turn_Hi_Current 10 A Left Rear Turn Signal High Current Detection Level (Amps) 10000 mA
1904 LT_RR_Turn_Lo_Current 0 A Left Rear Turn Signal Low Current Detection Level (Amps) 0 mA
1906 LT_RR_Turn_OC_Current 0 A Left Rear Turn Signal Open Circuit Detection Level (Amps) 0 mA
2309 Left_Fog_Light_Hi_Current 10 A 10000 mA
2310 Left_Fog_Light_Lo_Current 0 A 0 mA
2311 Left_Fog_Light_OC_Current 0 A 0 mA
2276 Left_Highbeam_Hi_Current 10 A High Beam Headlight High Current Detection Level (Amps) 10000 mA
2281 Left_Highbeam_Lo_Current 50 A High Beam Headlight Low Current Detection Level (Amps) 500 mA
2280 Left_Highbeam_OC_Current 50 A High Beam Headlight Open Circuit Detection Level (Amps) 500 mA
2285 Left_Lowbeam_Hi_Current 10 A Low Beam Headlight High Current Detection Level (Amps) 10000 mA
2286 Left_Lowbeam_Lo_Current 50 A Low Beam Headlight Low Current Detection Level (Amps) 500 mA
2287 Left_Lowbeam_OC_Current 50 A Low Beam Headlight Open Circuit Detection Level (Amps) 500 mA
2302 Left_Mirror_Heat_Hi_Current 10 A Mirror Heat High Current Detection Level (Amps) 10000 mA
2301 Left_Mirror_Heat_Lo_Current 50 A Mirror Heat Low Current Detection Level (Amps) 500 mA
2300 Left_Mirror_Heat_OC_Current 50 A Mirror Heat Open Circuit Detection Level (Amps) 500 mA
Load shed at
first level
2369 Load_Shed_Level_Fog_Lights No_Units 1 No_Units
shed at first
level
2327 Load_Shed_Level_Work_Light No_Units 1 No_Units

Página 3

Página 6 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
Load Shed
level 1
2360 Load_Shed_Mirror_Heat_Level No_Units 1 No_Units
2388 Max_Diff_Lock_Spd 40,230000 kph This parameter is the speed the differential will be unlocked automatically. 10300 kph/256
Each increment of 1 is equal to 5 minutes. A value of 1 through 12 allows the mirror heat feature
to time out 5 minutes to 60 minutes, a value of 0 leaves mirror heat on indefinitly.
338 Mirror_Heat_Timeout_Enable 0 No_Units 0 No_Units

1938 PDL_Buzzer_Parameter On/Off Setting this to 1 will sound an alarm whenever the PDL is engaged. 0 On/Off
2383 PDL_Warning_Spd 160,90000000 kph 41199 kph/256

2349 Park_Brake_Reminder On/Off 0 On/Off


2451 Park_Light_Circ1_Hi_Current 10 A Park & ID Lights Circuit #1 High Current Detection Level (Amps) 10000 mA
2453 Park_Light_Circ1_Lo_Current 0 A Park & ID Lights Circuit #1 Low Current Detection Level (Amps) 0 mA
2455 Park_Light_Circ1_OC_Current 0 A Park & ID Lights Circuit #1 Open Circuit Detection Level (Amps) 0 mA
2452 Park_Light_Circ2_Hi_Current 10 A Park & ID Lights Circuit #2 High Current Detection Level (Amps) 10000 mA
2454 Park_Light_Circ2_Lo_Current 0 A Park & ID Lights Circuit #2 Low Current Detection Level (Amps) 0 mA
2456 Park_Light_Circ2_OC_Current 0 A Park & ID Lights Circuit #2 Open Circuit Detection Level (Amps) 0 mA
Repetitive
One-Short_
Beep
2319 Prim_Air_Press_Alrm_Ty_Param No_Units 7 No_Units
Primary air pressure gauge update rate. A value of 1 is the slowest and 255 is the fastest update
rate.
375 Prim_Air_Press_Filter_Param 255 No_Units 255 No_Units
2315 Prim_Air_Press_Max_WL 524280 kPa Maximum threshold for primary air pressure in-gauge warning light 65535 kPa*8
2316 Prim_Air_Press_Min_WL 480 kPa Minimum threshold for primary air pressure in-gauge warning light 60 kPa*8
Prim_Sec_Press_Gauge_EGC_ Delay the sounding of EGC alarm until the EGC warning lamp of either Primary and Secondary
Alarm_Delay Air Pressure Gauges is turned ON when Auto Start Stop feature is present.
3194 6 s 600 timercounts
RCD_AC_Comp_Clutch_Hi_
Current
1893 10 A RCD Air Conditioning Compressor Clutch High Current Detection Level (Amps) 10000 mA
RCD_AC_Comp_Clutch_Lo_
Current
1892 50 A RCD Air Conditioning Compressor Clutch Low Current Detection Level (Amps) 500 mA
RCD_AC_Comp_Clutch_OC_
Current
1894 50 A RCD Air Conditioning Compressor Clutch Open Circuit Detection Level (Amps) 500 mA
1914 RT_FT_Turn_Hi_Current 10 A Right Front Turn Signal High Current Detection Level (Amps) 10000 mA
1913 RT_FT_Turn_Lo_Current 50 A Right Front Turn Signal Low Current Detection Level (Amps) 500 mA
1915 RT_FT_Turn_OC_Current 50 A Right Front Turn Signal Open Circuit Detection Level (Amps) 500 mA
1908 RT_RR_Turn_Hi_Current 10 A Right Rear Turn Signal High Current Detection Level (Amps) 10000 mA
1907 RT_RR_Turn_Lo_Current 0 A Right Rear Turn Signal Low Current Detection Level (Amps) 0 mA
1909 RT_RR_Turn_OC_Current 0 A Right Rear Turn Signal Open Circuit Detection Level (Amps) 0 mA
2485 Rear_Axle_TempC_Max_Gen2_WL 116 C Gen2 parameter for NGV, not LH. Config UOM for AGSP in C, not C+40. 116 C
2486 Rear_Axle_TempC_Min_Gen2_WL 38 C Gen2 parameter for NGV, not LH. Config UOM for AGSP in C, not C+40. 38 C
Rear_Axle_Temperature_Alarm_ Five-short This is for a MD Refresh vehicle. Rear axle temperature gauge alarm. A 4 tells the EGC that 5
Gen2 beeps short beeps is the alarm type.
2415 No_Units 4 No_Units
Rear rear axle temperature gauge update rate. A value of 1 is the slowest and 255 is the fastest
update rate.
519 Rear_RR_Axle_Temp_Filter_Param 255 No_Units 255 No_Units

Página 4

Página 7 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
2312 Right_Fog_Light_Hi_Current 10 A 10000 mA
2313 Right_Fog_Light_Lo_Current 0 A 0 mA
2314 Right_Fog_Light_OC_Current 0 A 0 mA
2282 Right_Highbeam_Hi_Current 10 A High Beam Headlight High Current Detection Level (Amps) 10000 mA
2283 Right_Highbeam_Lo_Current 50 A High Beam Headlight Low Current Detection Level (Amps) 500 mA
2284 Right_Highbeam_OC_Current 50 A High Beam Headlight Open Circuit Detection Level (Amps) 500 mA
2288 Right_Lowbeam_Hi_Current 10 A Low Beam Headlight High Current Detection Level (Amps) 10000 mA
2289 Right_Lowbeam_Lo_Current 50 A Low Beam Headlight Low Current Detection Level (Amps) 500 mA
2290 Right_Lowbeam_OC_Current 50 A Low Beam Headlight Open Circuit Detection Level (Amps) 500 mA
2299 Right_Mirror_Heat_Hi_Current 10 A Mirror Heat High Current Detection Level (Amps) 10000 mA
2298 Right_Mirror_Heat_Lo_Current 50 A Mirror Heat Low Current Detection Level (Amps) 500 mA
2297 Right_Mirror_Heat_OC_Current 50 A Mirror Heat Open Circuit Detection Level (Amps) 500 mA
Repetitive
One-Short_
Beep
2321 Sec_Air_Press_Alrm_Ty_Param No_Units 7 No_Units
Secondary air pressure gauge update rate. A value of 1 is the slowest and 255 is the fastest
update rate.
543 Sec_Air_Press_Filter_Param 255 No_Units 255 No_Units
2329 Sec_Air_Press_Max_WL 524280 kPa The Display UOM has changed for LH from kpa*4 to kpa*8 65535 kPa*8
2331 Sec_Air_Press_Min_WL 480 kPa The config UOM has changed from kPa*4 to kPa*8 60 kPa*8
Enable/disable stoplights override hazard lights. A value of 1 enables and a value of 0 disables
the feature.
2317 Stop_Override_Hazard_Enabled On/Off 1 On/Off
if this Parameter is 1, the PTO will be reengaged after a disengage due to low vehicle air
pressure when the primary air pressure is over TEM_PTO_Air_Pres_Engmnt_Limit
2124 TEM_PTO_Air_Pres_Allow_ReEng On/Off 0 On/Off
2116 TEM_PTO_Air_Pres_DisEng_Limit 552 kPa see TEM_PTO_Air_Pres_Disengages 552 kPa
if this Parameter is 1, the PTO will be disengaged if the primary air pressure is below the value
set in TEM_PTO_Air_Pres_DisEng_Limit
2115 TEM_PTO_Air_Pres_Disengages On/Off 1 On/Off
If this Parameter is 1, the PTO will not be engaged if the primary vehicle air pressure is below
TEM_PTO_Air_Pres_Engmnt_Limit
2097 TEM_PTO_Air_Pres_Engmnt_Inhib On/Off 1 On/Off
2098 TEM_PTO_Air_Pres_Engmnt_Limit 621 kPa See TEM_PTO_Air_Pres_Engmnt_Inhib 621 kPa

2095 TEM_PTO_Brake_Engmnt_Inhib On/Off If this Parameter is 1, the PTO will not be engaged if the brake pedal is not depressed 0 On/Off

2094 TEM_PTO_Cltch_Engmnt_Inhib On/Off If this Parameter is 1, the PTO will not be engaged if the clutch pedal is not depressed 0 On/Off

2137 TEM_PTO_Eng_Run_Alarms On/Off if this Parameter is 1, an alarm will sound if the PTO is engaged and the engine is turned off 0 On/Off
if this Parameter is 1, the PTO will be reengaged after a disengage due to the engine stopping
when the engine is restarted
2122 TEM_PTO_Eng_Run_Allow_ReEng On/Off 0 On/Off

2114 TEM_PTO_Eng_Run_Disengages On/Off If this Parameter is 1, the PTO will be disengaged if the engine is turned off 0 On/Off

2096 TEM_PTO_Eng_Run_Engmnt_Inhib On/Off If this Parameter is 1, the PTO will not be engaged if the engine is not running 0 On/Off
if this Parameter is 1, the PTO will be reengaged after a disengage due to engine overspeed
when the engine speed is below TEM_PTO_Eng_Spd_Engmnt_Limit
2120 TEM_PTO_Eng_Spd_Allow_ReEng On/Off 1 On/Off
2113 TEM_PTO_Eng_Spd_DisEng_Limit 1800 RPM see TEM_PTO_Eng_Spd_Disengages 14400 RPM/8

Página 5

Página 8 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
if this Parameter is 1, the PTO will be disengaged if the engine speed is over the value set in
TEM_PTO_Eng_Spd_DisEng_Limit
2112 TEM_PTO_Eng_Spd_Disengages On/Off 1 On/Off
If this Parameter is 1, the PTO will not be engaged if the engine speed is over the value set in
TEM_PTO_Eng_Spd_Engmnt_Limit
2092 TEM_PTO_Eng_Spd_Engmnt_Inhib On/Off 1 On/Off
TEM_PTO_Eng_Spd_Engmnt_
Limit
2093 1000 RPM See TEM_PTO_Eng_Spd_Engmnt_Inhib 8000 RPM/8
TEM_PTO_Ext_Input_Allow_ if this Parameter is 1, the PTO will be reengaged after a disengage due to the designated
ReEng external input when the external input is no longer active
2121 On/Off 0 On/Off
if this Parameter is 1, the PTO will be disengaged if the external input designated for this
purpose is active
2117 TEM_PTO_Ext_Input_Disengages On/Off 0 On/Off
TEM_PTO_Key_State_Allow_ If this parameter is set, the PTO will be allowed to reengage when the key state is returned to
ReEng run.
2069 On/Off 0 On/Off
TEM_PTO_Mast_Swtch_Allow_ if this Parameter is 1, the PTO will be reengaged after a disengage due to the master switch
ReEng being turned off when the master switch is turned on again
2123 On/Off 0 On/Off
TEM_PTO_Mast_Swtch_
Disengages
2118 On/Off if this Parameter is 1, the PTO will be disengaged if the vehicle master switch is not ON 0 On/Off
TEM_PTO_Mast_Swtch_Engmnt_
Inhib
2099 On/Off If this Parameter is 1, the PTO will not be engaged if the vehicle master switch is not ON. 0 On/Off

2089 TEM_PTO_Neut_Engmnt_Inhib On/Off If this Parameter is 1, the PTO will only be engaged if the Transmission is not in Neutral or Park 0 On/Off
if this Parameter is 1, an alarm will sound if the PTO is engaged and transmission is taken out of
neutral
2132 TEM_PTO_Non_Neut_Alarms On/Off 0 On/Off
TEM_PTO_Non_Neut_Allow_ if this Parameter is 1, the PTO will be reengaged after a disengage due to transmission out of
ReEng neutral when the transmission is placed back into neutral.
2148 On/Off 0 On/Off

2109 TEM_PTO_Non_Neut_Disengages On/Off if this Parameter is 1, the PTO will be disengaged if the transmission is taken out of neutral 0 On/Off
TEM_PTO_Non_Neut_Engmnt_
Inhib
2088 On/Off If this Parameter is 1, the PTO will not be engaged if the Transmission is not in Neutral or Park 0 On/Off

2131 TEM_PTO_Pk_Brake_Alarms On/Off if this Parameter is 1, an alarm will sound if the PTO is engaged and the park brake is released 0 On/Off
TEM_PTO_Pk_Brake_Allow_ if this Parameter is 1, the PTO will be reengaged after a disengage due to park brake released
ReEng when the park brake is reapplied.
2149 On/Off 0 On/Off

2108 TEM_PTO_Pk_Brake_Disengages On/Off if this Parameter is 1, the PTO will be disengaged if the Park Brake is released 0 On/Off
TEM_PTO_Pk_Brake_Engmnt_
Inhib
2087 On/Off If this Parameter is 1, the PTO will not be engaged if the Park Brake is not set. 0 On/Off
if this Parameter is 1, the PTO will be reengaged after a disengage due to vehicle overspeed
when the vehicle speed is below TEM_PTO_Veh_Spd_Engmnt_Limit
2119 TEM_PTO_Veh_Spd_Allow_ReEng On/Off 0 On/Off
TEM_PTO_Veh_Spd_DisEng_
Limit
2111 4,828000 kph see TEM_PTO_Veh_Spd_Disengages 1236 kph/256
if this Parameter is 1, the PTO will be disengaged if the vehicle speed is over the value set in
TEM_PTO_Veh_Spd_DisEng_Limit
2110 TEM_PTO_Veh_Spd_Disengages On/Off 0 On/Off
If this Parameter is 1, the PTO will not be engaged if the vehicle speed is over the value set in
TEM_PTO_Veh_Spd_Engmnt_Limit
2090 TEM_PTO_Veh_Spd_Engmnt_Inhib On/Off 1 On/Off

Página 6

Página 9 de 34
Fri Apr 09 13:35:32 COT 2021

Parameters: 3HAWYAHT2HL466658 ESC

Cfg. Value
Cfg.
ID Parameter Value Unit Description Unit
TEM_PTO_Veh_Spd_Engmnt_
Limit
2091 4,828000 kph See TEM_PTO_Veh_Spd_Engmnt_Inhib 1236 kph/256
2432 Usage_Cycle_Coolant_Temp_LT 49 C 89 C+40
2431 Usage_Cycle_Coolant_Temp_UT 71 C 111 C+40
2350 Vehicle_Speed_Alrm_Ty_Param No Alarm No_Units 0 No_Units
610 Vehicle_Speed_Filter_Param 255 No_Units Speedometer update rate. A value of 1 is the slowest and 255 is the fastest update rate. 255 No_Units
255-
00000000000000
2332 Vehicle_Speed_Max_WL kph Maximum Threshold for vehicle speed in-gauge warning light 65535 kph/256
255-
00000000000000
2328 Vehicle_Speed_Min_WL kph 65535 kph/256
1887 Wipers_Hi_Current 15 A Winshield Wipers High Current Detection Level (Amps) 15000 mA
1886 Wipers_Lo_Current 0 A Windshield Wipers Low Current Detection Level (Amps) 0 mA
1888 Wipers_OC_Current 0 A Windshield Wipers Open Circuit Detection Level (Amps) 0 mA

2171 Wipers_To_Low_Int_Enabled On/Off This parameter is used to enable or disable the wiper speed override, if it is present. 1 On/Off
2228 Wipers_To_Low_Int_Timeout 60 s 6000 timercounts
1899 Work_Light_Hi_Current 10 A Work Light High Current Detection Level (Amps) 10000 mA
1898 Work_Light_Lo_Current 0 A Work Light Low Current Detection Level(Amps) 0 mA
1900 Work_Light_OC_Current 0 A Work Light Open Circuit Detection Level (Amps) 0 mA
1- This parameter sets the amount of time that the work light will remain on after the ignition is
0000000000000 turned to off.
640 Work_Light_Timeout_Enable hr 12 min*10

Página 7

Página 10 de 34

You might also like