A B C A B C A B C CITY ENGINEER'S OFFICE

OFFICE OF THE BLDG. OFFICIAL


CONSTRUCTION NOTES
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS
OTHERWISE SHOWN OR NOTED, MODIFY TYPICAL DETAILS AS DIRECTED.
1
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON, PRE-CAST
CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL BEFORE FABRICATION.
F1/C1 F1/C1 F1/C1
1 C1 B1 (200x400) C1 B2(200x400) C1
1 B1 (200x400) B2(200x400)

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK WITH MECHANICAL AND ELECTRICAL

B11(200x400)

B13(200x400)
B12(200x400)
B11(200x400)

B13(200x400)
B12(200x400)
CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE.

4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORINGS AND BRACINGS OF THE STRUCTURE FOR
S1 S1 S1 S1 DATE
ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION.
LAND USE & PLANNING
B. CONCRETE & REINFORCEMENT 2
1. ALL MATERIALS & WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING CODE OF AMERICAN CONCRETE INSTITUTE
F1/C1 F1/C1 F1/C1
2 C1 B3(200x400) PC1 B4(200x400) C1
2 B3(200x400) B4(200x400)
(ACI-318).

B15(200x400)

B16(200x400)
B15(200x400)

B14(200x400)
B16(200x400)
B14(200x400)
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS WITH
CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUPMS AS FOLLOWS:
S1 S1 S1 S1
LOCATION 28 DAYS STRENGTH MAX. SIZE AGG. MAX. SLUMP

3000 PSI (20.68 Mpa)


3
3. ALL REINFORCEMENT BARS SHALL CONFORM TO ASTM A615 (PNS 49) GRADE 33 FOR DIA. 12 AND SMALLER BARS & GRADE 40
FOR DIA. 16 AND LARGER BARS. COLUMN HOOPS ARE ALL GRADE 33 BARS.
F1/C1
F1/C1 F1/C1
3 C1 B5(200x400) C1 B6(200x400) C1
3 B5(200x400) B6(200x400)
S2 CS1
4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING REINFORCED CONCRETE LINE & GRADE

B18(200x400)
B18(200x400)

B17(200x400)
B17(200x400)
STRUCTURES SHALL BE ADHERED TO, UNLESS OTHERWISE SHOWN OR NOTED. B7(200x400)
S2 S1 S1
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS:

SLAB ON GRADE -----------------------------------------1 1/2 IN. (38 MM.) 4 CF1/C3


B8(200x400)
S2
WALLS ABOVE GRADE----------------------------------1 IN. (25 MM.)
COLUMN TIES-----------------------------------------------1 1/2 IN. (38 MM.)
F1/C1 F1/C1
4 4
WHERE CONCRETE IS EXPOSED -------------------2 IN. (50 MM.)
TO EARTH BUT POURED AGAINST FORM
4' B9(200x400) C1 B10(200x400) C1 B10(200x400)
CS1

DIRECTLY AGAINST EARTH ---------------------------3 IN. (75 MM.)S


WHERE CONCRETE IS DEPOSITED
F2/C2 F2/C2 F2/C2 4' C2 C2 C2
4'
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1 (TABLE OF LAP
SPLICE AND ANCHORAGE LENGTH)
FOUNDATION PLAN UGF FRAMING PLAN ROOF DECK FRAMING PLAN
UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.

7. ALL ANCHOR BOLTS, DOWELS. AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED AND SECURED IN PLACE PRIOR TO
PLACING OF CONCRETE.
ARCHITECTURAL
8. CONTRACTORS SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENTS AND MECHANICAL BASES
THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.

9.ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE
USE OF WET BURLAP, FOR SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS.

10. STRIPPING OF FORMS AND SHORES.

FOUNDATION----------------------------------------------------24 HRS
WALLS-------------------------------------------------------------18 HRS

C. FOUNDATION
1. FOUNDATION WAS DESIGNED USING AN ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 95.7 KPA.

2. FOUNDATION SHALL REST ON NATURAL SOIL, UNLESS OTHERWISE NOTED BY THE ENGINEER, NO PART OF THE FOUNDATION STRUCTURAL
SHALL REST ON FILL.

3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION HAVE BEEN COMPLETED AND PRIOR TO
CONCRETING TO CONFIRM THE DESIGN SOIL BEARING CAPACITY.

4. THE CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING AND SHORING NECESSARY
TO SAFELY RETAIN EXCAVATION AND EARTH BANKS.

5. ALL ON-SITE WORKS SHALL BE AS PER RECOMMENDATION OF THE PROJECT SOIL ENGINEER.

6. PILING, IF ANY, SHALL BE CONDUCTED WITH MINIMUM DISTURBANCE TO ADJACENT PROPERTIES.

NOTES ON MASONRY AND CONCRETE BLOCKS


1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF, FOR LOAD BEARING
TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGTH OF 6.9 MPA. (1000 PSI) SHALL BE DEVELOPED. ELECTRICAL
2. PROVIDE 1-16MM DIA. EXTRA VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS, AND EACH SIDE OF OPENINGS AS
SHOWN.

3. LINTEL BEAMS OR LINTEL BLOCKS SHALL BEAR AT LEAST 8 INCHES (200MM) ON EACH SIDE OF MASONRY WALL OPENING.

4. WALL REINFORCEMENTS SHALL BE AS FOLLOWS:

WALL THICKNESS VERTICAL REIN. HORIZONTAL REIN.

8 IN (200 MM)
6 IN (150 MM)
4 IN (100 MM)
12MM DIA. @ 400MM O.C.
12MM DIA. @ 400MM O.C.
12MM DIA. @ 400MM O.C.
10MM DIA. @ 600MM O.C.
10MM DIA. @ 600MM O.C.
10MM DIA. @ 600MM O.C.
FOOTING DETAIL COLUMN DETAIL BEAM DETAIL DETAILS OF STAIRS
5. BLOCK WALL REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BAR DIAMETERS WHERE SPLICED, HORIZONTAL/VERTICAL
DOWELS FROM FOOTINGS, COLUMNS/WALLS OR SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 30 BAR DIAMETERS
OR A MINIMUM OF 400 MM. WHICHEVER IS LONGER AND DOWELS TO MATCH VERTICAL REINFORCEMENTS OF WALL. MECHANICAL
6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT. (REFER TO
SPECIFICATIONS)

CONSTRUCTION NOTES NOTES:

LAP SPLICE 1. ACI SECTION 12.4 STATES THAT


MIN. LAP SPLICE DEVELOPMENT LENGTH OF
(M)
STANDARD HOOK LENGTH OF COL. INDIVIDUAL BARS W/ IN A BUNDLE,
BAR ANCHO (M) REIN. INDIVIDUAL IN TENSION OR COMPRESSION,
UNIT
DIA. RAGE TENSION BAR COMP. BAR BARS SHALL BE THAT FOR THE
(MM) LENGTH
WT.
INDIVIDUAL BAR, INCREASED 20% SANITARY
(KG/M)
(MM) FOR THREE BAR BUNDLE, AND
180 135 TOP BOT. TOP BOT. W/ TIES W/ SPIRAL
90 DEG 33% FOR FOUR BAR BUNDLE.
DEG DEG BAR BAR BAR BAR

2. FOR COLUMNS, AT ANY LEVEL


10 0.60 0.15 0.13 0.10 0.42 0.30 0.42 0.30 0.617 0.30 0.30 NO MORE THAN ALTERNATE
BARS SHOULD BE SPLICED. NOT
MORE THAN 33% OF THE BARS
12 0.60 0.20 0.15 0.12 0.42 0.30 0.42 0.30 .888 0.30 0.30 SHALL BE SPLICED W/IN THE
REQUIRED LAP LENGTH. MINIMUM
DISTANCE BETWEEN TWO
16 0.60 0.25 0.18 0.14 0.73 0.52 0.87 0.62 1.580 0.52 0.47 ADJACENT BAR SPLICES SHALL
BE 600 MM.

20 0.60 0.30 0.20 0.20 0.91 0.65 1.10 0.78 2.469 0.65 0.58 3. TOP BARS ARE HORIZONTAL
BARS W/ MORE THAN 300MM
DEPTH OF CONCRETE CAST
25 0.68 0.40 0.28 0.26 1.15 0.82 1.40 1.00 3.858 0.80 0.73 BELOW THE REINFORCEMENT. FIRE DEPARTMENT
4. AS MUCH AS POSSIBLE,
28 0.86 0.48 0.38 1.45 1.03 1.53 1.09 4.840 0.90 0.82 SPLICES SUBJECTED TO TENSILE
STRESSES ARE DISCOURAGE,
THESE SHOULD BE AVOIDED OR
32 1.12 0.56 0.43 1.90 1.35 1.74 1.24 6.327 1.03 0.93 PROVIDED W/ STANDARD HOOKS.

36 1.43 0.61 0.48 2.40 1.70 2.0 1.40 8.000 1.20 1.05

DOOR OPENING ELEVATION CHB PLAN WALL FOOTING DETAIL 1 WALL FOOTING DETAIL 1

PREPARED BY: SEAL PRC ID: TITLE & LOCATION: OWNER: SHEET NO.:
TIN NO.:
GENEVIEVE G. GAYOSO
CIVIL ENGINEER
PTR NO.:
DATE:
PROPOSED MARY JANE P. LASTRA RES. BLDG.
SANTA MARIA, BULACAN
MARY JANE PETILO-LASTRA
S1 2