You are on page 1of 9

4.

2 Loading (NSCP 2015)


Computation of Loads Third Floor
Deadload
Masonry Walls
Exterior Walls Pressure Load Height Member Load
150 mm thick 2.97 3 8.91 kN/m
Plaster Faces : 2 0.24 3 1.44 kN/m
Total Load 10.35 kN/m
Interior Walls Pressure Load Height Member Load
100 mm thick 2.84 3 8.52 kN/m
Plaster Faces : 2 0.24 3 1.44 kN/m
Total Load 9.96 kN/m

Concrete Slab
Thickness Unit Weight Pressure Load
125 mm thick slab 0.125 23.6 2.95 Kpa
Floor Finish - - 1.1 Kpa
Ceiling - - 0.1 Kpa
MEP - - 0.1 Kpa
Total Load 4.25 Kpa
Concrete Slab with Movable Partition
Thickness Unit Weight Pressure Load
125 mm thick slab 0.125 23.6 2.95 Kpa
Floor Finish - - 1.1 Kpa
Ceiling - - 0.1 Kpa
MEP - - 0.1 Kpa
Movable Partitions - - 0.24 Kpa
Total Load 4.49 Kpa

References:

Liveload
CATEGORY DESCRIPTION UNIFORM LOAD (KPA)
Business Practicing Office 2.9
OFFICE Lobbies 4.8
Other Offices 2.4
DEPARTMENT STORE - 2.4
RESTROOM - 2.4
HALLWAY - 4.8
Computation of Loads Roof Deck
Deadload
Masonry Walls
Exterior Walls Pressure Load Height Member Load
150 mm thick 2.97 3 8.91 kN/m
Plaster Faces : 2 0.24 3 1.44 kN/m
Total Load 10.35 kN/m
Interior Walls Pressure Load Height Member Load
100 mm thick 2.84 3 8.52 kN/m
Plaster Faces : 2 0.24 3 1.44 kN/m
Total Load 9.96 kN/m

Concrete Slab
Thickness Unit Weight Pressure Load
125 mm thick slab 0.125 23.6 2.95 Kpa
Floor Finish - - 1.1 Kpa
Ceiling - - 0.1 Kpa
MEP - - 0.1 Kpa
Total Load 4.25 Kpa
Concrete Slab with Movable Partition
Thickness Unit Weight Pressure Load
125 mm thick slab 0.125 23.6 2.95 Kpa
Floor Finish - - 1.1 Kpa
Ceiling - - 0.1 Kpa
MEP - - 0.1 Kpa
Movable Partitions - - 0.24 Kpa
Total Load 4.49 Kpa

References:

Liveload
CATEGORY DESCRIPTION UNIFORM LOAD (KPA)
WATER TANK - 11
HALLWAY - 4.8
SEISMIC FORCE DESIGN CONSIDERATION

I. Location: LUCOD, BAGANGA, DAVAO ORIENTAL

Nearest Fault Line: 40.4 km


Fault Name: Caraga River
Segment Name: Caraga River Segment

II. Occupancy Category: III Special Occupancy Structure


The proposed 3 storey commercial building lies with Special Occupancy
Structure that can occupy 1000 person or more I assembly room.
NSCP 2015 Section 103.1 (Table 103-1)

III. Seismic Importance Factor: 1.00


Type III Special occupancy Structure falls with 1.00 Seismic Importance Factor.

NSCP 2015 Section 208.4.2 (Table 208-1)

IV. Soil Profile Type: Sd


NSCP 2015 Section 208.4.3 permits the use of Soil Type Sd when the soil
properties are not known in sufficient detail to determine the soil profile type. Hence, the
location is assumed to be Soil Type Sd.

NSCP 2015 Section 208.4.3 (Table 208-2)

V. Seismic Zone: Zone 4

NSCP 2015 Section 208.4.4.1 (Table 208-3)

VI. Seismic Zone Factor: z=0.40


Baganga, Davao Oriental falls under Zone 4. Therefore, the proposed 3 storey
commercial building is in zone 4, it corresponds with the Seismic Zone Factor Of
0.40. NSCP 2015 Section 208.4.4.1 (Table 208-3)

VII. Seismic Source Type: Type A


Since the earthquake in history occurred in Davao City was 8.3 magnitude,
therefore it belongs to Type A.

NSCP 2015 Section 208.4.4.2 (Table 208-4)

VIII. Near Source Factor, Na: Na=1.0


The closest distance to known seismic source is 1.6km which is less than 2km.
Hence, NSF is 1.0.

NSCP 2015 Section 208.4.4.3 (Table 208-5)

IX. Near Source Factor, Nv: Nv= 1.0


The closest distance to know seismic source is 1.6km. Hence, the factor is 1.0 for
seismic source type A.

NSCP 2015 Section 208.4.4.3 (Table 208-6)

X. Seismic Coefficient, Ca: Ca=0.44

Ca=0.44Na=O.44(1.0)=0.44
NSCP 2015 Section 208.4.4.4 (Table 208-7)

XI. Seismic Coefficient, Cv: Cv=0.64Nv=0.64


Cv=0.64Nv=0.64(1) =0.64
NSCP 2015 Section 208.4.4.4 (Table 208-8)

XII. Structural System: In this consideration, the structural system of a proposed


commercial building is Moment Resisting Frame Systems: Special Reinforced
Concrete Frames.
NSCP 2015 (Table 208-11A)

XIII. Numerical Coefficient, R: R=8.5


Based on the details in previous consideration about structural system, it will be the
basis for the value of numerical coefficient. The value of R is 8.5.
Wind Load Consideration
I. Location: LUCOD, BAGANGA, DAVAO ORIENTAL

II. Occupancy Category

III. Wind Speed

V=320 km/h

IV. Exposure Category

You might also like