INPUT

F'c (kg/cm2) 200 f'c (psi) 2846.6


Fy (kg/cm2) 4200
DL (T/m) 15.85
LL(T/m) 2.63
qall (T/m2) 40 qeff 40
Df (m) 0
Wall thickness (th) 0.2 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 18.48 T/m
L = P/qeff 0.462 m
L 1m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 26.661 notes
qu = Pu/ ( L x B) 26.661 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 10.6644
1.2sqrtf'c +qu 90.38686
d (from Vc = Vn) 0.117986 m

D (rounded up to nearest 5 cm 30 cm
H = D + 10cm 40 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 2.13288 T-m/m
As= Mu/F bd2 2.63319 cm2/m length
or Mu=FAsFy0.95d 1.97984 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 14 mm
Ab 1.5386 cm2
Spacing = 100Ab/As 15.5414 cm <=
User Chosen spacing 15 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 7.2


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 15.7 <=
Number of bars in width 15

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 14 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 6.07143
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 37.65 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

9.9 cm2/m length


200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

32.5 [(L - th)/ 2] - cover 7.5 cm


INPUT
F'c (kg/cm2) 200 f'c (psi) 2846.6
Fy (kg/cm2) 4200
DL (T/m) 21
LL(T/m) 6
qall (T/m2) 35 qeff 33.8
Df (m) 0.6
Wall thickness (th) 0.25 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 27 T/m
L = P/qeff 0.79882 m
L 1m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 39.6 notes
qu = Pu/ ( L x B) 39.6 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 14.85
1.2sqrtf'c +qu 103.3259
d (from Vc = Vn) 0.14372 m

D (rounded up to nearest 5 cm 35 cm
H = D + 10cm 45 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 2.78438 T-m/m
As= Mu/F bd2 2.52551 cm2/m length
or Mu=FAsFy0.95d 2.21536 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 9.78701 cm <=
User Chosen spacing 12.5 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 8.1


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 13.9556 <=
Number of bars in width 15

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 14 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 6.07143
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 37.65 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

11.55 cm2/m length


225 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

225 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

30 [(L - th)/ 2] - cover 7.5 cm


INPUT
F'c (kg/cm2) 200 f'c (psi) 2846.6
Fy (kg/cm2) 4200
DL (T/m) 19
LL(T/m) 4.5
qall (T/m2) 25 qeff 23.8
Df (m) 0.6
Wall thickness (th) 0.2 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 55 T/m
L = P/qeff 2.31092 m
L 1m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 80.3 notes
qu = Pu/ ( L x B) 80.3 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 17.84444
1.2sqrtf'c +qu 108.337
d (from Vc = Vn) 0.164712 m

D (rounded up to nearest 5 cm 20 cm
H = D + 10cm 30 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 3.56889 T-m/m
As= Mu/F bd2 9.91358 cm2/m length
or Mu=FAsFy0.95d 4.96921 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 11.4025 cm <=
User Chosen spacing 20 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 5.4


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 20.9333 <=
Number of bars in width 4.77707

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 12 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 7.08333
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 32.27 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

6.6 cm2/m length


150 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

150 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

32.5 [(L - th)/ 2] - cover 7.5 cm


INPUT
F'c (kg/cm2) 200 f'c (psi) 2846.6
Fy (kg/cm2) 4200
DL (T/m) 44
LL(T/m) 11
qall (T/m2) 35 qeff 33.8
Df (m) 0.6
Wall thickness (th) 0.2 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 55 T/m
L = P/qeff 1.62722 m
L 1.8 m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 80.3 notes
qu = Pu/ ( L x B) 44.61111 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 35.68889
1.2sqrtf'c +qu 108.337
d (from Vc = Vn) 0.329425 m

D (rounded up to nearest 5 cm 35 cm
H = D + 10cm 45 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 14.2756 T-m/m
As= Mu/F bd2 12.9483 cm2/m length
or Mu=FAsFy0.95d 11.3582 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 14 mm
Ab 1.5386 cm2
Spacing = 100Ab/As 11.8826 cm <=
User Chosen spacing 10 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 8.1


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 13.9556 <=
Number of bars in width 12.89809

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 14 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 6.07143
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 37.65 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

11.55 cm2/m length


225 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

225 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

72.5 [(L - th)/ 2] - cover 7.5 cm


INPUT
F'c (kg/cm2) 200 f'c (psi) 2846.6
Fy (kg/cm2) 4200
DL (T/m) 13
LL(T/m) 4
qall (T/m2) 25 qeff 23.8
Df (m) 0.6
Wall thickness (th) 0.25 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 55 T/m
L = P/qeff 2.31092 m
L 1m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 80.3 notes
qu = Pu/ ( L x B) 80.3 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 16.72917
1.2sqrtf'c +qu 108.337
d (from Vc = Vn) 0.154418 m

D (rounded up to nearest 5 cm 30 cm
H = D + 10cm 40 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 3.13672 T-m/m
As= Mu/F bd2 3.87249 cm2/m length
or Mu=FAsFy0.95d 2.91165 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 14 mm
Ab 1.5386 cm2
Spacing = 100Ab/As 15.5414 cm <=
User Chosen spacing 15 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 7.2


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 15.7 <=
Number of bars in width 6.369427

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 14 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 6.07143
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 37.65 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

9.9 cm2/m length


200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

30 [(L - th)/ 2] - cover 7.5 cm


INPUT
F'c (kg/cm2) 200 f'c (psi) 2846.6
Fy (kg/cm2) 4200
DL (T/m) 29
LL(T/m) 8.5
qall (T/m2) 25 qeff 23.8
Df (m) 0.6
Wall thickness (th) 0.25 m

STEP 1: FOOTING WIDTH (L) USING SERVICE LOAD


P = DL + LL 55 T/m
L = P/qeff 2.31092 m
L 1.6 m Chosen by user

STEP 2: FOOTING DEPTH FOR 1-WAY SHEAR


Pu = 1.4 DL + 1.7 LL 80.3 notes
qu = Pu/ ( L x B) 50.1875 with B=1m (Design is per
Vu = qu x [((L-th)/2) - d) Vu @d-away
Vn = Vu/F F = 0.85
Vc = [2sqrt(f'c in psi) x 10 x b x d] / 14.233
d = [qu*L/2]/ [1.2 *√f'c(psi) + qu] from Vc = Vn
qu * L/2 30.1125
1.2sqrtf'c +qu 108.337
d (from Vc = Vn) 0.277952 m

D (rounded up to nearest 5 cm 30 cm
H = D + 10cm 40 cm

STEP 3: FOOTING DESIGN FOR FLEXURE

STEP 3.1: Determine As (cm2/m)


Mu@face = qu * L * L/2 10.163 T-m/m
As= Mu/F bd2 12.5469 cm2/m length
or Mu=FAsFy0.95d 9.43374 cm2/m length Asmin
STEP 3.2: SPACING OF BARS Main Steel
Bar diameter 14 mm
Ab 1.5386 cm2
Spacing = 100Ab/As 12.2628 cm <=
User Chosen spacing 15 cm

STEP 3.3: LONGITUDINAL REINFORCEMENT

Asmin = 0.0018 x B x H 7.2


Bar diameter 12 mm
Ab 1.1304 cm2
Spacing = 100Ab/As 15.7 <=
Number of bars in width 10.19108

STEP 4: CHECK ANCHORAGE

ld/db = 3/40 fy/√f'c abgl/ [c +Ktr]/db (ACI 12.2.3)

Bar diameter 14 mm
a (location factor 1.3 for top cast, 1
for bot) 1 ab
b (coating factor: 1.5 if epoxy coated
and cover < 3db or clear spacing<
6db; 1.2 for all other epoxy coated; 1
for uncoated 1
g (Reinforcement size factor: 0.8 if <=
No.6 [T20]; 1 if >= No.7 [T22]) 0.8
l (1.3 for lightweight aggregate
concrete else 1) 1
Distance from center of bar to nearest
concrete surface (cm) 8.5
One-Half center to center bar spacing
(cm) 9
C = min of above (cm) 8.5
c/db <= 2.5 6.07143
Ktr = 0 for footings (cz no stirrups) 0

ld/db 26.89
Ld = 37.65 cm <=
Ld min = 30.5 cm
E LOAD

Chosen by user

with B=1m (Design is per m length for walls)


Vu @d-away

from Vc = Vn

Dmin 15cm

9.9 cm2/m length


200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

200 (5 x H) cm and <= 45 cm (18in) ACI 7.12.2.2

BARS IN TENSION

1 <= 1.7

60 [(L - th)/ 2] - cover 7.5 cm