You are on page 1of 1

SSI SCHAEFER SYSTEM (M) S/B Confidential 4/11/2022

CUSTOMER: AKITEK AKIPRIM SDN BHD


Prepare by: TONY
DATE: 04-Nov-22
Specification: Floor Loading for Pallet Racking System (D220704) Excluding Aisle

1)UDL Load for entire floor (14 BAYS x 2D x 5H)


Total Area (m2) : 33.5 m X 2.4 m = 80.4 M2
= 80.4 M2
1) Total Live Load
Total Pallet (1000 kg/pallet): 1,000 kg X 280 Pallets = 280,000 kgs
Total Live Loading (kg): 280,000 kgs

2) Total Dead Load (kg):


Total Live Loading x 7%(kg): 19,600 kg

4) Grand Total Loading (kg):


Total Live + Total Dead : 299,600 kg

UDL (Uniformly Distribution Load) (kg/M2)


1)Grand Total Loading / Total Area (M2): 3.73 tons/M2 = 36.56 KN/M2 = 37 Kpa

2) POINT Load For 4 Beams level


1) Total Live Load
Total BAY load (base on 1000kg/pallet): 1,000 kg X 8 Pallets = 8,000 kgs
2) Total Dead Load (kg):
Total Live Loading x 7%(kg): 560 kg
3) Grand Total Loading (kg):
Total Live + Total Dead Loading (kg): 8,560 kg
POINT LOAD (per Post)
Grand Total Loading (frame) / 2 (posts): 4.3 tons/post (Base Plate size (180mm x 100mm))
Grand Total Loading (Post) / Base Plate: 2 N/MM2

DISCLAIMER : The above calculation is an estimation of rack loading,


SSI-Schaefer Systems (M) S/B does not guarantee or responsible for any risks of floor issue.
Additionally, Customer is advised to consult a C & S Engineer for further checking and
confirmation on the actual floor slab / foundation design.