You are on page 1of 3
Hydraulics Just a word: comfort Qa a =] = 4 © o a a Pot = - 2uesee ThyssenKrupp Elevator France A “full comfort” solution Saving in space. Ina low height building, the aditional superstructure of a machine roam takes up unaesthetic and bulky volumes. The ‘Thyssenkrupo Elevator hydraulic solution will ree you from the building design related constraints by: f removing the machinery above the shatt, « recucing the upper part af the shaft, « reducing the shait sizes, « providing a better distribution of stresses on the structures. ‘A simple design system. The car is gently driven, directy or indirectly by single or twin rams powered by a compact unit requiring only a small-sized room. Linked to the different characteristics of rams (diameter, type, length) and of power units (flow rate, pressure, power), these solutions offer you a great number of combinations. ‘The statian features a tank containing ol, a motor-driven pump ‘and a distibutor which provides the controlled drive of cylinders. 1 Even a lift has become an integral part of any building, provision of which must often comply with complex aesthe- tical and architectural constraints. Therefore ThyssenKrupp Elevator offers you the hydraulic power lift, a solution which combines flexibility with design freedom. Comfort and silence in addition. The Thyssenkrupp Elevator hydraulic solution perfectly matches the specification sheets which require a package of quality 2s a guarentee for comfot for vertical transport ‘Tre machine room is installed in the underground floor or far Away from the shaft (up to 15 meters from the ram) without rect communication with the shaft, thus reducing noise emissions. The mator and its screw pump are totaly immerse in a shack absorber suspended oil tank, providing smooth and silent ‘operation by greatly reducing ‘any operational noises as well {as the propagation of any vibration, ro res rd 7 ee pore side ae ram tng ro Pree en Acustomized installation. by a breakage valve, slack Thyssenkrupp Elevator offers pestpmin. rope safety device or by means some complementary equip- nun neo and deat ThyssenKrupp Elevator offers of speed governor. ment: lading wedges, overlaad paver spa tye pry i you a hydraulic crive unit for device, overpressure contact MLO) ett ar i installations with up to 20 Technological reliability. switch, additional heating in thout ary energy meters travel height, the machine room to provide @ ts 3'< 1.00 mis speed anda ‘The ThyssenKrupp Elevator constant and homogeneous {APN a 90-starts per hour traffic in the UM units have been sized to temperature for the pump unit, sw chewsos and canal standard layout. Regardless of prevent any overheating, the distributor and the immer-_s-Seiua eautpad wih the load, you ore offered severel Furthermore they are protected sad oll heating resistor. Sone single or Win rams soluions. via thermic sensors against ail Inthe direct acting solutions, overheating and via thermistrs rams are made of one ar mare 10 avoid ary motor everheating, flements according to the travel The installations are equipped 3 a to be run, Fastened drecy to wih protection vices against the ram, the cabin moves at slow creeping, breakage and hice ame speed asthe ram. overpressure in accordance ee Inthe indirect acting solutions withthe standards in force. theta recommended for longer tra- The elecic non-creeping «tarzan eon vels, diverter pulleys on the system proposed by ors rams carry the lifting ropes ‘ThyssenKrupp Elevator consists: _ — ee from a fixed point onthe cabin of an isoleveling combined in a and a secondary fixed point, mast cases with an automatic Coup pion thus allowing the cabin to return tothe lowest level ater Theat eds te : move twice the distance as the adjusted timing device. ‘pump unt a ram. In his case, the cabin In some arrangements, se ed on wn 3 moves twice 2s isoleveling is combined with @ a i quickly as the ram. ‘non-creeping speed governor a eduction i fom te 1 Depending on the selected ‘or with progressive wedges, tah ep wan preszan z arrangement, safely is ensured In order to optimize instalation, £

You might also like