You are on page 1of 2

Proposed Development Rubicon Innovative Engr Ltd (*189-5E9H-R3LH-NBPC)

COLUMN REINFORCEMENT DESIGN Orion Building Design System 18.0 (04.2012) / Page: CD-1

1-A (1C1) Storey: 1 (Con.:C16/20 / Steel:Grade 380 (Type 2))


Loadings (Combination):
No N (Bot) M1 (Bot) M2 (Bot) N (Top) M1 (Top) M2 (Top)
1 183.2 -4.0 3.7 177.3 7.7 -7.6
2 144.4 -3.9 1.5 138.5 7.6 -3.1
3 183.2 -4.1 3.7 177.3 7.7 -7.6
4 155.0 -2.4 4.1 149.2 4.4 -8.6
5 183.2 -4.0 3.7 177.3 7.7 -7.6
6 187.1 -4.0 4.2 181.2 7.6 -8.5
7 183.2 -4.1 3.7 177.3 7.7 -7.6
8 119.7 -2.4 1.4 113.8 4.5 -3.1
9 183.2 -4.0 3.7 177.3 7.7 -7.6
10 175.8 -3.9 3.7 169.9 7.5 -7.6
11 183.2 -4.1 3.7 177.3 7.7 -7.6
12 151.6 -0.5 3.7 146.5 3.7 -6.9
13 157.1 -6.2 2.4 152.1 9.1 -5.7
14 155.5 -2.9 5.5 150.4 6.0 -8.6
15 153.2 -3.8 0.6 148.2 6.8 -4.0
Critical Combination:13 - (G+Q-Nx)
Min Design
N (kN) 157.1 - 157.1
M1 (kN.m) 9.1 1.8 13.8
M2 (kN.m) -5.7 -1.8 0.0 225
N-max (kN) 0.0
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5 Short Column...
N/bhFcu = 0.155 Le1/b1 = 10.2 < 15.0 225
Beta = 0.82 Le2/b2 = 10.2 < 15.0
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(1/2)= 3.3 / 3.7 kN As (Required): %0.40 (min) 202.50 mm2 4Y16
vc'(1/2)= 0.90 / 0.90 N/mm2 As (Provided): %1.59 804.25 mm2
v (1/2)= 0.08 / 0.09 N/mm2
Links = Y10-175

1-A (2C1) Storey: 2 (Con.:C16/20 / Steel:Grade 380 (Type 2))


Loadings (Combination):
No N (Bot) M1 (Bot) M2 (Bot) N (Top) M1 (Top) M2 (Top)
1 47.5 -8.9 10.3 41.9 6.9 -8.7
2 40.7 -8.8 5.1 35.1 6.9 -5.3
3 47.5 -8.9 10.3 41.9 6.9 -8.7
4 42.1 -5.2 11.2 36.5 4.5 -9.1
5 47.5 -8.9 10.3 41.9 6.9 -8.7
6 47.3 -8.9 11.1 41.6 6.9 -8.8
7 47.5 -8.9 10.3 41.9 6.9 -8.7
8 41.9 -5.3 6.1 36.2 4.5 -7.4
9 47.5 -8.9 10.3 41.9 6.9 -8.7
10 41.2 -8.8 9.4 35.6 6.9 -7.0
11 47.5 -8.9 10.3 41.9 6.9 -8.7
12 40.2 -6.0 8.6 35.4 4.5 -7.4
13 41.2 -8.9 8.6 36.4 7.1 -7.4
14 41.0 -7.4 9.4 36.2 5.8 -8.2
15 40.4 -7.5 7.8 35.6 5.9 -6.6
Critical Combination:6 - ((G+Q)P31 *F)
Min Design
N (kN) 47.3 - 47.3
M1 (kN.m) -8.9 -0.5 0.0
M2 (kN.m) 11.1 0.5 19.5 225
N-max (kN) 0.0
Concrete Cover =25.0 mm
BS8110-Cl.3.8.4.5 Short Column...
N/bhFcu = 0.047 Le1/b1 = 9.6 < 15.0 225
Beta = 0.94 Le2/b2 = 9.6 < 15.0
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(1/2)= 4.8 / 6.2 kN As (Required): %1.11 560.51 mm2 4Y16
vc'(1/2)= 0.81 / 0.81 N/mm2 As (Provided): %1.59 804.25 mm2
v (1/2)= 0.12 / 0.15 N/mm2
Links = Y10-175

Project: BINO_HOTEL
Proposed Development Rubicon Innovative Engr Ltd (*189-5E9H-R3LH-NBPC)
COLUMN REINFORCEMENT DESIGN Orion Building Design System 18.0 (04.2012) / Page: CD-2

6-C (1C18) Storey: 1 (Con.:C16/20 / Steel:Grade 380 (Type 2))


Loadings (Combination):
No N (Bot) M1 (Bot) M2 (Bot) N (Top) M1 (Top) M2 (Top)
1 148.3 0.3 -1.9 136.6 -1.1 3.3
2 131.2 -0.4 -2.1 119.4 0.2 4.3
3 149.4 0.3 -1.8 137.7 -1.1 3.2
4 128.9 0.7 -0.7 117.1 -1.5 0.6
5 135.6 0.5 -2.1 123.9 -1.4 3.8
6 130.1 0.1 -1.3 118.4 -0.5 2.6
7 149.4 0.3 -1.8 137.7 -1.1 3.2
8 140.0 0.6 -1.6 128.3 -1.6 1.9
9 135.6 0.5 -2.1 123.9 -1.4 3.8
10 138.3 -0.1 -1.8 126.5 -0.2 3.7
11 149.4 0.3 -1.8 137.7 -1.1 3.2
12 119.5 5.2 1.5 109.5 -5.6 0.8
13 130.4 -4.7 -4.7 120.3 3.8 4.7
14 133.4 0.9 15.6 123.3 -1.1 -11.2
15 116.5 -0.4 -18.9 106.5 -0.7 16.8
Critical Combination:1 - (G+Q *F)
Min Design
N (kN) 148.3 - 148.3
M1 (kN.m) -1.1 -1.7 -3.0
M2 (kN.m) 3.3 3.0 0.0 450
N-max (kN) 0.0
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5 Short Column...
N/bhFcu = 0.073 Le1/b1 = 10.2 < 15.0 225
Beta = 0.91 Le2/b2 = 5.2 < 15.0
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(1/2)= 0.1 / 0.2 kN As (Required): %0.40 (min) 405.00 mm2 6Y16
vc'(1/2)= 0.71 / 0.59 N/mm2 As (Provided): %1.19 1206.37 mm2
v (1/2)= 0.00 / 0.00 N/mm2
Links = Y10-175

6-C (2C18) Storey: 2 (Con.:C16/20 / Steel:Grade 380 (Type 2))


Loadings (Combination):
No N (Bot) M1 (Bot) M2 (Bot) N (Top) M1 (Top) M2 (Top)
1 77.8 3.8 3.6 66.6 -5.6 -17.8
2 67.2 2.4 2.9 56.0 -4.5 -18.0
3 78.7 3.7 4.3 67.5 -5.5 -18.5
4 66.6 3.1 3.4 55.3 -4.1 -11.3
5 77.1 4.2 3.6 65.9 -5.9 -18.0
6 63.6 2.5 1.8 52.4 -3.9 -11.8
7 78.7 3.7 4.3 67.5 -5.5 -18.5
8 73.7 3.9 5.1 62.4 -5.4 -18.5
9 77.1 4.2 3.6 65.9 -5.9 -18.0
10 74.4 2.9 3.0 63.1 -4.9 -16.8
11 78.7 3.7 4.3 67.5 -5.5 -18.5
12 65.5 4.9 2.7 55.9 -6.5 -15.4
13 66.6 1.4 3.4 57.0 -2.9 -14.6
14 67.5 2.7 5.8 57.9 -4.5 -19.5
15 64.6 3.7 0.2 55.0 -5.0 -10.5
Critical Combination:12 - (G+Q+Nx)
Min Design
N (kN) 65.5 - 65.5
M1 (kN.m) -6.5 -0.7 0.0
M2 (kN.m) -15.4 -1.3 -28.9 450
N-max (kN) 0.0
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5 Short Column...
N/bhFcu = 0.032 Le1/b1 = 9.6 < 15.0 225
Beta = 0.96 Le2/b2 = 4.9 < 15.0
M-add(1/2)= 0.0 / 0.0 kN.m
Vd(1/2)= 3.5 / 7.7 kN As (Required): %0.40 (min) 405.00 mm2 6Y16
vc'(1/2)= 0.73 / 0.60 N/mm2 As (Provided): %1.19 1206.37 mm2
v (1/2)= 0.04 / 0.08 N/mm2
Links = Y10-175

Project: BINO_HOTEL