TEST REPORT

PRODUCT : AIR COOLER MODEL : ACDC50L Prepared by Approved by

DATE : 15/11/2022 DESERT COOLER

OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
A ELECTRICAL CHARECTERESTICS

A1 POWER CONSUMPTION Total power consumption of Air cooler checked on rated voltage & Shall not deviate from the rated input by more
frequency on VAW meter. than + 5%
A2 STARTING CHARECTERISTICS Product should start at < 160 V / Low Speed 160V Max.

Give supply to the product through VAW meter & run it on


At rated frequency, rated voltage & frequency for continuous 2 hr's.Note down
NORMAL TEMPERATURE RISE.- MAIN 230 V High speed, running for 2 hrs the initial & final resistance & temperature. BY using the
A3 MOTOR 250 V High speed running for 1 hrs & formula calculate the temp. Rise. Temperature rise should
180 V Low speed, running for 2 hrs not be more than 80°C
DT=((R2-R1)/R1*(225+T1))-(T2-T1) for AL winding
DT=((R2-R1)/R1*(234.5+T1))-(T2-T1) for CU winding

B BASIC PERFORMANCE
After two hours of continuous running check the RPM with
B1 MINIMUM RPM. At rated voltage & frequency, rated load of fan blade/Blower Assy, the help of Tachometer. RPM should be as per product
running for 2 hrs
declaration

RPM DIFFERENCE BETWEEN EACH At rated voltage & frequency, rated load of fan blade/Blower Assy, Take the RPM reading on all the Two / three speed .The diff.
B2 SPEED. running for 2 hrs Between each speed should be as per product declaration

After two hours of continuous running with the help of


At rated voltage & frequency, rated load of fan blade/Blower Assy, Anemometer take 8 reading of velocity on front grill ( Divide
B3 MINIMUM AIR VELOCITY IN M/SEC running for 2 hrs the front grill in 8 equal parts & take the max. reading in
each part.) Calculate the average of all readings. The avg.
reading should be as per product declaration

B4 MINIMUM AIR DELIVERY IN M3/Hr At rated voltage & frequency, rated load of fan blade/Blower Assy, Air delivery should be Min. 2000 M3/Hr.
running for 2 hrs (should be as per product declaration )

Kept the cooler in close chamber. Take the reference db of the chamber. Sound level should not be more than 65 db above reference
Run the cooler on rated Load, Voltage & Frequency on High speed for 30
min. With the help of db meter take the reading of sound level at a
B5 SOUND LEVEL distance of 1m away from the product at an angle of 45°(Left & Right
side) by keeping db meter in horizontal direction facing towards the
product at product height.

C GENERAL PERFORMANCE
WETTING OF WOOD WOOL PADS /
C1 H.COMB PADS At rated voltage / frequency , 2 Hrs running Pad Wetting should be 100%.

There should not be any kind of Sagging of Pads.


At rated voltage & frequency, rated load of fan blade/Blower Assy,
C2 SAGGING OF WOOD WOOL running for 2 hrs

Move louvers up & down rigorously for 100 times. There


C3 4 - WAY DEFLECTION Rough handling of louvers. should not be any kind of dislocation of the louvers.

Operate the Switches for 100 times. The functioning &


C4 SWITCH FUNCTIONING & INDEXING At rated voltage & frequency, rated load of fan blade/Blower Assy. Indexing of the switches should be OK.
At rated voltage & frequency, rated load of fan blade/Blower Assy. Keep Distance up to air velocity check, as per manufacturer
C5 AIR THROW DISTANCE the Horizontal louvers parallel to floor & Vertical louvers perpendicular to declaration (@0.5m/s)
floor.
C6 WATER LEVEL INDICATOR Cooler should be placed on flat surface/floor Indicator should clearly show the Water level in the tank.
OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
C7 CASTER OPERATION Cooler filled with water, to be moved on rough floor 1000 meter There should not be any damage.
C8 PUMP LVS Pump should start at < 160 V Pump should deliver continuous flow at 160V

LPM Must be as per product declaration to maintain cooling


C9 PUMP WATER LIFTING (LPM) Checked at rated voltage (230V) and low voltage (180V) efficiency & Pad wetting should be min 95% at low Voltage
(LPM @230V & 180V

C10 SWING MOTOR FUNCTION Checked at rated voltage and frequency Movement function of vertical louvers should be smooth.

Cooler should be free from scratches, flashes, moulding


C11 AESTHETICS Visual inspection of complete cooler defects, damages, leakage, loose fitting, color mismatch &
misprinting etc.
D SAFETY
D1 HIGH VOLTAGE TEST Normal condition between Live part & body earthing Should withstand at 1.0 KV for 1 Min

D2 INSULATION RESISTANCE Insulation Resistance test at 500 V DC between Live parts & Earthing. With the help of I.R tester check the resistance between live
parts & body. IR Should be > 2 M ohms at 500 VDC.
Should not be more than 210 Micro Amp.
D3 LEAKAGE CURRENT With the help of Leakage Current tester check the leakage current
between Line & Earthing & Neutral & Earthing.

Earthing connection test. Continuity to be tested at actual in product Should not be more than 0.2 Ohm.
D4 EARTH CONTINUITY RESISTANCE between Earthing terminal of the plug & Earthing point provided on
accessible metal parts.

E DURABILITY & STRUCTURE


APPEARANCE

DROP TEST Packed product, Total 10 no's drops, drop height as per Product Packing After test, should not show any sign of electrical &
Weight. mechanical damage .

E1 Packing should be good in aesthetic, no flute visible and


fitment with product and thermocole should be proper. BS
PACKING Visual and drop test should be as per weight to support transit and stacking
condition
TEST REPORT
PRODUCT : AIR COOLER MODEL : ACDC50L Prepared by Approved by

DATE : 15/11/2022 DESERT COOLER

OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
A ELECTRICAL CHARECTERESTICS

A1 POWER CONSUMPTION Total power consumption of Air cooler checked on rated voltage & Shall not deviate from the rated input by more
frequency on VAW meter. than + 5%
A2 STARTING CHARECTERISTICS Product should start at < 160 V / Low Speed 160V Max.

Give supply to the product through VAW meter & run it on


At rated frequency, rated voltage & frequency for continuous 2 hr's.Note down
NORMAL TEMPERATURE RISE.- MAIN 230 V High speed, running for 2 hrs the initial & final resistance & temperature. BY using the
A3 MOTOR 250 V High speed running for 1 hrs & formula calculate the temp. Rise. Temperature rise should
180 V Low speed, running for 2 hrs not be more than 80°C
DT=((R2-R1)/R1*(225+T1))-(T2-T1) for AL winding
DT=((R2-R1)/R1*(234.5+T1))-(T2-T1) for CU winding

B BASIC PERFORMANCE
After two hours of continuous running check the RPM with
B1 MINIMUM RPM. At rated voltage & frequency, rated load of fan blade/Blower Assy, the help of Tachometer. RPM should be as per product
running for 2 hrs
declaration

RPM DIFFERENCE BETWEEN EACH At rated voltage & frequency, rated load of fan blade/Blower Assy, Take the RPM reading on all the Two / three speed .The diff.
B2 SPEED. running for 2 hrs Between each speed should be as per product declaration

After two hours of continuous running with the help of


At rated voltage & frequency, rated load of fan blade/Blower Assy, Anemometer take 8 reading of velocity on front grill ( Divide
B3 MINIMUM AIR VELOCITY IN M/SEC running for 2 hrs the front grill in 8 equal parts & take the max. reading in
each part.) Calculate the average of all readings. The avg.
reading should be as per product declaration

B4 MINIMUM AIR DELIVERY IN M3/Hr At rated voltage & frequency, rated load of fan blade/Blower Assy, Air delivery should be Min. 2000 M3/Hr.
running for 2 hrs (should be as per product declaration )

Kept the cooler in close chamber. Take the reference db of the chamber. Sound level should not be more than 65 db above reference
Run the cooler on rated Load, Voltage & Frequency on High speed for 30
min. With the help of db meter take the reading of sound level at a
B5 SOUND LEVEL distance of 1m away from the product at an angle of 45°(Left & Right
side) by keeping db meter in horizontal direction facing towards the
product at product height.

C GENERAL PERFORMANCE
WETTING OF WOOD WOOL PADS /
C1 H.COMB PADS At rated voltage / frequency , 2 Hrs running Pad Wetting should be 100%.

There should not be any kind of Sagging of Pads.


At rated voltage & frequency, rated load of fan blade/Blower Assy,
C2 SAGGING OF WOOD WOOL running for 2 hrs

Move louvers up & down rigorously for 100 times. There


C3 4 - WAY DEFLECTION Rough handling of louvers. should not be any kind of dislocation of the louvers.

Operate the Switches for 100 times. The functioning &


C4 SWITCH FUNCTIONING & INDEXING At rated voltage & frequency, rated load of fan blade/Blower Assy. Indexing of the switches should be OK.
At rated voltage & frequency, rated load of fan blade/Blower Assy. Keep Distance up to air velocity check, as per manufacturer
C5 AIR THROW DISTANCE the Horizontal louvers parallel to floor & Vertical louvers perpendicular to declaration (@0.5m/s)
floor.
C6 WATER LEVEL INDICATOR Cooler should be placed on flat surface/floor Indicator should clearly show the Water level in the tank.
OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
C7 CASTER OPERATION Cooler filled with water, to be moved on rough floor 1000 meter There should not be any damage.
C8 PUMP LVS Pump should start at < 160 V Pump should deliver continuous flow at 160V

LPM Must be as per product declaration to maintain cooling


C9 PUMP WATER LIFTING (LPM) Checked at rated voltage (230V) and low voltage (180V) efficiency & Pad wetting should be min 95% at low Voltage
(LPM @230V & 180V

C10 SWING MOTOR FUNCTION Checked at rated voltage and frequency Movement function of vertical louvers should be smooth.

Cooler should be free from scratches, flashes, moulding


C11 AESTHETICS Visual inspection of complete cooler defects, damages, leakage, loose fitting, color mismatch &
misprinting etc.
D SAFETY
D1 HIGH VOLTAGE TEST Normal condition between Live part & body earthing Should withstand at 1.0 KV for 1 Min

D2 INSULATION RESISTANCE Insulation Resistance test at 500 V DC between Live parts & Earthing. With the help of I.R tester check the resistance between live
parts & body. IR Should be > 2 M ohms at 500 VDC.

With the help of Leakage Current tester check the leakage current Should not be more than 210 Micro Amp.
D3 LEAKAGE CURRENT between Line & Earthing & Neutral & Earthing.

Earthing connection test. Continuity to be tested at actual in product Should not be more than 0.2 Ohm.
D4 EARTH CONTINUITY RESISTANCE between Earthing terminal of the plug & Earthing point provided on
accessible metal parts.

E DURABILITY & STRUCTURE


APPEARANCE

DROP TEST Packed product, Total 10 no's drops, drop height as per Product Packing After test, should not show any sign of electrical &
Weight. mechanical damage .

E1 Packing should be good in aesthetic, no flute visible and


PACKING Visual and drop test fitment with product and thermocole should be proper. BS
should be as per weight to support transit and stacking
condition
TEST REPORT
PRODUCT : AIR COOLER MODEL : ACTC35L Prepared by Approved by

DATE : 15/11/2022 TOWER COOLER

OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
A ELECTRICAL CHARECTERESTICS

A1 POWER CONSUMPTION Total power consumption of Air cooler checked on rated voltage & Shall not deviate from the rated input by more
frequency on VAW meter. than + 5%
A2 STARTING CHARECTERISTICS Product should start at < 160 V / Low Speed 160V Max.

Give supply to the product through VAW meter & run it on


At rated frequency, rated voltage & frequency for continuous 2 hr's.Note down
NORMAL TEMPERATURE RISE.- MAIN 230 V High speed, running for 2 hrs the initial & final resistance & temperature. BY using the
A3 MOTOR 250 V High speed running for 1 hrs & formula calculate the temp. Rise. Temperature rise should
180 V Low speed, running for 2 hrs not be more than 80°C
DT=((R2-R1)/R1*(225+T1))-(T2-T1) for AL winding
DT=((R2-R1)/R1*(234.5+T1))-(T2-T1) for CU winding

B BASIC PERFORMANCE
After two hours of continuous running check the RPM with
B1 MINIMUM RPM. At rated voltage & frequency, rated load of fan blade/Blower Assy, the help of Tachometer. RPM should be as per product
running for 2 hrs
declaration

RPM DIFFERENCE BETWEEN EACH At rated voltage & frequency, rated load of fan blade/Blower Assy, Take the RPM reading on all the Two / three speed .The diff.
B2 SPEED. running for 2 hrs Between each speed should be as per product declaration

After two hours of continuous running with the help of


At rated voltage & frequency, rated load of fan blade/Blower Assy, Anemometer take 8 reading of velocity on front grill ( Divide
B3 MINIMUM AIR VELOCITY IN M/SEC running for 2 hrs the front grill in 8 equal parts & take the max. reading in
each part.) Calculate the average of all readings. The avg.
reading should be as per product declaration

B4 MINIMUM AIR DELIVERY IN M3/Hr At rated voltage & frequency, rated load of fan blade/Blower Assy, Air delivery should be Min. 2000 M3/Hr.
running for 2 hrs (should be as per product declaration )

Kept the cooler in close chamber. Take the reference db of the chamber. Sound level should not be more than 65 db above reference
Run the cooler on rated Load, Voltage & Frequency on High speed for 30
min. With the help of db meter take the reading of sound level at a
B5 SOUND LEVEL distance of 1m away from the product at an angle of 45°(Left & Right
side) by keeping db meter in horizontal direction facing towards the
product at product height.

C GENERAL PERFORMANCE
WETTING OF WOOD WOOL PADS /
C1 H.COMB PADS At rated voltage / frequency , 2 Hrs running Pad Wetting should be 100%.

There should not be any kind of Sagging of Pads.


At rated voltage & frequency, rated load of fan blade/Blower Assy,
C2 SAGGING OF WOOD WOOL running for 2 hrs

Move louvers up & down rigorously for 100 times. There


C3 4 - WAY DEFLECTION Rough handling of louvers. should not be any kind of dislocation of the louvers.

Operate the Switches for 100 times. The functioning &


C4 SWITCH FUNCTIONING & INDEXING At rated voltage & frequency, rated load of fan blade/Blower Assy. Indexing of the switches should be OK.
At rated voltage & frequency, rated load of fan blade/Blower Assy. Keep Distance up to air velocity check, as per manufacturer
C5 AIR THROW DISTANCE the Horizontal louvers parallel to floor & Vertical louvers perpendicular to declaration (@0.5m/s)
floor.
C6 WATER LEVEL INDICATOR Cooler should be placed on flat surface/floor Indicator should clearly show the Water level in the tank.
OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
C7 CASTER OPERATION Cooler filled with water, to be moved on rough floor 1000 meter There should not be any damage.
C8 PUMP LVS Pump should start at < 160 V Pump should deliver continuous flow at 160V

LPM Must be as per product declaration to maintain cooling


C9 PUMP WATER LIFTING (LPM) Checked at rated voltage (230V) and low voltage (180V) efficiency & Pad wetting should be min 95% at low Voltage
(LPM @230V & 180V

C10 SWING MOTOR FUNCTION Checked at rated voltage and frequency Movement function of vertical louvers should be smooth.

Cooler should be free from scratches, flashes, moulding


C11 AESTHETICS Visual inspection of complete cooler defects, damages, leakage, loose fitting, color mismatch &
misprinting etc.
D SAFETY
D1 HIGH VOLTAGE TEST Normal condition between Live part & body earthing Should withstand at 1.0 KV for 1 Min

D2 INSULATION RESISTANCE Insulation Resistance test at 500 V DC between Live parts & Earthing. With the help of I.R tester check the resistance between live
parts & body. IR Should be > 2 M ohms at 500 VDC.

With the help of Leakage Current tester check the leakage current Should not be more than 210 Micro Amp.
D3 LEAKAGE CURRENT between Line & Earthing & Neutral & Earthing.

Earthing connection test. Continuity to be tested at actual in product Should not be more than 0.2 Ohm.
D4 EARTH CONTINUITY RESISTANCE between Earthing terminal of the plug & Earthing point provided on
accessible metal parts.

E DURABILITY & STRUCTURE


APPEARANCE

DROP TEST Packed product, Total 10 no's drops, drop height as per Product Packing After test, should not show any sign of electrical &
Weight. mechanical damage .

E1 Packing should be good in aesthetic, no flute visible and


PACKING Visual and drop test fitment with product and thermocole should be proper. BS
should be as per weight to support transit and stacking
condition
TEST REPORT
PRODUCT : AIR COOLER MODEL : ACPC25L Prepared by Approved by

DATE : 15/11/2022 PERSONAL COOLER

OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
A ELECTRICAL CHARECTERESTICS

A1 POWER CONSUMPTION Total power consumption of Air cooler checked on rated voltage & Shall not deviate from the rated input by more
frequency on VAW meter. than + 5%
A2 STARTING CHARECTERISTICS Product should start at < 160 V / Low Speed 160V Max.

Give supply to the product through VAW meter & run it on


At rated frequency, rated voltage & frequency for continuous 2 hr's.Note down
NORMAL TEMPERATURE RISE.- MAIN 230 V High speed, running for 2 hrs the initial & final resistance & temperature. BY using the
A3 MOTOR 250 V High speed running for 1 hrs & formula calculate the temp. Rise. Temperature rise should
180 V Low speed, running for 2 hrs not be more than 80°C
DT=((R2-R1)/R1*(225+T1))-(T2-T1) for AL winding
DT=((R2-R1)/R1*(234.5+T1))-(T2-T1) for CU winding

B BASIC PERFORMANCE
After two hours of continuous running check the RPM with
B1 MINIMUM RPM. At rated voltage & frequency, rated load of fan blade/Blower Assy, the help of Tachometer. RPM should be as per product
running for 2 hrs
declaration

RPM DIFFERENCE BETWEEN EACH At rated voltage & frequency, rated load of fan blade/Blower Assy, Take the RPM reading on all the Two / three speed .The diff.
B2 SPEED. running for 2 hrs Between each speed should be as per product declaration

After two hours of continuous running with the help of


At rated voltage & frequency, rated load of fan blade/Blower Assy, Anemometer take 8 reading of velocity on front grill ( Divide
B3 MINIMUM AIR VELOCITY IN M/SEC running for 2 hrs the front grill in 8 equal parts & take the max. reading in
each part.) Calculate the average of all readings. The avg.
reading should be as per product declaration

B4 MINIMUM AIR DELIVERY IN M3/Hr At rated voltage & frequency, rated load of fan blade/Blower Assy, Air delivery should be Min. 2000 M3/Hr.
running for 2 hrs (should be as per product declaration )

Kept the cooler in close chamber. Take the reference db of the chamber. Sound level should not be more than 65 db above reference
Run the cooler on rated Load, Voltage & Frequency on High speed for 30
min. With the help of db meter take the reading of sound level at a
B5 SOUND LEVEL distance of 1m away from the product at an angle of 45°(Left & Right
side) by keeping db meter in horizontal direction facing towards the
product at product height.

C GENERAL PERFORMANCE
WETTING OF WOOD WOOL PADS /
C1 H.COMB PADS At rated voltage / frequency , 2 Hrs running Pad Wetting should be 100%.

There should not be any kind of Sagging of Pads.


At rated voltage & frequency, rated load of fan blade/Blower Assy,
C2 SAGGING OF WOOD WOOL running for 2 hrs

Move louvers up & down rigorously for 100 times. There


C3 4 - WAY DEFLECTION Rough handling of louvers. should not be any kind of dislocation of the louvers.

Operate the Switches for 100 times. The functioning &


C4 SWITCH FUNCTIONING & INDEXING At rated voltage & frequency, rated load of fan blade/Blower Assy. Indexing of the switches should be OK.
At rated voltage & frequency, rated load of fan blade/Blower Assy. Keep Distance up to air velocity check, as per manufacturer
C5 AIR THROW DISTANCE the Horizontal louvers parallel to floor & Vertical louvers perpendicular to declaration (@0.5m/s)
floor.
C6 WATER LEVEL INDICATOR Cooler should be placed on flat surface/floor Indicator should clearly show the Water level in the tank.
OBSERVATIONS
S.No. TEST ITEM TEST CONDITION SPECIFICATIONS REMARK
I II III IV V
C7 CASTER OPERATION Cooler filled with water, to be moved on rough floor 1000 meter There should not be any damage.
C8 PUMP LVS Pump should start at < 160 V Pump should deliver continuous flow at 160V

LPM Must be as per product declaration to maintain cooling


C9 PUMP WATER LIFTING (LPM) Checked at rated voltage (230V) and low voltage (180V) efficiency & Pad wetting should be min 95% at low Voltage
(LPM @230V & 180V

C10 SWING MOTOR FUNCTION Checked at rated voltage and frequency Movement function of vertical louvers should be smooth.

Cooler should be free from scratches, flashes, moulding


C11 AESTHETICS Visual inspection of complete cooler defects, damages, leakage, loose fitting, color mismatch &
misprinting etc.
D SAFETY
D1 HIGH VOLTAGE TEST Normal condition between Live part & body earthing Should withstand at 1.0 KV for 1 Min

D2 INSULATION RESISTANCE Insulation Resistance test at 500 V DC between Live parts & Earthing. With the help of I.R tester check the resistance between live
parts & body. IR Should be > 2 M ohms at 500 VDC.
Should not be more than 210 Micro Amp.
D3 LEAKAGE CURRENT With the help of Leakage Current tester check the leakage current
between Line & Earthing & Neutral & Earthing.

Earthing connection test. Continuity to be tested at actual in product Should not be more than 0.2 Ohm.
D4 EARTH CONTINUITY RESISTANCE between Earthing terminal of the plug & Earthing point provided on
accessible metal parts.

E DURABILITY & STRUCTURE


APPEARANCE

DROP TEST Packed product, Total 10 no's drops, drop height as per Product Packing After test, should not show any sign of electrical &
Weight. mechanical damage .

E1 Packing should be good in aesthetic, no flute visible and


fitment with product and thermocole should be proper. BS
PACKING Visual and drop test should be as per weight to support transit and stacking
condition