You are on page 1of 2

OPTIPETTE pipette series

OPTIPETTE pipette series feature slim handle, high accuracy and precision rates combined with their
tremendous robustness. Its design provides users with excellent ergonomics & safety.

Additional spacers enable


• Ergonomic handle design ejector height adjustment
• Easy calibration
• Excellent accuracy & precision
• Soft spring system reducing
pipetting forces
• Colour-coded rings for volume
identification
• UV resistant body
• Autoclavable lower parts
• Available in 8- &12-channel
version Rotating pipetting
pushbutton prevents
accidental volume change

Calibration key provided


with each pipette allows
user-calibration

5484 5449 5480 5479


Carousel Multiple Plexi Plexi
stand stand 4-position stand 1-position stand

12
Colour Standard tips,
Model Cat. no. code Volume (μL) A (%) P (%) non-filtered

0.2  ± 12.0  ± 6.0


 
OP2* 5601 1.0 ± 2.7 ± 1.3
  Max 2.0 ± 1.5 ± 0.7
10 μL
Min 0.5 ± 4.0 ± 2.8
OP10 5602 5.0 ± 1.0 ± 0.6
Max 10.0 ± 0.5 ± 0.4

OP20 5603
Min 2
10
±
±
±
3.0
1.0
0.8
±
±
1.5
0.5
Art#5.8
Max 20 ± 0.3

Min 5 ± 2.5 ± 2.0


OP50 5607 25 ± 1.0 ± 0.6
Max 50 ± 0.8 ± 0.4

Art#5.7
200 μL
Min 10 ± 1.6 ± 0.80
OP100 5604 50 ± 0.8 ± 0.24
Max 100 ± 0.8 ± 0.20

Art#5.6
Min 20 ± 1.2 ± 0.60
OP200 5605 100 ± 0.8 ± 0.25
Max 200 ± 0.6 ± 0.20

Min 50 ± 1.0 ± 0.4


OP250 5600 125 ± 0.8 ± 0.3 300 μL
Max 250 ± 0.6 ± 0.3

Min 100 ± 1.6 ± 0.40


OP1000 5606 500 ± 0.7 ± 0.20 1,000 μL
Max 1,000 ± 0.6 ± 0.15

Min 500 ± 1.2 ± 0.5


OP5000 5608 2,500 ± 0.6 ± 0.20 5,000 μL
Max 5,000 ± 0.5 ± 0.15

 Min 1,000 ± 2.5 ± 0.6


OP10000 5609 5,000 ± 0.8 ± 0.3 10,000 μL
Max 10,000 ± 0.5 ± 0.2

*OP2 – minimum volume is 0.1 μL.

Colour Standard tips,


Model Cat. no. code Volume (μL) A (%) P (%) non-filtered

Min 0.5  ± 10.0  ± 8.0


OP8-10 5141   5 ± 4.0 ± 2.0 10 μL
OP12-10 5145   Max 10 ± 2.0 ± 1.2

Min 5 ± 4.0 ± 2.5


OP8-50 5142 ± 3.0
25 ± 1.2
OP12-50 5146 ± 1.6
Max 50 ± 0.6
200 μL
Min 20 ± 3.0 ± 1.5
OP8-200 5143 ± 1.5
100 ± 0.8
OP12-200 5147 ± 1.0
Max 200 ± 0.6

Min 50 ± 1.6 ± 1.5


OP8-300 5144 150 ± 1.2 ± 1.0 300 μL
OP12-300 5148 Max 300 ± 1.0 ± 0.6
Note: The HTL maximum permissible errors are guaranteed only when HTL pipette tips are used.

Product Cat. no. Model Accessories

OPTIPETTE 7902 OP10 Plexi 4-position stand


STARTER 4 PACK OP20 Tips 10 μL, 96 pcs
OP200 Tips 200 μL, 96 pcs
OP1000 Tips 1,000 μL, 96 pcs
Calibration tool x 4
Instruction manual

OPTIPETTE COLOR 7912 OP10 Plexi 4-position stand


STARTER 4 PACK OP20 Tips 10 μL, 96 pcs
OP200 Tips 200 μL, 96 pcs
OP1000 Tips 1,000 μL, 96 pcs
Calibration tool x 4
Instruction manual

13