Inverters
Keywords Multi-level inverter, PWM, Transformerless
[Legend]
: ON
: OFF
2E E 0 -E -2E
0
CDC1 C1 CDC1 C1
2E E 2E E -1
(1) Mode 1 (2) Mode 2 Estimated output current value of Rate of use
basic cell 1: icell1 by C2
Fig. 3 Charge-Discharge Mode of the Flying Capacitor
0
Charge-discharge control of a flying capacitor is performed by
mode changeover in the basic cell. Estimated output current value of basic cell2: icell2
v * =
u m sin θu ( 1) <E >0 Mode 1 (C1 and C2 charged)
Since the current value flowing in the basic 2.4 Downscaled Model Configuration
cells can be estimated based on the detected values In order to confirm performance of the pro-
of voltage command value of the phase module and posed circuit, we produced a downscaled model for
phase current value, current control is possible with- evaluation. Fig. 5 shows circuit configuration of the
out installing additional current sensors. downscaled model. Table 2 shows specifications of
Load
vDC2 vC2
Table 2 Specifications of the Downscaled Model into a reverse rotation from forward 50Hz to 0Hz
Main circuit specifications of the produced downscaled model and further to reverse 50Hz. After that, the rotation
are shown.
was stopped. Fig. 6 shows the result of the induc-
Item Specifications tion motor test. Even in the case of a 4-quadrant
System voltage 420V operation, fluctuation was low in DC and flying
Rated power 8kVA capacitor voltages, and we confirmed that this would
System voltage frequency 50Hz offer stable operation.
Carrier frequency 1kHz 2.4.2 Sudden Load Change Test with a LR Load
Rated output of induction motor 5.5kW This testing was carried out by changing the
No. of poles of induction motor 4pole inverter load into the LR load. Fig. 7 shows the
Rated frequency of induction motor 50Hz result of a sudden load change test with an LR load.
The shown waveforms were observed when the
load resistance was changed while operation was
the downscaled model. The input side is connected maintained at an output voltage frequency of 50Hz.
with an AC power supply of 420V and 50Hz through A sudden load change was purposely caused in the
an input filter for the purpose of harmonics removal. area surrounded by the dotted lines in the figure. In
The output side was connected with an induction a moment when a sudden load change was caused,
motor or a load which was configured by resistor variations can be seen in DC and flying capacitor
and inductor (LR load). In this circuit configuration, voltages. After the lapse of a certain period, however,
Voltages vDC1 and vDC2 were set up at 360V while vC1 voltage fluctuations seemed to settle down. We
and vC2 were at 180V, respectively. In this state, DC confirmed that the input current followed up the out-
voltage control and input power factor control were put load.
carried out on the input side and frequency control
was conducted on the output side. With the use of
3 Application to Transformerless
the produced downscaled model, the following two
Multi-Level Medium Voltage Inverters
tests were carried out.
2.4.1 4-Quadrant Operation Test with an We are working on product commercialization
Induction Motor of transformerless multi-level medium voltage invert-
For this testing, an inverter load was connect- ers for 6.6kV motor drive, where the above power
ed to an induction motor. An output frequency com- conversion circuit is employed. Table 3 shows spec-
mand was given to start acceleration from 0Hz up to ifications of the product and its features are itemized
forward rotation at 50Hz. This rotation was changed below.
0
current (A) output
-200
+10
0
Input
-10
voltage (V)
+200
Inverter
0
output
-200
+10
0
current (A)
-10
Inverter
+400
+200
vC , vC (V) 200ms/div
0
1 2
+200
voltage (V)
0
-200
+10
current (A)
0
Input
-10
Inverter output
+200
voltage (V)
0
-200
+10
0
Inverter output
-10
current (A)
+200
vC1, vC2 (V)
0
25ms/div
Load increase (50% → 100%) Load decrease (100% → 50%)
( 1) 98% efficiency that is the highest in industrial ( 4 ) Reduction of input harmonics (IEEE519 com-
field (97% for our former product) pliant)
( 2 ) Smallest size in the industrial world (53% volu- Compared with conventional systems, since
metric rate compared with our former product) high efficiency is secured, the effect of energy con-
( 3 ) Power regeneration function as standard spec- servation is better than our conventional model
ification when applied to flow rate control for machinery such