Professional Documents
Culture Documents
m1t Throughbolt With Washer DIN 125A
m1t Throughbolt With Washer DIN 125A
Building material
Approvals
European Technical Approval Op- Nine gripping dents for adhesion Hardened and tempered anchor Clip in stainless steel A4 with
tion 1 for uncracked and cracked to hole walls body with special high resistance innovative design
concrete zinc plating 8µm ISO 4042, ≥
1000 hours in salt spray test ISO
9227
Features
• European Technical Approval Option 1 for uncracked and cracked concrete
• Fire resistance test certification F120
• Small edge and space distances
• Zinc plated > 8µm
• Pre installation or through fixing
Applications
• railings
• steel constructions
• profiles
• machines
• substructures
• high-racks
• cable trays
Installation
Make the drill hole Clean the drill hole Fix plug and building Tighten with a torque span-
material ner to the predetermined
value Tinst
M8 x 68 / 3
M8 x 75 / 10
M8 x 90 / 25
M8 x 115 / 50
M8 x 135 / 70
M8 x 165 / 100
M10 x 90 / 10
M10 x 105 / 25
M10 x 115 / 35
M10 x 135 / 55
M10 x 155 / 75
M12 x 110 / 10
M12 x 120 / 20
M12 x 145 / 45
M12 x 170 / 70
M16 x 130 / 10
M16 x 150 / 30
M16 x 185 / 60
16 x 220 / 100
Type
unc. Concrete C20/25 tension load (kN) 4.3 7.6 9.5 16.7
Cracked Concrete C20/25 tension load (kN) 2.9 5.7 7.6 9.5
Concrete C20/25 shear load (kN) c≥ 10xhef 6.2 11.4 16.2 31.4
Outer carton 800 600 300 400 300 150 300 200 150 160 120 90
Quantity per pallet 16000 12000 6000 8000 6000 3000 6000 4000 3000 3200 2400 1800
3800806
3800807
3800809
3800811
3800813
3800816
3801009
3801010
3801011
3801013
3801015
3801018
3801211
3801212
3801214
3801217
3801220
3801613
3801615
3801618
The partial safety factors of the resistances as well as a partial safety factor of the effect of γF = 1.4 are considered / Loads do not apply for reduced setting depths / 1 kN ≈ 100 kg