You are on page 1of 281

Code:YETS-0017-C

Commissioning Manual
Product type : MPDK136

Related load:≤1600kg

Related speed:≤2.5m/s

SHENYANG YUANDA INTELLECTUAL INDUSTRY GROUP CO., LTD.


MPDK136 Commissioning Manual Code:YETS-0017-C

Content
1- Preface
2- Attentions
3- Check and confirmation before operation
4- Power-on and inspection
5- Emergency electro motion/ Inspection running
6- Door operator debugging (refer to mated door operator debugging manual)
7- Self-learning running
8- Debugging operation
9- Function confirmation
10- Elevator in parallel commissioning
11- Pre-opening and releveling function commissioning
12- Weighing device commissioning
13- Fault instruction
14- Group control system commissioning instruction
15- Opposite door elevator commissioning instruction
16- Voice announcement control panel setting instruction
17- Display panel setting
18- BLT12 interphone commissioning instruction
19- Operation manual for IC card control system
20- Instructions for Internet of Things
21-Door operator commissioning instruction
23- Community monitoring instruction
24- Car sterilization function debugging
25- Instructions for BLT Internet of Things
26-F07.04 version applications upgrading additional function parameters and commissioning method
ⓚ Z16-0129

-1-
MPDK136 commissioning manual Code:YETS-0017-C

1-Preface
The manual is only provided to the debugging and maintenance personnel of BLT
Elevator Company after the qualified training. In order to keep safety for your own and
others, please don’t carry out any processing step without qualification and authorization.
Shenyang BLT Elevator Co., Ltd. reserves the right for all pictures and information
within the manual, being forbidden to directly and indirectly publish as well as hurt the
BLT’s benefits. The manual is prohibited copying for any reason. In case of debugging
personnel’s leaving the company, the profiles should be returned to BLT in time.
The debugging personnel should carefully read the manual in advance and strictly
implement the operation according to the procedures in the manual as well. During the
debugging process, the debugging personnel should wear insulated shoes and work cloths
special for electrician. At least one suit of debugging tools should be kept at each site.
This manual adopts MPDK136 control system for the electric debugging of passenger
elevator, and it is suitable for the elevator system of mating test work when the control cabinet,
traction machine and encoder are delivered. This manual needs assorting the following Electric
Installation Manual.
It makes all the difference for elevator safety, so that each debugging personnel
should be rather careful, never letting any doubtful point pass or carrying through the
dangerous operation.
Please notify any problems on the manual to the BLT Electrical Department.

1-1
MPDK136 commissioning manual Code:YETS-0017-C

2-Attentions
1. Check the well correspondingly and ensure the installation of elevator components and no barrier
within the well before the commissioning.
2. No water in the pit and no-leakage on well enclosure before the commissioning.
3. Before the commissioning, check the temperature and humidity of machine room to meet the demand,
ensure no ponding and no leakage on the ground.
4. Before the commissioning, check if the overall arrangement of machine room is reasonable and if the
lighting switch is available when passengers enter the gate.
5. Check each apparatus in the control cabinet as well as the wires connection before the commissioning.
6. Check each connector assembly and cable connection carefully without any looseness before the
commissioning.
7. Lay a remarkable sign at the entrance of each hall before the commissioning, in case the outsiders go
into the elevator mistakely.
8. Non-adjustor is forbidden to enter the machine room. The key should be kept by specially-assigned
person after the normal operation.
9. If electricity power is required to be switched off during the process of commissioning, an obvious
sign for No-Switch-In shall be hung or stuck at the switch in order to avoid an accident.
10. All instructions assigned by the primary adjustor during the process shall be repeated and carried out
after rechecking in order to avoid mistakes.
11. For long time working in the well during the process of commissioning, the hole in the floor of
machine room should be covered, avoiding accident caused by drops.
12. Safety helmet should be worn before entering the well during the process of commissioning.
13. Any person is forbidden to enter the pit or climb up to car top privately during the process of
commissioning.
14. Car top adjustor is forbidden to lean upon the guard or one foot on car top and the other on any
fixture in the well.
15. Car top adjustor is forbidden to expand any part of body out of the car, avoiding the crush injury.
16. Car top adjustor should pay attention to the relative distance between the counterweight and car top
at any moment.
17. Pit adjustor should pay attention to the dropping location of counterweight at any moment.
18. Pit adjustor is absolutely forbidden to remain just below the counterweight.
19. It is absolutely forbidden to operate the switch of trap door, safety gear and inner lock after shorting
of mechanical and electrical system during the process of commissioning.

2-1
MPDK136 commissioning manual Code:YETS-0017-C

20. In case of pit in excess of 1.5m, it needs to climb up and down by ladder or staircase, forbidding
people to climb by catching traveling cable, car platform or the other part.
21. Check the quality of the cable and make sure the insulation protective film is in good condition
while using portable lamp during the process of commissioning.
22. It is forbidden to alter the circuit without permission during the process of commissioning. It should
be reported for approval and kept in the archives if necessary.
23. When the commissioning is not completed and the worker needs withdrawing temporarily, all the
landing doors should be closed, the doors that can’t be closed should be blocked and equipped with
the remarkable sign showing danger.
24. When the commissioning is not finished and the working personnel needs withdrawing temporarily,
the main switch should be switched off, the machine room should be locked.
25. Cut off all heat sources including blowtorch, strong light and soldering copper as the adjustor
momentarily leaves the site.
26. During the process of commissioning, tools and scrap wires shall not be left all around, and taken
away after the collection.
27. In case of accident or emergency stop, firstly release the trapped person and then carry out the
maintenance service.
28. After finishing the commissioning, reset all switches to normal status and remove all the billboards.
29. After finishing the commissioning, clean up the working site carefully, scrap wires are forbidden to
be left around control cabinet, service kit and all switches.
30. After finishing the commissioning, reconfirm the elevator’s normal operation, the quantity of
shorting connector assembly on elevator protective isolation device and its location.
31. According to the requirements, the adjustment shall not be cut for saving time.
32. After the normal operation, record should be filled in carefully, so as to do the hand-over works with
drivers or the related personnel.

2-2
MPDK136 commissioning manual Code:YETS-0017-C

3-Check and Confirmation Before Operation

WARNING
Before check, confirm the main power of elevator and the lighting has been off state.
Cut off the corresponding air switch in control cabinet of elevator.

3.1. Check and Confirmation of machinery assembly at site;


(1) Complete installation of elevator pit parts; confirm the enough buffer oil according to
requirement as using hydraulic buffer; dry condition in pit;
(2) There is no barrier which influences the regular operation of elevator in the well.
(3) Favorable installation of landing door;
(4) Good sealing between upright and door opening of landing door;
(5) The installation of guide rail passed test.
(6) Correct installation of wire rope, being fixed.
(7) Fixed installation of limit switch, final limit switch;
(8) Correct installation of rope tension sheave of speed governor;
(9) Correct installation of car, car door and door vane, being assembled fixedly;
(10) Favorable fixation of traveling cable;
(11) Location of machine room component accords with national standards;
(12) Fixation of host machine accords with the factory installation requirement of the factory,
and the main part of traction machine is fixed and sealed according to the standard
(including hidden projects);
(13) As for geared traction machine, the reduction box should be oiled according to the
requirements;
(14) Confirm the fixation of encoder on traction machine;
(15) The positioning of speed governor accords with the national standards;
(16) The wire casing should be laid down regularly and neatly. Its laying should meet the
demand of the installation of the wire duct. The yellow-green earth wire is connected
with wire duct;
3-1
MPDK136 commissioning manual Code:YETS-0017-C

(17) Control cabinet is installed properly according to the requirement of control cabinet
installation;
(18) Keep clean in well and machine room;
(19) All installations accord with national installation specification.
3.2. Check and Confirmation of electrical assembly

WARNING
During the following process of check, any problem happened
should be checked and solved carefully, confirming no influence
on equipment and people!

(1) Check the following wiring in accordance with the drawing


A. L1, L2 and L3 three phase supply wires from elevator’s main power box to control cabinet;
B. Wire from the brake coil of traction machine through brake cable to the connector assembly
in control cabinet;
C. Wire from U, V and W in control cabinet to three phase supply wires in motor of traction
machine;
D. Wire from encoder of traction machine, inverter of control cabinet and main controller;
E. Access of safety circuit;
F. Access of door lock circuit;
G. Connection wires on car top;
H. On & off logic of inspection circuit and test circuit;
I. Power supply of door operator and signal connection
(2) Earthing check
A. Check power wires: Make the open-circuit between AC power source and DC power
source, power supply and PE. For the inspection of output terminal of transformer, please
3-2
MPDK136 commissioning manual Code:YETS-0017-C

measure after disconnecting the lead from transformer terminal.


B. Measure the resistance between communication cable CAN+、CAN-、MOD+、MOD- and PE
(ground connection), and confirm that this resistance is infinite.
C. Measure the resistance of all terminals and PE (wiring terminal, PE for short) which are near
infinite.
Including:
a. Between three phase power supply and PE
b. Between three phase of motor U, V, W and PE
c. Between signal terminals and power terminals on inverter and brake unit and PE
d. Between middle connecting terminals in safety circuit and door locks circuit and PE.
e. Inspect and ensure that the resistance between system OV and PE approaches infinity.
During the process of inspection if fewness of resistance value is observed, please check it
immediately and find out fault, the commission can be continued after recovering.

D. The following inspection requires all terminals position and PE to be measured(resistance

value connecting with ground shall be as low as possible)(0~4Ω)

a. Between ground point of motor and PE


b. Between ground point of inverter and PE
c. Between ground point of brake and PE
d. Between ground point of controlling cabinet wall and PE
e. Between the least significant end of wire duct and PE;
f. Between speed governor and PE
g. Between car and PE
h. Between ground point of landing door and PE
i. From ground point of safety switch to PE in shaft pit.
Remark: Before adjustment, please ensure ground connection of power provided by
building site and conforms to national standard.

(3)Inspection of encoder assembly

a. Inspect the fixation of encoder, axes of encoder and extension axis of traction machine shall
3-3
MPDK136 commissioning manual Code:YETS-0017-C

be well fixed.
b. Encoder connection is required to be inducted from encoder to control cabinet.
c. The encoder line is leased circuit provided by BLT, and the self-made line shall not be used on
site.
d. Good fastening of back-end cover followed encoder can make cable shielded layer and
encoder shell contact well and reduce the disturbance.
e. The engineer on site should check that the tightening of encoder is good and avoid the
slackening of encoder resulted from the shake during the transportation.
f. In order to reduce the electromagnetic disturbance, the wiring of encoder should have its own
separate cable duct.
g. When the encoder cable is too long, it should be folded in half and enlaced and not in ring

form. Refer to Installation manual, “Paving requirements of encoder and power line” as shown

in the following picture.

Note: if the sealing wire of encoder is needed checking,


the power should be firstly cut off.

(4)Check connecting terminal of main controller

3-4
MPDK136 commissioning manual Code:YETS-0017-C

a. Confirm the connection of the 24VDC power line, wire number is (24V, 0V).

b. Confirm the landing/ car door, safety circuit 110VAC detect connecting terminal, wire

number is(119, 513, U4, 519).

c. Check each connection terminal and wiring on controlling cabinet, which may be loosened
during the process of transport, so as to the connection position.

3-5
MPDK136 commissioning manual code:YETS-0017-C

4-Power-On and Inspection


4.1 After the examination and confirmation in Part III carry out the following steps:
(1) Take the connector assembly of the brake cable away.
(2) Confirm all air switches in the off state.
(3) Confirm no people within the well and car, being suitable to the conditions for elevator’s
safety operation;
(4) confirm that the construction outside the well has no influence on elevator’s safety
operation;
(5) Set the emergency stop button on control cabinet.
4.2 Examine the main input voltage of TN-S which is provided by site.
Measure the main input voltage at the leading end of 1QF1 power control box, keeping
230±7%VAC and deviation not over 15VAC. Via main transformer’s voltage regulating so
that the relevant voltage is 380±7%VAC.(Different areas have different voltage, 3AC380V is
standard here)
4.3 After the confirmation of regular operation on above examination items, carry out
power-on adjustment.
4.4 Examination after power up:
(1) Close the main power switch 1QF1, and then examine the voltage of enter-wire terminal
among L1, L2 and L3, in accordance with main input voltage.
(2) Examine the power supply of transformer 1TC1 in control cabinet and measure the voltage
as below:
Control transformer 1TC2:

Input (wire marking: 102, 110): 380±7%VAC;

Output (wire marking: 114,115): 220±7%VAC


Output (wire marking: 128,129): 110±7%VAC
For any problems, please check the failure immediately!
(3) As under normal operation, examine the output voltage of transformer and regulated power
supply, the voltage as below:

4 -1
MPDK136 commissioning manual code:YETS-0017-C

Regulated power supply G2:

Input (wire marking: 114, 115): 220±7%VAC;

Output (wire marking: 24V, 0V): 24VDC±0.5VDC;

Output (wire marking: 307, 305): 110VDC±10%,after starting for three

seconds,down to 60VDC±0.5VDC ;

4.5 Display of the main controller and menu setting:


4.5.1 Use of keypad
The onboard keypad consists of three 7-segment LEDs and three buttons. You can view
information about the controller and enter simple commands on the keypad.
Note:
The keypad is exposed, and pay attentions to the following points during use:
1. Wear insulated gloves when performing operations on the keypad to prevent electric shock
or damage to the controller components due to electrostatic discharge.
2. Do not use a metal or sharp tool to press the button to prevent the short-circuit fault or
damage to the components on the MCB.

The following figure shows the appearance of the keypad.

Appearance of the keypad

As shown in the preceding figure, the three buttons are PRG, UP, and SET. The functions of
the three buttons are as follows:
• PRG: Press this button in any state to display the current function group number. You can
press the UP button to change the function group number.
UP: Press this button to increase the function group number.
Currently, the MCB defines a total of 13 function code groups, namely, F0
to F9, and FA to FC. You can press the UP button to display them in turn. In addition, in
special function code group menu, you can input simple references by using the UP button.

4 -2
MPDK136 commissioning manual code:YETS-0017-C

• SET: In the function code group menu, press this button to enter the
menu of the function code group.

In special function code group menu, after you input a simple reference and press this button to
save the setting, the display will return to the F0 menu by default.
The following figure shows the setting of increasing the called floor to 5.

Call setting process


The function code groups displayed on the keypad are described as follows:

1. F0: display of floor and running direction

The F0 menu is displayed on the keypad by default upon power-on. The first 7-segment LED
indicates the running direction, while the last two 7-segment LEDs indicate the current floor
number of the elevator.

When the elevator stops, the first 7-segment LED has no display. When
the elevator runs, the first 7-segment LED blinks to indicate the running direction.
When a system fault occurs, the 7-segment LEDs automatically display the fault code
and blink. If the fault is reset automatically, the F0 menu is displayed.

F1: command input of the running floor

After you enter the F1 menu, the 7-segment LEDs display the bottom floor (F6-01). You can
press the UP button to set the destination floor within the range of lowest to top and then press
the SET button to save the setting. The elevator runs to the destination floor, and the display
automatically switches over to the F0 menu at the same time.

4 -3
MPDK136 commissioning manual code:YETS-0017-C

F2: fault reset and fault code display


After you enter the F2 menu, the 7-segment LEDs display "0". You can
press the UP button to change the setting to 1 or 2.
‫ ־‬Display "1": If you select this value and press the SET button, the system fault is reset.
Then, the display automatically switches over to the F0 menu.
‫ ־‬Display "2": If you select this value and press the SET button, the
7-segment LEDs display the 11 fault codes and occurrence time circularly. You can press
the PRG button to exit.

F3: time display

After you enter the F3 menu, the 7-segment LEDs display the current system time circularly.

F4: Reserved

The parameter is reserved for standby

F5: running times display

After you enter the F5 menu, the 7-segment LEDs display the elevator running times
circularly.

F6: door open/close control


After you enter the F6 menu, the 7-segment LEDs display "1-1", and the UP and SET
buttons respectively stand for the door open button and door close button. You can press
the PRG button to exit.

F7: shaft auto-tuning command input


After you enter the F7 menu, the 7-segment LEDs display "0". You can
select 0 or 1 here, where "1" indicates the shaft auto-tuning command available.

After you select "1" and press the SET button, shaft auto-tuning is implemented if the
conditions are met. Meanwhile, the display switches over to the F0 menu. After shaft
auto-tuning is complete, F7 is back to "0" automatically. If shaft auto-tuning conditions are
not met, fault code "Err35" is displayed.

4 -4
MPDK136 commissioning manual code:YETS-0017-C

F8: test function


After you enter the F8 menu, the 7-segment LEDs display "0". The setting range of F8 is
1–4, described as follows:
‫ ־‬1: Hall call forbidden
‫ ־‬2: Door open forbidden
‫ ־‬3: Overload forbidden
‫ ־‬4: Limit switches disabled
After the setting is complete, press the SET button. Then the 7-segment LEDs display
"Err88" and blink, prompting that the elevator is being tested. When you press PRG to
exit, F8 is back to 0 automatically.

F9: reserved
FA: auto-tuning

After you enter the FA menu, the 7-segment LEDs display "0". The setting range of FA is
1 and 2, as follows:

‫ ־‬1: With-load auto-tuning

‫ ־‬2: No-load auto-tuning

After the setting is complete, press the SET button. Then the 7-segment LEDs display
"TUNE", and the elevator enters the auto-tuning state. After confirming that the elevator
meets the safe running conditions, press the SET button again to start auto-tuning.
After auto-tuning is complete, the 7-segment LEDs display the current angle for 2s, and
then switch over to the F0 menu.

You can press the PRG button to exit the auto-tuning state.

Fb: CTB state display

After you enter the Fb menu, the 7-segment LEDs display the input/output state of the
CTB. The following table describes the meaning of each segment of the LEDs.

Input/Output state of the CTB

4 -5
MPDK136 commissioning manual code:YETS-0017-C

4.5.2 Use of LED operation panel

The LED operation panel is connected to the RJ45 interface of the controller by using an
8-core flat cable. You can modify the parameters, monitor the working
status and start or stop the controller by operating the operation panel. The
following figure shows the LED operation panel.

Figure 4-3 Diagram of the LED operation panel

4 -6
MPDK136 commissioning manual code:YETS-0017-C

LED Operation Panel

Description of Indicators

■ RUN

ON indicates that the controller is in the running state, and OFF indicates that the controller
is in the stop state.

■ LOCAL/REMOT

Reserved.

■ FWD/REV

ON indicates up direction of the elevator, and OFF indicates down direction of the elevator.

■ TUNE/TC

ON indicates the auto-tuning state.

■ Unit Indicators
4 -7
MPDK136 commissioning manual code:YETS-0017-C

means that the indicator is ON, and means that the indicator is OFF.

unit of frequency

unit of current

unit of voltage

unit of rotational speed

percentage

Description of Keys on the Operation Panel

4 -8
MPDK136 commissioning manual code:YETS-0017-C

Operation Procedure

The LED operation panel adopts three-level menu.

The three-level menu consists of function code group (Level I), function code (Level II), and
function code setting value (level III), as shown in the following figure.

Operation procedure on the operation panel

4 -9
MPDK136 commissioning manual code:YETS-0017-C

Shift between three levels of menus

In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot

4 -10
MPDK136 commissioning manual code:YETS-0017-C

be modified. This may be because:


• Such a parameter is only readable, such as actually detected parameters and running record
parameters.

• Such a parameter cannot be modified in the running state and can only be changed at
stop.
In the stop or running state, the operation panel can display multiple status parameters.
Whether parameters are displayed is determined by the equivalent binary bits converted from
the values of FA-01 and FA-02.
4.2.4 Paramerters display in stop state

In the stop stsate, a total of 12 parameters can be displayed circularly by pressing . You can
select the parameters to be displayed by setting FA-02 (each of the binary bits converted from
the value of FA-02 indicates a parameter).

4 -11
MPDK136 commissioning manual code:YETS-0017-C

The parameter setting description is shown as follows, and the default value is set value in
the factory. Modify the parameters according to the contract.

4 -12
MPDK136 commissioning manual code:YETS-0017-C

4 -13
MPDK136 commissioning manual code:YETS-0017-C

4 -14
MPDK136 commissioning manual code:YETS-0017-C

4 -15
MPDK136 commissioning manual code:YETS-0017-C

4 -16
MPDK136 commissioning manual code:YETS-0017-C

4 -17
MPDK136 commissioning manual code:YETS-0017-C

4 -18
MPDK136 commissioning manual code:YETS-0017-C

4 -19
MPDK136 commissioning manual code:YETS-0017-C

4 -20
MPDK136 commissioning manual code:YETS-0017-C

4 -21
MPDK136 commissioning manual code:YETS-0017-C

4 -22
MPDK136 commissioning manual code:YETS-0017-C

4 -23
MPDK136 commissioning manual code:YETS-0017-C

4 -24
MPDK136 commissioning manual code:YETS-0017-C

4 -25
MPDK136 commissioning manual code:YETS-0017-C

4 -26
MPDK136 commissioning manual code:YETS-0017-C

4 -27
MPDK136 commissioning manual code:YETS-0017-C

4 -28
MPDK136 commissioning manual code:YETS-0017-C

4 -29
MPDK136 commissioning manual code:YETS-0017-C

4 -30
MPDK136 commissioning manual code:YETS-0017-C

4 -31
MPDK136 commissioning manual code:YETS-0017-C

4 -32
MPDK136 commissioning manual code:YETS-0017-C

4 -33
MPDK136 commissioning manual code:YETS-0017-C

4 -34
MPDK136 commissioning manual code:YETS-0017-C

4 -35
MPDK136 commissioning manual code:YETS-0017-C

4 -36
MPDK136 commissioning manual code:YETS-0017-C

4 -37
MPDK136 commissioning manual code:YETS-0017-C

4 -38
MPDK136 commissioning manual code:YETS-0017-C

4 -39
MPDK136 commissioning manual code:YETS-0017-C

Group Fr Leveling adjustment parameters


Leveling 0:Disabled
Fr-00 adjustment 0 - ★
1:Enabled
function
Leveling
Fr-01 adjustment 0~60060 30030 - ★
record 1
~ ~ 0~60060 30030 - ★
Leveling
Fr-20 adjustment 0~60060 30030 - ★
record 20
Group FF Factory parameters
Group FP User parameters
4 -40
MPDK136 commissioning manual code:YETS-0017-C

0:No password
FP-00 User password 0 - ☆ ★
01~65535
0:No operation
Parameter
FP-01 1:Restore default setting 0 - ★
update
2:Clear fault records
User-defined 0:Invalid
FP-02 parameter 0 - ★ ★
1:Valid
display

Group A1 User parameters

Bit0:Door 1 open limit 0 X1


Elevator Bit1:Door 1 close limit 0 X2
function ★
selection (0: Bit2 Door 1 light curtain 0 X3
normally Bit3: overload 0 X4 ★
-A1-00 closed; 1:
normally open) Bit4: full load 1 X5 ★ ★
car top panel Bit5: light load 0 X6 ★ ★
input point
configuration Bit6: up leveling 1 X7

Bit7: down leveling 1 X8
Bit0: Start button warning tone
on hall call panel buzzer of CN7 0 ★
interface
Bit1: firefighting buzzer
position setting (0:JP20 0 ★
output,1:C1/CM output)
Bit2: close two level forced
deceleration test 0
Elevator (0:detection,1:non-detection)
A1-01 function Bit3: close arrival gong function - ★
selection 0 ★
(0:open ,1:close)

Bit4: firefighting buzzer ringing


mode
(A1-01 it is valid when Bit 1 0 ★
is 1, 0: discontinuous prompt 1:
continuous prompt )
Bit5:Power failure emergency mode
canceling E30 fault(0: E30, 1: cancel 0
E30)

4 -41
MPDK136 commissioning manual code:YETS-0017-C

Bit6: Start button warning tone of


car call panel buzzer on CN8
interface 0 ★
(0: no buzzer, 1: press the buzzer
with button)
Bit7: Power failure emergency hall
call display suspend service sign
1
(0:no display,1:display)

Bit8:Standby power running


mode (0: not runnable after returning 0 ★
base station;1: normally run after
returning base station)

Fan energy
A1-03 0~65535 3 min ☆ ★
saving time
Light curtain,
safety edge
A1-04 0~65535 10 S ☆ ★
prompt delay
time
Light load
anti-nuisance
A1-05 0~65535 3 - ★ ★
car call number
setting
E30 detect delay
A1-06 time when 0~65535 65 S ★
returning to level
E30 detect delay
A1-07 time when power 0~65535 65 S ★
failure emergency
Auto reset times
A1-08 under the error 0~65535 3 - ★
E37

Elevator intergration controller operation can be divided into three grades for all the parameters,
as follows:
“☆”:shows the parameter set value can be modified when elevator integration controller is in
stop and running state.
“★”:shows that the parameter set value cann’t be modified when elevator integration
controller is in running state.
“●”:shows that the parameter value is actual detection record value and cann’t be modified.

4 -42
MPDK136 commissioning manual code:YETS-0017-C

The system has automatically checked the modified property of the parameters to avoid the
misoperation from users.)
Function code with ★ in use frequency shows that the parameter is normally used parameter.
The menu items of integrated machine are shown in the above, and related setting of the
menu is descried in the following sections.

4.7 Monitoring menu description:

Function
Parameter name Setting range Default Unit Operation
code
F5-32 Communcation state - - - ●

It is used to monitor the state of CANbus communication with CTB and Modbus
communication with HOP.

When you enter the menu of F5-32, the LEDs on the operation panel indicate the current HOP
communication state. The LEDs are arranged as 5, 4, 3, 2, 1 from left to right. Each segment of
the LEDs is defined in the following table.

communication state monitoring

4 -43
MPDK136 commissioning manual code:YETS-0017-C

A B C D E F G DP Meaning of Segment ON
LED No.
Corresponding normal modbus communication HOP Modbus
address of LED Communication Normal

1 1 2 3 4 5 6 7 8

2 9 10 11 12 13 14 15 16

3 17 18 19 20 21 22 23 24

4 25 26 27 28 29 30 31 Reserved

A B C D E F G DP Meaning of segment OFF


LED No.
Corresponding abnormal modbus communication Modbus Communication
address of LED Abnormal

1 1 2 3 4 5 6 7 8

2 9 10 11 12 13 14 15 16

3 17 18 19 20 21 22 23 24

4 25 26 27 28 29 30 31 Reserved

Number displayed by the


LED No. CTB CANbus communication state
LED

4 -44
MPDK136 commissioning manual code:YETS-0017-C

For example, if the LEDs are shown as the following figure, it indicates that the Modbus
communication of addresses 1、5、6、7、12、15、16、18、19、21、22、23、25、26、27 are
abnormal. The Modbus communication of other addresses is normal. The CANbus
communication state displayed by the LED is 3, communication is interfered.

Example of communication state monitoring


Function
Name Setting range Unit Property
code Default
Terminal state Monitoring of I/O terminals on
F5-34 0 - ●
display MCB
Teminal state Monitoring of I/O terminals on
F5-35 0 - ●
display CTB, CCB and HOP

These parameters are used to monitor the state of all I/O terminals of the system
The LEDs of F5-34/35 are arranged as 5、4、3、2、1 from left to right.
Each segment of the LEDs is defined in the following table.

Terminal state monitoring


F5-34 F5-35

No. Segment Indication No. Indication


Segment
1 A - 1 A -

4 -45
MPDK136 commissioning manual code:YETS-0017-C

F5-34 F5-35

No. Segment Indication No. Indication


Segment
B Up leveling signal B Light curtain 2
C Down leveling signal C -
D Door zone signal D Door2 open limit
E 1 safety circuit feedback 1 E -
F Door lock circuit feedback 1 F Door 2 close limit
G RUN contactor feedback G -
DP Brake contactor feedback 1 DP -
A Inspection signal A Door open button
B Inspection up signal B Door close button
C Inspection down signal C Door open delay button
D Fire emergency signal D Direct travel ride signal
2 E Up limit signal 2 E Attendant signal
F Down limit signal F Direction change signal
Independent running
G Overload signal G
signal
Firefighter operation
DP Full-load signal DP
signal
A Up slow-down 1 signal A Door open output 1
B Down slow-down 1 signal B Door close output 1
C Up slow-down 2 signal C Door lock signal
D Down slow-down 2 signal D Door open output 2
3 E Up slow-down 3 signal 3 E Door close ouput 2
F Down slow-down 3 signal F Door lock signal
Shorting door lock circuit
G G Up arrival gong
contactor feedback
DP firefighter running signal DP Down arrival gong
Door machine 1 light Door open button
A A
curtain display
Door close button
B Door machine 2 light curtain B
4 4 display
Door open delay button
C Brake contactor feedback 2 C
display
D UPS input D Non-door zone stop
4 -46
MPDK136 commissioning manual code:YETS-0017-C

F5-34 F5-35

No. Segment Indication No. Indication


Segment
E Elevator lock input E Reserved
F Safety circuit feedback 2 F Buzzer output
Shorting PMSM stator
G G Reserved
contactor feedback
DP Door lock circuit feedback 2 DP Energy saving sign
A Reserved A -
B Run contactor output B -
C Brake contactor output C -
Shorting door lock circuit 5
5 D D -
contactor control
Fire emergency floor arrival
E E -
signal
F - F -
DP - DP -

A1-02 Monitoring CTB and CCB menu

LED No. Segment Indication Segment


A -
B -
C -
The first D -
one from E -
the right F Lighting control JP22 input
G Fan control JP23 input
DP BMS monitoring alarm bell
JP24 input
A “ON” at Door 1# open limit
The
B “ON” at Door 1# close limit
second one
C “ON” when Door 1# light
from the
curtain is blocked.
right
D ON at overload

4 -47
MPDK136 commissioning manual code:YETS-0017-C

E ON at full-load
F ON at light load
G ON when up leveling switch
acts.
DP ON when down leveling switch
acts
A JP20 output when overload
occurs or light curtain is blocked
B JP20 output when fire
emergency floor arrival
C The buzzer with car call board
will ring when CN7 button is
The third pushed
from the D Lighting relay C3/C3M output
right E Fan relayA/AM output
F The buzzer with car call board
will ring when CN8 button is
pushed
G C1/CM output when fire
emergency floor arrival
DP -

The margin in the table is function reserved.

4.8 Parameters description


4.8.1 Carrier frequency adjustment(F0-07)
Function
Name Setting range Default Unit Property
code
F0-07 Carrier frequency 0.5~16.0 8 kHz ★

Setting of controller carrier frequency


The carrier frequency is closely related to the motor noise during running. When it is
generally set above 6 KHz, mute running is achieved. It is recommended to set the carrier
frequency to the lowest within the allowable noise, which reduces the controller loss and radio
frequency interference.
If the carrier frequency is low, output current has high harmonics, and the power loss and
temperature rise of the motor increase.
If the carrier frequency is high, power loss and temperature rise of the motor declines.
However, the system has an increase in power loss, temperature rise and interference.
4 -48
MPDK136 commissioning manual code:YETS-0017-C

Influences of carrier frequency adjustment


Carrier
low ~ high
frequency
motor noise large ~ small
Output current
bad ~ good
waveform
Motor
temperature High ~ Low
rise
Controller
termperature Low ~ High
rise
Leakage
Small ~ Large
current
External
radiation Small ~ Large
interference

Note: On certain environment conditions(the heatsink temperature is too high), the system will
reduce the carrier frequency to provide overheat protection for the controller, preventing the
controller from being damaged due to overheat. If the temperature cannot reduce in this case,
the controller reports the overheat fault.
4.8.2 Vector Control Parameter(F2-00~F2-05)
Function Propert
Name Setting Range Default Unit
code y
Speed loop
F2-00 proportional gain 0~100 50 - ★
KP1
Speed loop integral
F2-01 0.01~10.00 0.5 - ★
time Ti1
Switchover
F2-02 0.00~F2-05 2 Hz ★
frequency 1

F2-00 and F2-01 are P1 regulation parameters when the running frequency is smaller than the
value of F2-02 (Switchover frequency 1)

4 -49
MPDK136 commissioning manual code:YETS-0017-C

Function
Name Setting range Default Unit Property
code
Speed loop
F2-03 proportional gain 0~100 50 - ★
KP2
Speed loop integral
F2-04 0.01~10.00 0.5 - ★
time Ti2
Switchover
F2-05 F2-02~F0-06 5 Hz ★
frequency 2

F2-03 and F2-04 are PI regulation parameters when the running frequency is larger than the
value of F2-05 (Switchover frequency2).
If the running frequency is between F2-02 and F2-05, the speed loop PI parameters are obtained
from the weighted average value of the two groups of PI parameters (F2-00, F2-01 and F2-03,
F2-04).

Relationship between running frequencies and PI parameters

The speed dynamic response characteristics in vector control can be adjusted by setting the
proportional gain and integral time of the speed regulator.

4 -50
MPDK136 commissioning manual code:YETS-0017-C

To achieve a faster system response, increase the proportional gain and reduce the integral time.
Be aware that this may lead to system oscillation;
The recommended adjustment method is as follows:
If the default setting cannot meet the requirements, make proper adjustment. Increase the
proportional gain first to ensure that the system does not oscillate, and then reduce the integral
tome to ensure that the system has quick response and small overshoot.
If both F2-02 (Switchover frequency 1) and F2-05 (Switchover frequency 2) are 0, only F2-03
and F2-04 are valid.

4.8.3 Running Control Parameters (F3-00~F3-07)


Function
Parameter Name Setting Range Default Unit Property
Code
F3-00 Startup speed 0.000~0.030 0 m/s ★
Startup holding
F3-01 0.000~0.500 0 s ★
time

These two parameters are used to set the startup speed and startup speed holding time. For
details, see velocity curve sketch map.
The parameters may reduce the terrace feeling at startup due to static friction between the guide
rail and the guide shoes.

Function
Name Setting range Default Unit Property
code
F3-02 Acceleration rate 0.300~2.000 0.6 m/s2 ★
Acceleration start
F3-03 0.300~4.000 2.5 s ★
jerk time
Acceleration end
F3-04 0.300~4.000 2.5 s ★
jerk time
These parameters are used to set the running curve during acceleration of the elevator.

Function
Parameter Name Setting Range Default Unit Property
code
F3-05 Deceleration rate 0.300~2.000 0.6 m/s2 ★
4 -51
MPDK136 commissioning manual code:YETS-0017-C

Deceleration end
F3-06 0.300~4.000 2.5 s ★
jerk time
Deceleration start
F3-07 0.300~4.000 2.5 s ★
jerk time

These parameters are used to set the running curve during deceleration of the elevator.

F3-02 (F3-05) is the acceleration rate (decelaration rate) in the straight-line acceleration process
(deceleration process) of the S curve.

F3-03(F3-07)is the time for the rate to increase from 0 to the value set in F3-02(F3-05)in the
end jerk segment of the S curve. The larger the value is, the smoother the jerk is.

F3-04(F3-06)is the time for the rate to decrease from the value set in F3-02(F3-05)to 0 in the
start jerk segment of the S curve. The larger the value is, the smoother the jerk is.

Setting the running curve

Velocity curve sketch map

4.8.4 Time sequence adjustment(F3-18~F3-20)


Function
Parameter Name Setting Range Default Unit Property
Code
F3-18 Zero-speed control 0.000~1.000 0.200 s ★
4 -52
MPDK136 commissioning manual code:YETS-0017-C

time at startup
F3-19 Brake release time 0.000~1.000 0.600 s ★
Stop moment output
F3-20 0.000~1.000 0.300 s ★
delay

These parameters are used to set the time related to the zero-speed holding current output and
braking action delay

F3-18 (Zero-speed control time at startup) specifies the time from output of the RUN contactor
to output of the brake contactor, during which the controller performs excitation on the motor
and outputs zero-speed current with large startup torque.

F3-19 (Brake release delay) specifies the time from the moment when the system sends the
brake release command to the moment when the brake is completely released, during which the
system retains the zero-speed torque current output.
F3-20(Stop moment output delay)specifies the zero-speed output time when the running curve
ends.
F8-11 (Brake apply delay) specifies the time from the moment when the system sends the brake
command to the moment when the brake is completel applied, during which the system retains
the zero-speed torque current output.

Running time sequence

4.8.5 Leveling adjustment(F4-00~F4-83)


Function
Parameters Name Setting range Default Unit Property
code
F4-00 Levelling adjustment 0~60 30 mm ★

4 -53
MPDK136 commissioning manual code:YETS-0017-C

It is used to adjust the leveling accurancy at elevator stop. If over-leveling occurs in elevator
stop at all floors, decrease the value of this parameter property. If under-leveling occurs in
elevator stop at all floors, increase the value of this parameter property.
This parameter takes effect to leveling of all floors. Therefore, if leveling at a single floor is
inaccurate, adjust the postion of the leveling plate.
The controller has the advanced distance control algorithm and adopts many methods to ensure
stability of direct stop. Generally you need not modify this parameter.

Function
Parameter Name Setting range Default Unit Property
code
F4-01 Current floor F6-01~F6-00 1 - ★

This parameter indicates the current floor of the elevator car.


The system automatically changes the value of this parameter during running, and corrects
it at leveling position (door open limit) after the up slow-down and down slow-down switches
act. At non-bottom floor and top-floor leveling, you can also manually modify this parameter,
but the value must be consistent with the actual current floor.

Function
Parameter Name Setting range Default Unit property
code
High byte of current
F4-02 0~65535 1 Pulses ●
floor position
Low byte of current
F4-03 0~65535 34464 Pulses ●
floor position

These two parameters indicate the absolute pulses of the current position of the elevator car
relative to the bottom leveling position.
The position data of the controller in the shaft is recorded in pulses. Each position is
expressed by a 32-bit binary number, where the high 16 bits indicate the high byte of the floor
postion, and the low 16 bits indicate the low byte of the floor position.

Function
Parameter Name Setting range Default Unit Property
code

4 -54
MPDK136 commissioning manual code:YETS-0017-C

length 1 of leveling
F4-04 0~65535 0 mm ★
plate
length 2 of leveling
F4-05 0~65535 0 mm ★
plate

These two parameter respectively indicate the pulses corresponding to the length of the
magnetic value and the length between two leveling sensors. They are automatically recorded
during shaft auto-tuning

Function
Parameter Name Setting range Default Unit Property
code
High byte of floor height
F4-06 0~65535 0 Pulses ★
1
Low byte of floor height
F4-07 0~65535 0 Pulses ★
1
Floor height 2 to floor height 38
High byte of floor height
F4-82 0~65535 0 Pulses ★
39
Low byte of floor height
F4-83 0~65535 0 Pulses ★
39
These parameters indicate the pulses corresponding to the floor height i (between the leveling
plates of floor i and floor i+1). Each floor height is expressed by a 32-bit binary number, where
the high 16 bits indicate the high byte of the floor height, and the low 16 bits indicate the low
byte of the floor height. On normal conditions, the floor height i of each floor is almost the
same.
4.8.6 Service floor setting (F6-05、F6-06、F6-35)
System can choose to close or activate a certain or several elevator service floors as required.
F6-05 Service floors 1(Floors 1-16)
F6-06 Service floors 2(Floors 17-32)
F6-35 Service floors 3(Floors 33-40)
These parameters are used to set the service floors among floors 1-40. F6-05(Service floors
1) corresponds to floors 1-16. F6-06 (Service floors 2) corresponds to floors 17-32. F6-35
(Service floors 3) corresponds to floors 33-40.
Whether service floors of a parameter are allowed is indicated by a 16-bit binary number.
The 16 bits respectively correspond to 16 floors from low to high. “1” indicates that the elevator
4 -55
MPDK136 commissioning manual code:YETS-0017-C

will respond to calls of this floor, and “0” indicates that the elevator will not respond to calls of
this floor.
For example, the service floors of a 16-floor elevator are listed in the following table.
Whether Whether
Bit Floor Setting Bit Floor Setting
Service Service
Bit0 Floor1 Allowed 1 Bit8 Floor 9 Forbidden 0
Bit1 Floor2 Forbidden 0 Bit9 Floor 10 Allowed 1
Bit2 Floor3 Allowed 1 Bit10 Floor 11 Allowed 1
Bit3 Floor4 Forbidden 1 Bit11 Floor 12 Forbidden 0
Bit4 Floor5 Allowed 1 Bit12 Floor 13 Allowed 1
Bit5 Floor6 Allowed 1 Bit13 Floor 14 Allowed 1
Bit6 Floor7 Allowed 1 Bit14 Floor 15 Allowed 1
Bit7 Floor8 Forbidden 0 Bit15 Floor 16 Allowed 1

The binary number indicated by the preceding table is 1111 0110 0111 1101. the decimal
equivalent of this binary number is 63101. Then set F6-05 to 63101.

4.8.7 Time-based service (F6-18~F6-25、F6-36、F6-37)


These parameters define the time periods of two groups of time-based services and
corresponding service floors.
Function code Parameter Name Setting range Default Unit Property

Start time of
F6-18 time-based floor 00.00~23.59 00.00 - ☆
service 1

End time of
F6-19 time-based floor 00.00~23.59 00.00 - ☆
service 1

Service floor 1 of
F6-20 time-based floor 0~65535 65535 - ☆
service 1

F6-21 Service floor 2 of 0~65535 65535 - ☆

4 -56
MPDK136 commissioning manual code:YETS-0017-C

Function code Parameter Name Setting range Default Unit Property

time-based floor
service 1

Service floor 3 of
F6-36 time-based floor 0~65535 65535 - ☆
service 1

Start time of
F6-22 time-based floor 00.00~23.59 00.00 - ☆
service 2

End time of
F6-23 time-based floor 00.00~23.59 00.00 - ☆
service 2

Service floor 1 of
F6-24 time-based floor 0~65535 65535 - ☆
service 2

Service floor 2 of
F6-25 time-based floor 0~65535 65535 - ☆
service 2

Service floor 3 of
F6-37 time-based floor 0~65535 65535 - ☆
service 2

These parameters define the time periods of two groups of time-based services and
corresponding service floors.
Service floor 1 corresponds to floors 1-16, service floor 2 corresponds to floors 17-32, and
service floor 3 corresponds to floors 33-40. In the time period of time-based service 1(set by
F6-18 and F6-19), the elevator responds to the service floors set by F6-20, F6-21 and F6-36 but
ignores the service floors set by F6-05, F6-06 and F5-35. The setting of time-based service
floors is the same as that of service floors in F6-05.
During the time-based floor service period, the settings of F6-05, F6-06 and F5-35 are invalid. If

4 -57
MPDK136 commissioning manual code:YETS-0017-C

the two periods of time-based floor service 1 and time-based floor service 2 are overlapped, the
system implements time-based floor service 1 because it has higher priority level.

4.8.8 Peak time running (F6-26~F6-31)


Function Parameter
Setting range Default Unit Property
code Name
Peak 1 start
F6-26 00.00~23.59 00.00 HH.MM ☆
time
Peak 1 end
F6-27 00.00~23.59 00.00 HH.MM ☆
time
F6-28 Peak 1 floor F6-01~F6-00 1 - ★
Peak 2 start
F6-29 00.00~23.59 00.00 HH.MM ☆
time
Peak 2 end
F6-30 00.00~23.59 00.00 HH.MM ☆
time
F6-31 Peak 2 floor F6-01~F6-00 1 - ★

These parameters define two peak time periods in parallel mode and group control mode and
corresponding floors. During a peak time period, if there are more than three car calls from the
peak floor, the elevator enters the peak service state. At the moment, the car calls from the peak
floor are valid all the time. The elevator returns to this floor if it is idle.
4.8.9 Analog quantity weighing (F8-00)
Function
Parameter Name Setting Range Default Unit Property
code
Load for load cell
F8-00 0~100 0 % ★
auto-tuning
It is used to set the load for load cell auto-tuning.
To perform load cell auto-tuning, do as follows:
1. Ensure that F8-01 is set to 0 and F5-36 is set to 2 or 3 to make the system allow load cell auto
tuning.
2. Stop the elevator at any floor, with the car in the no-load state. Set F8-00 to 0 and press the
ENTER key.
4 -58
MPDK136 commissioning manual code:YETS-0017-C

3. Put N% load in the car. Then set F8-00 to N and press the ENTER key.
For example, if you put 500kg load in the elevator with related load of 1000kg, set F8-00 to 50.
After the load-cell auto-tuning is completed, the corresponding no-load and full-load data will
be recorded in F8-06 and F8-07. You can also manually input data according to the actual
situation.
4.8.10 Parameter copying
Use hand-hold operator to upload and download parameters to control system.

Press the keys and simultaneously for three seconds to enter the menu

mode of the operator. In the operator menu mode, press the key to return the
parameter interface of integrated elevator control system.

U0-00 is shown directly after entering the operator interface. Press the key to
view function code value. If there is flicker bit,the function code can be modified. Press the key

again to store the parameter and go back up one level interface.


Parameter upload and download: enter the menu mode of operator, and set U0-05 to start
parameter upload and download function, the specific process is shown as follows:
When the operator can operate the function code of intergrated elevator control system and
the system doesn’t run:

1. Set U0-05=1, press the key to download the parameter, the system uploads
the parameter to the operator

2. Set U0-05=2, press the key to upload the parameter, the operator uploads the
parameter to the system when it stores the valid parameter.

4 -59
MPDK136 commissioning manual code:YETS-0017-C

3. Set U0-05=3, press the key to delete the parameter stored in the operator.
During the upload, interface shows the data size. After the upload is finished, interface will
show U0-06. When the operator and the system lose the communication or the user mismatches,
upload and download cannot be done.
During the operation of the system, upload and download cannot be done.
Erro indication:
During the upload and download, if the system runs, the operation will fail and the interface
will show FAIL.
When the operator does not store the valid parameters, the upload will fail and interface will
show FAIL.

Press the key or to delete the indication FAIL in the interface and return
to the menu U0-xx.

4.8.11 Commissioning in car


When the operator is connected by car adjusting cable in the operation panel, the operator
only has the function of adjusting leveling, correcting the floor display and monitoring the state
of main controller and so on.
4.9 Confirmation of safety circuit
After the system is powered on, the adjustment of safety circuit and door lock circuit will
be confirmed. Three point X25、X26 and X27 on the system are valid, and the system does not
report the error E41.
If normal display is not correct or there is fault display, troubleshooting shall be timely
done to do the debugging.

4 -60
MPDK136 commissioning manual Code:YETS-0017-C

5 Emergency electro motion/ Inspection running


Before emergency electro motion and inspection running is carried out, check and
confirm and set the parameters as the above mentioned.
5.1 The necessary checks before adjustment
(1) Confirm that nobody is in the shaft and the car again, and the landing door is closed
or obvious warning mark is set.
(2) The running conditions of the barrier-free elevator.
(3) Close the main power supply and connect with brake wire.
(4) Confirm the current elevator is in the status of machine room test running, and
confirm the safety circuit and door lock circuit.
5.2 The confirmation of main controller running conditions

The content and correct condition list of input hardware point:


Input point Content Description
X1 Running inspection Running, OFF; Stop, ON
X2 Slow/up Close is effective
X3 Slow/down Close is effective
X4 Inspection /normal Close is in normal running
condition.
X5 Door zone It is closed at door zone.
X6 Limit/ up Signal cut-off during upper
limit
X7 Limit/ down Signal cut-off during lower
limit
X8 Up forced to slow When the lift is in the middle
down1 of the shaft ,forced slowdown
X9 Down forced to slow point closed;
down1 When the lift runs to the end
X10 Up forced to change stop, it passes grade 2
speed 2 forced slowdown switch and

5-1
MPDK136 commissioning manual Code:YETS-0017-C

X11 Down forced to grade 1 forced slowdown


change speed 2 switch, and the forced
slowdown points keep
disconnected;
X12 break switch1 ON when switch off
X13 break switch2 ON when switch off
X14 Motor overheated ON indicates that it is running
detection normally.
X15 Fire detection OFF when fire happens
X16 Firefighter OFF when firefighter
X17 Back-up
X18 Power failure ON indicates the running of
emergency test power failure emergency
X19 Earthquake ON when earthquake
happens
X20 Back-up power ON indicates the running of
back-up power
X21 Door closing ON after security module
feedback finishes door closing
X22 Overload OFF indicates overload.
X23 Full-load ON indicates full-load.
X24 Light-load OFF indicates light-load.
X25 Safety circuit 110VAC inspect safety circuit.
detection
X26 Car door security 110VAC inspects car door
inspection lock.
X27 Landing door security 110VAC inspects landing door
inspection lock

Note: The input point is effective in high potential.


5.3 The adjustment of emergency electro motion
(1) Commissioning procedure:

5-2
MPDK136 commissioning manual Code:YETS-0017-C

a. Close main supply, reset the switch of control cabinet emergency stop, ensure the
inverter in the control cabinet is electrified, and the display is operating. The main
controller is in the status of TEST.
b. Car top inspect operation is in normal condition.
c .Ensure the input conditions of above list is available, handheld operator F5-34 menu
can be monitored.
d. The inspection speed is set to 300mm/s when delivery from factory.
e.Set the motor degugging relevant parameters.

5-3
MPDK136 commissioning manual Code:YETS-0017-C

Motor Degugging Relevant Parameters

Function Factory
Parameter Name Description
Code setting
0: asynchronous
motor
F1-25 Motor type
1: synchronous
motor
0:SIN/COS encoder
F1-00 Encoder type 1:UVW encoder 0
2:ABZ encoder
Encoder pulses per
F1-12 0~10000 2048
revolution

These parameters
Rated moter power are model dependent,
/ voltage /current / and you need to
F1-01~
frequency manually input them
F1-05 / rotational speed
according to the
nameplate.

0: Sensorless flux
vector control (SFVC)
Control mode:close-loop 1:close-loop vector
F0-00 vector control control 1
2: Voltage/Frequency
(V/F) control

0: Operation panel
control
F0-01 Command source selection 1
1: Distance control

0: Pre-torque invalid
1: Load cell
pre-torque
F8-01 Pre-torque selection compensation 2
2: Automatic
pre-torque
compensation
0: No operation
With-load tuning, empty 1: With-load tuning
F1-11 load tuning, shaft 2: No-load tuning 0
self-learning 3: Shaft self-learning
5-4
MPDK136 commissioning manual Code:YETS-0017-C

f. Push upward, downward button in controller cabinet, the door should close
automatically.

g.Synchronous motor tuning: Set F1-25 as 1, confirm whether the value of F1-00、

F0-01、F1-12 is factory setting. Set F1-01~F1-05 parameters according to motor

name.After confirm the parameter is correct, change F1-11 as 1. Operation panel


indicates TUNE.As inspecting up or down buttons in control cabinet, start to tune
(motor runs).The motor runs second time, tuning is finished.

h. Asynchronous motor tuning: Set F1-25 as 0, F1-00 as 2, F1-12 as 1024.Set F1-01~

F1-05 parameters according to motor name.After confirm parameters is correct, change


F0-01 as 0, F1-11 as 1.Operation panel indicates TUNE, press RUN, moter stops
tuning. Tuning gets parameters: F1-14 to F1-18. Resume F0-01 as 1, and tuning is
finished.
(2).Precautions for Motor Auto-tuning
A.Ensure that all wiring and installation meet the safety specifications.
B.Ensure that the motor wiring is correct (UVW cables of the motor respectively
connected to UVW cables of the controller) for with-load auto-tuning. If the motor wiring
is incorrect, the motor may jitter or fail to run after the brake is released; in this case,
you need to replace any two of the motor UVW cables.
C.Reset the current fault and then start auto-tuning, because the system cannot enter
the auto-tuning state ("TUNE" is not displayed) when there is a fault.
D.Perform motor auto-tuning again if the phase sequence or encoder of the
synchronous motor is changed.
E.For the synchronous motor, perform three or more times of auto-tuning, compare the
obtained values of F1-06. The value deviation of F1-06 shall be within ±5°, which
indicates that the auto-tuning is successful.
F. After the auto-tuning is completed, perform trial inspection running. Check whether the
current is normal, whether the actual running direction is the same as the set direction.If
the running direction is different from the set direction, change the value of F2-10.
G.With-load auto-tuning is dangerous (inspection-speed running of many control cabinets
is emergency electric running and the shaft safety circuit is shorted). Ensure that there is
no person in the shaft in this auto-tuning mode.

5-5
MPDK136 commissioning manual Code:YETS-0017-C

H. For asynchronous motor, when rated power F1-01 is changed, parameter F1-14~

F1-18 will be restored.


(3). If input conditions are not available, conduct commissioning corresponding to
collateral drawings and find out the malfunction point. If there is concerned malfunction
alarm, consult breakdown list, and solve the problems in time.
(4).Notice for TEST running:
A.When elevator external safety circuit: speed limit switch 5SQ1, upper terminal
landing switch 5SQ2, lower terminal landing switch 5SQ4, car buffer switch
5SQ6, counterweight buffer switch 5SQ7, safety gear switch 5SQ8 is running, theTEST
running can be used.
B. Before operating, make sure that the car door is closed completely and nobody is in
the shaft.
C. TEST running can only be carried out by the professional adjustment and
maintenance people qualified by BLT ELEVATOR COMPANY. Others are forbidden
to carry out these functions privately.
D.When inspection, if lift running direction is different from inspection direction, you can
change F2-10 data, lift running direction and position impuls change.
F2-10 parameters change direction of lift. The setting values are as following:
0: Direction is unchanged;
1: Running direction is set to opposite, and the position impuls dirction is set to
opposite.
2: Runing direction is same, the position impuls dirction is set to opposite.
3: Runing dirction is set to opposite, the position impuls dirction is same.
In the function code, running direction (under the condition of moter wiring is
unchanged) and position signal(refer to F4-03 , which is used to recognized impulse
direction of lift location.) can be set to opposite.
For example,when the lift installation is finished, inspect going up, but actually it is
going down, so need set running direction as its opposite.While inspect going up, F4-03

5-6
MPDK136 commissioning manual Code:YETS-0017-C

indicates position impulse reduces (i.e. position is going down), so need set position
impulse dirction as opposite.
5.4 Commissioning procedures for car ceiling inspection
5.4.1 After normal running TEST in machine room, inspection works on car ceiling can
be carried out on the premise of confirming safety. Before car ceiling inspection is
carried out, the working line of car ceiling inspection should be confirmed right. All
buttons act normally including car ceiling emergency-stop safety switch.
5.4.2 When car ceiling inspection is operating, the machine room emergency electro
motion is invalid.
5.4.3 If up and down buttons on car top inspection is different from elevator running
direction, the working line of car ceiling inspection direction shall be checked. The
change of direction instruction toward inverter and other changes in control cabinet are
not allowed.
5.4.4 If the door of elevator is open, it shall be closed automatically after pressing up
and down button on car ceiling.
5.5 Notice for car ceiling inspection:
When car ceiling inspection, press emergency button to stop lift in case of any
emergency.
Professional on the car ceiling shall be careful from time to time!

5-7
MPDK136 commissioning manual Code:YETS-0017-C

6 Instructions of other electric components of door operator

6- Emerson EV3200 synchronous door machine controller debugging method

6.1.1 Sketch map of electrical components

6.1.2 System Introduction:


A synchronous door motor and matched controller are adopted for the door machine. The
synchronous door machine has no position detection switch (Open limit, open speed change,
close speed change, close limit), so the door motor encoder is used to gather position and
speed signals.
6.1.3 Door motor
Door motor adopts variable-frequency three-phase synchronous motor. The motor lines are
connected directly with terminals U, V ,W, PE of the elevator door controller, the motor encoder
line connected to the door machine encoder interface (see table). Door motor is directly driven
by the elevator door controller

Door machine
P24 COM A B X1
terminal No.
Encoder line color red black green brown white

Door machine: Xiangshan sanhuan TYC135-1synchronous permanent magnet motor, rated


current of 1.35 A, rated voltage 50 v, rated speed 180 r/min, the rated torque 2.7 Nm, rated
frequency24 HZ, rated power 50 W

6-1
MPDK136 commissioning manual Code:YETS-0017-C

Incremental encoder: MEC24IN1024PU2, input voltage 8-30V,1024 pulse encoder, output A B Z


Z- VDD GND

6.1.4 Door machine controller


Door machine controller input power is single-phase AC220V, which is output to the motor for
three phase voltage (according to the motor voltage), door machine parameter can be set by
code display debugging keyboard. ( as following image).

6-2
MPDK136 commissioning manual Code:YETS-0017-C

PRG:Programming key is used for switching among stop state or operating state and

programming state

FUNC/DATA:Function / data key is used for choosing data monitoring mode and data writing

confirmation

Up arrow:Increase key is used for increasing of data or function parameters.

Down arrow:Decrease key is used for decreasing of data or function parameters.

Double right arrow:Shift key In the state of running and stop, choose the key to show the

parameter; when setting the data, choose the key to set the modification position of the data.

OD:Under the panel control, it is used for opening the door (forward)

CD: Under the panel, it is used for closing the door (reversal)

STOP/RESET:Stop/ fault reset key Under the panel operation mode, it is used for stopping

or resetting to end the fault alarm.


6.1.5 Wiring socket

6-3
MPDK136 commissioning manual Code:YETS-0017-C

Connection of nine-core wiring socket (for door machine controller) is shown as follows

Socket hole No. BLT wire No. Door machine terminal No. Function description
1 114 L Power supply
2 115 N Power supply
3 601 PC1 Open limit output signal
4 602 PC2 Close limit output signal
5 614 OD Door opening input
signal
6 615 CD Door closing input signal
7 0V PA1 and PA2 Door controller output
signal common terminal
8 616 COM Door controller input
signal common terminal
9 617 X2 Door nudging input
signal
PE PE Ground

Nine-core wiring socket (for door machine controller)

6.1.6 Circuit check


Connection between door machine controller and door machine shall be checked according to
the above 6.5. And check whether motor drive line and encoder line are separately laid. Finally
power on to the door machine and parameters adjustment shall be done.

6.1.7 Parameters setting

Introduction of controller work state


Stop state- when controller has been electrified and no fault and no operation, all the parameters
6-4
MPDK136 commissioning manual Code:YETS-0017-C

shall be set in the state.


Programming state- use the operation panel to modify and set the functional parameters of the
controller.

Running state- controller outputs the terminals U 、V 、W and power.

Fault alarm state- due to fault from outside equipment or control interior or misoperation, the
controller alarms corresponding fault code and blocks the output
6.1.7.2 Operational mode description of the controller
The controller has four operational modes: speed control, distance control 1, distance
control 2, distance control 3. BLT uses distance control 1.
6.1.7.3 Function parameters classification
The series of controller has 141 function parameters, which can be divided into ten groups
according to the sequence number and function.

1. Functional parameters group of basic operational parameters F0(F0.00-F0.08)

2. Functional parameters group of door opening curve parameters F1(F1.00-F1.15)

3. Functional parameters group of door closing curve F2(F2.00-F2.16)

4. Functional parameters group of enhancement function parameters F3(F3.00-F3.18)

5. Functional parameters group of door width self-learning F4(F4.00-F4.12)

6. Functional parameters group of multi-functional terminal F5(F5.00-F5.07)

7. Functional parameters group of motor parameters F6(F6.00~F6.13)

8. Functional parameters group of vector control F7(F7.00~F7.10)(Not used by BLT)

9. Communication parameters group F8(F8.00~F8.10)-reserved (Not used by BLT)

10. Display and monitoring parameters group F9(F9.00~F9.22)

6.1.7.4 Functional parameters setting method


Set the functional parameters by operation panel.
Press the programming key to enter programming state. Digital display tube on operation
6-5
MPDK136 commissioning manual Code:YETS-0017-C

panel shows F0 group functional parameters.


Press the increase key to turn to the functional parameters group whose content
parameters need to be changed.
Press FUNC/DATA key to enter subordinate functional parameters corresponding to
functional parameters group. (e.g. F1.00)
Press the increase key to enter the functional parameters to be adjusted. (e.g. F1.04)
Press FUNC/DATA key to enter functional parameters value to be adjusted.
Choose the adjusting bit (ones, tens and hundreds) by shift key and adjust the parameter
value by increase key and decrease key.
Press FUNC/DATA key to save it, and the parameters setting is finished.
6.1.7.5 Operation and stop parameters display method
Set the parameters F9.00 and F9.01 to choose operating and stop parameters.
During the running of the controller, operating parameters chosen by F9.00 shall be displayed in
a cycle by the shift key on operation panel.
In the stop state of the controller, preferentially display the parameters chosen by F9.01, and

display stop parameters in a cycle by shift key on operation panel.

6.1.7.6 Motor parameters tuning

EV3200 series controller adopts vector control technology. Before running motor parameter

tuning shall be carried out. Use the operation panel to start tuning and stop. Before tuning

ensure that the motor is out of the load, otherwise the motor parameters are not accurate

When synchronous motor tunes, connect the encoder firstly. And take the controller as
factory default parameters condition for example:

1) Set the general inverter panel operation mode and set the functional parameters

F0.02 to 0;

2) Set the control method as distance control 1(Closed loop vector control at the time);

set functional parameter F0.01 to 1;

6-6
MPDK136 commissioning manual Code:YETS-0017-C

3) Set motor type and set the functional parameter F6.00 to 1 (synchronous motor)

4) Input motor nameplate parameter, and correctly input corresponding motor

nameplate parameters into functional parameter F6.01~F6.03 and F6.05~F6.06.

The parameter values have been set when leaving factory which shall be checked
before tuning.

F6.01:motor related power (W) 50

F6.02:motor related voltage(v) 50

F6.03: motor related current (A) 1.35

F6.05: motor related frequency (Hz)24

F6.06: motor related rotation speed(rpm)180

5) Set the pulse count of the encoder per revolution and functional parameter F4.01.

6)Set encoder type and set functional parameter F4.00 to 0 (24V encoder)or 1 (5V

encoder);

7)Set parameters tuning function and set functional parameter F6.07 to1.

8) Press door opening key on the panel to start motor parameter tuning. Operation panel
LED displays “TUNE”. During tuning the motor shall run according to fixed mode and no
need pay attention.
9) After finishing the tuning the controller automatically stop and F6.07 automatically revert

to 0 and update the content of F6.08~F6.13 and F4.03.

10)If the panel displays faults when tuning, press stop/fault reset key for resetting. After

resetting there are the following two conditions:

a、 If fault code is E025 (encoder faults), change the setting value of F4.02 after

resetting; if it still displays E025 after tuning, check encoder connection.

b、 If there are other faults, check connection and related motor parameters after
6-7
MPDK136 commissioning manual Code:YETS-0017-C

resetting to ensure it is accurate.


11) The synchronous motor needs to be tuned at least twice. Compare whether the tuned
magnetic pole initial angle (F4.03) difference is less than 10°, if the difference is more than
10°, the error is too big, need to be tuned again; If the angle difference is (360°/ motor
pole-pairs number) integer multiple, tuning results are qualified.

12)After finishing the above work, set the parameter F0.02 to 2 (door motor terminal

control mode), at this time the terminal controls the opening and closing of door machine,
namely elevator controller controls the running of door machine.
13)Door width self-learning
Firstly ensure F4 group parameters setting is correct, and set F0.02 to 1, F4.05 to 1.
Confirm that the door can be normally opened and closed and press the door opening key
on the panel to do self-learning of door width. At the same time the door machine runs at
self-learning speed according to the operation procedure of close-open-close, and door
machine saves door width information after completing the self-learning. After finishing the
above work set F0.02 to 2. The tuning and learning work is finished.
14) Parameters adjustment
Door machine parameters table is shown as follows for reference. According to the
difference of door width and weight on site set the parameters such as speed and moment
and so on to satisfy the needs of the users and national standard.
6.1.7.7 Parameters table (for reference)
In accordance with the motor and encoder in 6.3, door machine parameters table is shown
as follows for reference. According to the difference of door width and weight on site set the
parameters such as speed and torque and so on to satisfy the needs of the users and
national standard. ( * stands for read-only parameter)

Adjustment parameters table on site(F1、F2)

F1:Door opening running curve parameter F1 group


Functional parameter Name Setting range Minimum unit Default BLT setting

6-8
MPDK136 commissioning manual Code:YETS-0017-C

Door open start 10~9999ms 1ms 500ms 500


F1.00 creep time is
controlled by speed.

Door open start 0~30.0%(door 0.1% 15.0% 0


creep distance is
F1.01 width)
controlled by
distance
Door open start 1.00~25.00Hz 0.01Hz 7.00Hz 7
F1.02
creep speed
Door opening 0.1~3600s 0.1s 2s 1.5
F1.03
acceleration time
Door opening 0.1~3600s 0.1s 2s 1.5
F1.03 acceleration time

Door opening high Maximum 0.01Hz 20.00H 20


F1.04 speed frequency z

0.00~F0.04
Door opening high Maximum 0.01Hz 25.00H 20

F1.05 speed during peak frequency z


running 0.00~F0.04

Door opening 60 % ~ 95 % 0.1% 70.0% 70


Deceleration point is
F1.06 (door width)
set according to
distance
Door open 0.1~3600s 0.1s 2s 1.2
F1.07
deceleration time
Creep speed when 0~15.00Hz 0.01Hz 3.00Hz 3
F1.08
door open ends

Door open limit point 1~9999(pulse 1 600 100


F1.09 is set according to
count )
distance

6-9
MPDK136 commissioning manual Code:YETS-0017-C

Door open limit 0.0%~100.0% 0.1% 50.0% 50


torque keeps the
F1.10 setting of switching (related motor
point torque)

When Door is fully 0.0%~100.0% 0.1% 50.0% 50


opened, torque is
F1.11
kept. (related motor
torque)
Door open running 0 : select 1 0 0
curve is selected
manual setting
according to
F1.12 curve
distance
1 : select
self-learning
optimal curve
Door open optimal 3.0 % ~ 15.0 % 0.1% 10.0% 10
F1.13 curve correction
(door width)
factor

F2:Door close running curve parameter group F2


Functional Name Setting range Minimum Default BLT setting
parameter unit value

Door close start creep 10~9999ms 1ms 500ms 500


F2.00 time is controlled by
speed
Door close start creep 0~30.0%(door width) 0.1% 15.0% 0
F2.01 distance is controlled
by distance
Door close start creep 1.00~25.00Hz 0.01Hz 6.00Hz 6
F2.02
speed

Door close 0.1~3600s 0.1s 2s 1.5


F2.03
acceleration time

6-10
MPDK136 commissioning manual Code:YETS-0017-C

Door close high speed 0.00 ~ F0.04 maximum 0.01Hz 15.00Hz 20


F2.04
frequency

Door close high speed 0.00 ~ F0.04 maximum 0.01Hz 20.00Hz 10


F2.05 during the peak
frequency
running

Door close 60%~95%(door width) 0.1% 70.0% 70


deceleration point is
F2.06
set according to
distance.
Door close 0.1~3600s 0.1s 2s 1.2
F2.07
deceleration time

Door close end creep 0~15.00Hz 0.01Hz 2.00Hz 2


F2.08
speed

Door close limit point 1~9999(pulse count) 1 600 100


F2.09 is set according to
distance
Door close limit torque 0.0 % ~ 100.0 % (Related 0.1% 50.0% 50
keeps switching point
F2.10 motor torque)
setting

Door close limit keep 0.0%~100.0%(Related 0.1% 50.0% 50


torque
F2.11 motor torque)

Firefighting door close 5.00~25.00Hz 0.01Hz 10.00Hz 10


F2.12 high speed

Door close running 0:select manual setting 1 0 0


curve is selected
curve
according to distance.
F2.13 1 : select self-learning
optimal curve

Door close optimal 3.0 % ~ 15.0 % ( door 0.1% 10.0% 10


F2.14 curve correction factor
width)
6-11
MPDK136 commissioning manual Code:YETS-0017-C

Door close cam 000~9999 1 800 0


F2.15 collecting point is set
according to distance
Cam restoring speed 0.00~20.00Hz 0.01Hz 5.00Hz 5
F2.16

F9: Monitoring and recording parameter Group F9

Functional Name Setting range Minimum Default BLT


parameter unit setting

F9.00 Running Adopt binary code to select/the bit=1: 1 31 *


display selection display, the specific introduction: (0000
parameter
Bit0:running frequency(Hz) 011111
selection
B)
Bit1: Given frequency(Hz)

Bit2:output voltage(V)

Bit3:output current(A)

Bit4:output torque(%)

Bit5:Direct current bus voltage(V)

Bit6:on-off input terminal state (no unit)

Bit7:On-off output terminal state(no unit)

Bit8:Door position pulse count low bit (0~

9999)

Bit9:Door position pulse count high bit(0~

9999)

6-12
MPDK136 commissioning manual Code:YETS-0017-C

F9.01 Stop display 0:No abnormal record 1 0 *


F9.02 parameter
F9.03 ( blink) 1:Accelerated running overcurrent (E001)
F9.04 The first time 2:Decelerated running overcurrent(E002)
fault type
The second 3 : Constant speed running overcurrent
time fault type (E003)
The third time
fault type 4:Accelerated running overvoltage (E004)

5:Decelerated running overvoltage (E005)

6 : Constant speed running overvoltage

(E006)

9:Output side phase loss (E009)

11:Radiator overheat (E011)

13: Controller overload (E013)

14:Motor protection (E014)

16:EEPROM

Wrong reading and writing(E016)

17:Communication fault reserved(E017)

19:Current detection circuit fault(E019)

24:Tuning error(E024)

25:Encoder error(E025)

26: Overspeed protection(E026)

28:Parameter setting error(E028)

29:Door width self-learning error E029)

30:Door open timeout(E030)

31:Door close timeout(E031)

6-13
MPDK136 commissioning manual Code:YETS-0017-C

F9.05 Bus voltage at 0~999V 1V 0V *


the last fault
time

F9.06 Output current 0.00~99.99A 0.01A 0.00A *


at the last fault
time

F9.07 Running 0.00Hz~128.00Hz 0.01Hz 0.00Hz *


frequency at
the last fault
time

F9.08 Input terminal 0~127(0:OFF;1:ON) 1 0 *


state at the last
CD/OD/X5/X4/X3/X2/X1
fault time

F9.09 Output terminal 0~7(0:OFF;1:ON) 1 0 *


state at the last
PC3/PC2/PC1
fault time

F9.10 Door high level 0~9999(×10000) 1 0 *


at fault time

F9.11 Door low level 0~9999 1 0 *


at fault time

6-14
MPDK136 commissioning manual Code:YETS-0017-C

F9.12 Door opening 0~9999(×10000) 1 0 *


times record
high level

F9.13 Door opening 0~9999 1 0 *


times record
low level

F9.14 Door closing 0~9999(×10000) 1 0 *


times record
high level

F9.15 Door closing 0~9999 1 0 *


times record
low level

F9.16 Work time 0~Maximum timekeeping 65535 hours One hour 0 *


accumulative
total

F9.17 Running time 0~Maximum timekeeping 65535 hours One hour 0 *


accumulative
total
F9.18 Parameter 0:no operation 1 0 ×
initialization
1:Clear memory information
2:Revert factory setting value

F9.19 Software 1.00~99.99 0.01 -


version No.

F9.20 Product 3200~3299 1 -


configuration
No.

F9.21 Radiator 0~100℃ 1 0 *


temperature

6-15
MPDK136 commissioning manual Code:YETS-0017-C

F9.22 Relay output 0:Relay PA1/PC1 and PA2/PC2 is used as 1 0 ×


polarity output often closed contact relay
selection
1:Relay PA1/PC1and PA2/PC2 is used as
ouput often open contact relay.

6.1.7.8 Fault code


Fault code Fault type Fault cause Trouble shooting

E001 Accelerated 1)Acceleration time is too short 1)Lengthen the acceleration


running
2)When instantaneous stop time
overcurrent
happens, restart the rotating 2)Restart after stopping of the
motor. motor
3)Outer connection is wrong 3)Correct connection

4)Pulse encoder wiring is wrong 4)Change the setting of F4.02


and replace wiring phase
sequence of the encoder

E002 Decelerated Deceleration time is too short Lengthen deceleration time


running Adjust PI parameter
overcurrent

E003 Constant 1)Load suddenly changes. Adjust PI parameter


speed running Check the load
overcurrent 2)Load is abnormal.

E004 Accelerated 1)Input voltage is abnormal. Check input power supply.


running Adjust PI parameter.
2)The setting of PI parameter is Externally connect brake
overvoltage
inappropriate. resistance.
3)Load inertia is too large.

6-16
MPDK136 commissioning manual Code:YETS-0017-C

E005 Decelerated 1) Deceleration time is short. 1) Lengthen deceleration time


running 2) Dynamic braking resistance is 2) Reselect brake resistance
overvoltage improperly selected. 3) Check input voltage
3) Input voltage is abnormal. 4) Adjust PI parameter
4) PI parameter is improperly
set.

E006 Constant 1) Input voltage abnormally 1) Install input electric reactor


speed running changes. 2) Externally connect brake
overvoltage 2) Potential load produces resistance
regeneration energy.

E009 Output phase Three phase output Check three phase output
loss disconnection, phase loss or wiring or load symmetry
three phase load is seriously
asymmetric.

E011 Radiator 1) Air flue is blocked 1) Clear the air flue.


overheat 2) IGBT is abnormal. 2) Seek service

E013 Controller 1) Load is too large. 1) Choose adaptive controller


overload 2) Network voltage is too low. 2) Check network voltage.
3) Encoder is abnormal 3) Check encorder wiring or
replace encoder

E014 Motor 1) Related motor current setting 1) Check the setting of F6.03.
protection is wrong. 2) Check the setting of F6.04
2) The setting of maximum 3) Select adaptive motor.
permitted running current is too
small.
3) Motor model selection is
improper.

6-17
MPDK136 commissioning manual Code:YETS-0017-C

E016 EEPROM Reading and writing of parameters Seek service


read and write is wrong
fault

E019 Current 1) Current detection circuit fault Seek service


detection 2) Related power fault
circuit fault

E024 Tuning error 1) Motor nameplate parameter 1) Correctly set the parameter
setting is wrong. according to the parameter of
2) Tuning timeout motor nameplate
2) Confirm if motor is
separated from load or check
motor wiring

E025 Encoder error 1) Encoder signal disconnection 1) Check encoder connection


2) Encoder signal is reversely and reconnect
connected 2) Modify the setting value of
3) Output wiring is wrong or F4.02 (encoder reverse
disconnected (synchronous direction) or change two phase
machine) connection of the motor
3) Check if output connection
is correct.(synchronous
machine)

E026 Overspeed 1) Phase loss of output line 1) Check if output line is


error disconnected.
2) Initial position angle of
synchronous machine is wrong. 2) Check if the synchronous
machine has got correct initial
angle by tuning.

6-18
MPDK136 commissioning manual Code:YETS-0017-C

E028 Parameter 1) When door width self-learning, 1) When door width


setting error door machine panel control mode self-learning, set F0.02 to 1 or
or door machine terminal control F0.02 to 2
mode is not set. 2) When motor parameter
2) When motor parameter tuning, set F0.02 to 0
tuning, 3)Set longer operation time of
general inverter panel control
door open and close to ensure
mode is not set.
F3.01 and F3.02 is more than
3) Open and close limited time is sum of door open-close time
less than open and close time. parameters.
4) Tuning is carried out under 4) Tuning is carried out under
double motor mode. Synchronous single motor mode and F4.11=0
machine controls and operates and actually it only takes one
double motor mode motor. The synchronous
5) When the load of controller is machine is controlled under
synchronous machine and speed single motor mode and F4.11=0
feedback is incremental encoder,
5)When the load of controller is
the setting value of terminal X1
F5.00 is not 0. synchronous machine and
speed feedback is incremental
encoder, the setting value of
terminal X1 F5.00 must be 0.

E029 Door width 1) Door width information from 1) Check impulse encoder
self-learning door width self-learning is 0. connection and related
error 2) Door width information from parameter.
door width self-learning is 2) Check door machine
over-limit. mechanical system
3) Door width self-learning is
timeout

E030 Door opening 1) Motor running direction is 1) Replace motor wiring


overtime error opposite to door opening given phase
direction. sequence or set F0.03 to1
2) Door opening contact signal
2) Check opening contact
fault or wrong setting
signal
3) Impulse encoder disconnection
3) Check encoder wiring

6-19
MPDK136 commissioning manual Code:YETS-0017-C

E031 Door closing 1) Motor running direction is 1) F0.03=1


overtime error opposite to door closing given Replace motor wiring phase
direction. sequence or set F0.03 to 1
2) Door closing contact signal
2) Check door closing contact
fault or wrong setting
signal
3) Impulse encoder disconnecting
3) Check encoder wiring

Door machine controller factory default table, only for checking

Group F0

Parameter
Parameter Factory Parameter Factory Factory
No.
No. default No. default default

Setting is
F0.00 not F0.01 1 F0.02 2
permitted.

F0.03 0 F0.04 24

Group F1

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default

F1.00 500 F1.01 0 F1.02 7


F1.03 1.5 F1.04 20 F1.05 20
F1.06 70 F1.07 1.2 F1.08 3
F1.09 100 F1.10 50 F1.11 50
F1.12 0 F1.13 10

Group F2

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default

F2.00 500 F2.01 0 F2.02 6


F2.03 1.5 F2.04 20 F2.05 10

6-20
MPDK136 commissioning manual Code:YETS-0017-C

F2.06 70 F2.07 1.2 F2.08 2


F2.09 100 F2.10 50 F2.11 50
F2.12 10 F2.13 0 F2.14 10
F2.15 0 F2.16 5
Group F3

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default

F3.00 5 F3.01 300 F3.02 300


F3.03 400 F3.04 100 F3.05 9999
F3.06 10 F3.07 0 F3.08 80
F3.09 300 F3.10 80 F3.15 30
F3.16 115 F3.17 1 F3.18 0
Group F4

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default

F4.00 0 F4.01 1024 F4.02 0


F4.04 5 F4.09 0 F4.10 1
F4.11 0
Group F5

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default
F5.00 0 F5.01 20 F5.05 2
F5.06 3 F5.07 6

Group F6

Parameter Factory Parameter Factory Parameter Factory


No. default No. default No. default
F6.00 1 F6.01 50 F6.02 50
F6.03 1.35 F6.04 150 F6.05 24
F6.06 180

6.2 Ouling door machine electric instruction


6.2.1 Electric connecting

6-21
MPDK136 commissioning manual Code:YETS-0017-C

1) Adopt door machine cable (9 core + PE) to connect the door machine and set box of car
ceiling. Ensure both ends of cable plug well,and ensure the ground wire PE also be installed
well;
2) Door lock accesses safty circuit.
6.2.2 Testing
1) 9 core plug-in stitch definition

Stitch No. Wire No. Connecting position Function Description


1 114 L Door controller input power
AC firewire
2 115 N Door controller input power
AC zero line
3 601 Door controller output Open arrival output signal
terminal
4 602 Door controller output Close arrival output signal
terminal
5 614 Door controller control OPEN command input
terminal signal
6 615 Door controller control CLOSE command input
terminal signal
7 P24 Door controller output Door controller output
terminal signals public terminal
8 616 Door controller control Door controller input signals
terminal public terminal
9 617 empty

9 core plug- in
With door through opening, wire no. of moter machine#2 is different from above, but the function
of stitch no. is same.

2) Testing
a. Short connect 616 with 615. If door machine is not closed fully, it should execute door closing
action; after the door machine is closed fully, the signal input X2 indicator of car ceiling board is
off.
6-22
MPDK136 commissioning manual Code:YETS-0017-C

b. Short connect 616 with 614. If door machine is not opened fully, it should execute door
opening action; after the door machine is opened fully, the signal input X1 indicator of car ceiling
board is off.
c.If both X1 and X2 are all off, need check wiring as drawing.
d. With door through opening, testing way of door#2 is exactly same with above.
6.2.3 For operation way of door machine controller and parameter setting, pls refer to
corresponding products instruction.

6-23
MPDK136 commissioning manual code:YETS-0017-C

7-Self-learning running
7.1 During self-learning running commissioning, first you have to confirm the settings of the
following parameters are right:

F0-03 Running speed 0.250~F0-04


F0-04 Rated speed 0.250~F0-04
F0-05 Rated Load 300~9999
F0-06 Maximum 20.00~99.00
frequency
F0-07 Carrier frequency 8
F3-10 Releveling speed 0.04
F3-11 Inspection running 0.30
speed

The corresponding running speed should be set according to the collateral drawings.
7.2 After above parameters are confirmed right, the following signal connection also need to be
inspected.
7.2.1 Confirm the shaft signal action:
Monitor the signal action in the F5-34 menu of integrated control panel:
When the car runs in the middle of the shaft, all the speed change switches are effective. At this
moment:
Up run, input point X10、X8 disconnect orderly;
Down run, input point X11、X9 disconnect orderly;
(If speed is less than 1.75m/s, do not use X10、X11)

X6 Limit/up Upper limit, signal cut-off


X7 Limit/down Lower limit, signal cut-off
X8 Up level1 strong V1 upper speed change point, signal
reduction cut-off
X9 Down level1 strong V1 lower speed change point, signal
reduction cut-off
X10 Up level2 strong V2 upper speed change point, signal
reduction cut-off

7-1
MPDK136 commissioning manual code:YETS-0017-C

X11 Down level2 strong V2 lower speed change point, signal


reduction cut-off

7.2.2 During inspection running, at the same time, you can observe the door zone signal F5-34
menu action, and make sure whether it is right or not. If any problem appears, solve it
immediately.
7.2.3 Feedback of encoders, leveling sensor is normal (the action is reliable,and the
characteristic parameters of often open/close is set correctly, etc.), forced deceleration switch
mounting distance is correct, feedback is normal;
When the lift is at bottom floor, down level1, down level2 forced deceleration switch acts;
When the lift is under maintenance state and it is controlled by the distance, it is closed-l
oop vector control mode(F0-00=1,F0-01=1);
The highest and lowest floor setting is correct (F6-00 is the highest, and F6-01 is the lowest);

The system is not under state of fault alarm, if any fault, pls press key to restore the current
fault.
7.3 Inspect installation position of forced deceleration switch and limit switch.
The purpose of forced deceleration switch installation: When running speed of the car is a
bnormal and the car runs from the forced deceleration switch position to the end station a
s rated maximum speed, the car can decelerate as specific speed to assure the speed of
car decelerate to zero at the end station, in order to avoid the car squat down bottom, or
header.
Special
Level1 forced deceleration Level2 forced deceleration
Speed m/s deceleration speed
switch distance switch distance
m/s2
0.8-1.0 0.9 0.8-1.0 no
1.5-1.6 0.9 1.6-1.8 no
1.75 0.9 2.0-2.2 no
2 0.9 2.0-2.2 2.5-2.8
2.5 0.9 2.0-2.2 3.7-4.0

Level1 forced deceleration switch and limit switches are mounted on one component, as long as
the limit switch relevels at end station and continue to run to 50mm, it will be installed. Level1
forced deceleration switch position can be guaranteed to meet above table. Level2 forced
deceleration switch is bistable magnetic induction switch. When it relevels at end station, the

7-2
MPDK136 commissioning manual code:YETS-0017-C

distance of magnet point and bistable magnetic induction switch is set as above table.
Direction of the magnetic points are set according to down level2 forced deceleration switch
contacts open through the corresponding magnetic points, and up level2 forced deceleration
switch contacts open through the corresponding magnetic points.
7.4 Start self-learning running: When meet above conditions and under state of inspection, set
operator parameters F1-11 as 3 or keypad F7 as 1, the lift will start self-learning under state of
inspectation.
7.5 Renewal self-learning: When any change occurs in the door zone inspection of shaft or the
position of speed change switch is changed, an effective self-learning must be performed.
7.6 If there is additional leveling board in shaft, need close its absolute floor by
F6-05/F6-06/F6-35.(For an example: There is additional leveling board between floor10 and
floor11. Need to change Bit10 of F6-05 as 0 to close the leveling board).
Because absolute floor changes, need adjust display floor No. Realize adjustment by changing
FE-01 to FE-31, FE-35 to FE-43.For above example, need change FE-10 to 10, FE-11 to 10,
FE-12 to 11, till to the highest floor or the next additional leveling board.

7-3
MPDK136 commissioning manual Code:YETS-0017-C

8 -Debugging operation
8.1 On-site inspection and confirmation
(1) The inspection and confirmation of machine assembling
A. The elevator pit components are installed in good condition. If hydraulic buffer has been used,
confirm the buffer oil is enough as requested; the pit should be dry.
B. There is no barrier in the shaft which can influence the running of the elevator.
C. The landing door is installed in good condition.
D. Good sealing between landing door upright and door opening.
E. The installation of guide rail has been approved qualified.
F. The installation of steel rope is correct and tight.
G. The installation and fixing of all sorts of switches.
H. The tension sheave of speed governor steel rope has been installed correctly.
I. The installation of car is complete, consolidate and tighten.
J. The traveling cable has been installed and fixed in good condition.
K. The positioning of machine room components comply with the national standards.
L. The fixing of main machine complies with the requirements of factory installation, and the
main machine beam should be fixed and sealed (concealed work) good.
M. If it is equipped with gear traction machine, confirm the oil in reduction gearbox is enough.
N. Confirm the encoder on the main machine is fixed firmly.
O. The positioning of speed governor is satisfied the national standards.
P. The wire duct is laid in order, and they should be connected by copper sheet and yellow green
wire.
Q. The installation and positioning of control cabinet is in order.
R. The machine room and shaft should be kept clean.
S. The leveling sensor flashboard in every floor of shaft should be installed correctly.
T. The car door operator is installed correctly.

8-1
MPDK136 commissioning manual Code:YETS-0017-C

(2) The inspection and confirmation of electric assembling

WARNING
Any problem occurs during the process of the following inspections should be
checked and solved carefully. Make sure that there is no influence on equipments
and people.

A. The wiring of door operator should be correct; the wiring of infrared curtain should be correct.
B. The wiring of car top leveling sensor should be correct, and ensure the installation dimension
is correct and firm.
C. Every safety switch in the shaft could act effectively.
D. The installation position of upper and lower inspection switches in the shaft should be correct,
and the action of switch is effective.
E. The wiring of interphone is correct, and ensures the call is normal.
F. The wiring of arrival gong is correct. (Skip this step if there is no arrival gong)
G. The wiring of external calling box is reliable and correct.
H. The wiring of car lighting and fan is correct.
8.2 Riding Comfort
The riding comfort is an important factor of the elevator's overall performance. Improper
installation of mechanical parts and improper parameter settings will cause bad comfort.
Enhancing the riding comfort mainly involves adjustment of the controller output and the
elevator's mechanical construction.
Controller output controls relevant parameters:

Function Parameter
Setting Range Default Description
Code Name

It can reduce the lower- frequency vertical jitter


Current filter
F1-09 0.00~40.00 0.00 during running.
coefficient

Empty load Increasing the value can improve the loading


F1-18 0.01~300.00 0.00A
current capacity of asynchronous motor.
Speed loop F2-00 and F2-01 are the PI regulation parameters
F2-00 proportional gain 0~100 50 when the running frequency is lower than
KP1 F2-02(switchover frequency 1). F2-03 and F2-04
are the PI regulation parameters when the running
Speed loop
F2-01 0.01~10.00s 0.50s frequency is higher than F2-02(switchover
integral time1
8-2
MPDK136 commissioning manual Code:YETS-0017-C

Function Parameter
Setting Range Default Description
Code Name

Switchover frequency 2). The regulation parameters between


F2-02 0.00~F2-05 2.00Hz
frequency 1 F2-02 and F2-04 are the weighted average value
of F2-00&F2-01 and F2-03&F2-04.
Speed loop
F2-03 proportional gain 0~100 50
KP2
Speed loop
F2-04 0.01~10.00s 0.50s
integral time2
Switchover
F2-05 F2-02~F0-06 5.00Hz
frequency 2

Regulating method:
For a faster system response, increase the proportional gain and reduce the integral
time.Be aware that a fast system response causes system oscillation. The recommended
regulating method is as follows:
If the default setting cannot satisfy the requirements, make slight regulation. Increase the proportional gain
first to the largest value under which the system does not oscillate. Then decrease the integral time to ensure
fast responsiveness and small overshoot.
If both F2-02 (Switchover frequency 1) and F2-05 (Switchover frequency 2) are set to 0, only F2-03 and F2-04
are valid.

Current loop
F2-06 10~500 60
proportional gain F2-06 and F2-07 are the current loop adjustment
Current loop parameters in the vector control algorithm.
F2-07 10~500 30
integral gain
Regulating method:
The optimum values or these two parameters are obtained during motor auto-tuning and you need not modify
them. Appropriate setting of the parameters can restrain jitter during running and have obvious effect on the
riding comfort.

Startup
F2-18 acceleration 0.000~1.500 0.000s
time It can reduce the terrace feeling at startup caused
0.000~ by the breakout friction of the guide rail.
F3-00 Startup speed 0.000m/s
0.030m/s
Startup holding
F3-01 0.000~0.500s 0.000s
time

Zero-speed It specifies the zero speed holding time before


F3-18 output time at 0.000~1.000s 0.200s brake output.
startup

8-3
MPDK136 commissioning manual Code:YETS-0017-C

Function Parameter
Setting Range Default Description
Code Name

Break opening 0.200s It specifies the time required when break is


F3-19 0.000~1.000s
time 0.600s opened completely.
Break release It specifies the time required when break is
F3-20 0.000~1.000s 0.300s
time released completely.
Stop torque The holding time of zero speed after break is
F8-11 0.200~1.500s 0.200s
output delay released.

The release time of the brakes varies and response time of the brakes is greatly influenced by the
ambient temperature. (A high brake coil temperature slows the brake responsiveness. )Thus, when the
riding comfort at startup or stop cannot be improved by adjusting zero servo or load cell compensation
parameters, appropriately increase the values of F3-19 and F3-20 to check whether the brake release time
influences the riding comfort.

0: Pre-torque
invalid
1: Load cell
pre-torque Set this parameter based on actual requirement,
Pre-torque
F8-01 compensation 2 generally,set to 2, no need adjust below
selection
parameters.
2:Automatic
pre-torque
compensation
Zero servo
F2-11 current 0.20%~50.0% 15.0%
coefficient These are zero-servo regulating parameters when
Zero servo F8-01 is set to 2 (Automatic pre-torque
F2-12 0.00~2.00 0.50 compensation).
speed loop Kp
Zero servo
F2-13 0.00~2.00 0.60
speed loop Ki
8-4
MPDK136 commissioning manual Code:YETS-0017-C

Function Parameter
Setting Range Default Description
Code Name

a. Gradually increase F2-11 (Zero servo current coefficient) until that the rollback is cancelled
at brake release and the motor does not vibrate.
b. Increase the value of F2-11 (Zero servo current coefficient) if the motor jitters when F2-
13 (Zero servo speed loop TI) is less than 1.00.
c. Motor vibration and acoustic noise indicate excessive value of F2-12 (Zero servo speed loop KP). Use the
default value of F2-12.
d. If the motor noise is large at no-load-cell startup, decrease the values of the zero servo current loop
parameters (F2-14 and F2-15).

F8-02 Pre-torque offset 0.0%~100.0% 50.0% Load pre-torque regulating parameters. No need to
F8-03 Drive gain 0.00~2.00 0.60 regulate it as current standard products.

F8-04 Brake gain 0.00~2.00 0.60


Load cell pre-torque compensation: the system with a load cell pre-outputs the torque matched the load to
ensure the riding comfort of the elevator.

Motor driving state: full-load up, no-load down

Motor braking state: full-load down, no-load up

"Pre-torque offset" is actually the elevator balance coefficient, namely, the percentage of the
car load to the rated load when the car and counterweight are balanced.

"Drive gain" or "Brake gain" scales the elevator’s present pre-torque coefficient when the
Startup pre-torque compensation is higher. The controller identifies the braking or driving.

state according to the load cell signal and automatically calculates the required torque compensation
value.
When an analog device is used to measure the load, these parameters are used to adjust the elevator
startup. The method of adjusting the startup is as follows:
In the driving state, increasing the value of F8-03 could reduce the rollback during the elevator startup, but a
very high value could cause car lurch at start.
In the braking state, increasing the value of F8-04 could reduce the jerk in command direction during the
elevator startup, but a very high value could cause car lurch at start.

Mechanical Construction
The mechanical construction affecting the riding comfort involves installation of the guide rail,
guide shoe, steel rope, and brake, balance of the car, and the resonance caused by the car,
guild rail and motor. For asynchronous motor, abrasion or improper installation of the gearbox
may arouse bad riding comfort.
1. Installation of the guide rail mainly involves the verticality and surface
8-5
MPDK136 commissioning manual Code:YETS-0017-C

flatness of the guide rail, smoothness of the guide rail connection and parallelism between
two guide rails (including guide rails on the counterweight side).
2. Tightness of the guide shoes (including the one on the counterweight side)
also influences the riding comfort. The guide shoes must not be too loose or tight.
3. The drive from the motor to the car totally depends on the steel rope. Large flexibility of
the steel rope with irregular resistance during the car running may cause curly oscillation of
the car. In addition, unbalanced stress of multiple steel ropes may cause the car to jitter
during running.
4. The riding comfort during running may be influenced if the brake arm is
installed too tightly or released incompletely.
5. If the car weight is unbalanced, it will cause uneven stress of the guide shoes that
connect the car and the guide rail. As a result, the guide shoes will rub with the guide rail
during running, affecting the riding comfort.
6. For asynchronous motor, abrasion or improper installation of the gearbox may also
affect the riding comfort.
7. Resonance is an inherent character of a physical system, related to the
material and quality of system components. If you are sure that the oscillation is caused
by resonance, reduce the resonance by increasing or decreasing the car
weight or counterweight and adding resonance absorbers at connections of the
components (for example, place rubber blanket under the motor).

8-6
MPDK136 commissioning manual Code:YETS-0017-C

9-Supporting function to confirm


9.1 Full collective selective control
When elevator runs automatically, it responds to the signals from every landing call in the up and
down direction and car call. The passengers can register the up and down signals to call the
elevator. (see FE-00 Parameter)
9.2 Door opening time setting
According to the setting time, the system can automatically judge different door opening holding
time, such as call opening, command opening, door protection opening, delay opening.
Fb-11 Hall call door opening holding
Fb-12 Car call door opening holding
Fb-13 Main floor door opening holding
Fb-14 Door opening holding time
Fb-15 Special door opening holding
9.3 Service floor setting
The system can choose to close or activate some or several servie floors according to
demands.(see the manual 4.8.6 for the details)
9.4 Time-sharing service
The system can set time-sharing service time and time-sharing service foor flexibly.(see the
manual 4.8.7 for the details)
9.5 Pre-close button
When the elevator runs automatically and keep the door opening, it can be pre-closed by the
button to improve efficiency.
9.6 Light curtain protection
When the light curtain is covered, the door will open again. Doors will not close whilst obstruction
in the way. But the light curtain dose not work while fire fighting.
9.7 Energy saving lighting in the car
If no call or call registration is registered after F9-01 manual setting time (normal three minutes),
car light are automatically shut off. If call is received, light are switched on again.
9.8 Energy saving fan in the car
If no call or call registration is registered after A1-03 manual setting time (normal three minutes),
the fan are automatically shut off. If call is received, the fans are switched on again.
9-1
MPDK136 commissioning manual Code:YETS-0017-C

9.9 Door auto-open when lock fault


When door open or close, if the lock is detected to have a fault, the elevator will open or close
the door automatically. The falult feedback will be shown after several times of door open or
close.
9.10 stop at the next station
If the elevator continues to keep opening after opening protection time, the signal is invalid, the
elevator will close and then automatically register the nearest landing and arrive there.
9.11 Call respond while accelerating
The system allows calls while acceleration, and automatically responds to corresponding service
floor instruction.
9.12 In car Fault Command Cancellation
Fault command can be cancelled by continuously pressing the fault command twice before the
elevator start. (FE-32 parameter Bit11、Bit12)
9.13 Attendant travel
In the car, switch the attendant on for operation.
When there is the attendant, if hall calls, the indicator in the car is on; but if call limitation, the
attendant in the car can choose corresponding landing. Change F6-43 for attendant setting.
9.14 slow speed self-help
When the elevator is on inspection status and doesn’t stop at the leveling zone, the elevator will
move to the leveling zone with slow speed as long as it meets the safty requirements of starting.
9.15 Button adhesion diagnosis
The system can recognize hall call buttons adhesion and cancel the adhensive call automatically,
and avoid the elevator can not close the door due to the adhesion of the hall call button. (see
FE-32 parameter parameter Bit4)
9.16 Load compensation function
Before the elevator moves, the weighing device checks the car with to make the starup more
stable and comfortable.(See manual 8.2)
9.17 dirct stop
Automatically calculate to produce operation curve based on distance and directly stop at
leveling location.

9-2
MPDK136 commissioning manual Code:YETS-0017-C

9.18 Produce the best curve automatically


Based on the distance, automatically produce the speed curve most suitable for the principle of
people and computer function
9.19 numbers of running record
Under automatic running status, the elevator can record the number of running automatically.
F9-11 High bit of running No.
F9-12 Low bit of running No.
9.20 Running time record
Automatically record the actual running time. F9-09 is accumulative running time.
9.21 VIP running
In the car, switch VIP on, then the function of VIP is valid.
When VIP function is running, all landing call signals are canceled, elevators only respond to the
car call.
9.22 Overload indicator
When car load exceeds 100% loading, overloading swich is on and the indicator is on.
Detect over-load signal, when the elevator stops. When the elevator is over-load, it stops
running and keep door opening.
9.23 Full car bypass indicator
Landing indicator shows it is in the state of bypass.
9.24 Full car bypass
When under full load, elevator does not respond to hall call signals from the passing floor and
only respond to the car call signals. But hall call can still be registered, it will be responded next
time by it (simplex), or the other elevator (group control).
9.25 Electronic load weighing device :
An electronic weighing device, which accurately measures the car capacity. (see chaper12 for
the details)
9.26 Non-door opening zone protection
If the system detects landing door or car door to be opened already and elevator is at the
non-door opening zone, the elevator will stop travelling.
9.27 Fault history record
The system can record the fault details to improve the efficiency of mantainence. (FC-20 to

9-3
MPDK136 commissioning manual Code:YETS-0017-C

FC63 is fault record)


9.28 Easy maintainence keyboard
Commissioning can be done by the keyboard of control panel, and achieve the function of
running floor, door opening and closing.
9.29 Car debugging
Debugging personnel can connect system and debug to improve efficiency by operator in the
car.
9.30 Learning function
Use the learning function of the system to check data of well (hall height, protection switch
location, slow-down switch location etc.) and save these data permanently before the elevator
starts traveling. (see chaper 7 for details)
9.31 Inspection travel
When the elevator is on inspection status, the system cancels automatic travel and automatic
door operation. Push up or down going button, the elevator will travel slowly as inspection
speed.
9.32 Motor parameters tuning
System can be set through simple parameters, and in the case of with or without load complete
relevant control parameters of learning.(See chapter 5 for details)
9.33 Floor location intelligent correction
When the elevator travels to the terminal stop each time, the system automatically according to
the first level forced slow -down switch to check and correct the location of cars, and with force
reduction system to eliminate crouch or header.
9.34 Fire emergency travel
The signal comes from the fire sensor or other detection devices in building. When control
system is actuated by fire signal, each elevator shall return to the designated fire escape floor
immediately and park with doors open. F6-03, for firefight floor change.
9.35 Fireman service operation
When fireman's switch is set (non-inspection), the elevator shall return to firefighting main floor.
All calls are cancelled. If elevator is traveling in opposite direction, it should stop at the nearest
landing with doors close. Then it shall return to the main floor with doors open. Only register the
internal command signal. Doors do not automatically close while in fire service.

9-4
MPDK136 commissioning manual Code:YETS-0017-C

When firman signal is off, the elevator must return firefight floor, after open door, the fireman
state is ended.
9.36 Fireproof No Admittance indication
During the fire and when the elevator is in fire landing, No Admittance indicator lights.
9.37 Firefight feedback
When elevator receives the fire alarm signal or fireman service signal, it will return to the firefight
floor and Output the signal.
9.38 Fire emergency travel indication:
During fire emergency travel, travel indicator shows the elevator is in fire emergency travel.
9.39 Lock service
In full automatic travel, if the lock switch is actuated, the elevator return to home landing foor,
and stop travelling.
9.40 Fault resolving as classification
According to the degree of the influence of fault, the system classify the fault information,
adopt different revolution correspondingly and to improve the efficiency of system operatio
n.
9.41 Overspeed prohibition
Elevator detects elevator running state, if it overspeeds, immediately stop traveling to brake the
elevator.
9.42 Terminal inspection
After the system detects abnormal location, the elevator travels to the terminal to inspect to
assure safety of system.
9.43 Put the people preferentially
The elevator automatically classifies the fault and returns the landing floor to evacuate the
passengers preferentially on the premise of safety.
9.44 Interference evaluation
The elevator evaluates communication signal transmission interference, reflects the current
degree of interference.(See FA-24 parameter)
9.45 Light load anti-nuisance function
The number of car calls registered at the same time is limited during light load.
A1-05 set the function, which can register number of foors.
9.46 Current slope to removal
During the application of the permanent magnet synchronous motor, after running slowly and
9-5
MPDK136 commissioning manual Code:YETS-0017-C

stop, the maintaining current of the motor is removed by means of a slope, avoid the abnormal
noise of the motor.
9.47 Intercom(alarm system)
Intercom button on the car operation panel, a five way communication device linking the top of
the car, the car, the pit, the machine room, and the surveillance room.
9.48 Alarm bell
When the elevator malfunctions or power is off, pushing the alarm bell button will sound the
alarm in the well, machine room or hall.
9.49 Data copy
To upload and download control system parameters by a manipulator.(See the manual 4.8.10
for details.)
9.50 User setting inspection
By the function, check the parameters that the system sets are inconsistent with factory sets.
Set 1 for FP-02, to check the parameters that the current value is different from the default
value.
9.51 Special display:
The system is able to set the display pattern if abnormal landing floor sequence is requested by
the customer. (See FE for relevant parameters.)
9.52 Hall call registration and memory display:
When the hall call button is pushed, the button illuminates for call accepted. The elevator will
start traveling.
9.53 Travel direction and floor display
Car operating panel and hall call board have a display for the floor in which the elevator is and
current travel direction.
9.54 Door open with floor button
When the car door is closing or has been closed, and elevator doesn’t start, push the button on
this floor, the car door will be opened automatically.
9.55 Call reversal registration
The call will be registered if the call direction of this floor is not in the travel direction.
9.56 Anti-stall protection
The elevator will stop when hoist rope slippage is detected.
9.57 Program run WDT protection
WDT detects continuously if the program runs incorrectly, and all output resetting system will be
cut out when mistakes are found.
9.58 Power failure data holding
All running data will be saved when power cut.
9.59 Automatic main floor returning

9-6
MPDK136 commissioning manual Code:YETS-0017-C

Under automatic travel, the elevator will return to the main floor waiting if there is no car call or
hall call for a period of time. The elevator will respond to any call immediately during the process
of returning to the main floor.
Data F9-00, is return time. 0 is invalid.
9.60 Emergency car lighting supply
Emergency lighting on the car operation panel will turn on automatically during power cut.
9.61 Landing Indicator
Landing indicator shows the (inspection) status of elevator.
9.62 Door interlock safety protection
Under automatic travel, elevator would stop and send out alarm message when system found
the safety circuit of door interlock break. The elevator will operate only after the fault is
eliminated.
9.63 Brake monitoring function
The system automatically monitors the working condition of the brake to ensure reliable
operation of the brake.
9.64 Duplex control:
Two elevators travel under duplex control. When one of two elevators can not respond to the call
in case of fault, it will separate from duplex control and travel independently, and do not affect
the normal travel. (See chapter 10 for details)
9.65 Group control function :
Group control function can control 3-8 elevators. When one elevator can not respond to the call
in case of fault, it will separate from group control and travel independently, and do not affect the
normal travel.
When the group control fails or group control communication fails, the separate elevators service
function is available.(See manul chapter14 for details)
9.66 Decentralized off line function
In group control, when the passenger flow volume is reduced, each elevator is stacked on
various floors in order to respond in time when there is call, and reduce the waiting time.
9.67 Rush hour service
During set peek time, if the car call is more than 3 from peak floor, then rush hour servi
ce begins, the car calls of the peak floor are available , when the elevator is free it will r
eturn the floor. This function can set two independent peak time.(See data F6-26~F6-31)
9.68 Preferential landing service
Elevator will send the nearest car to the calling floor, while responding to the call.
9.69 Light curtain and safety edge protection
When the light curtain and safety edge operate, the door will open again.
9.70 Door nudging
Door opens when elevator receives any block between the infrared curtains. If the blockage is
over set time, door will close smoothly with buzzing.
9.71 Car arrival chime
9-7
MPDK136 commissioning manual Code:YETS-0017-C

When elevators arrive at the destinated floor, arrival chime will give the signals from the car
ceiling.
9.72 Car arrival chime cancels at Night
During the set time, the function of car arrival chime will be cancelled at night.(See F5-33
parameters Bit4)
9.73 Earthquake emergency travel
When the seismic sensors are actuated, all elevators will stop promptly at the nearest available
floor and park there with doors open.
9.74 Emergency leveling device when power cut
When the system starts,it detects the current power supply for backup battery power supply.
According to the load, the system determins leveling floor direction. As F8-09 (blackout
emergency rescue speed) speed, the elevator arrives at the leveling floor and keeps the door
openning, and can't start again. If the time through two floors is more than A1-07 set time E30,
elevator can't run.
9.75 Emergency power operation transfer device
A standby power transfer device is provided.
9.76 Emergency power supply function
Emergency power supplys, the elevator runs to the landing floor and keep door opening (A1-01
Bit8 is 0)or after arrive at landing floor continues to travel.
9.77 Voice announcement system
Voice announcement system sounds to indicate the arrival of car to passengers.
9.78 Background music function
Car background music provided when elevator is operating. (See chapter 16 for details)
9.79 Pre-open
When the elevator runs automatically, elevator starts to open the doors before leveling to make
the elevator high efficiency. Set FE-32 Bit3 for the function. (See chapter 11 for details.)
9.80 Automatic re-leveling
The elevator stops, and sometimes load changes will affects leveling,or because of the sicks,
inconvenience will be brought to passengers and goods in and out, then system allows with door
opening to run to leveling position as leveling speed
FE-32 Bit2 is releveling function start option. ( See Chapter11 of manual for details.)
9.81 Landing Light
The landing lights will indicate the arrival of the elevator.
9.82 Security floor function
The function is available from pm 10 to am 6.The elevator will arrive at security floor firstly and
open door,before arrive at the destinated floor, which will improve security.The security floor can

9-8
MPDK136 commissioning manual Code:YETS-0017-C

be set by F6-13, and set FE-32 Bit5=1 to activate the function from 22.00 to 6.00.
9.83 Video supervisory electronic camera
An electronic camera is mounted in the car monitoring lift car activity.
9.84 Video camera pre-interface
Coaxial communication cable is included in traveling cable.
9.85 Automatic lock
To set automatic lock time, the elevator can lock or unlock automatically.
F6-40 Bit5 set 1, start. Set 0, close.
F6-38 start time of lock
F6-39 finish time of lock
Set locking time period: lock automatically during this period. But F5-34 dose not display the
status.
9.86 The other functions required in contract should be tested.

9-9
MPDK136 commissioning manual Code:YETS-0017-C

10-Debugging of Duplex Control


10.1 Integral machine control system has duplex/group control function, which is implemented
by using the CANbus communication port for information exchange and processing between the
two elevators.It also supports group control of three to eight elevators if a group control board
is used. This implements coordination between multiple elevators to respond to hall calls and
improves the elevator use efficiency.
Different ports implement duplex/group control setting.

Three communication interfaces implement duplex/group control parameters setting.


Functio Default Value
Implication Setting Range Duplex/group control setting
n Code
Group Set according
F6-07 1~8 2
control no. to contract

Master elevator: 1 Set according


F6-08 Lift No. 1~8 to contract
Slave elevator: 2

Bit2: Duplex/group 0
control Bit2 = 1 when CN5 of the
implemented at RS232 communication port is used for
monitoring port duplex/group control
Progra
m
F6-09 control Bit3: Duplex/group Bit3 = 1 when CN4 of the CAN2 1
selectio control implemented at communication port is used for duplex/group
n CAN2 control

Bit4: Duplex/group control Bit4 = 1 when the NICE3000 is involved in 0


in compatibility parallel/group control

The product in duplex control only uses CAN2 communication of duplex control, pls do not
change F6-09 parameters in the list.

Note

When the CAN2 communication port is used for parallel control, you need not set the CTB
address switch.

Use CAN2 communication interface (CN4 terminal) for duplex/group control.


This mode can be implemented by directly connecting the CN4 terminals of two elevators and
setting related parameters of group F6. You need not set the CTB addresses. Wiring sketch is as
following, when CAN2 is used for parallel control.

10-1
MPDK136 commissioning manual Code:YETS-0017-C

LIFT 1# LIFT 2#
Main Controller Main Controller
CAN cables for duplex control

LIFT 1# LIFT 2#
CTB CTB

Up button indicator

HCB HCB
Up button

Down button

Down button indicator

Duplex/group control floor address setting


Physical floors, relative to the NICE control system, are defined by the installation position of
the leveling plate. The floor (such as the ground floor) at which the lowest leveling plate is
installed corresponds to physical floor 1. The top physical floor is the accumulative number of
the leveling plates. In parallel mode, the physical floor numbers of the same floor for two
elevators are consistent.
If the floor structures of two elevators are different, physical floors should start with the floor with
the lowest position. The physical floors at the overlapped area of the two elevators are the same.
Even if one elevator does not stop a floor in the overlapped area, a leveling plate should be
installed there. You can make the elevator not stop at the floor by setting service floors.When
two elevators are in parallel mode, the addresses of the HCBs should be set
according to physical floors. Parallel running can be implemented only when the HCB
address set for one elevator is the same as that for the other elevator in terms of the same floor.

Note:In parallel mode, the top floor (F6-00) and bottom floor (F6-01) of the elevators should be
set based on corresponding physical floors.
10-2
MPDK136 commissioning manual Code:YETS-0017-C

Assume that there are two elevators in parallel mode. Elevator 1 stops at floor B1, floor 1, floor 2,
and floor 3, while elevator 2 stops at floor 1, floor 3, and floor 4. Now, you need to set related
parameters and HCB addresses according to the following table.

Parameter setting and HCB addresses of two elevators


Lift#1 Lift#2
No. of elevator in
group control 2 2
mode(Fd-00)
Elevator No.
1 2
(Fd-01)
Physic HCB
Actual
al addres HCB display HCB address HCB display
Floor
Floor s
B1 1 1 FE-01=1101
1 2 2 FE-02=1901 2 FE-02=1901
None-stop floor but
2 3 3 FE-03=1902 leveling plate required FE-03=1902

3 4 4 FE-04=1903 4 FE-04=1903
4 5 5 FE-05=1904
Bottom floor
1 2
(F6-01)
Top floor
4 5
(F6-00)
Service floor 65531(not stop at physical floor 3)
65535
(F6-05)

10-3
MPDK136 commissioning manual Code:YETS-0017-C

11-Pre-open/ Releveling function set


11.1 Leveling board installation instruction
1. Leveling switch installation instruction diagram ( left: no pre-open releveling function; right:
pre-open or releveling function)

2. Installation Reqirement
A. When the elevator levels, levling switch is in the middle of leveling boards.
B. The up/down leveling switch is equal distance to the middle leveling switch.
C. The up leveling switch is 10mm to the upper edge of leveling board.
D. The down leveling switch is 10mm to the lower edge of leveling board.
E. The vertical center lines of up/down/middle leveling switch coincide.
11.2 Relevling switch act sequence
When the elevator stops normally, up/down/middle leveling switches are in the leveling board.
Due to some reason, when the up leveling switch separates from the range of leveling board, the
elevator runs down as relevling speed, till the up/down/middle leveling switches are in the
leveling board, the elevator stops. By adjusting the distance between the up/down leveling
switches and upper/lower edges to leveling board and releveling speed, leveling precision of
elevator will be controled in a reasonable range.
11.3 Relevant parameters setting
Set FE-32 Bit3 as 1 , start pre-open function, set it as 0, close.
11-1
MPDK136 commissioning manual Code:YETS-0017-C

Set FE-32 Bit2 as 1, start releveling function, set it as 0, close.

11-2
MPDK136 commissioning manual Code:YETS-0017-C

12 Load weighing device installation and debugging


12.1 Electronic load weighing device debugging (for removable car floor)
1. Controller terminals function

(1)1、2 controllers 24V power,1,+、2,-


(2)2、4 overload relay contact(off –contact when over-load)
(3)5、6 full-load relay contact(closing –contact when full-load)
(4)7、8 light- load relay contact(off-contact when light- load)
(5)9、10 internal output 0~10V voltage signal

2. Load weighing device installation

1)Under the state of empty load, install the magnet on the bracket, and keep its logo side
up.
12-1
MPDK136 commissioning manual Code:YETS-0017-C

2)By bolt M3 fasten the controller on the bracket, and fasten the bracket on the removable
car floor, which is opposite to the magnet. Make the induction center of controller be
opposite to the center of induction magnet, and assure the logo of magnet is right opposite
to the logo of controller and keep the controller and magnet parallel.
3)Adjust the controller to make inspection gap 15-17mm. During installation, if location is
wrong, one of two position indicators is on. If the up indicator ⑴is on, the controller need to
be adjusted down. If the down indicator⑵ is on, the controller need to be adjusted up. If
the position is right, both two indicators are off. (Because we install Load weighing device
reversedly to car floor, up and down indicators are opposite to adjust direction.)
3.Debugging
1).Install the controller on the car floor. Supply power under empty load status. Digital
device Indicates “821”.
2).Elevator empty load cleared. Continuously press the cleared button for 3 times. The
indicator ⑶ is off with 3 light sounds. After around 5 seconds, three long sound responds
are heard. And the indicator ⑶ is on. Zero learning is finished, and digital device indicates
“000”.
3 ) .Increase load to the demand light-load (the default should be set to 225 kg),
continuously press cleared button for 5 times in 5 seconds, and the indicator (3)is off with
5 short sounds. After 5 seconds one long sound is heard, and the indicator(3)is on again.
Light- load learning is finished. (This can not be done if no light-load).
4).Increase load weight to value of over-load, and press cleared button for over 5 seconds.
The indicator (3)is off with one short sound. When one short and one long sound respond
is heard, the indicator (3)is on again. Full load learning is finished, digital device indicates
“100”.
4.Controller instruction
1)When self-learning operation, the dicator ⑶ is off. The indicator ⑶ is on again,
when operation finishes. Only with the indicator ⑶ is on, next learning operation can be
done.
2)When self-learning , if during the process of the indicator ⑶ from off to on, no correct
responds of operation is heard, then the operation fails, need to re-learn the operation.
3)Self-study is completed, and the controller operates normally, and then the indicator
⑵and ⑶ are on. Commissioning is completed, and the controller can work normally.
When the load weight of car ranges from empty load to full load, the controller outputs
0~10V or 0~10mA. Digital device displays from 000 to above 102 and when load
weight reaches set light- load, light load relay acts. When load weight reaches 95% of
full load, full-load relay acts. When load weight reaches to 102% of full load, overload
relay acts.
5. Controller maintainence
After controller normal work, the controller should be inspected every month. Study
whether the controller digital device display varies with load weight. The controller
should be inspected and maintained every three monthes (90 days) as the following
procedures.
1) Inspect whether the controller’s installation piece is loose, and fasten it.
12-2
MPDK136 commissioning manual Code:YETS-0017-C

2)Inspect controller over-load function: The elevator stops at bottom floor. Cut off the
power of controller, and inspect whether the elevator receive over-load signal. If the
elevator does not receive over-load signal, pls check circuit or change the weighing
controller.
3)After above two steps, stop elevator at the bottom floor and do cleared operation.
4)With a certain load to the elevator, inspect whether the controller display is within the
normal range. Such as 800 kgs elevator with 100 kg load weight, if its digital control
device display between 8% -14%, controller is normal. If not within this range, check
whether the rubber block is aging, and re-learn as the following debugging instruction.
12.2 Load weighing device debugging (for Rope head device)
1.Controller terminal function (as Diagram 1)

Diagram 1.Controller terminal function


2. Connect

Connect sensor with controller by supplied special cables. (the special cable is as diagram
2.)

Diagram 2

12-3
MPDK136 commissioning manual Code:YETS-0017-C

3.Debugging
a.Device initial check
Set switch in the ‘running' position, the controller is powered and utters a long sound. The
digital device indicates 888, and then shows the percentage of the elevator load (if it utters
three ring sounds after it is powered, inspect whether the sensors and connecting cable is
connected to the controller. If it is connected, inspect the sensor and connectting cable).
The percentage of elevator’s load weight increases as the elevator load weight increases.
b. learning
①The device is powered, and warm up for 10 minutes.
②Empty load elevator stops at the lightest self-weight floor, on which floor the sensor has
minimum force and dose cleared learning. Continuously press the cleared button for three
times within three seconds, with three light sounds and then three long respond is heard.
The digital device indicates 000, cleared (tare) is completed.
③ After cleared (tare), on the heaviest self-weight floor, with 99% rated load, and starts
full-load learning. Press cleared button for above 5 seconds, and release immediately after
one long sound is heard. The digital device indicates 099-100.
④Debugging is completed.
Special remark: When weighing data is more than 80%, the system considered it as
full-load .when more than 100%, as over-load.

12-4
MPDK136 commissioning manual code:YETS-0017-C

13 Fault description
Fault information and troubleshooting
If an alarm of integral machine is reported, the system performs corresponding processing
based on the fault level. You can handle the fault according to the possible causes
described in the following table.

Fault Name Possible causes Solution Level


code
1. Check whether the RUN contactor at the controller
1.The main circuit
output side is normal.
output is grounded or
2. Check.
short circuited.
•Whether the power cable jacket is damaged
Over-current 2. Motor auto-tuning is •Whether the power cable is possibly short circuited to
during performed improperly.
Err02 ground 5A
acceleration 3. The load is too • Whether the cable is connected reliably
heavy. 3. Check the insulation of motor power terminals,
4. The encoder signal and check WHETHER the motor winding is
is incorrect. short-circuited or grounded.
4. Check whether the shorting PMSM stator
contactor causes controller output short circuit.
1. The main circuit 5. Check whether motor parameters comply with the
nameplate.
output is grounded
or short circuited. 6. Perform motor auto-tuning again.
7. Check whether the brake keeps released before the
2. Motor fault occurs and whether the brake is stuck
auto-tuning is mechanically.
Over-current performed 8. Check whether the balance coefficient is correct
during improperly.
Err03 9. Check whether the encoder wirings are correct. For 5A
deceleration 3. The load is too asynchronous motor, perform SFVC and compare the
heavy. current to judge whether the encoder works properly.
4. The 10. Check:
deceleration rate is
• Whether encoder pulses per revolution (PPR) is
too short. set correctly
5. The encoder
• Whether the encoder signal is interfered with
signal is incorrect.
• Whether the encoder cable runs through the duct
independently
• Whether the cable is too long
1. The main circuit
output is grounded • Whether the shield is grounded at one end
or short circuited. • 11. Check whether:
2. Motor • Whether the encoder is installed reliably
auto-tuning is • Whether the rotating shaft is connected to the
Over-current performed motor shaft reliably.
Err04 at constant properly. 5A
• Whether the encoder is stable during
speed 3. The load is too normal-speed running
heavy.
12. Check whether UPS feedback is valid in the
4. The encoder is non-UPS running state (Err02).
seriously interfered
13. Check whether the acceleration/ deceleration rate
with.
is too high (Err02, Err03).

13-1
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code

1. The input 1. Adjust the input voltage. Observe whether the bus
voltage is too high. voltage is normal and whether it rises too quickly
2. The during running.
regeneration 2. Check for the balance coefficient.
power of the motor 3. Select a proper braking resistor and check whether
Over-voltage is the resistance is too large based on the
during too high. recommended braking resistance table in chapter 3.
Err05 5A
acceleration 3. The braking 4. Check:
resistance is too • Whether the cable connecting the braking resistor
large, or the is damaged
braking unit fails.
• Whether the cooper wire touches the ground
4. The acceleration
rate is too short. • Whether the connection is reliable

1. The input
voltage is too high.
2. The braking
Over-voltage resistance is too
during large, or the
Err06 5A
deceleration braking unit fails.
3. The
deceleration rate is
too short.

1. The input
voltage is too high.
Over-voltage 2. The braking
Err07 at constant resistance is too 5A
speed large, or the
braking unit fails.

1. Check whether the external power supply is


stable and whether the wiring of all power input
Pre-charge 1. The external cables is secure.
relay not power supply is 2. Forbid frequently powering on the controller on
close instable. the condition that the controller is not powered off
Err08 5A
at power-on 2. The hardware is completely.
faulty. 3. For the hardware fault, contact the agent or
Monufacture.

1. Instantaneous 1. Eliminate external power supply faults and


power failure check whether the power fails during running.
occurs on the input 2. Check whether the wiring of all
Err09 Under-voltage 5A
power supply. power input cables is secure.
2. The input 3. Contact the agent or Manufacture.
voltage is too low.

13-2
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code

3. The drive
control board fails.

1. The brake circuit 1. Check the brake circuit and power input.
is abnormal. 2. Reduce the load.
2. The load is too 3. Check whether the encoder feedback signal and
heavy. setting are correct, and whether the initial
3. The encoder angle of the encoder for the PMSM
feedback signal is is correct.
abnormal.
Err10 Controller 4. Check the motor parameter setting and perform 4A
overload 4. The motor motor auto- tuning.
parameters are
incorrect. 5. Check the power cables of
5. A fault occurs the motor (refer to the solution of
on the motor Err02).
power cables.

1. FC-02 is set 1. Adjust the parameter (FC-02 can be set to the


improperly. default value).
2. The brake circuit 2. Refer to the solution of Err10.
Err11 Motor is abnormal. 3A
overload
3. The load is too
heavy.

1. The power input 1. Check whether the three phases of power


phases are not supply are balanced and whether the power
Power symmetric. voltage is normal. If not, adjust the power input.
Err12 supply 4A
2. The drive 2. Contact the agent or Manufacture.
phase loss
control
board fails

1. The output 1. Check the wiring.


wiring of the main 2. Check whether the contactor on the output side
Power circuit is loose.
Err13 output is normal. 4A
2. The motor is 3. Eliminate the motor fault.
phase loss
damaged.

1. The ambient 1. Lower the ambient temperature.


temperature is too 2. Clear the air filter.
high. 3. Replace the damaged fan.
Module
2. The fan is 4. Check whether the installation clearance of the
Err14 overheat damaged. 5A
controller satisfies the requirement.
3. The air filter is
blocked.

13-3
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code

1.Inspect whether break resistance, break unit


1.Break output short wiring is correct, to assure no short circuit.
Power output circuit;
Err15 2.Inspect whether main contactor work is normal.
abnormal 2.UVW output work is
abnormal 3.Pls contact agent or manufacture.

1. The excitation 1. Check the circuit of the encoder.


current deviation is
too large. 2. The output MCCB becomes OFF.
2. The torque current 3. The values of the current loop parameters are too
Current
Err16 small. 5A
control deviation is too large.
4. Perform motor auto-tuning again if the zero-point
3. The torque limit is
position is incorrect.
exceeded for a very
long time. 5. Reduce the load if it too heavy.

1. The deviation 1. Check whether the encoder runs properly.


between the Z signal 2. Check whether the encoder wiring is correct and
position and the reliable.
Reference absolute position is
3. Check whether the PG card wiring is correct.
signal of too large.
Err17 the encoder 4. Check whether the grounding of the control cabinet 5A
2. The deviation
incorrect and the motor is normal.
between the absolute
position angle and the
accumulative angle is
too large.

The drive control Contact the agent or Manufacture.


Current
Err18 board 5A
detection fault
fails.

1. Enter the motor parameters correctly.


2. Check the motor wiring and whether phase loss
1. The motor cannot occurs on the
rotate properly. contactor at the output side.
2. The motor auto- 3. Check the encoder wiring and ensure that the
Motor auto-
Err19 tuning times out. encoder PPR is set properly. 5A
tuning fault
3. The encoder for the
4. Check whether the brake keeps released during
PMSM fails. no-load auto- tuning.
5. Check whether the inspection button is released
before the PMSM with-load auto-tuning is finished.

1. The encoder model 1. Check whether F1-00 is set correctly.


does not match the
motor. 2. Check the encoder wiring.
Speed 3. If Err20 is reported in the stop state, check whether
2. The encoder wiring
feedback signal lines C, D of the SIN/COS encoder or signal
Err20 is incorrect. 5A
incorrect lines U, V, W of the UVW encoder are broken.
3. The current keeps
large during 4. Check whether the encoder is stuck mechanically
low-speed running. during running.
5. Check whether the brake keeps released during

13-4
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code
running.

1. Check whether the leveling and door zone sensors


work properly.
Leveling 2. Check the installation verticality
The leveling position
signal
Err22 deviation is too large. and depth of the leveling plates. 1A
abnormal
3. Check the leveling signal input points of the MCB.
4. Check whether the steel rope slips.

The RTC clock 1. Replace the clock battery.


RTC clock information of the
Err24 2. Replace the MCB. 3B
fault MCB is abnormal.

Storage data The storage data of Contact the agent or manufacture.


Err25 4A
abnormal the MCB is abnormal.

The earthquake signal Check whether the earthquake


Earthquake signal is consistent with the parameter setting (NC,
Err26 is active and the NO) of the MCB. 3B
signal duration exceeds 2s.

1. Check whether the state (NO,NC) of the feedback


contact on the contactor is consistent with the
parameter setting of the MCB.
2. Check whether the state of the MCB output
indicator is consistent with the contactor action.
Shorting
The shorting PMSM 3. Check whether corresponding feedback contact
PMSM stator
stator feedback is acts after the contactor acts, and whether the
Err29 feedback 5A
abnormal. corresponding feedback input point of the MCB acts
abnormal
correctly.
4. Check whether the shorting PMSM stator contactor
is consistent with the MCB output feature.
5. Check the coil circuit of the shorting PMSM stator
contactor.

1. The automatic 1. Check whether the up/down limit


running time of the switch acts during re-leveling.
elevator is too long. 2. Check whether the leveling signal cables are
Elevator connected reliably and whether the signal copper
2. The re-leveling
position wires may touch the ground or be short circuited with
Err30 running time of the 4A
abnormal other signal cables.
elevator is too long.
3. The up/down limit 3. Check whether the distance between two floors is
switch acts during the too large, causing too long re-leveling running time.
re-leveling process. 4. Check whether F9-02 is set properly (greater than

13-5
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code

4. The steel rope slips the whole normal-speed running time).


or locked-rotor occurs 5. Check whether signal loss exists in the encoder
on the motor. circuits.

1. The detected 1. Check whether the encoder is used properly.


running speed
2. Check the setting of motor nameplate parameters.
exceeds the upper
3. Perform motor auto-tuning again.
protection limit.
2. The speed exceeds 4. Check whether the inspection signal acts at normal
the limit during self- speed running.
Elevator
sliding. 5. Check the inspection switch and signal cables.
Err33 speed 5A
3. The speed exceeds 6. Check whether the emergency power capacity
abnormal
the limit or re-leveling meets the requirements.
is not performed within
7. Check whether the emergency running speed is set
the required time
properly.
during emergency
running.

Logic of the MCB is Contact the agent or manufacture to replace the MCB.
Err34 Logic Fault 5A
abnormal

1. If Err35 is reported when the RUN contactor is not


closed, check:
• Whether the next slow-down switch is valid
• Whether F4-01 (Current floor) is set to 1
1. The elevator is not • Whether the inspection switch is in inspection state
at the bottom floor and supports inspection running
when shaft
• Whether F0-00 is set to 1
auto-tuning is started.
2. No leveling signal is 2. If Err35 is reported at the first leveling position,
received within 45s check:
continuous running. • Whether the value of F4-03 increases in UP
3. The distance direction and decreases in DOWN direction.
between two floors is If not, exchange the MCBs PGA and PGB.
too small.
• Whether the NO/NC setting of the leveling sensor is
4. The maximum
Shaft auto- set correctly
number of landing
tuning data
Err35 floors is inconsistent • Whether the leveling plates are inserted properly if 4C
abnormal the leveling sensor signal blinks
with the setting value.
5. The floor pulses 3. If Err35 is reported during running, check:
change inversely. • Whether the running times out:
6. The system is not
No leveling signal is received when the running time
in the inspection state
exceeds F9-02.
when shaft
auto-tuning is • Whether the super short floor function is enabled
performed. when the floor distance is less than 50 cm
7. Shaft auto-tuning • Whether the setting of F6-00
is not performed upon (Top floor of the elevator) is smaller than the actual
power-on. condition
4: If Err35 is reported when the elevator arrives at the
top floor, check:
• Whether the obtained top floor of the elevator and
bottom floor of the elevator are consistent with the
setting of F6-00 and F6-01 when the up slow-down

13-6
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code
signal is valid and the elevator reaches the door zone
• Whether the obtained floor distance is less than
50 cm
5. If Err35 is reported at power-on, check whether the
detected flag length is 0.

1. The feedback of 1. Check whether the feedback contact of the


the RUN contactor contactor acts properly.
is effective at startup 2. Check the signal feature (NO, NC) of the feedback
of the elevator, but the contact.
contactor has no 3. Check whether the output cables UVW of the
output. controller are connected properly.
RUN 2. The controller 4. Check whether the control circuit of the RUN
contactor outputs the RUN contactor coil is normal.
Err36 feedback signal but receives no 5A
abnormal RUN feedback during
the startup.
3. When both
feedback signals of
the RUN contactor are
enabled, their states
are inconsistent.

1. The output of the 1. Check whether the brake coil and feedback contact
brake contactor is are correct.
inconsistent with the 2. Check the signal feature (NO, NC) of the feedback
Brake feedback. contact.
contactor 2. When both
3. Check whether the control circuit of the brake
Err37 feedback feedback signals of 5A
contactor coil is normal.
abnormal the brake contactor
are enabled, their
states are
inconsistent.

1. There is no input 1. Check whether the encoder is used correctly.


of the encoder pulses 2. Exchange phases A and B of the encoder.
when the elevator 3. Check the setting of F0-00, and change it to CLVC.
runs automatically. 4. Check whether the system and signal cables are
2. The direction of the grounded reliably.
Encoder input encoder signal 5. Check whether cabling between the encoder and
Err38 signal is incorrect when the the PG card is correct. 5A
abnormal elevator runs
automatically.
3. F0-00 is set to 0
(SFVC) in distance
control.

1. Check whether the thermal protection relay is


The motor overheat normal.
Motor relay input remains
Err39 2. Check whether the motor is used properly and 3A
overheat valid for a certain time.
whether it is damaged.
3. Improve cooling conditions of the motor.

13-7
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code

Elevator The set elevator The elevator is used for a long time and needs
running running time is maintenance.
Err40 4B
timeout reached.

1. Check the safety circuit switches and their states.


2. Check whether the external power supply is normal.
The safety circuit 3. Check whether the safety circuit contactor acts
Safety circuit
Err41 signal is cut off. properly. 5A
breaking off
4. Confirm the signal feature (NO, NC) of the feedback
contact of the safety circuit contactor.

1. Check whether the hall door lock and the car door
lock are in good contact.
The door lock circuit 2. Check whether the door lock contactor acts
Door lock
feedback is invalid properly.
breaking off
Err42 during the elevator 5A
during running 3. Check the signal feature (NO, NC) of the feedback
running.
contact on the door lock contactor.
4. Check whether the external power supply is normal.

1. Check the signal feature (NO,NC) of the up limit


switch.
The up limit switch 2. Check whether the up limit switch is in good
Up limit signal acts when the elevator contact.
Err43 4C
abnorma is running upward. 3. Check whether the limit switch is installed at a
relatively low position and acts even when the
elevator arrives at the terminal floor normally.

1. Check the signal feature (NO, NC) of the down limit


switch.
The down limit switch
Down limit
acts when the elevator 2. Check whether the down limit switch is in good
signal
Err44 is running downward. contact. 4C
abnormal 3. Check whether the limit switch is installed at a
relatively high position and thus acts even when the
elevator arrives at the terminal floor normally.

1. Check whether the up slow-down


1. The slow-down
1 and the down slow-down 1 are in good contact.
signal is abnormal.
Slow-down 2. Check the signal feature (NO, NC) of the up
switch position 2. The obtained slow- slow-down 1 and the down slow-down 1.
Err45 down distance is 4B
abnormal 3. Ensure that the obtained slow- down distance
incorrect during shaft
auto-tuning. satisfies the slow- down requirement at the elevator
speed.

1. The re-leveling 1. Check the original and secondary


running speed wiring of the shorting door lock circuit relay.
exceeds 0.1 m/s. 2. Check whether the shorting door lock circuit
Re-leveling
Err46 2. The elevator is out contactor feedback function is enabled and whether 2B
abnormal
of the door zone when the feedback signal is normal.
re- leveling. 3. Check whether the encoder is used properly.
3. The feedback of the

13-8
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code
shorting door lock
circuit contactor is
abnormal during
running.

1. The feedback of 1. Check the signal feature (NO, NC) of the feedback
the shorting door lock contact on the shorting door lock circuit contactor.
circuit contactor is 2. Check whether the shorting door lock circuit
abnormal when the contactor acts properly.
door pre-open and re- 3. Check whether the elevator running speed at door
leveling function is pre-open or re-leveling is set properly.
enabled.
Shorting door 2. The output of the
lock circuit shorting door lock
Err47 contactor circuit contactor times 2B
abnormal out.
3. The elevator speed
exceeds the limit
during running in the
condition that the
shorting door lock
circuit function is
enabled.

The consecutive times 1. Check whether the door machine system works
that the door does not properly.
open to the limit 2. Check whether the CTB is normal.
Door open
Err48 reaches the setting in 5A
fault 3. Check whether the door open limit signal is
Fb-9.
normal.

The consecutive times 1. Check whether the door machine system works
that the door does properly.
Door close
Err49 not open to the limit 2. Check whether the CTB is normal. 5A
fault
reaches the setting in 3. Check whether the door lock acts properly.
Fb-9

Leveling signals 1. Pls inspect whether the inductor of leveling, door


adhension and loss zone is normal.
Leveling
for continous three 2. Inspect perpendicularity and depth of leveling pl
Err50 signals 5A
times (i.e. report E22 ugboard installed.
continous loss
for continous three 3. Inspect input point of MCB leveling signals.
times.) 4. Inspect whether steel cable is slip.
1. Check the communication cable connection.
Feedback data
2. Check the power supply of the CTB.
CAN of CANbus
3. Check whether the 24 V power supply of the
communicatio communication with
Err51 controller is normal. 1A
n abnormal the CTB remains
4. Check whether strong-power interference on
incorrect.
communication exists.

HCB Feedback data of 1. Check the communication cable connection.


Err52 communicatio Modbus 1A
n abnormal communication with 2. Check whether the 24 V power supply of the

13-9
MPDK136 commissioning manual code:YETS-0017-C

Fault Name Possible causes Solution Level


code
the HCB remains controller is normal.
incorrect. 3. Check whether the HCB addresses are repeated.
4. Check whether strong-power interference on
communication exists.

1. Check whether the door lock circuit is normal.


2. Check whether the feedback contact of the door
In the automatic
lock contactor acts properly.
running state, the
relevant door lock 3. Check whether the system receives the door open
Err53 Door lock fault limit signal when the door lock signal is valid. 5A
signal is abnormal.
4. Check whether when the hall door lock signal and
the car door lock signal are detected separately, the
detected states of the hall door locks and car door lock
are inconsistent.
Over-current When inspection 1. Alleviate load.
during running starts, the 2. Change function code FC-00 Bit1 to 1, and cancel
Err54 5A
inspection current exceeds 110% inspection start current function.
start of rated current.
During automatic Check the door open limit signal at the present floor.
Stop at running of the
another elevator, the door
Err55 1A
landing floor open limit is not
achieved at the
present floor.
Serial 1. Check the wiring between the control board and the
peripheral drive board.
The SPI
interface (SPI) 2. Contact the agent or Manufacture.
Err57 communication is 5A
communicatio
abnormal.
n abnormal

1. The up limit and 1. Check whether the states (NO,NC) of the


down limit switches slow-down switches and limit switches are
Shaft position are valid consistent with the parameter setting of the MCB
switches simultaneously. 2. Check whether malfunction of the slow-down
Err58 4B
abnormal 2. The up slow-down switches and limit switches exists.
and down slow-down
switches are valid
simultaneously.
1. Inspect whether analog weighing channel selection
Car ceiling board or
F5-36 is set correctly.
Err62 Analog break MCB analog input 1A
2. Inspect whether car ceiling board or MCB analog
break
input wire is correct, and whether break or not.
Car unintended
E65 UCMP fault movement is detected Clear the fault by handheld operator
during UCMP testing
During monitoring
Braking force Manually test braking force and revert to normal after it
braking moment,
E66 monitoring is tested to be qualified. If it is still not qualified,
insufficient braking
unqualified please maintain the brake.
force is detected.

13-10
MPDK136 commissioning manual code:YETS-0017-C

Note:
• Fault Err41 is not recorded in the elevator stop state.
• Fault Err42 is reset automatically when the door lock circuit is shorted or 1s after the
fault occurs in the door zone.
• If faults Err51, Err52 and E57 persist, they are recorded once every one hour.

Description of Fault Levels


Category State of Fault Solution
1. Display the fault code.
2. Output the fault relay action 1A. The elevator running is not affected on any condition.
Level 1
command.

1. Display fault code. 2A. The parallel function is disabled.


2. Output the fault relay action
command.
Level 2
3. Continue normal running of the 2B. The door pre-open/re-leveling function is disabled.
elevator.

3A. In low-speed running, the elevator stops at special


1. Display the fault code. deceleration rate, and cannot restart.
2. Output the fault relay action
command.
Level 3
3. Stop output and apply the brake 3B. In low-speed running, the elevator does
immediately after stop. not stop. In normal-speed running, the elevator stops, and
then can start running at low speed after a delay of 3s.

4A. In low-speed running, the elevator stops under special


deceleration rate, and cannot restart.
1. Display the fault code.
2. Output the fault relay action 4B. In low-speed running, the elevator does
command. not stop. In normal-speed running, the elevator stops, and then
Level 4 3. In distance control, the elevator can start running at low speed after a delay of 3s.
decelerates to stop and cannot
run again.
4C. In low-speed running, the elevator does
not stop. In normal-speed running, the elevator stops, and then
can start running at low speed after a delay of 3s.

5A. In low-speed running, the elevator stops immediately and


1. Display the fault code.
cannot restart.
2. Output the fault relay action
command.
Level 5
3. The elevator stops 5B. In low-speed running, the elevator does
immediately. not stop. In normal-speed running, the elevator stops, and then
can start running at low speed after a delay of 3s.

Note:
• A, B, and C are fault sub-category.
• Low-speed running involves inspection, emergency evacuation, shaft auto-tuning,

13-11
MPDK136 commissioning manual code:YETS-0017-C

re-leveling,motor auto-tuning, base floor detection, and running in operation panel control.
• High-speed running involves automatic running, returning to base floor in fire
emergency state, firefighter operation, attendant operation, elevator lock, and elevator
parking.
Fault Reset Condition Description

Fault Code Description Reset condition


Over-current during
Err02 Keyboard manual reset.
acceleration
Over-current during
Err03 Keyboard manual reset.
deceleration
Over-current at constant
Err04 Keyboard manual reset.
speed
Over-voltage during
Err05 Keyboard manual reset.
acceleration
Over-voltage during
Err06 Keyboard manual reset.
deceleration
Over-voltage at
Err07 Keyboard manual reset.
constant speed
Pre-charge relay not
Err08 Keyboard manual reset.
close at power-on
Err09 Under-voltage Keyboard manual reset.
Err10 Controller overload Manual reset after 24 seconds.
Err11 Motor overload Keyboard manual reset.
Power supply phase
Err12 Keyboard manual reset.
loss
Power output phase
Err13 Keyboard manual reset.
loss
Err14 Module overheat Keyboard manual reset.
Err15 Power output abnormal Non-manual reset, re-power.
Err16 Current control Non-manual reset, re-power.
Reference signal of the
Err17 Non-manual reset, re-power.
encoder incorrect
Err18 Current detection fault Keyboard manual reset
Err19 Motor auto-tuning fault Keyboard manual reset
Speed feedback
Err20 Keyboard manual reset
incorrect
Leveling signal End station level 1 strong deceleration or limit signal effective
Err22 abnormal auto-reset.
Err24 RTC clock fault Keyboard manual reset
Err25 Storage data abnormal Keyboard manual reset
Err26 Earthquake signal Earthquake signal withdraw, auto-reset.
Shorting PMSM stator Set FE-33 bit4 as 1, auto-reset; no set, manual-reset.
Err29 feedback abnormal
Elevator position
Err30 Inspection reset
abnormal
Elevator speed
Err33 Non-manual reset, re-power.
abnormal
Err34 Logic Stop to auto-reset.
Shaft auto-tuning data
Err35 Keyboard manual reset
abnormal
Set FE-33 bit4 as 1, stop to auto-reset; no set, manual reset.
RUN contactor When stop to auto-reset, maximum continous reset for 5 times. If
Err36
feedback abnormal exceeds times, manual reset. Auto-reset after running one time,
and counter restores zero.

13-12
MPDK136 commissioning manual code:YETS-0017-C

Set FE-33 bit4 as 1, stop to auto-reset; no keyboard, manual


Brake contactor
Err37 reset. Auto-reset times is set by A1-08. Inspection switch is
feedback abnormal
effective, and auto-reset E37. The counter restores zero.
Encoder signal
Err38 Keyboard manual reset
abnormal
Err39 Motor overheat Motor overheat signal withdraw, and auto-rest.
Elevator running
Err40 Keyboard manual reset
timeout
The safety circuit
Err41 Safty circuit is effective, and auto-reset.
breaking off
Door lock breaking off 1.When stop, door lock is effective, and auto-rest.
Err42
during running 2.Auto-reset at door zone.
1.Manual reset due to leveling adhension E22 and returning to
Err43 Up limit signal abnormal limit.
2. Normal running limit abnormal, stop to auto-reset.
Down limit signal 1.Manual reset due to leveling adhension E22 returned to limit.
Err44
abnormal 2. Normal running with abnormal limit, stop to auto-reset.
Slow-down switch
Err45 Stop state inspection reset.
position abnormal
Err46 Re-leveling abnormal Keyboard manual reset
Shorting door lock
Err47 circuit contactor Keyboard manual reset
abnormal
1.Inspect to reset 2. Door open signal is effective, and
Err48 Door open fault auto-reset.
1.Inspect to reset 2. Door close signal is effective, and
Err49 Door close fault auto-reset.
CAN communication
Err51 Car ceiling board communication is normal, and auto-reset.
abnormal
Err52 HCB communication
HCB communication is normal and auto-reset.
abnormal
1.Inspection reset.
2.Door lock short contact causes door lock signal cut off,
and auto-reset.
Err53 Door lock fault
3. The fault is caused by inconformity of landing door lock and
car door lock. When the signal of lock is conformity, it will
auto-reset.
Err54 Over-current during
Keyboard manual reset
inspection start
Err55 Stop at another landing
Door open signal is effective, and auto-reset.
door
Err57 SPI communication
SPI communication is normal, and auto-reset.
abnormal
Err58 When stop, force deceleration signals are not effective at same
Shaft position
time, and auto-reset.
Err62 Analog break Analog input is normal, and auto-reset.
Err65 UCMP test Manually reset by keyboard
Err66 Braking force abnormal Reset after it is retested to be qualified.

Note: Auto-reset fault can be reset manually.


If E41 fault occurs, all faults except Err02 to Err15 will not be shown any more. Check fault
records before cutting off safety circuit.Confirm whether there are non-reset faults.

13-13
MPDK136 commissioning manual Code:YETS-0017-C

14 Group Control Setting Instruction


14.1 Group Control Board specification and assembling wire
14.1.1 Appearance and dimensional drawing

Group control board

14-1
MPDK136 commissioning manual Code:YETS-0017-C

Group control board dimensional drawing


14.1.2 Installation and usage instruction
Terminal definition is shown as below drawing

Group control board terminal definition

14-2
MPDK136 commissioning manual Code:YETS-0017-C

⑴ Group control board indicator description


Item Name Description
POWER Power indicator Group control board is powered and
the indicator is on (red).
CAN1~CAN8 Group control When communication of the group
communication normal control elevators (NO.1~8)is
indicator normal,the corresponding
indicators( CAN1~CAN8) are
on(green).
TXD‐N IE input signal is powered, the
IE Input signal idicator indicator is on (green).
RXD‐N IE output signal IE output signal is powered, the
indicator indicator is on (green).
LINK‐N IE communication IE communication is normal, the
normal indicator indicator is on (green).

Group control board indicator description

⑵ Plug-in CN2 input terminal description


Item Name Description
24V External DC24V power Supply the group control board with
input DC24V power.
MOD+ Modbus LCD communicaton terminal and
communication future function extension
terminal
MOD‐ Modbus
communication
terminal
COM Ground terminal Ground terminal

⑶ Plug-in CN7~CN10 input terminal description


Item Name Description
24V External DC24V Supply corresponding CAN commu
nication module with DC24V power.

14-3
MPDK136 commissioning manual Code:YETS-0017-C

power input
CAN+ CAN Bus CAN bus communication used
communication between group control board and
terminal every elevator in group control
CAN‐ CAN Bus
communication
terminal
COM Ground terminal Ground terminal

Additionally CN1 is connector of operation panel; CN3 is the connector of RS232, which is
used for communicating with upper computer or IE card; CN6 is the connector of IE.
⑷ Jumper function description
Item Way of Description
connecting
J1 Short connect ISP Program download
foot #2,3
J2、J3 short connect foot 232 communication
#1,2 at the same
time
Short connect IE Remote monitering
foot #2,3 at the
same time
J4 Short connect 485 communication terminal
foot #1,2 matching valid
J5、J6、J7、J8 Short connect CAN bus terminal matching valid
foot#1,2

14.1.3 Group control elevators main control panel function codes setting description
(1) Main control panel F6‐07 (number of group control lifts) should be set as 3,4 or 5.
(5)Main control panel F6‐08 (group control lifts No.) is set group control lifts no.: Lift#1
main control panel is set as 1, and through group control panel CN7(CAN1) connector
to realize CAN communication; Lift#2 main control panel is set as 2, and through group
control panel CN9(CAN2) connector to realize CAN communication; Lift#3 main control

14-4
MPDK136 commissioning manual Code:YETS-0017-C

panel is set as 3, and through group control panel CN8(CAN3) connector to realize
CAN communication; Lift#4 main control panel is set as 4, and through group control
panel CN10(CAN4) connector to realize CAN communication.The group control panel
CAN+、CAN- connect with all in one machine CAN2+、CAN2-.
(6) Main control panel F6‐09 Bit3( duplex control option) should be assured to be set
as 1.
14.2 Detailed function table
Function Name Setting Range Minimum The factory Operation
Code unit setting
F0 组 F0 group basic data
F0‐00 Group control 0:Basic mode 1 0
mode setting 1:Efficiency
priority mode
F0‐01 Reserved Reserved

F0‐02 Reserved Reserved

F0‐03 Group control Bit0 : 1 Group 1 0


function control grouping
selection is valid.
Bit1:1 1 0
Decentralized off
line function is
valid.
Bit2 : 1 Energy 1 0
saving running is
valid.
Bit3 : Grouping 1 0
time for lift#5~8 is
used for lift#1~4.
Bit4 : Simplex 1 0
runing time of

14-5
MPDK136 commissioning manual Code:YETS-0017-C

lift#5~8 is used for


lift#1~4.

Bit5~Bit14 : 1 0
reserved
Bit15:/0 0 version 1 0
SCM

F0‐04 Monitoring 0 : Upper 1 0 232


communication computer
interface monitering
function 1 : Remote
selection monitering
F0‐05 MODBUS 0: LCD 1 0 485
function 1 : Extension
selection function1
F0‐06 Current time 2007~2100 1 2007
year
F0‐07 Current time 1~12 1 1
month
F0‐08 Current time 0~31 1 1
date
F0‐09 Current time 0~23 1 0
hour
F0‐10 Current time 0~59 1 0
minute
F0‐11 Software 00.00~99.99 0.01 1.00
version No.
F1 group Grouping function parameter
F1‐00 First group 0: Full collective 1 0
collective selective control
selective 1:Down collective

14-6
MPDK136 commissioning manual Code:YETS-0017-C

control mode selective control


2:Up collective
selective control

F1‐01 First group 0~65535 1 65535


service floor
seting 1
F1‐02 First group 0~65535 1 65535
service floor
seting 2
F1‐03 Reserved Reserved

F1‐04 Reserved Reserved

F1‐05 Reserved Reserved

F1‐06 Second group 0: Full collective 1 0


collective selective control
selective 1: Down collective
control mode selective control
2:Up collective
selective control
F1‐07 Second group 0~65535 1 65535
service floor
setting 1
F1‐08 Second group 0~65535 1 65535
service floor
setting 2
F1‐09 Reserved Reserved

F1‐10 Reserved Reserved

F1‐11 Reserved Reserved

F1‐12 Lift#1 grouping 0: First group 1 0


1:Second group
F1‐13 Lift#1 grouping 00.00~23.59 0.01 00.00

14-7
MPDK136 commissioning manual Code:YETS-0017-C

starting time 1 00.00~23.59(hour.


minute
F1‐14 Lift#1 grouping 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F1‐15 Lift#1 grouping 00.00~23.59(hour. 0.01 00.00
starting time 2 minute)
F1‐16 Lift#1 grouping 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F1‐17 Lift#2 grouping 0: First group 1 0

1:Second group

F1‐18 Lift#2 grouping 00.00~23.59(hour. 0.01 00.00


starting time 1 minute)
F1‐19 Lift#2 grouping 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F1‐20 Lift#2 grouping 00.00~23.59(hour. 0.01 00.00
starting time 2 minute)
F1‐21 Lift#2 grouping 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F1‐22 Lift#3 grouping 0: First group 1 0

1:Second group
F1‐23 Lift#3 grouping 00.00~23.59(hour. 0.01 00.00
starting time 1 minute)
F1‐24 Lift#3 grouping 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F1‐25 Lift#3 grouping 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F1‐26 Lift#3 grouping 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F1‐27 Lift#4 grouping 0: First group 1 0

F1‐28 Lift#4 grouping 00.00~23.59(hour. 0.01 00.00


starting time 1 minute)

14-8
MPDK136 commissioning manual Code:YETS-0017-C

F1‐29 Lift#4 grouping 00.00~23.59(hour. 0.01 00.00


end time 1 minute)
F1‐30 Lift#4 grouping 00.00~23.59(hour. 0.01 00.00
starting time 2 minute)
F1‐31 Lift#4 grouping 00.00~23.59(hour. 0.01 00.00
End time 2 minute)
F1‐32 Lift#5 grouping 0: First group 1 0
1: Second group
F1‐33 Lift #5 00.00~23.59(hour. 0.01 00.00
grouping minute)
starting time 1
F1‐34 Lift #5 00.00~23.59(hour. 0.01 00.00
grouping end minute)
time 1
F1‐35 Lift #5 00.00~23.59(hour. 0.01 00.00
grouping minute)
starting time 2
F1‐36 Lift #5 00.00~23.59(hour. 0.01 00.00
grouping end minute)
time 2
F1‐37 Lift#6 grouping 0:First group 1 0

1:Second group
F1‐38 Lift#6 grouping 00.00~23.59(hour. 0.01 00.00
starting time1 minute)

F1‐39 Lift #6 00.00~23.59(hour. 0.01 00.00


grouping end minute)
time 1
F1‐40 Lift#6 grouping 00.00~23.59(hour. 0.01 00.00
starting time 2 minute)

F1‐41 Lift #6 00.00~23.59(hour. 0.01 00.00

14-9
MPDK136 commissioning manual Code:YETS-0017-C

grouping end minute)


time 2
F1‐42 Lift#7 grouping 0: First group 1 0
1: Second group
F1‐43 Lift#7 grouping 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F1‐44 Lift#7 grouping 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F1‐45 Lift#7 grouping 00.00~23.59(hour. 0.01 00.00
starting time 2 minute)
F1‐46 Lift#7 grouping 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F1‐47 0: First group 1 0
Lift#8 grouping 1: Second group
F1‐48 Lift #8 00.00~23.59(hour. 0.01 00.00
grouping minute)
starting time1
F1‐49 Lift#8 grouping 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F1‐50 Lift #8 00.00~23.59(hour. 0.01 00.00
grouping minute)
starting time2
F1‐51 Lift#8 grouping 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F2 group Forced simplex lift running fuction parameters
F2‐00 Simplex lift#1 0: Invalid 1 0
running 1: Valid
selection
F2‐01 Simplex lift#1 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐02 Simplex lift#1 00.00~23.59(hour. 0.01 00.00
end time 1 minute)

14-10
MPDK136 commissioning manual Code:YETS-0017-C

F2‐03 Simplex lift#1 00.00~23.59(hour. 0.01 00.00


starting time2 minute)
F2‐04 Simplex lift#1 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F2‐05 Simplex lift#2 0: Invalid 1 0
running 1: Valid
selection
F2‐06 Simplex lift#2 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐07 Simplex lift#2 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F2‐08 Simplex lift#2 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐09 Simplex lift#2 00.00~23.59(hour. 0.01 00.00
end time 2 minute)
F2‐10 Simplex lift#3 0:Invalid 1 0
running 1: Valid
selection
F2‐11 Simplex lift#3 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐12 Simplex lift#3 00.00~23.59(hour. 0.01 00.00
end time 1 minute)
F2‐13 Simplex lift#3 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐14 Simplex lift#3 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F2‐15 Simplex lift#4 0: Invalid 1 0
running 1: Valid
selection
F2‐16 Simplex lift#4 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐17 Simplex lift#4 00.00~23.59(hour. 0.01 00.00

14-11
MPDK136 commissioning manual Code:YETS-0017-C

end time1 minute)


F2‐18 Simplex lift#4 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐19 Simplex lift#4 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F2‐20 Simplex lift#5 0:Invalid 1 0
running 1: Valid
selection
F2‐21 Simplex lift#5 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐22 Simplex lift#5 00.00~23.59(hour. 0.01 00.00
end time1 minute)
F2‐23 Simplex lift#5 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐24 Simplex lift#5 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F2‐25 Simplex lift#6 0: Invalid 1 0
running 1: Valid
selection
F2‐26 Simplex lift#6 00.00~23.59(hour. 0.01 00.00
starting time1 minute)
F2‐27 Simplex lift#6 00.00~23.59(hour. 0.01 00.00
end time1 minute)
F2‐28 Simplex lift#6 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐29 Simplex lift#6 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F2‐30 Simplex lift#7 0: Invalid 1 0
running 1: Valid
selection
F2‐31 Simplex lift#7 00.00~23.59(hour. 0.01 00.00
starting time1 minute)

14-12
MPDK136 commissioning manual Code:YETS-0017-C

F2‐32 Simplex lift#7 00.00~23.59(hour. 0.01 00.00


end time1 minute)
F2‐33 Simplex lift#7 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐34 Simplex lift#7 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F2‐35 Simplex lift#8 0: Invalid 1 0
runing 1: Valid
selection
F2‐36 Simplex lift#8 00.00~23.59(hour. 0.01 00.00
end time1 minute)
F2‐37 Simplex lift#8 00.00~23.59(hour. 0.01 00.00
end time1 minute)
F2‐38 Simplex lift#8 00.00~23.59(hour. 0.01 00.00
starting time2 minute)
F2‐39 Simplex lift#8 00.00~23.59(hour. 0.01 00.00
end time2 minute)
F3 group Lifts in group control floor parameters(read only)
F3‐00 Lift#1 Top floor

F3‐01 Lift#1 Bottom


Floor

F3‐02 Lift#1 service 0~65535 for


floor setting 1 Floor 1 to floor 16
F3‐03 0~65535 for
Lift#1 service Floor 17 to floor
floor setting 2 31
F3‐04 Lift #2 top floor

F3‐05 Lift#2 bottom


floor
F3‐06 Lift#2 service 0~65535 for

14-13
MPDK136 commissioning manual Code:YETS-0017-C

floor setting 1 Floor 1 to floor 16


F3‐07 Lift#2 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐08 Lift #3 top floor

F3‐09 Lift#3 bottom


floor
F3‐10 0~65535 for
Lift#3 service Floor 1 to floor 16
floor setting 1
F3‐11 Lift#3 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐12 Lift#4 top floor

F3‐13 Lift#4 bottom


floor
F3‐14 Lift#4 service 0~65535 for
floor setting 1 Floor 1 to floor 16
F3‐15 Lift#4 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐16 Lift#5 Top
Floor
F3‐17 Lift#5 Bottom
floor
F3‐18 Lift#5 service 0~65535 for
floor setting 1 Floor 1 to floor 16
F3‐19 Lift#5 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐20 Lift#6 Top floor

F3‐21 Lift#6 Bottom

14-14
MPDK136 commissioning manual Code:YETS-0017-C

floor
F3‐22 Lift#6 service 0~65535 for
floor setting 1 Floor 1 to floor 16
F3‐23 Lift#6 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐24 Lift#7 Top floor

F3‐25 Lift#7 Bottom


floor
F3‐26 Lift#7 service 0~65535 for
floor setting 1 Floor 1 to floor 16
F3‐27 Lift#7 service 0~65535 for
floor setting 2 Floor 17 to floor
31
F3‐28 Lift#8 Top floor

F3‐29 Lift#8 Bottom


floor
F3‐30 Lift#8 service 0~65535 for
floor setting 1 Floor 1 to floor 16
F3‐31 Lift#8 service 0~65535 for
floor setting 2 Floor 17 to floor
31
FP group User parameters
FP‐00 Password 0~99999 1 0
0: No password

FP‐01 Parameters 0: No; 1 0


updated 1:Restore the
factory
parameters

14.3 Function code detailed description


F0-00: Group control mode selection
0: Basic mode. Main principle of hall call allocation is minimum waiting time with due regard

14-15
MPDK136 commissioning manual Code:YETS-0017-C

to car load and the other factors.


1: Efficiency priority mode. In addition to calculating the waiting time, but also a
comprehensive analysis of the car load, passenger flow volume, etc. in order to determine
the optimal allocation.
F0‐03: Group control function selection
The function code is set for group control function selection. Allowance of each function is
controlled by a binary bit. “1” shows the function is permitted. “0” shows the function is
forbidden. If a lift need group control grouping function, decentralized off line function, and
energy saving traveling function valid, the binary code is 0,000,000,000,000,111,the
function code should be set as 7. Binary codes setting of corresponding functions as below:
Binary code Bit0 Bit1 Bit2 Bit3~ Bit15
Function Group control Decentralized Energy saving Reserved
grouping off line function traveling
function function

F0‐04:Serial interface function selection


The function code is serial interface choose to communicate with upper computer or IE
interface.
0: Upper computer monitor.It communicates through serial interface. Monitor current
running of group control lifts. By this time J2、J3 should short connect leg#1,2 at same time.
1: Remote monitor. After the group control panel is equipped with IE card, customers can
view the current operating state and parameters of group control lifts via the Internet. By
this time, J2、J3 should short connect leg#2,3 at same time.
F0‐05:MODBUS function selection
The function code is to choose use of MOD‐BUS.
0: LCD. Read current operating state and parameters of the lifts in group control system.
1: Extension function 1. According to customers’demands extend the corresponding
functions.
F0‐06 ~ F0‐10:Current time
These parameters are internal time of MCTC-GCB-A group control panel, the clock can

14-16
MPDK136 commissioning manual Code:YETS-0017-C

time if it is powered off. Group control panel complete a variety of specific functions related
to time according to the time. Therefore, when the user firstly power the lift, the five
parameters should be set well according to the actual time.
F1‐01 :First service floor setting 1 (floor 1 to floor 16)
1-01 set respond to the instruction from which floors from floor1 to floor16, F1‐02 respond
to the instruction from which floors from floor17 to floor 31, F1-01 setting way is as follows:
The lift will control the floor to allow the service or not by a 16-bit binary number. The binary
number from low to high respectively represents floor1 ~ 16, the corresponding bit is set to
1 indicates the lift will respond to the call of this floor; corresponding bit is set to 0 indicates
the lift will not respond to call of this floor.
For example, the floors one lift need serve as following chart:

Binary Serve Binary Binary Floor # Serve Binary


number Floor# or not number numbe or not number
bit setting r bit
setting
Bit0 1 Allowance 1 Bit8 9 Prohibition 0
Bit1 2 Prohibition 0 Bit9 10 Allowance 1
Bit2 3 Allowance 1 Bit10 11 Allowance 1
Bit3 4 Allowance 1 Bit11 12 Prohibition 0
Bit4 5 Allowance 1 Bit12 13 Allowance 1
Bit5 6 Allowance 1 Bit13 14 Allowance 1
Bit6 7 Allowance 1 Bit14 15 Allowance 1
Bit7 8 Prohibition 0 Bit15 16 Allowance 1
Corresponding binary set is attached in the table, the binary number is 1111 0110011
1 1101, converted to decimal number is 63101, F1 ‐ 01 should be set to 63101.F1
‐ 02 setting way is the same as the F1 ‐ 01.
F1 ‐ 07 / F1- 08 is setting parameters for the service floors of the second group, s
etting way is exactly the same as F1 ‐ 01 / F1 02.
F1‐12 :Lift#1 grouping
The function of code is to set lift#1 grouping, and system default is the first group.
0: First group. Allocate lift#1 to first group and runs as parameters F1‐00~F1‐02 sets.

14-17
MPDK136 commissioning manual Code:YETS-0017-C

1: Second Group. Allocate lift#1 to second group and runs as parameters F1‐06~F1‐08
sets.
F1‐17、F1‐22、F1‐27、F1‐32、F1‐37、F1‐42、F1‐47 is respectively grouping set
of lift#2~8. The setting way is exactly same as F1‐12.
When set bit0 of F1‐03 as 1(group control grouping valid), the grouping function of above
lifts is valid.

Function code Name Factory setting Setting range Mini unit


F1-13 Lift#1 grouping 00.00 00.00~23.59 0.01
start time1 (hour.minute)
F1-14 Lift#1 grouping 00.00 00.00~23.59 0.01
end time1 (hour.minute)
F1-15 Lift#1 grouping 00.00 00.00~23.59 0.01
start time2 (hour.minute)
F1-16 Lift#1 grouping 00.00 00.00~23.59 0.01
end time2 (hour.minute)

The user can set one or two time periods to group control group lift#1 according to
requirement and allocate normally during the other time periods.
F1‐13 set Lift#1 first period grouping start time; F1‐14 set Lift#1 fist period grouping end
time (i.e. from F1‐13 setting time to F1‐14 setting time is the first period grouping time of
the whole day of lift#1); F1‐15 set Lift#1 second period grouping start time; F1‐16 set
Lift#1 second period grouping end time (i.e. from F1‐15 setting time to F1‐16 setting
time is the second period grouping time of the whole day of lift#1).
F1‐18~F1‐21、F1‐23~F1‐26、F1‐28~F1‐31、F1‐33~F1‐36、F1‐38~F1‐41、
F1‐43~F1‐46、F1‐48~F1‐51 is respectively the grouping time setting of lift#2~8.The
setting way is exactly same as F1‐13~F1‐16.
Note: F1‐13 setting time should be earlier than one of F1‐14. F1‐14 setting time should
be earlier than one of F1‐16. Only when the group control grouping function is valid (Bit0
of F0‐03 is 1), group F1 parameters setting is valid.
F2‐00:Lift#1 simplex operating selection

14-18
MPDK136 commissioning manual Code:YETS-0017-C

The function code set whether lift#1 runs in simplex control.


0:Lift#1 simplex running is invalid.
1: Lift#1 simplex running is valid.
F2‐00、F2‐05、F2‐10、F2‐15、F2‐20、F2‐25、F2‐30、F2‐3 is respectively simplex
running function selection of lift#2~8, the setting way is exactly same with one of F2‐00.

Function code Name Factory setting Setting Range Mini unit


F2-01 Lift#1 simplex 00.00 00.00~23.59 0.01
stat time1 (hour.minute)
F2-02 Lift#1 simplex 00.00 00.00~23.59 0.01
end time1 (hour.minute)
F2-03 Lift#1 simplex 00.00 00.00~23.59 0.01
stat time2 (hour.minute)
F2-04 Lift#1 simplex 00.00 00.00~23.59 0.01
end time2 (hour.minute)

The user can set one or two periods of time to make lift#1 simplex running according to
requirement and runs in group control in the other periods.
F2‐01 set Lift#1 first period simplex running start time; F2‐02 set Lift#1 fist period
simplex running end time (i.e. from F2‐01 setting time to F2‐02 setting time is the first
period simplex runing time of the whole day of lift#1); F2‐03 set Lift#1 second period
simplex runing start time; F2‐04 set Lift#1 second period simplex runing end time (i.e.
from F2‐03 setting time to F2‐04 setting time is the second period simplex runing time of
the whole day of lift#1).
F2‐06~F2‐09、F2‐11~F2‐14、F2‐16~F2‐19、F2‐21~F2‐24、F2‐26~F2‐29、
F2‐31~F2‐34、F2‐36~F2‐39 is respectively simplex running function setting of lift#2~8.
The setting way is exactly same as one of F2‐01~F2‐04.
Note: F2‐01 setting time should be earlier than one of F2‐02. F2‐03 setting time should
be earlier than one of F2‐04. Only when simplex running is valid (F2‐00 is 1), F2‐
01~F2‐04 setting value is valid. Lift#2~8 simplex running function code seting is same as
above.

14-19
MPDK136 commissioning manual Code:YETS-0017-C

FP‐00:Password
Set to any nonzero number, and password protection function is valid.
0: Cancel the password set by the previous user, and make password protection function
invalid.
Remember your password, if forget or lose by mistake, pls contact whith the manufacture.

14-20
MPDK136 commissioning manual Code:YETS-0017-C

15 Through-opening lift debugging way


15.1 Through-opening door instruction
Through opening door relevant parameters
Default
Function Parameters
Setting Range Value
Code Description

Bit2:JP16 is used as front and back door


0
selection (button)

Bit3:JP16 is used for back door opening 0

Bit4: Manual control through opening door only


0
Program control one door opening
F6-40
selection 1
Bit13: The folded instruction is used as 1 di 0
sability, 0 the back door.
Bit14: Door called instruction folds. 0

Bit15:JP20 is used as front and back door shift


0
(button).

Hall called
F8-16 complementary 0~40 0
instructions start
address

Door quantity
FB-00 1~2 1
selection

Lift function Bit15: Through-opening door control


FE-33 0
selection independently.

15-1
MPDK136 commissioning manual Code:YETS-0017-C

Through-opening way selection description

Through
opening Parameters setting Function description Usage
way

Control through-opening doors at


same time: Whatever arrivals from
Way1 FC-04=0
hall call or car call, front and back
doors act at same time.

Front and back hall call


FC-04= Hall call is independent, and door
address setting
1 call is same. When hall call, arrive
Fb-00=2; (1~N),back door hall
Way2 to open corresponding door, and
F8-16=N when door call, arrive to open front call address setting
(N> and back doors at same time. (N+1~40);door call
current front door connects car
highest FC-04=2 Hall call is independent, and door ceiling board CN7, back
floor); call is manual control. When hall door connects CN8,
call, arrives to open corresponding support 20 floors
Way3
door, and when door call, arrives to maxmum.
open front or back door by shifting
button.

FC-04=3 Hall call is independent, door call is


Way4 independent also. Hall call and door
call opens correspondingly.

Note: Through opening door can not be controled independently(at same time), under state of
firefighting, inspection and return leveling.

15-2
MPDK136 commissioning manual Code:YETS-0017-C

16 Voice announcer instruction


16.1 Wiring instruction
4PIN terminal is as shown in the logo printing outer, respectively 24V、MOD+、MOD-、COM.
24V pin connect 24V direct current power positive, and COM connect 24V direct power
negative.
MOD+、MOD- is respectively positive and negative terminal of 485 communication connector
differential signals.
As above instruction, after wiring correctly, the voice announcer can start to work normally.
16.2 Parameters setting
Three buttons are as shown in the logo printing outer, respectively FUN、+ 、-.
Parameters than can be set are as below:

No. Function Parameters value Default Description


1 Language select Chinese/English/Chinese Chinese
and English
2 Background 1~10 1
music select
3 Background 1~16 12 1: silence
music volume 16: maximum volume
4 Announcer 1~16 12 1: silence
volume 16: maximum volume
5 Door-open/close Open/close close Decide whether to use
announcement door open/close
function announcement
6 Set maintainer’ Eleven –bit mobilephone 00000000000 First bit is set as 0, no
s mobilephone no. (All are zero.) number, no
no. announcement.

Parameters setting process:

16-1
MPDK136 commissioning manual Code:YETS-0017-C

Voice announcer is powered.

Normal operating mode

Press key FUN


No operation
in 10 seconds
Select Language by
Language select “+” “-”

Press key FUN


No operation
Select background
in 10 seconds
Background music select music by “+”
“-”.( Total 10 songs
can be choosen)
Press key FUN
No operation Set background
in 10 seconds music volume by “+”
Background music volume
“-”. “1” is silence.

Press key FUN


No operation Set announcer
in 10 seconds volume by “+” “-”.
Announcer volume

Press key FUN


No operation Set whether to
in 10 seconds Door-open/close announcement announce
function door-open/close by
“+” “-”.
Press key FUN
No operation
“+” is for revising
in 10 seconds Set maintainer’s mobilephone phone no. “-” is for
No. next phone’s revisal.
Press key FUN

Save setting, and enter 16-2


operating mode.
MPDK136 commissioning manual Code:YETS-0017-C

Parameters setting process instruction: (By default the lift is powered, and it will enter running
mode, and can set operation.)
Firstly, press key FUN, the voice announcer will show Function 1, i.e.“Announcer language
selection”;
Then press key “+” or “-” to set parameters value. When operating, the announcer will voice the
chosen parameters value, i.e. “Chinese”, “English”or “Chinese and English”.
Lastly press key “FUN” again.The announcer will save the parameters and shows the next
function, i.e. “background music selection”.
In turn, when press key “FUN”each time, the current parameters will be saved and the next
function is shown. When the last parameter is set and press key “FUN”again,indicating “save
setting and enter running mode”, announcer returns to running mode.
Under running mode only pressing key “FUN” can reset parameters. In the process of par
ameter settings it does not respond to announcement instruction, and in the absence of v
oice playing if no key pressing for more than 10 seconds, parameters are saved automati
cally, and it will return to runing mode, at the same time indicates "save Settings, and ent
er running mode".
When setting up the "background music selection" function parameters, each time you press "+"
or "-" after modifying parameters, in addition to broadcast the corresponding parameter value "1
to 10", and then will play the appropriate background music, before the end of the music playing,
and 10- second timeout timer operation does not start, it can respond to any key operation to
end playing for the new settings.
When setting up function parameters of the "background music volume" and "announcer
volume", after each time press "+" or "-" to modify parameters, in addition to broadcast the
corresponding parameter value "1 to 16", and then also play the appropriate background music
or language as setting volume. Similarly, before the end of the music playing, and 10- second
timeout timer operation does not start, it can respond to any key operation.
After a system failure, firstly announcement broadcasts comforting word, if detected
maintener’s phone number , (the fist bit is not "0". )and broadcast 11-bit phone number, and
broadcast twice, before broadcasting background music (volume alleviates ). In the fault state,
every minute broadcast one-time comforting word and phone number twice.

16.3 Advanced setting


If need the operation of modifying announcer language, greeting words, advertisement and
special configuration for different floors, you need to remove the SD card and modifify relevant
documents in the card. While operating instruction in SD card - "Advanced Settings Operating
Instructions" is available.

16-3
MPDK136 commissioning manual code:YETS-0017-C

17 Display panel setting


17.1 No display destination control panel

17.1.1 Address set dial switch description

Name Dial position Function description


S1 1~6 Floor address setting, range 0~63
S1.1 F0 Destination dispatch binary bit0
S1.2 F1 Destination dispatch binary bit1
S1.3 F2 Destination dispatch binary bit2
S1.4 F3 Destination dispatch binary bit3
S1.5 F4 Destination dispatch binary bit4
S1.6 F5 Destination dispatch binary bit5

Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board. Hall call address can not be set as 0, hall call address can not be repeated, otherwise it will
affect system communication and cause abnormal operation.

17-1
MPDK136 commissioning manual code:YETS-0017-C

17.1.2 Landing light control panel function setting


Name Dial position Function description
S2 1~6 Function selection function
S2.1 IMPE MOD bus terminal matching resistance
setting ( set it as OFF, no need modify)
S2.2 FUN2 OFF
S2.3 FUN1 ON
S2.4 TEST TEST
S2.5 FUN3 OFF
S2.6 FUN4 OFF

Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board. Hall call address can not be set as 0, hall call address can not be repeated, otherwise it will
affect system communication and cause abnormal operation.

17.1.3 Binary operation panel function setting


Name Dial position Function description
S2 1~6 Function selection, ect.
function
S2.1 IMPE MOD bus terminal matching
resistance setting ( set it as OFF,
no need modify)
S2.2 FUN2 ON
S2.3 FUN1 OFF
S2.4 TEST TEST
S2.5 FUN3 OFF
S2.6 FUN4 OFF

Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board. Hall call address can not be set as 0, hall call address can not be repeated, otherwise, it will
affect system communication and cause abnormal operation.

17.2 Hall transverse LED display panel

17-2
MPDK136 commissioning manual code:YETS-0017-C

17.2.1 Address setting instruction:


Press button S1 for first time. Display area indicates current saved floor address. Afterwards when press
button each time, floor address is plus 1. When press button for above 2s, floor address will be increased
rapidly. When floor address is 56, continue to press S1, the floor address will increase again from 0, cycle
is like this.
Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board.The address of internal display is set as 0 and hall call address can not be set as 0. Hall call
address can not be repeated, otherwise it will affect system communication and cause abnormal operation.
17.2.2 Chinese/ English, transverse/vertical display ways selection instruction:
J6 set Chinese/English display, Foot #1,#2 short contact English; Foot #2,#3 short contact Chinese.
Default is Chinese (Square welding plate is Foot #1).
J10 set transverse/vertical display Foot #1,#2 short contact vertical display; Foot #2,#3 short contact
transverse display. Default is transverse display.
(Square welding plate is Foot #1).

17.3 Ultrathin dot matrix display panel, 5” and 7’’ segment code LCD

Ultrathin dot matrix display panel, 5” segment code LCD 7’’ segment code LCD

17-3

Display Zone
MPDK136 commissioning manual code:YETS-0017-C

17.3.1 Address setting instruction:


Floor storage pins, while the jumper is set to ON (set JP2 to ON for 5” and 7’’ segment code LCD), up and
down calling buttons convert to plus or minus button for modifying and storing floors. To remove short
contact and floor is stored. When floors address is increased to 56, continue to press the up button, the
floor address will reincrease from 0, the cycle is like this. When the jumper has no short contact, the
function converts to call function.
Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board. The address of internal display is set as 0 and hall call address can not be set as 0. Hall call
address can not be repeated, otherwise it will affect system communication and cause abnormal operation.
Note: When LCD is stored in Low temperature (below 0 ℃) environment for a long time, it can
not be allowed to power immediately. It must be stored in above 0℃ environmentaltemperature
for more than 24 hours before power is supplied.
17.4 4.3” 6.4” segment code LCD panel, 4.3” TFT LCD

4.3” segment code LCD panel 6.4” segment code LCD panel 4.3” TFT LCD

17.4.1 Address setting instruction:


S1 function: Set floor address. The instruction is as following:
When press button S1 first time, display area indicates the current storage floor address; afterwards when
press the button each time, the floor address will be plus 1. When press the cutton for above 2s, the floor
address will be increased rapidly. When floor address is 56,
Hall call board is set according to absolute floor address. Absolute floor includes safety door, additional
leveling board. The address of internal display is set as 0 and hall call address can not be set as 0. Hall call
17-4
MPDK136 commissioning manual code:YETS-0017-C

address can not be repeated, otherwise it will affect system communication and cause abnormal operation.
Note: When LCD is stored in Low temperature (below 0 ℃) environment for a long time, it can
not be allowed to power immediately. It must be stored in above 0℃ environmentaltemperature
for more than 24 hours before power is supplied.
17.5 7” TFT LCD panel

Function setting
Function setting key:S1----confirmation key; S2----shift, increase key; S3----shift, decrease key
Press the key S1 to enter main interface of function setting
Floor address setting menu: floor address can be set and viewed in the interface.
Floor address setting method: press the keys S2/S3 to shift the cursor to 1 floor address and press
the key S1 to enter modification mode, address high bit is in selected mode, meantime increase and
decrease floor high bit by S2/S3; press the key S1 again to make address low bit be in selected
mode, meantime increase and decrease by S2/S3. After the setting of address low bit press the key
S1 again to exit the mode of floor address setting. Floor address range: floor 0-56.
Hall call board is set according to absolute floor address. Absolute floor includes safety door,
additional leveling board. The address of internal display is set as 0 and hall call address can not be
set as 0. Hall call address can not be repeated, otherwise it will affect system communication and
cause abnormal operation.
System setting menu: in the page you can set transverse or vertical display page.
Setting method: press S2/S3 to move the cursor to 3 System setting, and press S1 to enter
modification mode, and then press S1 again to pick on the character Transverse or Vertical. Choose
Transverse or Vertical by S2/S3. After choosing the character press S1 to confirm. And move the
cursor to 5 Return by S2/S3, at the same time press S1 to exit. The setting is finished.

17-5
MPDK136 commissioning manual code:YETS-0017-C

Note: When LCD is stored in Low temperature (below 0 ℃) environment for a long time, it can
not be allowed to power on immediately. It must be stored in above 0℃ environmental temperat-
ure for 24 hours before power is supplied.
17.6 8.4”TFT truecolor LCD panel

17.6.1 LCD instruction

17.6.2 Interface configuration instruction


17.6.2.1 Interface layout (parallel signal)

17-6
MPDK136 commissioning manual code:YETS-0017-C

17.6.2.2 Interface instruction


Ÿ Floor parallel signal input: A1~G2,binary code
Ÿ Direction signal input: UP , DOWN
Ÿ Elevator running state input: overload OVER, fire alarm FIRE, maintenance MAINTEN,(reserve
two interfaces of elevator state input X0、X1)
Ÿ Power supply input: +24V, GND
Ÿ Time and date adjustment button: MOD,INC
Ÿ Volume adjustment button: VOL+,VOL-
Ÿ SD card slot, U disk (USB) slot, SPK input port

17.6.3 Adjustment of time and volume

17.6.3.1 Adjustment of time


Ÿ Press the button MOD, the screen displays date and time of 20XX (Y ) X (M) X(D) XX:XX:XX,
there is one X blinking.
Ÿ As long as the button MOD is pressed once flicker bit for date and time will move right to the next
bit until the rightmost bit.
Ÿ When the bit is blinking, as long as you press the button INC once,blinking bit will be plus 1, thus
the effect of adjustment will be achieved.
Ÿ After the bits are adjusted, press the button MOD until the last bit blinks. If the button MOD is
pressed again, the date on the screen will change and the time adjustment will be finished.

17.6.3.2 Volume adjustment


When the video is played by the video player, press the buttons VOL+ and VOL- to adjust the
volume and current volume will be shown on the screen. Press VOL+ to increase the volume (the
maximum volume is 15), press the button VOL- to decrease the volume. (the minimum volume is 0)
17.6.4 Replace the picture and video
17.6.4.1 Use management software untitled.exe to process pictures
17.6.4.1.1:Preparatory work

17-7
MPDK136 commissioning manual code:YETS-0017-C

Plug formatted FAT32 U disk or SD card into USB slot (put SD card into card reader and then
put the card reader into USB slot.). When you see movable disk, open the software untitled.exe in
the folder Soft and Usage instruction of Upper Machine in CD supplied by our company. The
interface is shown as picture 1

Picture 1
Click the button 【路径】and set the route to movable disk route of U disk and SD card ( you
may choose any position of computer disk to copy converted folder and file to root directory of U
disk or SD card) it is shown as the picture 2

点 Click the button【确认】in picture 1 to enter the following interface.

Picture 3

17-8
MPDK136 commissioning manual code:YETS-0017-C

Picture 3 is for management interface. We can use small picture and logo. The video is explained
separately.
17.6.4.1.2 Picture replacement
The operations of 小图 and logo are the same. Take 小图 as an example: click【小图】 in
picture 3 to choose managing 小图. Click the button【添加】to add not more than 16 pieces of
small pictures.

Picture 4
Choose a line in picture 3 and click the button【删除】to delete list options; double click a line
or choose a line to click【浏览】to browse the picture, shown as picture 5.

Picture 5
After clicking【生成】 the software will save the file corresponding to small picture list after it
17-9
MPDK136 commissioning manual code:YETS-0017-C

is processed to preset route.


Note: If route is U disk or SD card, computer will be lag during the process of conversion (If
route is optional position of computer hard disk, the situation will not occur. At this time it is
needed to copy converted file folder and file to U disk or SD card root directory.
17.6.4.1.3 Picture processing instruction
Pictures only supports format BMP, JPG. Other format pictures need to be converted by other
tools software such as PhotoShop.
Original image resolution is not required, but processed pictures will be forced into a multimedia
video machine support picture resolution, the picture effect can be browsed and viewed.
Video machine supports a piece of LOGO, 16 pieces of small pictures at most. You can replace
the pictures less than maximum number.
Example 1: Only add five pieces of small pictures without adding LOGO. The video machine
only displays five pieces of small pictures without replacing LOGO after the replacement of the
pictures.
Example 2: Only add a piece of LOGO. Only replace a piece of LOGO without changing small
pictures after the replacement.
17.6.4.1.4 播放列表 Operation:

Picture 6

17-10
MPDK136 commissioning manual code:YETS-0017-C

播放列表: 24 hours a day are divided into 1 ~ 6 section. Choose the content which shall be
played in a certain time. There are three options for play content: video, pictures (no sound),
picture and music. For example, play the video from 0 to 4 o 'clock in the morning.
Specific function instruction:
First click 播放列表

Picture 7
Choose 【无】and click the button【编辑】or double click the line with【无】, the following
dialog box will pop up.

Picture 8
Edit the play content and end time. After editing click the button【设置】. When end time does
not reach 23:59, next line will be automatically generated, at most six lines.

17-11
MPDK136 commissioning manual code:YETS-0017-C

Picture 9
Press the button【加载】to load previous setting.
Press the button【清除】to delete edited or loaded list and return to the state in picture 7.
Press the button【生成】to generate playlist under root directory of movable disk.
17.6.4.2 Video replacement
17.6.4.2.1 Use conversion tool MediaCoder to convert video format.
The volume of user video file is too big and coded format is inconsistent, so conversion tool
MediaCoder is needed to make video file be converted to proper file and updated to LCD.
17.6.4.2.2 MediaCoder software installation
Double click video conversion icon shown in the following picture

Click【OK】

17-12
MPDK136 commissioning manual code:YETS-0017-C

Click 【Next】

Click 【I Agree】

Click【Next】after choosing software installation route

17-13
MPDK136 commissioning manual code:YETS-0017-C

Choose【Full】in installation components and then click【Next】

Wait for the installation

17-14
MPDK136 commissioning manual code:YETS-0017-C

Choose 【Run MediaCoder】and then click【finish】

Click the icon in the upper right of the computer, window MediaCoder will pop up;
17.6.4.2.3 MediaCoder converting video
Click 【File】and click【Add file】in pull-down menu to add the video file to be converted
shown as the following picture.

Choose the video and load preset file presetfile.xml in the file folder of Video File Conversion
Software and Operating Manual in the CD supplied by our company. After loading refresh (We
have finished the setting of the parameters.

17-15
MPDK136 commissioning manual code:YETS-0017-C

Start converting after the setting; choose【transcode】and click【start transcoding】in the


pull-down menu, shown as the following picture.

After the completion of converting conversion software will generate new video file under the
folder in which original file is located. Change the names of converted video files into A.avi and
B.avi and copy them to SD card or under U disk root directory.

17-16
MPDK136 commissioning manual code:YETS-0017-C

Note: Some customers point out that two videos A.a vi and B.a vi cannot be updated into the
video machine by U disk or SD card. The situation occurs because file extension has been hidden
by some computer systems. At this time only need to change the names of converted video files
into A and B.
17.6.4.3 Replace the files in video machine.
17.6.4.3.1 SD card replacement
Cut off the power supply of plug-in card video machine. Plug SD card containing converted
picture and video into SD card slot of video machine. Power on again and wait several minutes.
When the screen shows the prompt of “Pull out the Card, And restart the machine”, the
replacement will end. And then pull out SD card and restart the video machine.
17.6.4.3.2 U disk replacement (U disk of USB2.0)
Plug U disk containing converted picture and video into USD slot of video machine. At this
time video machine will restart automatically again and copy the file in U disk, please wait several
minutes. When the screen shows the prompt of “Now please unplug the U disc!”, the copy process
will end. And then pull out U disk and restart the video machine.
17.6.4.3.3 The sketches of file in U disk or SD card are shown as follows:

17-17
MPDK136 commissioning manual code:YETS-0017-C

18.BLT12 Five-way intercom debugging method

18.1 The control room host

Control room host falls into two categories, with display (type: BLT12-254N) and without display (type:
BLT12-16N).

18.1.1 Control room host without display (BLT12-16N)

Extension calling the host: the elevator number indicating lamp corresponding to the control room host is
bright, five-way intercom is carried out by pressing the corresponding button after off-hook of the phone.
Host calling: five-way intercom is carried out by pressing the extension number after off-hook of the
phone.
If there are multiple elevators calling control room host at the same time, all elevator number lights
corresponding to the control room host will be all bright. Press the corresponding elevator number button
to call back after off-hook of the phone.
Control room host without display shown as picture 1(BLT12-16N),connection terminals shown as
picture 2.

Picture 1:BLT12-16N

17-18
MPDK136 commissioning manual code:YETS-0017-C

18.1.2 Control room host with display (BLT12-254N)


25.1.2.1 Connection terminals are shown as picture 2: the terminals are the back of the control room host
with two groups of terminals per unit with equivalent function.

Picture 2
25.1.2.2 Instruction for control room host

Picture 3:BLT12-254N

(1)When extension calling host, host phone rings and calling indication light flashes and display screen
shows calling subsystem number. After off-hook of the phone subsystem interphone is automatically
connected so that calling can be carried out; Calling is ended when phone is hung up.
(2)When host calling extension, enter three digit number subsystem number after off-hook of the phone,
e.g., when calling No.8 subsystem, directly enter 008 to connect it.

(3)When several extension calling host, the host phone rings and indication light flashes and display
screen shows calling ( 7 groups of calling are shown at the same time and the newest calling is placed on
the first place.) the first group of numbers is automatically connected at once after off-hook of the phone.
When subsystem is needed to switched, push the button of “next” button or directly enter subsystem
17-19
MPDK136 commissioning manual code:YETS-0017-C

number and then hung up to end calling.(Note: at any time only one subsystem is involved in intercom.)

(4)Routing inspection: routing inspection should be carried out in hung-up condition. If phone is
off-hook or branches connecting main calling during the inspection, the inspection will be terminated.
Attentions should be paid when using. Routing inspection includes automatic inspection and manual
inspection. During automatic inspection, routing inspection for subsystem is made at 2:00 a.m. every day.
Manual inspection can be done at any time. If subsystem fault is found, the indication light will be bright,
at the same time fault elevator number will be recorded and query can be done in subsystem fault
information.

25.1.2.3 Control room host (BLT12-254N) menu instruction

(1) Introduction for indication light of control room host

1. The indicating lamp for off-hook phone is lit. The host for control room is in off-hook status which can
monitor whether the handset of the phone has been put in proper place.
2. Phone indicating lamp being lit shows control room host has been switched to calling status. (Standby:
no this function)
3. Flashing of call indicating lamp shows call needed for handling.
4. Fault indicating lamp being lit shows subsystem has fault and cannot return signal during the routing
inspection.
5. Standby/emergency indicating lamp being lit, control room host is in hung up status, monitoring
whether the handle is put in proper place.
6. Standby/emergency indicating lamp being lit shows cutting off with electric supply and starting standby
power supply.

(2) Introduction for control room host function key

1. “confirmation/exit” key is used for the functions such as coordination for calling, entering and exiting
the main menu or submenu.
2. Call/test key is used for switching to the function of calling or testing call transfer. (Standby: no this
function)
3. Submenu/pages turning key, use the key when prompted after entering the submenu
4. Submenu/query key, the key is used to inquire the main menu repeatedly.
5. “△”is up key, “▽”is down key which coordinates submenu.
6. Next key is shortcut key used to switch next subsystem.
7. Browse key is shortcut key used to browse basic information of the machine.
8. Number key “0-9” is used for phone dialing and call dialing.

(3) Main menu introduction for control room host


Function main menu adopts list to show, as soon as the user presses main menu/inquire key, all the menus
can be cycled. Press the main menu/inquire in standby condition before entering the menu and
continuously enter 888888 to enter main menu interface when it is prompted to enter the password.
17-20
MPDK136 commissioning manual code:YETS-0017-C

1. Subsystem fault information: query hand is on Subsystem Fault Information, press confirmation key to
enter and information screen shows the subsystem number with the fault (collect when inspecting), press
“submenu/page turning” key to enter next page, showing 12 pages at most.
2. Subsystem registration information: query hand is on Subsystem Registration Information. Press
confirmation key to enter and information panel shows subsystem code of the whole bus system (the
parameter should be preset.) Press submenu/ page turning key to enter next page showing 12 pages at
most.
3. Telephone registration information (standby: no this function)
4. Exit: query hand is on Exit and press confirmation key to exit the menu and return to standby status.
5. Start routing inspection: query hand is on Start Routing Inspection. Press confirmation key to inspect
the registered subsystem node. If faults are found, they should be recorded and preserved and inquired in
Subsystem Fault Information.
6. Clock resetting: query hand is on Clock Resetting. Press confirmation key to correct wrong indication
from the clock.
7. Setting of clock: query hand is on clock setting, show operation prompt after pressing confirmation key
to enter. Set time parameter when prompted.
8. Setting of telephone (standby: no this function.)
9. Overall situation registration: (set the menu only when routing inspection is needed), query hand is on
Overall Situation Registration. Press the confirmation key to enter and directly enter subsystem number
which should be tree-digit number, e.g. If there are 28 subsystems, enter 028. If the subsystem number is
uninterrupted 1-N, please use the function.
10. Register one by one: (set the menu only when routing inspection is needed)
Query hand is on Registering One By One. Press confirmation key to enter. Enter three digit subsystem
numbers to complete registration of single subsystem number. The function is used for registration of the
subsystem with disconnected numbers.
11. Overall situation deletion: (set the menu only when routing inspection is needed to be cancelled).
Query hand is on Overall Situation Deletion. Press confirmation key to delete total registered subsystem
information.
12. Delete one by one (set the menu only when routing inspection is needed to be cancelled). The query
hand is on the “delete one by one”, press the confirmation key to enter and directly enter three bits
subsystem number to complete the deleting of single subsystem number. The function can make
subsystem stop using temporarily.
13. main machine and submachine setting (standby: no this function)
14. C-D type bus setting: the product of our company is defaulted to type D, modification is not permitted.
15. Termination of emergency output: when query hand is Termination of Emergency Output, press
confirmation key to terminate emergency power output of control room host built-in power supply, at the
same time control room host enters power-off status. When control room host is needed to restart, the plug
is only needed to connect to electric supply in every country.

18.2 Machine room host(BLT12-AC)

17-21
MPDK136 commissioning manual code:YETS-0017-C

Picture 4:BLT12-AC
Machine room extension schematic diagram is shown as picture 4
1. Call three sub machines after off-hook of the machine room extensions.
2. Push the calling button after off-hook of machine room extension and automatically call back (with
display)/manual callback (without display) for five-way call after off-hook of machine room host.
3.Address setting
In the back of machine there are 8 bits dial switch to adopt binary system. The number rule is shown as
follows:

switch bit 1 2 3 4 5 6 7 8
value 1 2 4 8 16 32 64 128

e.g. bits of 1,3,4,7 is 1 and the address is 64+8+4+1=77

Note: address code is binary code; it must be set in a power-off state, otherwise setting is inoperative.
Wiring terminal: there are eight terminals in the bottom of phone as input and output interfaces shown as
the following picture 5 according to product mark icons:

Picture 5

18.3 Car, car top, pit extension(BLT12-B)


17-22
MPDK136 commissioning manual code:YETS-0017-C

A. Appearance shape is shown as picture 6:

Picture 6:BLT12-B

The extension is internal installation type; the sponge on the panel has two functions of buffering in
prevention of rocking and collision and partition between microphone and horn in prevention of voice
interference.

B. Installation attentions

During the installation the hollow-out of microphone and horn must aim at inlet and outlet of installation
panel, otherwise it will affect the quality of calling. It should be as far as possible from strong current
environment such equipments producing electromagnet interference as inverter, contactor and
electromagnet coil, etc. if conditions permit. When arranging of wire, traveling cable should keep away
from strong current line as far as possible. It is suggested to use shielded cable. As shown in picture 7

C. Wiring

Picture 7

AN1 and AN2 are connection output terminals of calling buttons. T1 and T2 correspond to T1 and T2
connecting machine room host. OV and 12V connect external DC 12V power supply. The positive and
negative of the power should be correctly connected, positive connecting 12V, negative connecting OV;
otherwise it will burn circuit board if polarity is reversed.

18.4 Connection for five-way intercom system

17-23
MPDK136 commissioning manual code:YETS-0017-C

The connection of intercom system should be made in accordance with wiring drawing, the requirement of
which is shown as follows:

1. Four core shielded twisted pair cable of RVVPS2*2*0.75mm² should be adopted for the
communication wires between the host in control room and extension in machine room. Both ends of
shielded layers should be reliably earthed, and T1 and T2 is a twisted pair, Y1 and Y2 is also a twisted
pair.

2. As for 254-way control room host, 35 machine room extensions can be equipped within the length of
communication wire of 1500m.

3. As for 16-way control room host, 16 machine room extensions can be equipped within the length of
communication wire of 1500m.

4. In order to ensure the reliable communication, it is suggested not to increase the quantity of machine
room extension in the allowable range of length of bus .

5. It is suggested to adopt “Bus” system for community wiring, as shown in picture 8.

Recommended use
Bus

Unavailable

Tree shape Star shape

Picture 8
◆Note: it is not allowed to adopt tree wiring or star wiring. All elevators have to directly connect to Bus
and the branches cannot be branched to connect other elevators.

17-24
MPDK136 commissioning manual code:YETS-0017-C

All communication signal cables should be as far from interference source as possible (performance in
accordance with national standard GB50348-2004), signal cable shall go through weak electrical well but
not parallel with strong current (e.g. 220V residential power) or radio-frequency signal line (e.g. CATV,
strong signal audio cable). It is recommended to use bus type but not to use tree or star type. If the lines
are parallel, the distance shall be more than 30cm.
The installation position for system equipments should be far away from the environment such as voice,
light, heat, vibration to avoid the effect on the use performance of the system and should be damp proof
and dustproof

Wiring diagram for 16-way control room host(BLT12-16N)

17-25
MPDK136 commissioning manual code:YETS-0017-C

Wiring diagram for 254-way control room host(BLT12-254N)

17-26
MPDK136 Commissioning Manual Code:YETS-0017-C

19 Operation manaul for IC card control system


19.1 Function instruction

1. Swiping card direct arrival function

Swiping card direct arrival card, Set the designated floors of IC card swiping card
direct arrival where the elevator can directly arrive after IC card is swiped.

2. Swiping card press button function

Swiping card press button card, if IC card is swiped and corresponding buttons are
pressed, the elevator will arrive the designated floors.

3. Firefighting function

When there is fire or earthquake disaster in the building, IC card system will be out of
control due to enabling elevator fire function and the state of riding the elevator without
card will be recovered.

4. Visitor linkage function

Using of IC card brings the security but brings inconvenience for the visitors, so the
function of remote automatic calling is added. Its operation method is: after the visitor is
confirmed by the owner, the owner don't need to meet at the elevator door but only need
to press the remote calling button at home, the elevator will automatically open the
corresponding floor button for the visitor and not open other floor buttons. As long as the
visitor presses the corresponding floor buttons of the owner home, he will arrive at the
owner’s home. It is not only convenient for visiting and exchange of visits and a
guarantee for safety but also it has improved the intelligence of the lift.

5. Mandatory management function can set the opening or disabling for user’s cards of
corresponding room to elevator No. by wiping mandatory management card in master
card read area. Specific operation method is: when making mandatory management card,
first choose disabling, and then fill in the disabled user's room number at the room
number.

Mandatory management cards can disable using all of cards of corresponding room
number to elevator No. Manatory management cards can enable using all of cards of
corresponding room number to elevator No. If using cards is enabled again after
disabling, the user can use the card after firstly choosing the enabling when making
mandatory management card, filling in room numbers of the users to be enabled at the
room number and then wiping once more at the card reading area.
6. Card loss report function

If the card is lost, a new card with the same card number shall be made. After it is wiped
twice at main card reading area of corresponding elevator, the new card can be used by
the user. At the same time the lost card has been invalid.

7. Charging function
Exchange between charging by swiping the card and no charging is finished by
setting hardware. Setting unit price for riding in upper computer enables different
consumption prices for different floors reflecting the fairness of elevator using charging.
MPDK136 Commissioning Manual Code:YETS-0017-C

8. Period restriction function


Set card valid time when making period card to make passengers swipe the card and ride
the elevator within its validity. Passenger cannot use the elevator out of validity.

9. Fault automatic detection function


When the car roof plate has been communicating abnormally with IC card controller 485
for more than 3 seconds (check error or communication interruption), the elevator will
be in a state without car call. Door can be opened and closed. Power off and then power
on automatically losing control of IC card and turning into riding without cards

10. Output time adjustment function


According to the demand change the output opening time. Specific steps are the
production of control time response card on PC software and time setting range is 1 ~ 9
seconds which is adjustable.

11. Record and read elevator using function


System can record the user card number, using time, the use of the elevator codes,
the remaining use number (only for charging CARDS), and other information (record up
to 8000), being convenient for managers to query.
Software makes and reads the user's data card being easy to read each elevator using
record (each IC card can read at most 84 records once).

Note: when making a replacement card during the initialization click initialization so that
the window appears after the initialization, if you click“是”, then information of the card
used before in the controller will be "no record", if you click on the“否”, then the
corresponding information of the card used before remains the same and is still recorded
in the controller.

For example: the original card number is 00002, click the "yes" after initialization and
then make a new card with this card whose card number is 00003. When swiping card
00003, corresponding information for riding the elevator to card number 00002 in car
call controller will become "no record"; if click "no", wipe card 00003, corresponding
information for riding the elevator to card number 00002 in car call controller will not
change and continue to store inside car call controller.

12. Support password riding function (optional). Control corresponding floor button by
connecting the password keyboard to realize password riding.

13. Double support functions (optional) can be realized by connecting two heads by head
switchers and used for the elevator with opposite door double operation panels.

14. Time-sharing management function


MPDK136 Commissioning Manual Code:YETS-0017-C

When elevator is used frequently in holidays, voluntarily set system start or


shutdown in multiple time periods (freely use the elevator without needing to wipe the
card after the system is turned off). For example you can turn off the system for the
convenience of visiting friends during the Spring Festival. After this period of time
restart the system.

15. Floor management function


Use floor management card to set the floors being controlled or uncontrolled.
16. Door opening and closing limitation function
In the state of IC card door opening and closing should not be limited to avoid
passengers being trapped.

19.2 System composition


System is composed of hardware and software. Hard ware includes IC card car call
controller, car call card reader head, password card reader head, visitor linkage
communication collector, card writer, encryption lock and IC card. Software includes IC
card management system software.

19.3 Hardware instruction

1. MCTC-JT-02G IC card car call controller


1.1 Function description: adopt 485 bus and MCTC-CT series car top plate for
connection to realize smart card control of car floor selection permission including
pressing button, direct arrival by swiping the card, floor management, single charge, time
period charge, self-timing management, blacklist, record storage and etc.
1.2 Function description of terminals and DIP switch

J22 pins function is shown as follows:

Terminal name Function


24+ Outer DC12V~36V power positive pole input
24- Outer DC12V~36V power negative pole input
IN1+ Manual exit switch positive pole input
IN1- Manual exit switch negative pole input
IN2+ Unused
IN2- Unused
OUT+ Unused
OUT- Unused
485+ 485 port positive (connected with car top plate)
485- 485 port negative (connected with car top plate)
J_OUT1 Unused
J_OUT2 Unused
MPDK136 Commissioning Manual Code:YETS-0017-C

J18 : visit function and password keyboard


communication interface (DB9 male)

Visitors function can be realized by connecting linkage communicator. Connection of


password keyboard means opening the push-buttons of corresponding floors by
password setting, so the visitor can ride the elevator without the card. As shown in
figure as the main controller communication interface:

1:GND 3:TB 4:TA


6:GND 8:+5V 9:+24V
J21:Card reader head interface converter interface, which is used when connecting two
interfaces of card reader

J20:Card reader interface

Data exchange of card and main controller is realized by coaxial cable connecting card
reader head

SW1 function is shown as follows:

1 Termination resistance switch matched with visitor linkage


communication interface in J18.
It is normally set to OFF.
2 Termination resistance switch matched with interface 485
in J22.
It is normally set to OFF.

SW2 function is shown as follows:

No. Fuction
1 when it is set ON, enable fault resetting function
When it is set OFF, shut off fault resetting function.
It is normally set to ON
2 It should be dialed to side of number for factory
debugging.
3 It should be dialed to side of number for factory
debugging.
4 When it is set ON, charge.
When it set OFF, free of charge
MPDK136 Commissioning Manual Code:YETS-0017-C

SW3 function is shown as follows:


No. Function
1~7 Elevator number setting; use code 8421, the
number from 1 to 7 orderly represents 1、2、
4、8、16、32、64.
8 It is dialed to number side for the elevator
with trap door; it is dialed to the side ON for
ordinary elevator.

Elevator No.1 is set as

Elevator No.6 is set as

Elevator No.127 with trap door is set as

Elevator number is combined with PC software card making system and set for the users
who hold the card unable to enter the other units (elevator). People with card can only
use the elevator of corresponding elevator number and cannot use the elevators of
different elevator number. Maximum upper limit of elevator number is 127. If there are
two elevators in one unit which have the same tasks, the two elevators can be set to the
same number of elevator. The owner of this unit can only use the elevator of the unit, and
the card is invalid for other units.
Note: number of the elevator can only be set before IC card controller power-on, which
cannot be modified after power-on.

2. MCTC-JT-01I car call card reader head

2.1 Function description


Car call reader head reads information in IC card and communicates with car call
controller to realize the controlling of elevator using permission according to IC card
permission.

3. MCTC-JT-01H password card reader head


Car call card reading head reads information of IC card and communicate with car call
controller to control using permission of the elevator according to IC card permission.
MPDK136 Commissioning Manual Code:YETS-0017-C

3.1 Function description

It not only can read the card but also can enter password to achieve the same effect as
swiping card without IC card.

3.2 Using method and flow

(1)、User registration password: first, the user presses confirmation key * # 5 in turn,
then swipe user card (enter the state of password setting), at this time if the buzzer rings
four tones, it means the card password has been registered, now can only enter the
changes. If the buzzer rings two tones, users can enter 4-digit password for two
consecutive times, and press confirmation key to end. If user hears a tone of buzzer, it
means user password is registered successfully. If user hears four tones of buzzer, it
means the failure of password registration and the need of password re-registration in
accordance with the procedure.
Note: after entering the password registration state, indicator light will blink quickly, the
light is on for about 100 ms and the light is off for 100 ms.
(2)、 User password modification: First user presses modification button * 2 # in turn
and then swipe the card (enter password revision status), at the time if user hears four
consecutive tones, that means that password has not been registered, should be registered
first and changed again. If user hears two tones, the user should enter the initial 4-digit
password first and press confirmation key to end. If user hears a tone from buzzer, it
means that the initial password is correct. And then enter new 4-digit password for two
consecutive times and press confirmation key to end. When the user hears a tone from
the buzzer, it means the password is revised successfully. If four tones from the buzzer
are heard after entering initial password, it means initial password is not correct and
should be revised according to the steps.
Note: the light flickers after entering the state of changing the password, but the light is
on for 50 ms, the light is off for 1000 ms, namely 1s.

(3)、Use the password to open the floor: when the user directly enters the password
(room serial number + password), the incator light will be on all the time. When a tone
from the buzzer of password keyboard is heard, it will mean the password is correct.
When four tones from the buzzer are heard it will mean the password is not correct and
should be re-entered to use the elevator.
MPDK136 Commissioning Manual Code:YETS-0017-C

(4) Administrators modify the password: first of all, the administrator presses
modification button * 1 # and then enter the initial password. When two tones from the
buzzer are heard, it will mean that the initial password is correct. Continue to enter new
10-digit password twice and press confirmation key to end, when one tone from the
buzzer is heard, it means that password entered twice is correct and password is modified
successfully. If four tones from the buzzer are heard when entering initial password, it
will mean that initial password is not correct, and the password should be modified
according to the step. When two new passwords are not the same, four tones from the
buzzer will be heard, at this time re-enter password according to the step.
Note: set two administrator passwords before leaving factory, and they are both
1111111111. When the installation is completed, you must change administrator
passwords into user defined passwords to avoid unnecessary trouble. When entering the
state of administrator password modification the indicator light will flash slowly, the
light is on for 1000 ms, namely 1s, and the light is off for 1000 ms, namely 1s.

(5) Administrator uses the password to enable and disable IC card function:
administrator directly enters the password. When a tone from the buzzer is heard, it will
mean the password is correct. At this time when a tone from car call main controller is
heard, it will mean that IC card using state has been disabled; it means that the elevator
can be used without IC card. When two tones from car call main controller are heard, it
means that the elevator must be used with IC card or keyboard. When administrator
enters the password and hears four tones, it will mean the password is not correct and
password should be re-entered according to the step.

(6) Delete administrator password function: first make a card of deleting password in the
PC software. The card can only delete an administrator password at a time. As long as
the card is swiped on the antenna board once, when one tone from password keyboard is
heard, it will mean the deletion is successful. When four tones from the buzzer are heard
it will mean the deletion is failed. When the deletion is successful, administrator
password is initial password, namely factory password is 1111111111. After user deletes
the password, please change the password to avoid unnecessary trouble.

(7) Delete user password function: first make user card replacement in PC. Check mark
should be drawn in small box in front of DELETE PASSWORD, and it means that the
card is used for deleting the password in the keyboard of password. And then swipe the
card on antenna board once. When one tone from the buzzer is heard, the deletion will be
successful; when four tones from the buzzer are heard, the deletion will be failed.
3.3 car call serial port DB9

Pin 3 of inserter DB9:RS485-


Pin 4 of inserter DB9: RS485+
4.MCTC-JT-05C visitor linkage communication collector
MPDK136 Commissioning Manual Code:YETS-0017-C

4.1 Function description

Using of IC card brings the security but brings inconvenience for the visitors, so the
function of remote automatic calling is added. Its operation method is: after the visitor is
confirmed by the owner, the owner don't need to meet at the elevator door but only need
to press the remote calling button at home, the elevator will automatically open the
corresponding floor button to the visitor and not open other floor buttons. As long as the
visitor presses the corresponding floor buttons of the owner home, he can arrive at the
owner’s home. It is not only convenient for visiting and exchange of visits and a
guarantee for safety but also it has improved the intelligence of the lift.

4.2 Instruction for port and setting switch


J1: power supply and external on-off input and monitoring signal terminal

+24 -24 +IN -IN OUT IN1 IN2

Pay attention to positive and negative poles of power supply in terms of 24V power input.
IN is switch signal input. The switch signal input is active input, so it must be connected
with the power supply. Pay attention to positive and negative. Delay output at OUT
visitor efficient communication; IN1 and IN2 monitor input of intercom communication
signal, IN1 connects to A pole of MAX485 and IN2 connects to B pole of MAX485.
J2: RS485 COM port male being communicated with main controller
MPDK136 Commissioning Manual Code:YETS-0017-C

1:GND 3:TB 4:TA


SW1:The DIP switch is matched resistance switch and set to ON
SW2: bit 1, 2, 3 is the lowest floor difference and is arranged according to 8421 coding
sequence. If there is no lowest floor difference, they shall be set to ON (digital terminal
is effective). Bit 4 is for the reserved charge and bit 5 is for positive and negative value
of the lowest floor difference. When the lowest floor difference is positive value, the
switch shall be set to 5; when the lowest floor difference is negative value, the switch
shall be set to ON and bit 6 is temporarily reserved. When the lowest floor difference is 2,
the switch shall be set to 5. For example: when there is basement which is controlled by
IC card, 5 shall be set to ON; when the first few floors are not controlled by IC card, 5
shall be set to terminal 5.

5. MCTC-JT-07B card writer


5.1 Function description
It corresponds with IC card management system software and is used for making and
reading IC card.

6. MCTC-JT-R4 encryption lock


6.1 Function description
USB interface, used with card writing system increasing safety
7. MCTC-JT-IC IC card
7.1 Function description
Store user information and elevator can arrive at designated floor after card is swiped.

19.4 Elevator control System software

19.4.1 Elevator control system software operation environment


Recommended configuration for operating elevator IC card management system
software:
1、CPU :above PentiumⅡ
2、RAM :500MB or more
3、Hard disk: Above 1GB
4、Operation system: windows2000 /2003/NT/xp
5、Display: 1024*768

19.4.2 Software installation


There is no different between installation of elevator control system software
and other Windows application procedures. Users just operate setup.exe of elevator
control system and then install under prompts step by step.
Ⅰ Install elevator IC card control system software
1. It is suggested that users turn off other Windows application procedures before
installation of the software. Enter Windows operation system and operate “setup.exe” of
elevator control system to install procedure.
2. Please operate next step after closing all other Windows application procedure.
Click button, then the interface will show dialog install catalog selection
as follows :
MPDK136 Commissioning Manual Code:YETS-0017-C

Users select installation catalog of elevator control system card. If you select

button, then it will show the dialog browse files. If you don not

select button, it will use pretermission route “c:\program


files\technology \
elevator control system\”
3、After finishing setting route, click button and show installation
confirmation dialogue
4、Confirm the installation and click to begin the installation.
5、After installation click close to complete the installation.
MPDK136 Commissioning Manual Code:YETS-0017-C

ⅡUnload elevator IC card management system software


There is no different between unloading of all-purpose card software and other
Windows application procedures. Users just operate on control panel under prompts
step by step.
1. Enter Windows operation system and click start menu and let the cursor to select
control panel.
2. Enter the window control panel. Let the cursor select install/remove procedure.
3. Enter the window install/remove procedure and let the cursor select the software
elevator control system. Double click button to prepare to unload elevator
control system software.
4. The screen will show the dialog application procedure deletion to confirm whether
the user unloads the procedure.
5. Let the cursor click button to unload.

19.4.3 The usage of management system software

1. Composition of software
While using management system software, we should know the use and composition
of the software and the operator can easily operate the software according to manual
introduction.
Sketch of system use: Operate in order if you use it for the first time.
System subscriber foundation (details in IV System
subscriber foundation)
Unit price setting: (details in V Unit price setting)
Maintains of elevator information (details in
VI elevator information)
Communication port setting (details in VII communication
port setting)

Use the above operations while you first operate. Then you need not operate the
above operations while you do some business of making card.
After the above operations, you can do some business of making card. Detail
operation, please see the introduction.
2. Log in
1. After operating of the software, there will be a log-in frame which needs
manager’s name and password. If the system is installed for the first time, the
manager’s name is administrator and password: 888888.
MPDK136 Commissioning Manual Code:YETS-0017-C

2. When the manager’s name and password is confirmed, the main interface of
software will show you. Then the manager can operate normally.

3. Change password

Step one: Open the log-in interface


Step two: click the button and then pop-up an interface of
changing password.

Step three: input default password and new password. The new passwords input twice
should be the same.
Step four: click to complete changing password.

4. System user management

Step one: click Maintenance of software platform as follows:


MPDK136 Commissioning Manual Code:YETS-0017-C

Step two: click to open subscriber management interface.

Step three: select the subscriber who wants to change password and
then set the subscriber’s using authority.

Step four: click the button to finish setting authority.

2. Add new system subscriber. Open the window subscriber management and click
and
input number、user name and allow this subscriber use after charging. Then set the

subscriber’s password and authority and click the button to complete the
operation of adding new subscriber.

5. Unit price setting


Step one: click system maintenance on platform of elevator control system software.
The picture is as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Step two: click to open the unit price setting interface.

Step three: input the unit price of each floor

Step four: click the button to complete unit price setting.


Note : unit price setting can set unit price of different floor, while
making card according to the unit price of the highest selected floor .

6. Elevator information
Step one: click system maintains on platform of elevator control system software. The
picture is as follow:

Step two: click to open elevator information interface.

Step three: input elevator information according to elevator actual situation.

Step four: click the button to complete elevator information.


MPDK136 Commissioning Manual Code:YETS-0017-C

1、Elevator serial No. : (refers to elevators number) it is commonly used in fully enclosed
community. It is prohibited to enter and leave other units. If there are two elevators in
one unit which have the same tasks, the two elevators can have the same numbers.
When making cards, the owner of the unit can only use the elevator of the unit. The
card is invalid in other units.
2、Elevator name: you can write randomly but you should remember the elevator serial
No. so as to select the corresponding elevator No. while making card.
3、Floor No.: you can write according to actual floor. (Include all floor controlled by
elevator IC card controller.) or write more than actual floor No.
4、Elevator type: ordinary elevator, trap door elevator and so on. Write according to
actual situation.
5、First floor: The lowest floor of the elevator; If the elevator reaches the first floor
underground which is the lowest floor, fill in -1 here.
6. Office number: not used at present.
7、Floor display name: normally don't write. Under the situation of card swiping limited
floor setting or card making if there is skip-floor write actual controlled floor
numbers, generally expressed in Arabic numerals, and use commas in the middle of
each number, for example: controlled floor is floor 1, floor 5, floor 7 to 10.
1,5,7,8,9,10 or 1, 5, 7-10 can be written here, and the information for the several
floors can be displayed while making card.
e.g.

Note: the name of elevator 1 is 1, the total control floor number is 20, and the type is
elevator with opposite door. Its first floor number is 1, office number is 1, 2, 3 (that is to
say, no. 1 for three elevators, under the condition of the Internet it is set to 1, 2, 3 office
number), the display name is the name of the floor to be controlled and elevator 1 is to
control the floor 1, floor4 and 7-24. Floor 2 and 3 are not controlled.

7. Communication port setting


Step one: click system maintaintenance on platform of elevator control system software.
The picture is as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Step two: click to open the interface for setting communication


port.

Step three: write and read the COM port connecting with the device according to
elevator actual situation.

Step four: click the button to complete setting communication port.

Note:
1. Communication port of card reader should be different from that of remote.
2. Reader communication port: fingerprint collector, fingerprint data collector and
serial port writer are used at the port.
Remote communication port: IC data collector and remote networking
communication port are used at the port.

8. Set backup location

Step one: click system maintenance on platform of elevator control system software. The
picture is as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Step two: click backup location setting to open the interface for setting backup
location.

Step three: fill in proper data backup location according to user actual situation.

Step four: click the button to complete database backup location.


Note: If backup location is not set when it is used for the first time, the above dialog box
will pop up when system is shut down. Backup location should be added to avoid
unexpected problems.

9. Proprietor card making


Proprietor card making is to make card which the proprietor uses. It includes charging
card and time period card making、charging、 re-issued card.
⑴ Make charging card
To make charging card which the proprietor use

Step one: log in and enter the main interface.

Step two: click left side of the main interface to open new card issue
interface.

Step three: click to connect reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully.

Step four: input related information:


MPDK136 Commissioning Manual Code:YETS-0017-C

Input proprietor’s name and door number according to actual situation. There’s no
specific format. Room number is made by the room proprietor lives. Room number
has four bit, for example, the proprietor lives in No. 1, 2/F; his/her room number is
0201.
Card number is formed automatically. The proprietor can change the card number but
he/she can’t use the number he/she used before. Calling method includes manual
selection and automatic selection. It is called manual selection to press the buttons
after swiping the card.
It is called automatic selection to elevator buttons are automatically selected after
swiping the card. (Automatically choose two floors at most for automatic selection,
and the function is realized with corresponding hardware.)

Click on the right side to select elevator. If there is no elevator information, you
can add it in elevator information interface. Details please see VI elevator information.
The proprietor can set use floors by usable floor. Click on the left side to
select.
E-wallet can be used to store money the proprietor deposit on the card. Money can
be charged from E-wallet while you swipe card. The maximum money of every
system operator can be set. Details please see IV System subscriber foundation.
MPDK136 Commissioning Manual Code:YETS-0017-C

Step five: click the button to complete new card making.

Note: ① You can not make new card if the card is not blank. So you should

click to make blank card and then make a new card.

② Dialog box Refund will pop up when initializing if the card is user card

Refund amount can be changed. Sometimes there will be a decimal. There may be
decimals because amount is calculated according to number of times, by this time the
amount can be modified into an integer.

③ Dialogue box will pop up when the card is


initialized. Be careful to choose.

④ If you can not make sure the card information, you can click to
see the card information which is on the information prompt frame right side of the
interface.
MPDK136 Commissioning Manual Code:YETS-0017-C

(2)Make another card for lost card


If the proprietor lost the charging card, he/she can make up another card through this
interface.

Step one: log in and enter the main interface.

Step two: click left side of the main interface to open making up card for
lost card interface.

Step three: click to connect reader. Then the prompt window


will show
system connect successfully with reader. Password loaded successfully. At
the same time prompt you to select card and click enter button to open the interface
which is used for selecting lost card as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Inquire according to the situation provided by the proprietor and then select the lost
card on the result. Click OK button and back to re-issue card for lost card interface.

Step four: click the button to complete making up another card.


Note:
Note: (1) You can not make new card if the card is not blank. So you should

click to make blank card and then make a new card.

(2)Dialog box Refund will pop up when initializing if the card is user card

Refund amount can be changed. Sometimes there will be a decimal. There may be
decimals because amount is calculated according to number of times, by this time the
amount can be modified into an integer.

(3)Initialize card may delete the information of the card in database so please avoid
losing data.

(4)If you can not make sure the card information, you can click to
see the
card information which is on the information prompt frame right side of the interface.
MPDK136 Commissioning Manual Code:YETS-0017-C

⑶ Card charging
If the proprietor’s E-wallet needs charging, he/she can use this interface.
Step one: log in and enter the main interface.

Step two: click on the left side of the main interface to open card charging
interface.

Step three: click to connect reader. Then the prompt window will show system

connect successfully with reader. Password loaded successfully.

Step four: input the sum you want to charge at the place of charging.

Step five: click the button to complete card charging.

Note:

If you can not make sure the card information, you can click to see the
card information which is on the information prompt frame right side of the interface.

⑷ Make time period card


Make time period card which the proprietor use. The card is valid in corresponding time
period only before expiry date. It can be used monthly and yearly and record the recharge
amount in this time period.
Step one: log on and enter the main interface.

Step two: click on the left side of the main interface to open making time
period card interface.

Step three: click to connect reader. Then the prompt window will

show system connect successfully with reader. Password loaded successfully.


Step four: input related information. The picture is as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Note: Input proprietor’s name and door number according to actual situation. There’s no specific
format.
Room number is made by the room proprietor lives. Room number has four digits for example, the
proprietor lives in No. 1, 2/F, his/her room number is 0201. The first two digits shall be not more than
56, and the last two digits shall be not more than 08. If room number is more than 08, compulsory
management card cannot shield the room number. Making of compulsory management card is shown
as item 5 Making of Compulsory Management Card. Card number is formed automatically. The
proprietor can change the card number but he/she can’t use the number he/she used before.
Calling method includes manual selection and automatic selection. It is called manual selection to
press the buttons after swiping the card. It is called automatic selection to elevator buttons are
automatically selected after swiping the card. (Automatically choose two floors at most for automatic
selection, and the function is realized with corresponding hardware.)

Click on the right side to select elevator. If there is no elevator information, you
can add it in elevator information interface. Please seeVI elevator information for details.

The proprietor can set use floors by usable floor. Click on the right side to select.
The validity of the card can be used to set the use time of the card.
Usable time period can be used in twenty-four hours. If the time before and after is the same, it shows
that the card can be used the whole day.
Usable date can be used to set functions according to week and date. If you select, it shows that that
day you can use the card, otherwise the card can not be used on that day.
MPDK136 Commissioning Manual Code:YETS-0017-C

Step five: click the button to complete making time period card.

⑸ Re-issue time period card


Use this interface, if the subscriber’s card is lost.
Step one: log on and enter the main interface

Step two: click on the left side of the main interface to open interface for
making time
period card interface.

Step three: click to connect reader. Then the prompt window will show system connect
successfully with reader. Password loaded successfully. At the same time prompt you to select card
and click enter button to open the interface which is used for selecting lost card as follow:

Inquire according to the situation provided by the proprietor and then select the lost card on
the result. Click enter button and back to re-issue card for lost card interface.

Step four: input new validity at the place of card validity. Input valid time at the place of
usable time period. Input valid week at the place of usable date.

Step five: click to complete re-making card.


MPDK136 Commissioning Manual Code:YETS-0017-C

⑹ Extending usage time

Use this interface to prolong the use time of the proprietor time period card.
Step one: log on and enter the main interface.

Step two: click on the left side of the main interface


to open prolonging usage time interface.

Step three: click to connect reader. Then the prompt window will show system connect
successfully with reader. Password loaded successfully.

Step four: input period of validity at the place of period of validity.

Step five: click to complete extending usage time of card.

Note: If you can not make sure the card information, you can click to see the
card information which is on the information prompt frame right side of the interface.

10. Management Card Making

Management card making is to make card which manager uses. It includes making
management card、mandatory management card , time card for setting button , collector time
card and card for reading proprietor data.

⑴ Management card
The interface is used to make card for managers. The manager can use this card to get the
specific floor.
This card is all pass card, the card is not divided into elevator number setting, time limit, and
monetary limitation. As long as the system is in normal state, the card can be used. The card is
generally distributed to property management personnel, special personnel. Floor authority can
be chosen according to needs when card is made.
Card making steps:

Step one: log on and enter the main interface.


Step two: click management card making on the left side of the main interface.

Step three: click on the left side of the main interface to open the interface for

making management card.

Step four: click to connect reader. Then the prompt window will show system connect
successfully with reader. Password loaded successfully.
Step five: set method for calling elevator and usable floor.
MPDK136 Commissioning Manual Code:YETS-0017-C

Method for calling elevator can be used to assign operation mode of elevator. Manual
selecting floor after swiping card means that you should press the button to select the
desired floor after swiping card. Automatically selecting floor after swiping card means
that the button will automatically lit up after swiping card. Usually multi authorized
floors need manually selecting. Usable floor is used to set the floor which the manager can

use. Click on the right to select. Card holder name is written according to actual
condition and has no requirement of format.

Step six: click the button to complete new card making.

⑵ Make re-issued management card

If the manager lost the management card, he/she can use this interface to re-issue card.
Step one: log on and enter the main interface.

Step one: log on and enter the main interface.

Step two: click on the left side of the main interface to open the interface
for re-issuing management card.

Step three: click to connect reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully. At the same time prompt you
to select card and click 确定 button to open the interface which is used for selecting lost card
as follow:
MPDK136 Commissioning Manual Code:YETS-0017-C

Inquire according to the situation provided by the proprietor and then select the
lost card on the result. Click enter button and back to the interface for
re-issuing card.

Step four: click to finish re-issuing card.

Note: (1) You can not make new card if the card is not blank. So you should

Click to make blank card and the make new card.


(2)Initialize card may delete the information of the card in database so make sure to
avoid lost of data.

Refund amount can be changed. Sometimes there may be decimals because it is


calculated according to number of times, by this time the amount can be modified
into an integer.
(3)Initialization card can remove corresponding information in database to the
card, so it is noted to avoid data loss.

(4) If you can not make sure the card information, you can click

to see the card information which is on the information prompt frame


right side of the interface.

⑶Make mandatory management card


When the function of using the elevator for some room numbers of some floors
need to be disabled, mark room number corresponding to elevator number when
making compulsory management card. After the completion of making the card and
the card is swiped on the elevator, the card will be disabled on the elevator for the
room numbers. If the card need be reused, it will be necessary to enable reopening
of compulsory management card
MPDK136 Commissioning Manual Code:YETS-0017-C

Step of making mandatory management card


Step one: log on and enter the main interface.
Step two: click management card making on the left side of the main interface.

Step three: click on the left side of main interface to


open the interface for making management card.

Step four: click to connect reader. Then the prompt window will show
system connect successfully with reader. Password loaded successfully.

Step five: select enablement or disablement; enablement means the room number is
uncontrollable, as long as the credit card is swiped the room can be used;
disablement means the corresponding room number is unable to be used, as long as
the card is swiped, three tones can be heard, but the floors responded by card are
opened.
Step six: fill in the units needing to be disabled or enabled (room number)

Step seven: click to complete making mandatory management card.

⑷ Make card for setting button time

To make the corresponding time card of setting button for managers who can
use the card to set corresponding time for elevator button (extend the valid time for
selecting floor after swiping card.)

Step for making the card:


Step one: Log on and enter main interface;
Step two: click management card making on the left side of the main interface.

Step three: click on the left side of the main interface to


open the interface for card of setting button time.
MPDK136 Commissioning Manual Code:YETS-0017-C

Step four: click to connect reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully.
Step five: time of assigned button.

Step six: click to complete making time card for assigned button
⑸ Make card for setting controller’s time
To make card of setting controller’s time for manager who can use the card to set the current
time of the elevator controller.

Step one: log on and enter the main interface.


Step two: click management card making on the left side of the main interface.

Step three: click on the left side of the main interface to open the interface
making controller time card.

Step four: click to connect reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully.
Step five: assign the response time of elevator controller.

Step six: click to complete making controller time card.

⑹ make card for reading proprietor data

To make card of reading proprietor data for manager who can use the card to read the
subscribers’ swiping card record

Step one: log on and enter the main interface


Step two: click management card making on the left side of the main interface.

19-1
MPDK136 Commissioning Manual Code:YETS-0017-C

Step three: click on the left side of the main interface to open the interface
for making card for reading subscribers’ data.

Step four: click to connect reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully
Step five: fill in the positions of initial and end records of data information to be read ( the card
can read 84 records at most.)

Step six: click to complete making card for reading subscribers data
⑺ make corresponding time card for visitor button

To make the corresponding time card of visitor button for managers who can
use the card to set corresponding time for elevator button (extend the valid time for selecting
floor after swiping card.)

Step one: log on and enter the main interface.


Step two: click management card making on the left side of the main interface.

Step three: click on the left side of the main interface to

open the interface for making time card of setting button.

Step four: click to connect reader. Then the prompt window will show
system connect successfully with reader. Password loaded successfully.

Step five: assign the corresponding time for visitor button.

19-2
MPDK136 Commissioning Manual Code:YETS-0017-C

Step: click to complete making corresponding time card for setting button.

⑻ Make time period card for setting elevator operation

The card is used to control opening and closing of some floors. It can be used to control the
elevator on different days, different time periods or different floors. (if time period that can be
used is written 00:00 to 00:00 and it illustrates this setting is invalid; if other time periods are
filled out, in this time period, (if not click disable time) of the selected floor need not swipe the
card and press the button directly. If you click on the disable time, in this time period the
button for selected floors can not be lighted up.)

Step one: log on and enter the main interface.

Step two: click management card making on the left side of the main interface.

Step three: click on the left side of the main interface to open the
interface for making time period card of setting elevator operation.

Step four: click to connect reader. Then the prompt window will show
system connect successfully with reader. Password loaded successfully.

Step five: select the elevator which needs setting.


Set number of time period 1-8: each elevator can be set maximum 8 time periods.
You can set 2 time periods while making card. If it is more than 2 time periods, you
should make it on different card.
Authority floor selection: Tick the floor which needs controlling.
Usable time period: the beginning time and the ending time.
Usable date: tick the date and it is valid, otherwise it can not be controlled on time
period.
Forbidding time period: there is no tick which means the floor is open on that period,
you need not swipe card, while you must swipe card on other floor; if you tick the

19-3
MPDK136 Commissioning Manual Code:YETS-0017-C

floor which means the floor can not be used including management card and user’s
card, other floors can be used by swiping card.

Step six: click to complete making time period card for setting elevator operation.

⑼ Make password deletion card


The card is used to delete two passwords of administrator in password keyboard. If there is no
password keyboard in the equipment, the card will be unuseful.

Step one: log on and enter main interface.


Step two: click management card making on the left side of main interface.

Step three: click on the left side of main interface to make password card deletion.

Step four: click to connect the reader. Then the prompt window will show system
connect successfully with reader. Password loaded successfully.

Step five: choose the passwords of the administrator to be deleted; the first and second
password must be separately deleted. It is not permitted to delete the passwords together.

Step six: click to complete making the card for deleting the passwords.

⑽ Make date management setting card


The card has the function of controlling the elevator to be used on a certain floor. It can control the
elevator to be used or be prohibited from using on some floors at a certain time. (At the time period if
prohibited time period is not clicked, directly press the button to choose the floor without swiping the card.
If prohibited time period is clicked, the selected floors cannot light up even if the card is swiped.

Step one: log on and enter main interface.


Step two: Click management card making on the left side of main interface.

Step three: click on the left side of main interface to make date management setting card.

19-4
MPDK136 Commissioning Manual Code:YETS-0017-C

Step four: click to connect the reader. Then the prompt window will show system connect
successfully with reader. Password loaded successfully.

Step five: choose the elevator to be set


Set the time period number from one to eight, open 8 time periods and prohibit 8 time periods. Every
elevator is controlled in 16 time periods at most. Two time periods numbers can be set when making card
each time. When there are more than two time periods, make in different cards.
Usable floor: Tick out the floors to be controlled
Period: Start time and end time of the period
Time period: Start time and end time of some day
Prohibited time period: Selected floors are open in the time period when not ticking without swiping the
card. And other floors can be used only after swiping the card. Selected floors are prohibited using in the
time period when ticking. Administrator card and user card are prohibited and other floors can be used by
normally swiping the card.
Cancel using period: when ticking it means any setting is canceled in the period; when not ticking it
means the period number is set.

Step six: click to complete making date management setting card.

⑾ Make floor management card


The card is functional card to open and close some floors of some elevators. Swipe the card once to do the
floor management; swipe the card for the second time to cancel the floor management of corresponding
floor, and so on.

Step one: Log on and enter the main interface.


Step two: Click management card making on the left side of main interface.

Step three: Click on the left side of main interface to make floor management card.

Step four: click to connect the reader. Then the prompt window will show system connect
successfully with reader. Password loaded successfully.

Step five: choose the elevator to be set and floors to be opened.


19-5
MPDK136 Commissioning Manual Code:YETS-0017-C

Step six: click to complete making floor management card.

11. Statistics inquiry


⑴ Charge statistics

Count the charge.


Step one: log on and enter the main interface.
Step two: Click statistic inquiry on the left side of the main interface.

Step three: click on the left side of main interface to open the charge statistics
interface.
The picture is as follow:

19-6
MPDK136 Commissioning Manual Code:YETS-0017-C

Step Four: conditions of inputting statistics. First select the subscriber, who needs charge, you can
select many people. And then assign the time period (above is the beginning time and below is the
ending time.)

Step five: Click to count.

Note: (1)click to transfer your record of swiping card to EXCEL.

⑵ Inquire the information of the proprietor’s card.

Step one: log on and enter the main interface.

Step two: Click statistic inquiry on the left side of the main interface

Step three: click on the left side of main interface to open the
record inquiry of swiping card interface. The picture is as follow:

Step four: conditions of inputting statistics. Input the information by which you inquire.
For example, if you want to inquire according to card number, you can just input card number. If

19-7
MPDK136 Commissioning Manual Code:YETS-0017-C

you want to inquire according to card number and user name, you can input the card number and user
name

Step five: Click to count.

Note: ① click to transfer your record of swiping card to EXCEL.

⑶ Inquiry for swiping card data


Inquiry for swiping card record collected from Read User Data Card.
Step one: log on and enter main interface
Step two: click management card making on the left side of main interface.

Step three: click on the left side of the main interface to open the interface for
making card for reading subscribers’ data.

19-8
MPDK136 Commissioning Manual Code:YETS-0017-C

Step four: click to connect reading user data card. (Refer to 10.6 to make
user reading data card)

Step five: click to read swiping card data (the card can record 84 records at most.)

19.5 Note:
1.In the situation of the elevator with opposite door two reader heads of car call controller in main and
sub operation board are the same. Distinguish whether it is main door or sub door when making the card.
(When setting elevation information in upper machine the type of the elevator is the elevator with opposite
door; IC card is available for 28 floors open-through, 56 floor single door, and door A is main door and
door B is sub door)
2. One card number only has one corresponding card, or you must make another card.
3. If you want to unload this system, you should make a backup of db document file. For example, you
install the system in C:\Program Files, and then the catalog of db document file is C:\Program
Files\jinbo technology\elevator control system.

19-9
MPDK136 Commissioning Manual Code: YETS-0017-C

20 Instructions for Internet of Things


IOT module can upload the elevator current state of the elevator controller MPDK136 to the
Internet server platform through wireless signal. Users can remotely view the elevator romote
running status by arbitrarily connecting to the Internet Internet software platform and can
remotely monitor the elevator of MPDK136 control system.
20.1 Hardware equipment
A wireless relay module(GPCS1275D001)and a serial port line (GPCS1275D004或
GPCS1275D005)

Wireless relay module port

Connection port is signal emission connection port


Note: PWR and GND are power input terminals of wireless relay module(PWR for 24V
input、GND for 0V input). GND1 and TXD/RXD are communication junction ports for wireless
relay module and elevator controller.
20.2 Connection type

20.3 IOT monitoring content


20.3.1 Elevator real time operation status information includes elevator running, elevator stop,
inspection, fault stop and door open and close state, etc.

20-1
MPDK136 Commissioning Manual Code: YETS-0017-C

Normal stop door close status

Normal stop door open status

When error happens during the running of the elevator fault information is sent to IOT
platform through wired and wireless network.
20.3.2 Elevator real-time fault information: remote monitoring platform displays corresponding
fault code through judging after receiving fault information.

20-2
MPDK136 Commissioning Manual Code: YETS-0017-C

Elevator fault information


20.4 IOT operation introduction
20.4.1 Equipment use requirement for IOT operation platform
Operation system: WINDOWS XP / WINDOWS 2000 / WINDOWS VISTA /WINDOWS
7
Browser: Internet Explorer 6.0/7.0/8.0
20.4.2 Instruction
20.4.2.1 Enter and exit module
Open the IE browser, type http://blt.iotdataserver.cn in the address bar to enter BLT
elevator IOT system user login interface;

User login interface

20-3
MPDK136 Commissioning Manual Code: YETS-0017-C

20.4.2.2 Installation of audio and video plug-in


If it is the first time to login this system, please install the audio and video plug-in ", if not,

the phenomenon of flash back can appear. Click "音视频播放插件" link on the user
login interface:

In the page of the pop-up dialog box of "文件下载", click "运行" button to enter the
download page:

In the page of " Internet Explorer-安全警告", click "运行" button:

20-4
MPDK136 Commissioning Manual Code: YETS-0017-C

Enter plug-in installation interface and click "下一步" to confirm the plug-in installation:

User clicks " 下 一 步 " to confirm the installation before program enters plug-in
installation status:

20-5
MPDK136 Commissioning Manual Code: YETS-0017-C

After the success of the installation of plug-in, program prompts " VideoOcx has been

successfully installed.", users can click "关闭" button to close the plug-in installation
interface.
20.4.2.3 Administrator user login
First login web site http://blt.iotdataserver.cn, and then enter the user name, password and

verification code and click "登录".After login enter the following page:
Step one: click "权限管理" - "角色信息管理" – newly increase roles.

20-6
MPDK136 Commissioning Manual Code: YETS-0017-C

Click “新增”, fill in information and save after filling. The addition of role is built.

20-7
MPDK136 Commissioning Manual Code: YETS-0017-C

Click “确定”, you can see a role just built. After selecting the role, click the button "分配
权限" to enter authority distribution page, and click "保存" after distribution to complete
maintenance authority distribution. Distribution system does not support for the
distributing multiple roles at the same time

20-8
MPDK136 Commissioning Manual Code: YETS-0017-C

Unique permissions and elevators users can view

20-9
MPDK136 Commissioning Manual Code: YETS-0017-C

Administrator user is general user


Responsible for creating the internal supervision unit users of
the administrator, manufacturers users, maintenance unit user
and use unit user
Have the permission of setting short messages and mail format;
Administrator
(the function is not used at present.)
user
Remote update program function can be set for the
equipment.(the function is not used at present.)
Administrator user has function of user, permission and
elevator distribution without business function.
Be responsible for addition, modification and deletion of fault
level.
Be responsible for typing and modification of elevator information
Supervision Be responsible for typing in monitoring area; (the function is not
unit user used at present.)
Be responsible for typing and modification of basic information.
User can view all of elevator lists under administrator.
Common user can only view the lists of the elevators distributed.
Be responsible for typing, modification and deletion of
maintenance personnel information and for distributing
maintenance personnel for elevators. ( the function is not used at
present)
Maintenance
Be responsible for filling process information for treating elevator
unit user
fault and maintenance record.( the function is not used at present)
Default user can view all elevator lists in administor mode.
Common user can only view the lists of the elevators distributed.
Be responsible for filling user feedback information for elevator
Using unit fault and maintenance record.( the function is not used at present)
user Default user can only view all the elevator lists in the unit
Common user can only view the lists of the elevators distributed.

20-10
MPDK136 Commissioning Manual Code: YETS-0017-C

After creating the role you can set up the user. The operation is shown as follows:

Add "监管单位", use account of "监管单位", increase the information of "所属单位". Click "

新增" to increase the users, jump out of the following interface; Enter a user account, user type, the user
password item by item, confirm that the user password, user name, contact phone number, character

information (the role of the above is shown here), unit (only 监管单位 is optional, the other is requisite),

click “ 保存”after filling out.

After saving the following dialogue box pop up, “新增用户信息操作成功”, click “确定”to
finish creating a new supervision user.click “注销用户”to quit system administrator user and
log in “监管单位”newly-built just now.

20-11
MPDK136 Commissioning Manual Code: YETS-0017-C

If authority distribution is not done, the following situation will be prompted.

20-12
MPDK136 Commissioning Manual Code: YETS-0017-C

Click “基础信息”to newly increase the information of “使用单位”、“维保单位”、“产权单


位”、“安装单位”、“制造厂商”. After the completion of increasing click “注销用户”and use
system administrator to log in so as to newly increase the information of “使用单位”and“维保
单位”.
Note: Increase the information of “使用单位”、“维保单位”、“产权单位”、“安装单位”、“制
造厂商”in basic information module in order to increase in information management module.

20-13
MPDK136 Commissioning Manual Code: YETS-0017-C

2.4.3 Wireless relay module information addition

Click “设备信息管理”in the page “信息管理” and click “新增”to increase IOT module
information.

20-14
MPDK136 Commissioning Manual Code: YETS-0017-C

20-15
MPDK136 Commissioning Manual Code:YETS-0017-C

21- Door operator commissioning


21.1 Electrical instruction
The default parameters in this commissioning manual are only suitable for HAD
YTYP504-502 door operator system.
The system is synchronous door operator control system. The synchronous door operator has
no position detection switch (Open limit, open speed change, close speed change, close limit), so
the door motor encoder is used to gather position and speed signals.
21.2 Operation and display interface
User can modify function parameters, monitor work condition, and control (start and stop)
operation when operation panel is running by operation panel.

Drawing 4-1 operation panel interface

21.2.1 Indicator instruction


Implication of LED light on when
Indicator stop Implication of LED light on when running
speed control Distance control
DI1 signal is
D1 DI1 signal is valid external door close command
valid
DI2 signal is AB phase signal is
D2 in process of door close
valid correct
DI3 signal is
D3 Z phase signal in process of door open
valid
DI4 signal is
D4 DI4 signal is valid external door open command
valid

21-1
MPDK136 Commissioning Manual Code:YETS-0017-C

21.2.2 Keyboard button instruction of operation panel

Key Name Function


Programmi
Level 1 menu, enter and exit.
ng key
Confirmati
Level by level enter menu interface; set parameters confirmation.
on key
Press the key to stop running, when running;when fault alarms, press the
stop/reset
key to reset.
When stop and running, press this key to choose LED display parameter
Shift key
in recycle; choose parameter modified bit, when modifying parameters.
Increase
Increase of data or function code
key
Decrease
Decrease of data or function code
key
Door open
Under operation way of panel, it is for door open operation.
key

closing key Under operation way of panel, it is for door close operation.

21.3 Motor parameter auto tuning


21.3.1 Procedure
Choose F002=0:panel operation mode
Choose F100=1:synchronous door motor
Input motor and encoder parameter: F101~F105,F214 (see 2.6 parameter list)
Manual operation makes the door close fully.
Choose F116=4: synchronous motor with load tuning mode(More accurate magnetic angle
value of encoder can be made by tuning with empty load than tuning with load, so tuning
with empty load shall be option if possible)
Press “ENTER” key, after indicating “TUNE” key, and then press “OPEN” key to start
tuning. The door operator finishes tuning, after three sets of open and close actions (after
opening or closing door each time, it keeps running a distance of 5-10cm)
After tuning, check the result by F114.
After auto tuning, press “OPEN” and “CLOSE” to observe if it runs normally.
21-2
MPDK136 Commissioning Manual Code:YETS-0017-C

21.3.2 Instruction
a. Before tuning please confirm whether the signals of encoder are normal. While tuning if
door operates and stalls in the direction of closing door, please exchange wiring of motor or
encoder.
b. When tuning, if Err20 occurs, please exchange any two phases of UVW or retune.
c, When tuning, if the motor does not run or running direction is opposite to opening and
closing command, please exchange any two UVW phases, and retune. If the problem can
not be solved by retuning, change F215 values and tune learning again.
d. If Err19 occurs during identification of encoder position, please check if wiring is correct.
21.4 Door width self-learning
Choose F002=2:manual operation mode
Set F600=1:door width measuring
Press “OPEN” or “CLOSE” to start self-learning, after the actions of close limit, open limit,
close limit in turn, self-learning is finished.
In F602 and F603, check door width self-learning pulse number.

Note: when the encoder acquires the position signals of door open or close
limit, and door arrives at the position of door open or close limit move on to the
next step after pressing the button until door operator controller switches the torque.
21.5 Running curve commissioning.
21.5.1 Opening curve parameter instruction
21.5.1.1 For opening running curve parameter setting, see 2.6 parameter table.

21-3
MPDK136 Commissioning Manual Code:YETS-0017-C

Distance control opening curve


21.5.1.2 Distance control opening process instruction:
a. When door open command is valid, door operator accelerates to F300 setting speed in
F301 acceleration time and keeps running.
b. When door open position reaches to F604×door width, door operator accelerates to F303
setting speed in F304 acceleration time and keeps running.
c. When door open position reaches to F605×door width, door operator enters the stage of
decelerating creep. Creep speed is F305. Time of deceleration is F306.
d. When door opening position reaches to F606×door width and door close torque reaches
F307, shift to door open keeping state and output door open limit signal, and keep force torque to
be F308, now door position reset is 100%.
21.5.2 Door close curve
21.5.2.1 Door close running curve parameter setting refers to 2.6 parameter table.

21-4
MPDK136 Commissioning Manual Code:YETS-0017-C

Distance control door close curve


21.5.2.2 Distance control door close process instruction:
a. When door close command is valid, door operator accelerates to F400 setting speed in
F401 acceleration time and keeps running.
b. When door close position reaches to F607×door width, door operator accelerates to F403
setting speed in F404 acceleration time and keeps running.
c. When door closing position reaches to F608×door width, door operator starts to decelerate.
Door operator accelerates to F405 setting speed in F406 acceleration time and keeps
running.
d. When door close position reaches to F609×door width, the door operator will decelerate
again to speed F407 and keeps running. When door close torque reaches to F411, shift to
the door close keeping state and output door close limit signal, and keep torque to be F308.

e. Knife close sect. curve is not applicable to BLT door operator, F410 is set to 0.
21.6 Parameter table
21.6.1 Normal parameters

BLT
Function
Name Setting range Mini unit Setting
code
value
F0 group basic function parameters
F000 Control mode 0: magnetic flux vector control 1 1

21-5
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
1:Closed-loop vector control
Open/close door 0: Speed control mode
F001 1 1
mode selection 1: Distance control mode
0: Operation panel control mode
1: Door operator terminal control mode
Command source 2: Door operation manual commissioning
F002 1 1
selection mode
3: Door operator automatic presentation
mode
Slow speed
F006 running speed 0.00~20.00Hz 0.01Hz 7.00
setting
Carrier
F007 frequency 2.0~6.0KHz 0.1KHz 8.0
adjustment

Motor type 0: asynchronous motor


F100 1 1
selection 1: synchronous motor
Motor rated
F101 0~750W 1W 50
power
Motor rated
F102 0~250V 1V 50
voltage
Motor rated
F103 0.001A~9.900A 0.01A 1.1
current
Motor rated
F104 1.00Hz~99.00Hz 0.01Hz 24
frequency
Motor rated
F105 1~9999rpm 1rpm 180
rotating speed
Synchronous
machine encoder Setting
F114 0~359.9 0.1
zero point value
position
0: no operation
1: asynchronous machine with load tuning
F116 Motor auto 1 0
2: asynchronous machine empty load tuning
tuning
3: synchronous machine empty load tuning
21-6
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
4: synchronous machine with load tuning

Speed loop
F200 0~100 1 10
proportion gain 1
Speed loop
F201 0.01~10.00s 0.01s 0.5
integral time1
Shifting
F202 0.00~F205 0.01Hz 5.0
frequency 1
Speed loop
F203 0~100 1 10
proportion gain 2
Speed loop
F204 0.01~10.00s 0.01s 0.5
integral time2
Shifting
F205 F202~F104 0.01Hz 10.0
frequency 2
Current loop
F206 10~500 1 50
proportion gain
Current loop
F207 10~500 1 20
integral gain
Inertia
F209 0~9999 1 0
compensation
Over-excitation
F211 0~200 1 64
magnetic gain
Synchronous
machine initial
F212 0~2 1 1
position
inference mode

Speed feedback
F213 0~20 1 0
filter level

Encoder pulse
F214 1~9999 1 1024
number setting
Encoder pulse 0: forward direction
F215 1 0
direction 1: reverse direction
21-7
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
selection

Door open start


F300 0.00Hz~F303 0.01Hz 5.00Hz
low speed setting
Door open start
F301 0.1~999.9s 0.1s 0.4
acceleration time
Door open high
F303 0.00Hz~F104 0.01Hz 18.00Hz
speed setting
Door open
F304 0.1~999.9s 0.1s 0.8
acceleration time
Door open ends
F305 0.00Hz~F303 0.01Hz 2.00Hz
low speed setting
Door open
F306 0.1~999.9s 0.1s 1.0s
deceleration time
Door open limit 0.0%~150.0%
F307 torque shift point 0.0%~150.0% motor rated torque 0.1% 50.0%
setting
Door open limit
F308 0.0%~180.0% 0.1% 80.0%
torque keeping
Door open 0.0%~150.0% motor rated torque
F309 0.1% 80.0%
blocked torque
Door open start
F310 0.0%~150.0% motor rated rotating torque 0.1% 0.0%
torque
Door open
F311 blocked 0~9999ms 1ms 0ms
determined time
Door open limit
F312 0.00~F303 0.01Hz 3Hz
low speed setting

Door close low


F400 0.00Hz~F403 0.01Hz 5.00Hz
speed setting
Door close start
F401 0.1~999.9s 0.1s 0.4s
acceleration time
Door close high
F403 0.00Hz~F104 0.01Hz 18.00Hz
speed setting
21-8
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
Door close
F404 0.1~999.9s 0.1s 0.8s
acceleration time
Door close ends
F405 0.00Hz~F403 0.01Hz 1.5Hz
low speed setting
Door close
F406 0.1~999.9s 0.1s 1.0s
deceleration time
Door close limit
F407 0.00Hz~F403 0.01Hz 1.00Hz
low speed setting
Door close limit
F408 low speed 1~9999ms 1ms 100ms
running time
Knife close
F410 1~9999ms 1ms 0ms
running time
Door close limit
F411 torque shifting 0.0%~150.0% motor rated torque 0.1% 50.0%
point setting
Door close limit
F412 0.0%~F411 0.1% 30.0%
torque keeping
Door close
F413 0.0~150.0% 0.1 100.0
blocked torque
0: reserved
Door close 1: door close is blocked, only output
F414 blocked working blocked signal. 1 2
mode 2: door close is blocked, stop immediately.
3: door close is blocked, reopen.
Door close
F415 blocked 0~9999ms 1ms 500ms
determined time

Door close
F417 blocked high F418~F104 0.01Hz 12.00Hz
speed setting

Door close
F418 0.00Hz~F104 0.01Hz 2.00Hz
blocked low
speed setting

21-9
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
High speed
F419 blocked torque 0.0%~150.0% 0.1% 100.0%
setting
Low speed
F420 blocked torque 0.0%~150.0% 0.1% 100.0%
setting

Abnormal
F500 0.1~5.0s 0.1 0.3s
deceleration time
Door open time
F501 0~999.9s 0.1s 0.0s
limit
Door close time
F512 0~999.9s 0.1s 0.0 s
limit
Slow speed
F503 running time 0~999.9s 0.1s 0.0s
limit
External door
F504 open command 0~999.9s 0.1s 60.0s
delay time
External door
F505 close command 0~999.9s 0.1s 60.0s
delay time
Door open curve 0: Straight line acceleration/deceleration
F506 1 1
selection 1: S curve acceleration/deceleration
Door open
10.0%~50.0%(acceleration/deceleration
acceleration S
F507 time)(initial sect.+ incremental sect.≤90%) 0.1% 20.0%
curve initial sect.
time
Door open
acceleration S 10.0%~80.0%(acceleration/deceleration
F508 curve time) (initial sect.+ incremental sect.≤90%) 0.1% 60.0%
incremental set.
time
Door open
10.0%~50.0% (acceleration/deceleration
F509 deceleration S 0.1% 20.0%
time) (initial sect.+ incremental sect.≤90%)
curve initial sect.

21-10
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
time
Door open
deceleration S 10.0%~80.0%(acceleration/deceleration
F510 0.1% 60.0%
curve descending time) (initial sect.+ descending sect.≤90%)
sect. time
Door close curve 0: Straight line acceleration/deceleration
F511 1 1
selection 1: S curve acceleration/deceleration
Door close
acceleration S 10.0%~50.0% (acceleration/deceleration
F512 0.1% 20.0%
curve initial sect. time) (initial sect.+ incremental sect.≤90%)
time
Door close
acceleration S
10.0%~80.0% (acceleration/deceleration
F513 curve 0.1% 60.0%
time) (initial sect.+ incremental sect.≤90%)
incremental sect.
time
Door close
deceleration S 10.0%~50.0%(acceleration/deceleration
F514 0.1% 20.0%
curve initial sect. time) (initial sect.+ descending sect.≤90%)
time
Door close
deceleration S 10.0%~80.0%(acceleration/deceleration
F515 0.1% 60.0%
curve descending time) (initial sect.+ descending sect.≤90%)
sect time

Door width 0: invalid


F600 self-learning 1: door width measuring, under the mode of 1 0
function selection door operator manual commissioning, it is
valid (F002=2).

Door width
F601 self-learning 0~20.00Hz 0.01Hz 3.00Hz
speed
F602 Door width pulse 0~9999 1 0
21-11
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
number low bit
Door width pulse
F603 0~9999 1 0
number high bit
Distance control
door open start
F604 0.0%~30.0%(door width) 0.0% 10.0%
low speed running
distance
Distance control
door open
F605 60.0%~90.0%(door width) 0.1% 70.0%
deceleration
point setting
Distance control
F606 door open limit 80.0%~99.0%(door width) 0.1% 96.0%
point setting
Distance control
door close start
F607 0.0%~30.0%(door width) 0.1% 10.0%
low speed running
distance
Distance control
door close
F608 60.0%~90.0%(door width) 0.1% 70.0%
deceleration
point setting
Distance control
F609 door close limit 80.0%~99.0%(door width) 0.1% 96.0%
point setting
0~100
Fault automatic
F802 0 for no automatic reset function (reset 1 0
reset times
interval is 2s), recycling time is 1h.

On-off input
F906 1: Door open command 1 2
terminal D15
2: door close command
On-off input
F907 1 10
terminal D16
6: slow speed open/close door enable input
On-off input
F908 1 6
terminal l D17

21-12
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
Programmable
F909 relay output 1 2
TA1/TB1/TC1 3: door open limit signal output1
Programmable 4: door close limit signal output 1
F910 relay output 1 5
TA2/TB2/TC2

0:No
FP01 Parameter renewal 1:Recover factory parameter 1 0
2:Eliminate memory information

Choose binary code to select, the bit is 1


The details are as follows:
BIT0:set frequency Hz
Parameter selection of
FA00 BIT1:running frequency Hz 1 319
LED running display
BIT2:direct current bus voltage V
BIT3:output voltage V
BIT4:output current A

BIT5:output torque %
BIT6:On-off input terminal condition
BIT7:On-off output terminal condition
Parameter selection of
FA00 BIT8:door width pulse percentage 1 319
LED running display
Note: during the process of running, every
monitoring value selected by FA00 is displayable
and they shift the display of 1~511 by shift key.

0:Door open set frequency Hz


1:Door close set frequency Hz
2:direct current bus voltage V
3:On-off input terminal condition
Parameter selection of
FA01 4:On-off output terminal condition 1 39
LED shutdown display
5:door width pulse percentage
Note: during the process of shutdown, every
monitoring value selected by FA01 is displayable
and they shift the display of 1~63 by shift key.

Setting range of malfunction type:0~30


FA02 1st malfunction type 1 0
Malfunction prompting range:0~9
st
FA03 1 malfunction prompt Setting range of malfunction type 0-30 1 0
nd Prompting range of malfunction type 0-9
FA04 2 malfunction type 1 0

21-13
MPDK136 Commissioning Manual Code:YETS-0017-C

BLT
Function
Name Setting range Mini unit Setting
code
value
FA05 2nd malfunction prompt 1 0

FA06 3rd malfunction type 1 0

FA07 3rd malfunction prompt 1 0

FA08 4th malfunction type 1 0

FA09 4th malfunction prompt 1 0

FA10 Recent malfunction type 1 0

FA11 5th malfunction prompt 1 0

Bus voltage in event of


FA12 0~999.9V 0.1V 0.0V
the last malfunction

Output current in event


FA13 0.000~9.900A 0.001A 0.000A
of the last malfunction

Running frequency in
FA14 event of the last 0.00Hz~99.00Hz 0.01Hz 0.00Hz
malfunction

Output torque in event of


FA15 0.0~180.0% 0.1% 0.0%
the last malfunction

Input terminal state in 0~1023


FA16 event of the last 0:OFF 1:ON 1 0
malfunction DI8/DI7/DI6/DI5/DI4/DI3/DI2/DI1

Output terminal state in 0~15


FA17 1 0
event of last malfunction 0:OFF;1:ON; T1/T2/T3

21.6.2 Factory parameter of Monac door operator controller (only for parameter checking)
F000=1 F001=1 F002=1 F004=5.00 F005=1 F006=7.00 F007=8.0
F100=1 F101=50 F102=50 F103=1.1 F104=24 F105=180 F116=0

F200=10 F201=0.5 F202=0.5 F203=10 F204=0.5 F205=10.00 F206=50


F207=20 F208=100 F209=0 F210=0.0 F211=64 F212=1 F213=0
F214=1024 F215=0

F300=5.00 F301=0.4 F302=1.0 F303=18.00 F304=0.8 F305=2 F306=1.0


F307=50 F308=80.0 F309=80.0 F310=0.0 F311=0 F312=3

F400=5.00 F401=0.4 F402=1.0 F403=18.00 F404=0.8 F405=1.5 F406=1.0


F407=1.0 F408=100 F409=2.0 F410=0 F411=50.0 F412=30.0 F413=100.0
F414=2 F415=500 F416=10.00 F417=12.00 F418=2.00 F419=100 F420=100
21-14
MPDK136 Commissioning Manual Code:YETS-0017-C

F500=0.3 F501=0 F502=0 F503=0.0 F504=60.0 F505=60.0 F506=1


F507=20.0 F508=60.0 F509=20.0 F510=60.0 F511=1 F512=20.0 F513=60.0
F514=20.0 F515=60.0 F516=50 F517=400 F518=200

F600=0 F601=3.00 F602=0 F603=0 F604=10.0 F605=70.0 F606=96.0


F607=10.0 F608=70.0 F609=96.0 F610=0.0 F611=0 F612=0 F613=0
F614=80.0 F615=0 F616=0 F617=0 F618=30 F619=0 F620=0
F621=33

F800=1.00 F801=0 F802=0 F803=100 F804=0 F805=0 F806=0


F807=0 F808=0 F809=0 F810=12 F811=0 F812=0 F814=2.00

F900=20 F901=0 F902=0 F903=0 F904=0 F905=1 F906=2


F907=6 F908=0 F909=1 F910=2 F911=0
2.7 Malfunction diagnosis and strategy
Malfunct
Malfunction
ion Malfunction cause Treating method Note
description
display

1. Excluding external
1. Main circuit output is earthed or in
problems such as,
short circuit;
Accelerated over wirings;
Er02 2. Check whether parameter tuning
current 2. Tuning of motor
for the motor is done
parameter;
3. The load is too big.
3. Reducing sudden load.

1. Exclude external
1. Main circuit output is earthed or in problems such as,
short circuit; wirings;
Decelerated over 2. Check whether parameter tuning 2. Tuning of motor
Er03
current for the motor is done parameter;
3. The load is too big; 3. Reduce sudden load;
4. Deceleration curve is too steep. 4. Adjust curve
parameter.

1. Exclude external
problems such as
1. Main circuit output is earthed or in
wirings;
short circuit;
2. Tuning of motor
2. Check whether parameter tuning
Constant speed over parameter;
Er04 for the motor is done;
current 3. Reduce sudden load;
3.The load is too big;
4. Choose suitable
4. Too much disturbance of rotation
rotating encoder, use
encoder.
shielding rotation
encoder wire.

21-15
MPDK136 Commissioning Manual Code:YETS-0017-C

Malfunct
Malfunction
ion Malfunction cause Treating method Note
description
display

1. Adjust input voltage;


1. Input voltage is too high; 2. Choose suitable
Accelerated over
Er05 2. Braking resistor is too big; braking resistor;
voltage
3. Acceleration curve is too steep. 3. Adjust curve
parameter.

1. Adjust input voltage;


1. Input voltage is too high; 2. Choose suitable
Decelerated over
Er06 2. Braking resistor is a little big; braking resistor;
voltage
3. Deceleration curve is too steep. 3. Adjust curve
parameter.

1. Adjust input voltage;


Constant speed over 1. Input voltage is too high;
Er07 2. Choose suitable
voltage 2. Braking resistor is too big.
braking resistor.

1. Momentary power failure of input 1. Exclude external Reset after


Low-voltage power supply; power problem; voltage returns
Er09
protection 2. Input voltage is too low; 2. Please contact with to its normal
3. Abnormality of control board. agent or manufacturer. state

1. No sundry in elevator door guide 1. Check elevator door


Er10 System overload rail; guide rail;
2. The load is too big. 2. Reduce load.

1. Main circuit output wiring is 1. Check wiring ;


Default phase on Slow down and
Er13 loosened; 2. Exclude motor
output side stop
2. Motor is damaged. malfunction.

Slow down and


1. Reduce ambient
1. Ambient temperature is too high; stop, reset after
temperature;
Er14 Module overheating 2. Fan is damaged; the temperature
2. Clean the air flue;
3. Air flue is blocked. returns to its
3. Change fan.
normal state

EEPROM Abnormality of EEPROM Please contact with agent


Er16
malfunction reading-writing. or manufacturer.

Current detection Please contact with agent


Er18 Abnormality of drive control board.
malfunction or manufacturer.

1. Input motor parameter


correctly;
1. Motor parameter setting is wrong;
2. Check motor lead;
Motor adjustment 2. Parameter adjustment is overtime;
Er19 3. Check rotating encoder
overtime 3. Synchronous machine rotating
wiring, and ensure that
encoder is abnormal.
settings of pulse per
revolution is correct.
21-16
MPDK136 Commissioning Manual Code:YETS-0017-C

Malfunct
Malfunction
ion Malfunction cause Treating method Note
description
display
1. Choose ABZ phase
rotating encoder, which
1. Whether rotating encoder type
Rotating encoder is in open circuit and
Er20 matches;
malfunction collecting electrode;
2. Rotating encoder wiring error
2. Exclude wiring
problems.
1. Set a relatively long
door open time limit,
ensure that F500 is bigger
than the sum of door open
time;
1. Door open time limit (F500) is
2. Set a relatively long
smaller than total door open time;
door close operation time,
2. Door close time limit (F501) is
ensure that F501 is bigger
smaller than total door close time;
than the sum of door
3. When door width is in Only
close time;
Parameter setting self-learning, order source (F002) is prompting, no
Er26 3. When door width is in
prompting not set to manual debugging mode, malfunction
self-learning condition,
or door open and close selection record
order source (F002) is in
(F001)is not distance control way;
manual debugging mode,
4. Choose vector flux control way
or choose (F001) distance
(F000), when drive synchronous
control way to open and
machine is used.
close door;
4.When controlling
synchronous machine
(F100), select vector
control way (F000).
1. Check encoder wiring
and the relevant
1. Data of door width obtained by parameters;
Door width
self-learning is smaller than 20; 2. Check door operator
Er27 self-learning
2. Before door width self-learning, mechanical system;
malfunction
do the distance control running. 3. Before distance
control running, do door
width pulse self-learning.
1. Open limit signal malfunction or 1. Check door open limit
Er28 Open door overtime setting mistake; signal; Automatic reset
2. Pulse encoder wiring was broken. 2. Check encoder wiring.
1. Motor running direction is 1. Change the phase
Automatic
Er29 Close door overtime contrary to door open definition; sequence of motor wiring
reset
2. Door close limit signal or set F004=1;

21-17
MPDK136 Commissioning Manual Code:YETS-0017-C

Malfunct
Malfunction
ion Malfunction cause Treating method Note
description
display
malfunction or setting mistakes; 2. Check door close limit
3. Pulse encoder wiring was broken. signal;
3. Check encoder wiring.
1. Signal malfunction of open limit 1. Check close limit
Slow open and close Automatic
Er30 and close limit or setting mistakes; signal;
door is overtime reset
2. Pulse encoder was broken. 2. Check encoder wiring.
1. Check whether
sundries are in the rail;
2. Check whether the
1. Sundries in the rail; upper limit of open door
Door open being Automatic
Er31 2. Unreasonable parameter setting torque is reasonable;
blocked protection reset
for door open being blocked. 3. Check whether
judging time for door
open being blocked is
reasonable.
1. Acceleration and deceleration is too 1. Enlarge acceleration
urgent; and deceleration;
Speed deviation 2. Learning mistake of motor angle 2. Do angle self-learning
Er32
protection leads to galloping; again;
3. Speed deviation was set relatively 3. Change the value of
small, time is a relatively short. F516, F517.
Now, according
1. Check whether door to encoder
close limit switch is signal, door
installed, if not, please operator could
cancel the corresponding be in normal
When limit switch is used under
Door close limit input point settings; running, after
Er33 distance control mode, this switch
switch abnormality 2. Check whether wiring door close limit
signal is not detected during the
of door close limit switch switch returns
process of door close.
is correct; to its normal
3. Check if door close state, this fault
limit switch was broken. could be
eliminated.

21-18
MPDK136 Commissioning manual Code:YETS-0017-C

23 Community monitoring instruction


Community monitoring is designed for users, debugging and maintenance personnel to
adjust, monitor and control the elevator. It has the functions of monitoring running status of the
elevator in real time such as fault, running direction, and current car status and door state,
recording monitored information in real time, individually controlling single elevator such as
call, firefighting, elevator locking and fault reset and analyzing historical record.
The system should be used in elevator connection condition or off-line working to view
previous saved record.

23.1 Hardware equipment


MCTC-MIB-A community monitoring information collection board is used to query
elevator running status, current floor and fault information. The information is transmitted to
monitoring room through communication method. PC machine with monitoring software in
monitoring room can monitor and control the elevator.

23-1
MPDK136 Commissioning manual Code:YETS-0017-C

23.2 Equipment connection

The above picture is for equipment connecton. Every integrated machine in machine room
is equipped with a community monitoring board. Every PC machine in monitoring room is
equipped with a community monitoring board. 485 method communications shall be used
between integrated machine and monitoring room. Every control board of monitoring room
connects 24 monitoring boards of integrated machine at most.
23.3 Wiring setting instruction for community monitoring board
1)J11 is used for connecting upper computer; single plate in monitoring room connects
computer serial port; single plate in machine room connects NICE3000.

23-2
MPDK136 Commissioning manual Code:YETS-0017-C

2)J12 is used for 485 communication networking. MOD+ of MIB in monitoring room and
machine room shall be in interconnection, and MOD- shall be in interconnection too.
3)J14 and J15 are matched termination. J14 and J15 in single plate in monitoring room shall
connect to ON, but J14 and J15 in single plate in machine room shall connect to OFF.
4)Implication of indicator light
A、OK: Single plate power supply and singlechip run normally
B、S1:Upper machine communicates normally
C、S2:485 networking communicate normally.
Function codes related to community monitoring are shown as follows

Function code Name Setting range Note


MIB of monitoring
room is set to 200;
F0-02 Local address 0~255; MIB of machine room
is set to 1-24 as
required
0:9600bps Set MIB of
1:19200bps monitoring room and
F0-03 Upper machine Baud 2:38400bps Baud rate of computer
rate setting serial port
3:57600bps
communication
4:115200
Set single elevator
quantity monitored by
Monitor single MIB of monitoring
F0-06 1~24
elevator quantity room; MIB of
machine room need
no setting

23.4 Wiring
In view of actural application working condition and 485 bus characteristics it is
recommended that wiring scheme is shown as follows:

23-3
MPDK136 Commissioning manual Code:YETS-0017-C

(1)Party A lays bus and branch cables: four core shielded wire, every two wires are winded
together, wire diameter at least 0.75MM²
(2)A repeater is added for each additional 350 meters exceeding bus cable length, every
repeater works for at most six elevators; the branch cable length of every elevator is not more
than 140 meters
(3)Community monitoring quanity n≤24 units, at most three repeaters are equipped.
(4)Community monitoring board machine room OV, monitoring room OV and repeater OV
need to be connected reliably.
(5)Upper machine is provided by party A, which is equipped with COM port (serial port)
(6)Integrated machine CAN5 is DB9 communication interface and community monitoring
can’t exist with IOT function.
23.5 Software application
1. Running
Double click the folder SoftResoure next to NEMCS.exe to make it be programme run resource
file which shall be in the same folder with NEMCS.exe.

2. Log in interface:

Picture 2
Enter correct user name and password and factory setting: user name is user and password is
user. (If you enter wrong password for five continuous times, programme will not accept any
user login before quitting)
After login dialog box will automatically pop out indiating the configuration of serial port and
connection.

23-4
MPDK136 Commissioning manual Code:YETS-0017-C

picture 4
3. Grouping setting
After logging in skip the interface:

Picture 6
Function
(1) Obtain the elevator information
Automatically scan current elevator and record the scanned information to the database and
display it in the listbox.
(2)Click the elevator in the list.
Modify the name, grouping, group name and code of current elevator to distinguish the
elevators.
(3)Click the elevator in the list.
Modify specific floors display of current elevator
(4) Delete the selected elevator
Delete history record information of the elevator

23-5
MPDK136 Commissioning manual Code:YETS-0017-C

4. Whole display

Picture 8

Function:
a. Display elevators according to the setting of grouping setting
b. Display elevator running status, current floor and other information in real time; at the same
time record call and fault information in the database.
c. Fault, connection failure can be displayed in red.
d. Display at most 10 groups at the same time, monitor 32 elevators at most in real time.
e. Click the icon which represents the elevator, skip to control interface of the elevator but it will
result in software stopping monitoring other elevators in real time. The software only monitors
the elevator. The processing is to speed up communication.

5. Single elevator display

Picture 10
23-6
MPDK136 Commissioning manual Code:YETS-0017-C

Function:
(1)Elevator simulation shaft is on the left side. When the elevator runs, the elevator current
position will be dynamically displayed in this place.
(2)Elevator current status information is displayed in middle listbox and updated in real time.
(3)On the right side of the upper is car call information, the lower is for hall call information.
When outline border of car call is blue, it shows the floor where the elevator is. If it turns red, it
shows designated floors of car call. Hall call is shown in triangles. Designated calls are also
shown in red.
(4)Fault reset: Eliminate the fault with lower level
(5)Firefighting: Set the elevator in firefighting status, click again to cancel.
(6) Elevator locking:Set the elevator in locking state, click again to cancel
(7) At the top of left side displays current elevator group name and elevator name.

6. Record analysis / system setting


Record analysis
Choose record time period needed for analysis through start or end time
(1)Fault display

Classify according to fault type

Picture 12

Query the elevator according to fault type

23-7
MPDK136 Commissioning manual Code:YETS-0017-C

Picture 14

(2)Fault statistics
Choose two display methods of listing and pie chart according to elevator statistics.

Picture 16

23-8
MPDK136 Commissioning manual Code:YETS-0017-C

Choose two display methods of listing and pie chart according to fault types.

Picture 18
(3)3000 fault help
Failure level and processing method will be displayed on the right side after choosing
corresponding fault number and name on the left side.

Picture 20

23-9
MPDK136 Commissioning manual Code:YETS-0017-C

2. Software setting
(1) User information setting
Newly created user
Change the password
Delete the user

Picture 22
(2) Program language setting and system data compression
Output Excel of software current language, the user can translate native language and import
into the software to realize language replacement.

Picture 24

Replace the welcome screen / Log


Save the picture Log used in the program in the file Pic under the folder SoftResource. User can
replace the picture as required, but must ensure that the name, path and format are not changed.
LoadPic.jpg is login interface
LogoPic.jpg is Log picture
It is recommended to replace the picture with the same size as the original picture or the picture
with similar proportion, in order to avoid image stretching or enlarged fuzzy distortion.
23-10
MPDK136 Commissioning Manual Code:YETS-0017-C

24. Car sterilization function debugging


24.1 Function instruction
Car is equipped with ultraviolet ozone sterilization device. The control system of the elevator
controls the device to conduct regular and reliable sterilization to make it a sterile car and prevent
the patients from secondary infection and cross infection.
24.2 Parameters setting
Function
Name Setting range Default Note
code
Medical
A1-12 sterilization 00.00~23.59 0 HH.MM
start time
Medical
A1-13 sterilization end 00.00~23.59 0 HH.MM
time

F5-29(Y4 function selection)is set to 19(medical sterilization control)starting car sterilization


function. Start the sterilization for car when system time reaches A1-12 setting time and elevator
is in no use and end the sterilization when system time reaches A1-13 setting time.

24-1
MPDK136 Commissioning Manual Code:YETS-0017-C

25 Instructions for BLT Internet of Things


25.1 Hardware equipment
A module DTU(MD-309 DTU), a serial port line RS232 (integrated in module DTU), a
power adapter (integrated in module DTU), a antenna GSM (integrated in module DTU)
25.2 Operation method
(1)Use a small screwdriver or other tools to press the small white button next to SIM slot of
module DTU util the slot is popped out, as follows:

White button

Picture 1
(2)Put SIM card into the card slot and set it in the module DTU (directly press it to enter)
shown in picture 2.

Picture 2
(3)Fix the module DTU to frequency conversion cabinet or hoistway wall. When installing
frequency conversion cabinet use 3M tape to stick or bore in cabinet and fix by screws. When
MPDK136 Commissioning Manual Code:YETS-0017-C

installing in the hoistway bore in proper position of the wall and fix the module DTU to the wall.
After installation of the module DTU connect the interface RS232 of the module DTU with the
interface CN5 of main controller(RS232)by connecting line RS232 and tighten the screw as
follows in picture 3.

Picture 3
(4)External antenna shall be placed in the position where GPRS signals can be received.
Connect external antenna with the interface SMA of module DTU and tighten. Connect power
adapter to module DTU as follows in picture 4. The plug of power adapter shall be plugged into
power strip.

Picture 4
MPDK136 Commissioning Manual Code:YETS-0017-C

(5)After power-on indication state of DTU red light and green light are shown as table 1:
Table 1: Description for DTU indication light
LED indication Colour State Description
light
On line Green Always on Be connected to data center
Off Not be connected to data
center
Fast flicker Being connected to data center
Slow flicker Dailing
Send Red Flicker Transmitting data/standby
Off No data transmitted

Note: when green light is always on and red light flickers, it shows that Internet of Things has
been connected successfully and no further debugging needs to be done.
MPDK136 Commissioning Manual Code:YETS-0017-C

26-F07.04 version applications upgrading additional function parameters and


commissioning method
26.1 Electric instruction
The commissioning manual is suitable for F07.04 version of MPDK136 system main
controller.
The following content is added to the applications.
(1)Relevant content of UCMP
(2)Pulse stop function
(3)Operator readable interface
26.2 Function parameter addition list

Function
Parameter instruction Setting range Default value
code

F2-37 Test duration of moment 1-10 seconds, it is 5S when it is set to be 0. 0

F2-38 Test moment amplitude 110~150% motor rated moment 110

F2-39 Test pulse count when there is 1~20 encoder feedback pulse; it is 3 pulse by default when it
0
something wrong. is set to be 0.

F2-40 Monitoring value of sliding


1~20 degree host machine rotation mechanical angle 0
distance being overlarge

F3-24 UCMP test 0:no state 2:start test function 0

Main controller low voltage 81: door lock short circuit detecting point (low voltage) 0
F5-1~23
input point

07:door lock short circuit detecting point (high voltage)


Main controller high voltage 6
F5-39
input point

F7-09 Brake moment detection result 0:meaningless 1:qualified 2:unqualified 0

Brake moment detection 0~1440 minute 1440


F7-10
countdown

Braking force detection BIT8 Startup when it is set to 0; Shutoff when it is set to 1. 0
F8-19
function

26-1
MPDK136 Commissioning Manual Code:YETS-0017-C

UCMP function BIT9 Startup when it is set to 0; Shutoff when it is set to 1. 0

Braking force detection


BIT13 Startup when it is set to 0; Shutoff when it is set to 1. 0
buzzing prompting

Door lock line breaking


BIT14 Startup when it is set to 0; Shutoff when it is set to 1. 0
detection function

Return leveling pulse stop


BIT2 Startup when it is set to 0; Shutoff when it is set to 1. 0
function

A1-10 Reveliing pulse stop function BIT3 Startup when it is set to 0; Shutoff when it is set to 1. 1

Pulse releveling predicted


BIT4 Startup when it is set to 0; Shutoff when it is set to 1. 0
value

Function code Parameter instruction Setting range Default value

Button flashes under the


BIT5 Startup when it is set to 0; Shutoff when it is set to 1. 0
function of security floor

A1-10
Door lock detection function
during initial power-on door BIT6 Startup when it is set to 0; Shutoff when it is set to 1. 1
open

Pulse releveling estimate


A1-16 0~200mm 0
adjustment amount

Half the length of leveling


A1-17 Read only Read only
plate

Braking force manual


A1-19 BIT0 Shutoff when it is set to 0; startup when it is set to 1. 0
detection

26.3 Function instruction and commissioning method

26.3.1 Function 1: UCMP

(1)UCMP detection method: door zone signal change from effective to ineffective is detected by
controller. At the same time door lock signal disconnects, if the elevator displacement exceeds
5cm, the elevator will report E65——UCMP fault and stop running.

26-2
MPDK136 Commissioning Manual Code:YETS-0017-C

Test condition: inspection switch is effective, the elevator stops in door zone, and the door lock
keeps closed.

Test method:

1) It is tested under the condition of effective inspection switch, door lock being closed in door
zone.

2)Main control board small keyboard trigger method: when F-8 on small keyboard is set to 7, it
will display E88, start up UCMP test function, disconnect door lock circuit, and namely pull out
the inserter XP16 in the control cabinet.

Handheld operator trigger method: when F3-24 is set to 2, it will display E88; start up UCMP test
function, at this time disconnects door lock circuit.

3)Manually press the up run or down run button, sealed door contactor output, door lock short
circuit, the elevator normally starts running in inspection state.

4)After the elevator gets away from door zone, safety circuit board will cancel door lock short
circuit, at this time the elevator will report E65(UCMP fault), and stop running.

Other instruction:

1) When the elevator is not in inspection state or door zone or door lock is not effective, it is not
effective to set F-8 to 7 and F3-24 to 2.

2)After F-8 is set to 7 or F3-24 is set to 2, automatically zero clearing after running once, and
automatically zero clearing after power-off.

2) Under the module of UCMP test, start acceleration curve in accordance with acceleration
F3-08. Set acceleration start time to 1.0s, end time to 1.0s to ensure average start speed is
more than 0.5m/s. If average speed is less than 0.5m/s, it can be realized by increasing
F3-08special deceleration and F3-11 inspection speed.

Reset condition:

1) E65 fault cannot automatically reset. Automatic reset cannot be done if power on after power
off.

2) Manual reset can be done in the state of inspection.

(2)Door lock short circuit detecting point: increase high voltage input point: 07 door lock short
circuit detecting point; low voltage input point: 81 door lock short circuit detecting point.

Door lock short circuit detection function

1) After door open output for three seconds, the elevator detects door lock short circuit signal is
effective, and reports E53 fault (low voltage subcode 105 high voltage 106), the elevator
cannot run, the fault need manual reset.
26-3
MPDK136 Commissioning Manual Code:YETS-0017-C

2) When the elevator opens door, the system outputs door sealing signal or when sealed door
contactor is output during pre-opening or releveling, time delay 2s, door lock short circuit signal
is detected, if it is abnormal, the elevator will report E53 fault (subcode 107), fault needs to be
reset manually.

3) If door lock short circuit point is chosen, but connection or disconnection time does not reach 1
second, after door close limit, E53 fault is prompted and character code 108, fault needs to be
manually reset, BIT14 of function code F8-19 can close the function and start by fault.

(3)Braking force self-monitoring function: synchronous machine can start the function when the
requirements of the first modification sheet of GB/T7588 are met. Asynchronous machine doesn’t
need startup.

Manually test braking force

1) In the state of inspection set control board small keyboard F-8 to 8, or set handheld operator
big keyboard A1-19Bit0 to 1. Test can be conducted when controller small keyboard displays
E88. At this time, the elevator shields car and hall calls and door opening, keep door lock
connected, and automatically close the door if the door is not closed.

2) After the door lock is effective, begin the test to make sealed star contactor, running contactor
output, and brake contactor not output.

3)F7-09 displays the test result. 1 stands for being qualified, 2 for being unqualified. Report E66
when it is not modifiable and unqualified and the fault cannot be reset. Fault reset: it is needed
that braking force detection is done again, and it cannot reset until the result is 1.

4)Hall call and door function revert to normal when the detection is finished.

Automatically detect the braking force

Condition1: elevator normal braking force detection: under the condition of no car and hall calls,
detection is conducted after elevator energy saving time or three minutes.

Condition 2: mandatory braking force detection: judge 10 minutes in advance, time of F7-10 is
not more than 10 minutes. Elevator buzzing prompt time is 30S. Buzzing can be off by BIT13 of
function code F8-19. After 30S, hall call registration is retained but car call is canceled. Door
open and close can be available. Begin detection after closing door.

Setting of braking force detection

Count down function, the unit is minute, judge whether it meets the condition 1 when
exceeding 12 hours. If the detection is done, countdown function code reset 24 hours; if the
detection is not done, mandatory detection is done in condition 2.

1、 During detection hall call prompts fault, big keyboard does not prompt the fault and small
keyboard prompts fault. Hall call can be registered but cannot respond; car call is canceled and
26-4
MPDK136 Commissioning Manual Code:YETS-0017-C

door open and close cannot be done.

26.3.2 Function 2: pulse stop function

To make elevator stop more accurately during releveling and return leveling, add the function.
Pulse return leveling is on by default, and pulse releveling is off by default.

First function code A1-16 is pulse stop estimate adjustment whose unit is mm and modifiable.
A1-17 is half the length of leveling plate, Read Only and taken as reference (obtained by self
learning). The value A1-16 is the value A1-17 minus 10 and can be self-adjusted on site. When
BIT2 of A1-10 is 0, return leveling pulse stop function is on by default, when BIT2 of A1-10 is 1,
return leveling pulse stop function is off by default. When BIT3 of A1-10 is 1, releveling pulse
stop function is off by default, when BIT3 of A1-10 is 0, return leveling pulse stop function is on
by default. When BIT4 of A1-10 is 0, A1-16 predicted value function is on by default, when BIT4
of A1-10 is 1, predicted value adjustment is off by default.

26.3.3 Function 3: readable interface on operator

To observe the parameters directly such as running speed, direction, floor and so on during
manual opening brake and sliding test, add several groups of parameters which shall be easy to
observe and understand and can be operated by unprofessional persons.

Check method is shown as follows:

(1) For example, the elevator on first floor starts running up, after inserting the operator in the
state of leveling, press the key “enter”, LED4 will display running direction, up run is
shown as the following picture, LED3 will display leveling signal, LED2 will display high
level of current floor,and LED1 will display low level of current floor.

(2)After pressing the key “enter” again, enter display interface of elevator speed.

26-5
MPDK136 Commissioning Manual Code:YETS-0017-C

Elevator actual speed is displayed as shown in the picture.

(3)After pressing the key “enter” again, enter display interface of elevator running frequency,
first display low level and then display high level after pressing the key “enter” again.

(4)After pressing for four times, exit newly increased interface, and press the key “enter” to
cycle previous display.

26-6

You might also like